OIL FILTRATION SYSTEMS, INC. 111 Parkway Drive, Boerne, Texas Phone: Web: oilfiltrationsystems.com.

Similar documents
VUD. Vac-U-Dry Vacuum Dehydrators. hyprofiltration.com/vud

ACORE Filtration Co.,Ltd provides engineering,

Tel: Fax: Website:

VUD. Vac-U-Dry Vacuum Dehydrators. hyprofiltration.com/vud

VAC-U-DRY VACUUM DEHYDRATION SKIDS

Operations and Maintenance Manual

VAC-U-DRY VACUUM DEHYDRATOR

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

Vacuum Oil Purifier (VOP) (5 Pages. June 2017)

CFH Series High Efficiency Filters

Portable Purification zf04 Systems Models PVS 185, 600, 1200, 1800, 2700

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager

Steele Extrusion Machinery

Phoenix C 1 GPM - Membrane Based Portable Lube and Hydraulic Oil Purifier Cart

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Series 57 WATER/OIL SEPARATORS

Phoenix C4XE - Membrane Based Portable Lube and Hydraulic Oil Purifier Cart For use in Hazardous Duty Locations.

Oil-Less Rotary Screw Compressors

New Product Introductions 2011

Industrial Processing Solutions

SPECIFICATIONS MODEL EHV X VACUUM OIL PURIFIER

the condensate management specialist PURO-CT Sustainable Condensate Management CONDENSATE SEPARATORS

CHILLER. Operator s & Installation Manual

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

SECTION STEAM CONDENSATE PUMPS

Condensate Management Solutions

INSTALLATION AND SERVICE INSTRUCTIONS. Tuthill atlantic fluidics OSR-5, 10,15 & 20. Oil sealed liquid ring vacuum pump

ES2000 Series. Oil / Water Separators ENGINEERING YOUR SUCCESS. mb air systems ltd

Laboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package

RMF SYSTEMS PURE POWER

Vacuum Pump Vacuum Pump

LIST Price - $2, Model Number: MFD-1-27-GX-X-B-14. *Quick Delivery of Units are Subject to Prior Sales

Oil-Less Rotary Screw Compressors Variable Speed. Engineered to Save

PHoenix-M (Mini) PORTABLE LUBE AND HYDRAULICS OIL PURIFIER OWNER/OPERATIONS MANUAL

Technical Specifications & Pricing

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)

PowerVac G Single to Twin Conversion Kit [ ]

Oil burners fuel unit with solenoid valve

2002 METAL FORM MFG. Form No: CCIOM/03

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Reliable Solutions in. Level Indication & Control, Sight Flow Indication, Filtration & Separation. Working Together to Deliver

Atlas Copco. Oil-sealed rotary screw vacuum pumps GVS , cfm

Mobile Transformer Oil Purification Plant

Key Question. What is the most important aspect to the removal and cleaning of material?

Ingersoll Rand. Rotary Screw Air Compressors 5-15 hp (4-11 kw)

FM 517 San Leon, TX Toll Free: Office: (281) Fax: (281)

Rotary screw Air compressors. Fixed Speed 5 15HP

Condensate Drain Valves

IFPM32 Internormen Fluid Purifier Systems. Maintenance manual Version 1.4

WFH Series. High Efficiency Filters

Ingersoll Rand 5-15 hp. Rotary Screw Compressors

Nitrogen Generation Systems Compressed Air Dryers

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8

CH250 AND CH251 CHILLERS

Closing procedures for above-ground pools

Vacuum Pumps and Accessories

PZ1, PZ3 & PZ6 Installation Guide

EV-PRO CONDENSATE SEPARATORS

Fixed Speed Rotary Screw Compressors UP6 Series 4-11 kw (5-15 hp)

Electric Submersible Pumps

Compressed air preparation Compressed air storage Moisture management. Catalog #1

Industrial. Solutions brands you trust. Product Overview

EXAIR's compressed air operated Reversible Drum Vac System attaches

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

FLOOD KING 120V. 2. Keep all filters clean. Do not operate the machine if the filters are clogged.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

ARV -3 & ARV -10 Active Reservoir Vent Installation and Operation Manual

Sullair Drains for Compressed Air Systems Zero Air Loss and Timed Solenoid

Installation Instructions for. WaterMaster Series Fountains

Installation Instructions for. WaterMaster Series Fountains

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

SEPREMIUM 10 SEPREMIUM 20 SEPREMIUM 30 SEPREMIUM 10 SEPREMIUM 30

HYDROGEN SULFIDE REMOVAL SYSTEMS

Reve rsib le D rum Vac. Pump 55 gallons in 90 seconds! Two-way pumping action!

R 5 Central Vacuum Systems

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

ZLA Series Double-stages Vacuum Transformer Oil Purifier Transformer Oil Purification

2003 METAL FORM MFG. FORM NO: PCIOM/03

KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP NUFORS-CR MAGY-UL MAGY COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS LEVEL SENSED DRAINS

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Prime chiller. Inline Chiller. Instructions for Models #2645,2646

Locations Include: Food & Beverage. Chemical. Waste Water Treatment. Pulp & Paper. Energy, Oil & Gas

Model: 1100 Float-Controlled Condensate Trap, PN 25

Pumps SELECTION OF A PUMP

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

OIL/WATER SEPARATORS. Compressed Air & Process Filtration

NOTE: Parts are no longer available for this tool. The manual will continue on the next page.

QSV Series Vacuums an EnPro Industries company QUINCY QSV SERIES ROTARY SCREW VACUUM PUMPS 7.5 HP TO 200 HP

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08

TM Series. Induced Draft, Counter Flow Optional Accessories

Flexible Solutions for Air Quality

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

Used Fluid Handling Portable Used-Oil Gravity Drains

WORLD CLASS 2012 PRODUCT CATALOG. Filtration and Fluid Conditioning Products. Fluid Power

CBT LW MAINTENANCE GUIDE

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series

QUINCY QGS SERIES hp

Transcription:

Success Story Repair & Modification i of Competitors Oil Purification Systems 1. Repair & Enhancement of Pall HVP-900 (15 GPM) Oil Purifier 1 system. Page 2 2. Repair & Enhancement of FilterDyne (5 GPM) Oil Purifier 858-300. Pages 3, 4 & 5 3. Repair of Enhancement of Enervac (15 GPM) Oil Purifier 3 total systems. Page 6 4. Ultra Vac Information. Pages 7, 8 & 9 5. Repair & Enhancement of Gulfgate (10 GPM) Oil Purifier. Page 10 Call us at 830-816-3332 because we want to help you maximize the profitability of your on-sight filtration systems.

I. Repair & Enhancement of Pall HVP-900 1. Added Condensate Sump to prevent oil carryover from vacuum tower when foaming occurs. Customer requested this due to severe foaming and over 100 Gallons of oil hitting the ground and contaminated the top soil. 2. Added improved Vacuum Pump Lube System. Includes precision needle valve drip-oil control with lower level float shut down and alarm indication. The customer had the OEM oil lube reservoir go dry and cause the vacuum pump to fail. 3. Replaced all filters with OFS direct replacement filters. 4. Ran Stainless Steel Tubing for all connections on vacuum circuit. New Lube Reservoir with Low Level Alarm & Shutdown. New Condensate Sump to prevent foam carryover and consequent oil spills. Added High Oil Level Shutdown. Stainless Steel Tubing Installed Page 2

II. Repair & Enhancement of Filter Dyne 5 GPM Oil Purifier 858-300 - System 1 1. Rebuilt and replaced the existing failed liquid ring vacuum pump. 2. Repaired ruptured evaporator / radiator on water cooling system. 3. Improved the air inlet metering of air flow with precision needle valve and added air intake filter system. Previous system had no air intake filtration. 4. Replaced existing poly plastic tubing and brass compression residential plumbing fittings with stainless steel tubing and industrial Weather Head compression fittings. 5. Replaced all filters with OFS direct replacement filters. 6. Repainted and relabeled the system. Precision air intake control for vacuum regulation with air intake filter. Repaired ruptured evaporator / radiator on water cooling system Rebuilt liquid ring vacuum pump. Replaced existing poly plastic tubing and brass compression residential plumbing fittings with stainless steel tubing and industrial Weather Head compression fittings. Page 3

II. Repair & Enhancement of Filter Dyne 5 GPM Oil Purifier System 2. 1. Replaced the existing failed liquid ring vacuum pump with externally lubricated rotary vein. 2. Improved the air inlet metering of air flow with precision i needle valve and added d air intake filter system. Previous system had no air intake filtration. 3. Replaced existing poly plastic tubing and brass compression residential plumbing fittings with stainless steel tubing and industrial Weather Head compression fittings. 4. Replaced all filters with OFS direct replacement filters. Repair wiring i within the electrical l control panel. 6. Repainted and relabeled the system. Repair internal wiring and damaged thermo-coupler wires. Installed system lifting eye. Precision air intake control for vacuum regulation with air intake filter. Externally lubricated rotary vein vacuum pump with oil lubricator with low oil level shutdown. Replaced plastic tubing and brass compression fitting with stainless steel tubing and steel Weatherhead compression fittings. Installed gate valve for variable flow control on inlet & outlet flows. Page 4

II. Filter Dyne 5 GPM Oil Purifier Recommended Upgrade System 3. No electric DP Gauge with Shutdown. This design the pump will go into bypass and no oil will leave the system. Electrical Conduit is non metallic with non metallic fittings Lower Cost. We use Exterior Vinyl with internal steel with steel fittings to make an internal short go to ground. Also the conduit is more robust and does cost more. Must prime the liquid ring pump every startup with water. Must have continuous water supply for the condenser to operate and the system to be efficient. Water Sump for the liquid ring pump gets sludged up with process oil. Also dirt gets into the sump and wears out the liquid ring pump. Must remove entire top structure in order to clean it. Filterdyne uses PVC Hose on for their oil lines.??? Serious Reliability & Liability Concern Saves money but seriously this one is not good. Page 5

III. Repair of Enhancement of Enervac 15 GPM Oil Purifier 3 total systems. 1. Replaced Coalescer Media Filters inside the towers with permanent dispersion media permanent tdispersion i media does not thave to be changed dtherefore saving the customer from changing internal vacuum tower coalescer filters. The savings saved the customer thousands of dollars per year. 2. Removed and simplified all ¾ discharge oil plumbing and installed larger sized 1.5 discharge plumbing for improved oil flow and reduced backpressure on the pump. 3. Installed filter bypass line, installed filter differential pressure gauge & change filter light on the front control panel. 4. Repaired and modified electrical controls within the control panel. 5. Repainted and relabeled the system. Installed Permanent Dispersion Media Elements in the vacuum tower replaced coalescer elements never have to be changed again. Installed Differential Pressure Gauge and change filter light. Installed flow control bypass valve for variable flow control of inlet and outlet. Repaired electrical controls within the control panel. Removed and simplified all ¾ discharge oil plumbing and installed larger sized 1.5 discharge plumbing for improved oil flow and reduced backpressure on the pump. Page 6

IV. OIL FILTRATION SYSTEMS, INC. UltraVac Recommended Upgrades Electrical Conduit is non metallic with non metallic fittings Lower Cost. We use Exterior Vinyl with internal steel with steel fittings to make an internal short go to ground. Also the conduit is more robust and does cost more. Gast Rotary Vane Vacuum Pump. Very low cost pump. We stopped using them 2 years ago because of reliability problems. You can see where the customer is applying sealer to stop vacuum seal from leaking. Only 2 Bolts Hold Entire Vacuum Chamber Seal Seal is always breaking We have repaired several of these with a Flange Kit * Serious Reliability Concern No Main Power Disconnect Must Open Door with Live Panel * Serious Safety & Liability Concern Only 2 Bolts Hold Entire Condensate Tank Seal Seal is always breaking We have repaired several of these with a Flange Kit * Serious Reliability Concern Tower is not elevated relative to the oil pump The oil pump will cavitate very easy resulting in lower vacuum settings and poor water removal rates Page 7

The vacuum chamber is stainless steel. Our tower in steel and internally coated. The internal coating has been working very well. Only 2 Bolts Hold Entire Vacuum Chamber Seal Seal is always breaking We have repaired several of these with a Flange Kit * Serious Reliability Concern Only 2 Bolts Hold Entire Condensate Tank Seal Seal is always breaking We have repaired several of these with a Flange Kit * Serious Reliability Concern Page 8

Upgraded FTI or UltraVac Dehydrator Flanges Installed on Condensate sump & Vacuum Tower 1.5 X 20 Mesh Inlet Strainer Page 9

V. We repair, maintain and provide performance enhancements for Gulfgate Vacuum Dehydrators. Before Repair After Repair We have many performance features to make your Gulfgate Vacuum Dehydrator much easier and lower cost to operate. 1. We replace liquid-ring or water eductors with Claw vacuum pump systems. Eliminate the need for water - only one utlitly is required, electricity. 2. We replace water cooled condensers with air cooled heater exchangers Eliminate the need for water - only one utlitly is required, electricity. 3. Note: A typical Gulfgate System requiring water will consume water at a flow rate of 5 GPM. 5 GPM running 24/7 for 365 days (1 year) = 2.63 million gallons of water consumed in 1 year. Also by eliminating i water you decrease the possible risk of electric shock @ 480 Volts. 4. Replace Coalescer Elements in Vacuum Tower with Permanent Dispersion Media (PDM) Filter Elements this eliminates the need for costly coalescer element change-out because PDM Elements never need have to be changed. They also are no viscosity limited like coalescer elements. You can process up to ISO 680 Gear Oil with PDM Elements. Page 10