39G Air Handling Unit

Similar documents
Air flow m3/h

39CQEC Air Handling Unit

39CQ Air Handling Unit

Modular Air Handling Unit

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

(Thin)DBFP (Ultrathin)DFP

Centeral Station Air Handling Unit

MODULAR AIR HANDLING UNIT. Models: FAC / FMC / FBC

AIR HANDLING UNITS. Revision AG 16-07

Double Skin Air Handling Units

EHH SERIES DRAW THROUGH FAN COILS CFM

AIR HANDLER SPECIFICATION

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

30KAV Variable Speed Air-cooled Screw Chiller

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Series 2 FS 100 HM Q S AH D on innovative. a full green. meeting. line features. Page No Introduction a high unit is. Air Handling Units

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Double Skin Air Handling Units

Double Skin Casing Air Handling Units

42CW/CH. Fan Coil Unit (High Static Pressure) 42CW/CH. Welcome to Carrier Website w w w. c a r r i e r. c o m. c n

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air Handling Units. T F E.

COMMERCIAL AIR CONDITIONERS. Air Handling Unit & Modular Air Handling Unit

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER

YAH SERIES FAN COIL UNITS

19DV Back-to-Back Centrifugal Liquid Chiller with PUREtec TM Refrigerant and Greenspeed TM Intelligence

Easdale International INFINITY

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Modular Supply Make-Up Air Unit

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

1.1 This section applies to air handling units for HVAC Systems.

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

DAZZLE TM series Cassette Type Fan Coil Unit. FC-NHDU4 Cassette Type Fan Coil Unit 340~2380 m 3 /h

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

Flexible and efficient: Close Climate Control for IT equipment

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

13 HYGENIC AIR HANDLING UNITS

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

SECTION AIR COILS

SECTION AIR HANDLING UNIT

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

LOW STATIC HYDRONIC DUCTED UNIT

Air Handling Units. Geniox. Quick guide

YMA Air Handling Units

VRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

General Catalogue. FORM SSI - G.C (94)

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

VERSO Air Handling Units

ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

The ultimate in air handling units: directly and indirectly fired

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

Air Handling Units. Real HVACR people who understand your needs.

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-to-Water Heat Pump

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

Technical Development Program

Customer id 2452 Project 1152 Unit 189 ACON From Inspection Side. Unit name AHU-22 R.05 Supply air EU m³/sec Exhaust air

CS 2. Central Station Air Handlers Double Wall & Single Wall Installation, Operation & Maintenance Manual. Form No. 6120A

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

SKYPAK II, 3 Ton Series, gives you a

JCseries EVAPORATIVE CONDENSER. engineering data

Steam Injection Humidifiers for use with steam boilers PRODUCT CATALOG

THE EVOLUTION OF THE STANDARD 39SQ. AIR HANDLING UNIT 0,4-7,3 m3/s

The ultimate in air handling units: directly and indirectly fired

SSL & SBS Engineering Guide

SECTION AIR COILS

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

High Heat COP. High/Low Stage

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Indoor Air Quality. For assured. Double Skin Air Handling Units

MLR SERIES MODULAR AIR HANDLING UNITS

set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit)

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

Beijing Holtop Artificial Environment Technology Co., Ltd

20-120RT Multi-functional Modular Combination High Efficiency & Energy Saving Keeping Technology Cool

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

Enjoy the Delighting Comfort Brought by High Air Quality

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

AIR HANDLING UNITS MANDÍK

Transcription:

39G Air Handling Unit Air flow: 2000 ~ 60000 m³/h

The Manufacturer reserves the right to change any produt specifications without prior notices Version: Supersede: Effective Date: CAT_39G_E-1307_02 CAT_39G_E-1205_01 Jul, 2013

Turn To The Experts Founded by the inventor of modern air conditioning, Carrier is the world s leader in high-technology heating, air-conditioning and refrigeration solutions. Carrier experts provide sustainable solutions, integrating energy-efficient products, building controls and energy services for residential, commercial, retail, transport and food service customers. Carrier is a part of UTC Build ing & Industrial Systems, a unit of United Technologies Corp., a leading provider to the aerospace and building systems industries worldwide. With a broad portfolio of advanced technical patent awards, our global R&D center in Shanghai develops innovative heat, ventilation and air-conditioning (HVAC) solutions. In 1998, Time magazine named Dr. Carrier oneof its 20 most influential builders and titans of the 20 th century.

Model Number Nomenclature 39G G 50 50 50 50 =1150mm Unit Orientation Air Flow 2

Double skin panel construction, excellent heat preservation The thickness of PU casing panel is 25mm, with light weight, good rigidity and thermal conductivity coefficient less than 0.0199W/m C. Moreover, special insulation treatment is conducted at the inner parts of the frame and the middle frame strips to prevent the cold bridge effect. The use of high-quality color steel sheet and galvanized steel sheet in the double-skin metal panel ensures good fireproof and rust preventive performance of the unit. New sealing material minimizing air leakage The unit casing is made up of panels, frame and sealing strips. The panels are connected accurately by adopting unique embedded abutting method. New type of sealing strips between the frame and the panels, and careful sealing design to all access panels and locations passing-through pipes ensure excellent air tightness of the unit, which completely complies with or exceeds the national standard GB/T14294-2008. Ingenious condensate drain pan This design ensures to drain all the condensed water. The drain valve is arranged at the bottom of the coil return circuit, and this can discharge the seeper and avoid the frost cracking of the coil. Corrugated damper flexible to adjust Fins are the "dual sine-wave" form and mechanically bonded with copper tubes, realizing excellent heat transfer efficiency. Hydrophilic aluminum foils may also be utilized to achieve better heat transfer performance. The standard coil header is constructed of steel and can also be customized with copper. Headers have drain and vent connections, so coil is drainable and has non air trapping circuits. The water in the coil must be discharged in winter to avoid the frost crack of the coil. If the coil face air velocity is higher than 2.5m /s, a drift eliminator can be installed on the back of the coil to effectively isolate moisture in air. Hot and cold water coils designed according to international standard With manual or electric mode available, the corrugated linkage damper can be opened flexibly, and can also add an electric controller as required. 3

Unit base Each section has a base, which enhances the strength of the whole unit, reduces vibration, and make it easy to transport and assemble. The fan has the optimized forward or backward double-inlet centrifugal type with low noise and high efficiency. The fan impeller and pulley are statically and dynamically balanced, and the whole fan is calibrated through the operational vibration testing, making the fan to operate stably and smoothly. With the fan and motor assembly mounted on a common base with shock absorber and the fan outlet isolated from the casing by a flexible connection and completely separated from moving parts, the vibration is effectively isolated. Moreover, the forward or backward impeller may be selected according to the air pressure and volume. Belt-driven Fan Backward Impeller Forward Impeller Various filters available to meet different needs Filters of various filtering levels are available ranging from primary filters (Panel type, efficiency: G4), to medium filters (Bag type, efficiency: F8), and to high filters (H13). And some special filters such as activated carbon filters, cartridge filters and destatic filters can also be provided. High efficiency Filter Bag Filter Panel Filter Modular design convenient to select The width, height and length of the unit are proportionally increased with 100mm as module. Each air volume corresponds with a certain unit type. Modular products save raw material and control costs to the maximum extent. Standard modular products make modeling and manufacturing faster and more convenient. All basic component parts are standard and interchangeable with competitive prices. The unit is designed to have removable panels on its one side, and the access panels are arranged in the necessary components, providing convenience for repair and maintenance of the fan, coil and filter. The coil is installed on the guide rail inside the drain pan, enabling easy maintenance, cleaning and removal. Easy maintenance 4

Quick Selection Unit Size Air Volume Coil Face Cooling/Heating Coil Capacity kw Steam Coil Heating Capacity(kW) Inside Dimension of Damper 39G Dimensions Area(m²) 2R Heating 4R Cooling 6R Cooling Hight Width 2330 55000 5.81 382.53 333.00 806.95* 772.5 2876*952.5 2350 3050 Note:1. The data of 2R coil heating capacity is under the standard condition. (Air temperature in is 15 db, water temperature in is 60 ) 2. The data of 4R coil cooling capacity is under the standard condition. (Air temperature in is 27 db/19.5 wb, water temperature in is 7 ) 3. The data of 6R coil cooling capacity is under the fresh air condition. (Air temperature in is 35 db/28 wb, water temperature in is 7 ) 4. The unit height does not include the damper on top and the base of 100mm (0608~2333) / 200mm (2532~4750) 5. The cooling and heating capacity of the coil in the table is just for your reference, the data with "*" means temperature difference of in/out is more than 5. Please refer Carrier AHU selection software for detail information. Software Computer Selection Our company provides the double-quick and accurate computer selection. We will get the reasonable and Functions & Features Project Management Modular Designer Free Section Combining 39G Performance Calculation Quotation Chinese-English interface 5

Standard Components No. Unit Section Diagram Section Length (M: Module) Remark 1 Return/Mixing/Supply Chamber (0608~0912) 5M (0913~1317) 6M (1418~1621) 8M (1822~2025) 9M (2125~2333) 11M 1.Could be used as access section 2.Could reduce the length of section suitably when the direction of in/out air is horizontal 2 Electrostatic/Bag/Combined Filter 6M Access section is recommended at upstream 3 Cooling Coil 5M or 6M For 0608~2333, the section length is 5M with drift eliminator and 6M without drift eliminator 4 Heating Coil 3M May be be installed together with the cold water coil if the cooling coil does not include a film humidifier and a drift eliminator 5 Steam Heating Coil 3M Pay attention that the steam pressure could impact the heating capacity 6 Electric Heating Coil 3M Pay attention to the power stage of control 7 Steam Humidifier 6M Pay attention that the steam pressure could impact the humidifier capacity 8 Film Humidifier* 3M May be installed directly in the coils and drain pan, no additional space needed 9 Spray Humidifier* 6M Could share the drift eliminator with cooling coil when it is installed next the coil. 10 Electric Humidifier 6M 11 Fan Refer to fan table Four discharge configurations available 12 Combined Mixing Chamber (0608~0913) 10M (0914~1825) 12M (2025~2333) 18M Could be used as access section 13 Attenuator Access section is recommended at upstream 6M(1Level) 12M(2Level) 14 Plenum/Access 3M 6M The length can not be less than 5M, when it is used as access section. 15 High Efficiency Filter 9M Already include the access section at upstream 16 Energy Recovery* 6M Pre-filter at upstream and access section at downstream are recommended 6

39G Electric Heating Coil Selection Unit Size Max. Power of Single Heater Power range of single Power range of tow- Power range of three- Face Area row electric heater Weight row electric heater Weight row electric heater Weight 39G2230 4160 5.74 < 114 142 100~225 205 200~335 267 Note: 1. Star connection is used for electric heater wiring. Multiple group control is acceptable with single group capability less than 30kW and power source of 380V/3 phase. 2. Minimum air velocity through the electric heating coil should be 2m/s. 3. When heating capacity can be reach by using 3-row electric heating coils, 3M casing should be used. 4. When heating capacity is more than capacity of 3-row electric heating coils, 6M casing and two electric heating coils are recommended. Filtration Requirement for Clean Rooms Clean Room Classifications Clean Room Classifications Flow Type Turbulence Transition Flow Quasi - laminar Flow Filter ratio Coarse Medium Fine 7

39G Fan and Motor Unit Size Fan Model Max. Motor Power Max. Motor Model Fan section length(mm) Horizontal Vertical Weight(kg) FC160 FC180 FC180 FC200 FC200 FC225 FC225 FC/BC250 FC/BC250 FC/BC280 FC/BC280 FC/BC315 FC/BC315 FC/BC355 FC/BC355 FC/BC500 FC/BC500 FC/BC900 39G2330 37 Y225 FC/BC900 FC/BC900 Note: Weight in this table is weight of fan and base, which doesn t include casing and motor weight. Please refer to the selection files for detailed fan motor specifications. 8

39G Coil Connections 39G2330 2450 1269 3" MPT 233 9

39G Steam Coil Connections 39G2330 2450 884 2" MPT 223 80 150 10

39G Horizontal Unit Air Outlet Arrangements and Flange Dimensions 39G2330 FC160 FC180 FC180 FC200 FC200 FC225 FC225 FC/BC250 FC/BC250 FC/BC280 FC/BC280 FC/BC315 FC/BC315 FC/BC355 FC/BC355 FC/BC500 FC/BC500 FC/BC900 FC/BC900 FC/BC900 795.0 1007.0 668 241 150 547 767.0 1130.0 754 241 150 604 11

39G Vertical Unit Air Outlet Arrangements and Flange Dimensions FC160 FC180 FC180 FC200 FC200 FC225 FC225 FC/BC250 FC/BC250 FC/BC280 FC/BC280 FC/BC315 FC/BC315 FC/BC355 FC/BC355 FC/BC500 FC/BC500 12