EXPANSION VALVES. See Red Dot Catalog Also. * 2 ton valves - all other valves are 1 1/2 ton (1) Includes M1 Adapter 71R8050 EX02280

Similar documents
To accomplish this, the refrigerant fi tis pumped throughh aclosed looped pipe system.

THERMOSTATIC EXPANSION VALVES Part 1

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

SERVICE ASSISTANT OVERVIEW FDSI Online Training

The Saturation process

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

Otherwise, you can continue reading the file on the following pages.

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois

Superheat charging curves for technicians

Checking the Charge on a Heat Pump in the Winter

HVAC/R Refrigerant Cycle Basics

Refrigeration Systems

SECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING

Warm Case Troubleshooting Guide 9/18/2014

Sporlan Valve Division Parker Hannifan/CIC Group

SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 10 SYSTEM CHARGING

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant

How to Diagnose a TXV Failurek

Installation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant

Technical Training Associates Presents. Commercial Refrigeration Equipment Servicing Part 1

Installation Manual BCS2000/3000

Installation Manual Mopar Engine Compartment Upgrade Kit

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

Air Conditioning Components

RTP Technical Bulletin

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

Everything You. NEED to KNOW. TXV does this by keeping the coil supplied

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

Class 1: Basic Refrigera0on Cycle. October 7 & 9, 2014

Installation Manual for. Series HWM and Non-ETI HYDRONIC WATER MODULE with SC and SD COMPRESSOR UNITS and R-410 REFRIGERANT

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1968 CHEVROLET IMPALA

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS UNIT OBJECTIVES

y Small dimensions. Easy to install in refrigerated counters or cold rooms

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

SERVICE MANUAL FOR ROOF TOP AIR CONDITIONERS

BASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation

Installation Manual BCS 1000/1500

Heat Reclaim. Benefits,Methods, & Troubleshooting By Dave Demma, Manager Supermarket Sales, Sporlan Division - Parker Hannifin Corporation

Technical Bulletin (TB-0037)

DAVE DEMMA ACHIEVING HEAD PRESSURE CONTROL

Rev B, 9/2/2009. Kodiak Chiller Overview

Thermostatic expansion valves for ammonia Type TEA

Use this Construction/HVAC Glossary to answer the questions below.

HVAC Systems What the Rater Needs to Know in the Field CALCS-PLUS

INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL

INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold

DESIGN STANDARDS SECTION 15600

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1

Understanding Head Pressure Control. Walter H Langille, M.A.Sc., P.Eng Sales Engineer KeepRite Refrigeration

Technical Review. Remote Condenser Cuber. Enhanced Refrigeration and Water Systems. CM 3 Technology. of a. with. using. models included are:

Hot gas bypass regulator, type CPCE Liquid gas mixer, type LG (accessory)

For an administrative fee of $9.97, you can get an un-locked, printable version of this book.

1956 FORD F-100 TRUCK

HEAT PUMPS. Carrier Corporation GT72-01 Cat. No

MODEL URS-1: FACTORY RETROFIT PROGRAM

Special Topics on Residential HVAC

HVAC Basics RESIDENTIAL AIR CONDITIONING

Executive Summary. Number of Low Number of High Number of Faults , Number of OK

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET NOVA

PL Series Premier Indoor Plenum Coils

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

Technical Information

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET CHEVELLE/ EL CAMINO NOTE: INSTRUCTIONS DEPICT CHEVELLE

Thermostat KPU. Data sheet

Installation Instructions

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

USING THE P-T CARD AS A SERVICE TOOL

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

The Refrigeration Cycle. Jerry Cohen President Jacco & Assoc.

SEVEN STEPS TO EFFECTIVE PRE- SEASON COOLING CHECKUPS

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

HIGH INLET TEMPERATURE REFRIGERATED AIR DRYERS. GHRN Series

Service Step by Step Trouble-Shooting Check-List

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST PLYMOUTH BELVEDERE

A Series Inertia Compressor Applications. Application Bulletin 115

AIR TO AIR HEAT PUMP SYSTEM DESIGN

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

mn Dometic KRA Refrigeration Price and Parts Guide

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

Automotive Air Conditioning systems

User s Information and Installation Instructions

HEAT/ COOL/ DEFROST FORD THUNDERBIRD

CME1856W Service Parts

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS

R Series Cooling Modules

QuickTips. Do you have questions? We have answers.

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

an ISO 9001:2015 Registered Company

Field Application of Advanced Residential Air Conditioning Systems

Transcription:

EXPANSION VALVES See Red Dot Catalog Also PART NO. DESCRIPTION INLET OUTLET FITTING -- INTERNAL EQUALIZED 20359 INTERNAL EQUALIZED 38722 INTERNAL EQUALIZED FITTING -- EXTERNAL EQUALIZED 71R8050 EXTERNAL EQUALIZED 20985 * EXTERNAL EQUALIZED FITTING -- INTERNAL EQUALIZED 38720 INTERNAL EQUALIZED EX02280 INTERNAL EQUALIZED 38683 INTERNAL EQUALIZED 38684 (1) INTERNAL EQUALIZED 3/8 MALE 3/8 MALE 16mm MALE 3/8 MALE O RING CAPILLARY LENGHT EQUALIZER LENGHT EQUALIZER FITTING 12 - - 33 - - 18 16.5 19 31 10 1/2 - - 22mm MALE 10 - - 12 - - O RING 12 - * 2 ton valves - all other valves are 1 1/2 ton (1) Includes 3901172M1 Adapter 71R8050 38722 20359 20985 38720 EX02280 38683 38684 HAROLD AG & MOBILE PRODUCTS EXPANSION VALVES C-1

EXPANSION VALVES See Red Dot Catalog Also PART NO. DESCRIPTION INLET OUTLET FITTING -- EXTERNAL EQUALIZED 38877 * EXTERNAL EQUALIZED 38872 * EXTERNAL EQUALIZED 71R8080 EXTERNAL EQUALIZED CAPILLARY LENGHT EQUALIZER LENGHT 8 9 5/8 9 9 O RING 10 10 31-10738 EXTERNAL EQUALIZED 16 MM 20 MM 11 9 38610 EXTERNAL EQUALIZED 38622 * EXTERNAL EQUALIZED 38623 ORIFICE OT05925 ORIFICE 3/8 MALE 19 17 33 31 EQUALIZER FITTING 1/4 MALE O RING 12 MM FEMALE 1/4 MALE * 2 ton valves - all other valves are 1 1/2 ton 38610 38877 71R8100 38872 31-10738 38622 38623 OT05925 71R8080 EXPANSION VALVES C-2 12/03/2013 1-800-541-8910

PART NO. DESCRIPTION 21921 BLOCK TYPE LIQUID INLET From Compressor OUTLET To Evaporator INLET From Evaporator SUCTION OUTLET To Compressor 21920* # FLANGED 21921 # FLANGED 21922* # 2 THREADED 21923 # THREADED 3/8 1/2 5/8 #13 3/4 21924 # FLANGED/STUD #13 EX03700 * # THREADED 3/8 1/2 1/2 5/8 EX03703 * THREADED 3/8 1/2 1/2 5/8 38892 * FLANGED #12 38893 * FLANGED ORING 71R8301 # THREADED 3/8 O RING 1/2 1/2 5/8 71R8330 # * THREADED 3/8 1/2 5/8 5/8 EX03727 # * FLANGED #12 EX03720 # FLANGED EX03722 FLANGED 3/8 #12 3/4 #12 3/4 #12 3/4 EX03738 # FLANGED #12 EX03739 * FLANGED 3/8 1/2 5/8 #12 3/4 EX03740 (1) # THREADED 3/8 1/2 1/2 5/8 EX03746 # FLANGED EX03747 THREADED 3/8 1/2 5/8 5/8 EX03748 # THREADED 3/8 1/2 1/2 5/8 EX03750 FLANGED (1) Hi-Side 1/4 Male Switch Port (2) Lo-Side 1/4 Male Switch Port * 2 ton valves - all other valves are 1 1/2 ton # Has Mounting Holes #12 #12 21920 21922 21923 EX03739 21924 71R8301 EX03700 #12 38892 38893 71R8330 EX03720 #12 #12 #12 EX03722 #12 EX03727 #12 EX03738 EX03740 HAROLD AG & MOBILE PRODUCTS EX03746 EX03748 EX03703 EX03747 EX03750 EXPANSION VALVES C-3

EXPANSION VALVE ACCESSORIES PART NO. DESCRIPTION 40610 Clamp, Expansion Bulb (For 3/8 Coil or 1/2 Tube Type) 51683 External Equalizer Seal 61003 Prestite Tape 30 Ft. Roll (Sold by the foot) wrapped around expansion bulb or coil. 21996 Expansion Valve Screen EXPANSION VALVES C-4 12/03/2013 1-800-541-8910

Part No Price Comment 20359 $20.00 20985 $20.00 21920 $50.00 21921 $30.00 21922 $45.00 21923 $85.00 21924 $85.00 21996 $2.50 38606 $35.00 38610 $45.00 38620 $0.00 R/B EX03700 38622 $35.00 38623 $5.00 38683 $35.00 38684 $75.00 38720 $35.00 38722 $45.00 38872 $40.00 38877 $27.50 38892 $40.00 38893 $45.00 40610 $0.50 51683 $0.25 71R8050 $32.71 71R8100 $37.10 71R8301 $39.39 71R8330 $40.00 902-219 $0.00 N/A EX02219 $0.00 N/A EX02280 $60.00 EX03700 $40.00 EX03703 $40.00 EX03720 $50.00 EX03722 $40.00 EX03727 $60.00 EX03738 $60.00 EX03740 $40.00 EX03746 $45.00 EX03747 $75.00 EX03748 $75.00 EX03750 $65.00 OT05925 $7.00 HECO EXPANSION VALVE PRICES Prices are Subject to change without notice HAROLD AG & MOBILE PRODUCTS EXPANSION VALVES C-5

EXPANSION VALVE Section 811 W. Rose, Walla Walla, WA 99362 Phone: (509)525-5070 Fax: (509)525-3753 1-800-541-8910 www.heco.net E-mail: heco@bmi.net The TXV... learning to like them. The TXV is used in so many refrigerant circuits that rarely is it even called by its true name... the THER- MOSTATIC EXPANSION VALVE. There are other expansion valves that are not thermostatic but is the automotive world all TXV s are called expansion valves. Why do we use expansion valves? The answer is almost totally in their name. Valve because we must have some device for the controlling refrigerant feed to the evaporator. Expansion because there must be a device for lowering the high pressure of the refrigerant leaving the liquid line. The expansion valve does both of these things. The thermostatic expansion valve serves these two purposes by using a temperature of the refrigerant leaving the evaporator. The TXV measures that temperature with a bulb clamped to the outside of the suction line, The bulb is filled with a refrigerant charge that increases in pressure as the bulb gets warmer. This pressure change then moves a diaphragm on the valve which opens or closes the refrigerant path within the valve. The warmer the bulb gets, the wider the opening gets and the more refrigerant that is allowed to enter the evaporator. As more refrigerant enters the evaporator coil, the temperature of the gas leaving the evaporator will lower, cooling the bulb and reducing the flow through the valve. The valve flow will settle at a position to hold the original setting of the valve. Setting? Most valves are not adjustable, so how are you going to set them? True, they can t be set in the field but they are set at the factory. The setting they have is called their superheat setting and it is one of the most important settings in an air conditioning system. The only control the TXV can accomplish is to maintain a constant superheat at the exit of the evaporator. It does not maintain a constant refrigerant feed or coil temperature. Only a constant superheat. Designers select superheat settings based on many factors: evaporator design, flow rate, system capacity, etc. For this reason TXV s should not be substituted unless the technician is certain their operating characteristics are identical to the original. The most important characteristic is the superheat setting. It would be nice if we could close on that simple fact. We can t. We might have led you to believe that superheat is a single temperature. It is not. Superheat is the difference between two temperatures. SUPERHEAT = EVAP. OUTLET TEMP. (Measured by bulb) - (MINUS) SATURATION TEMP. (Found by Measuring Suction Pressure) EXPANSION VALVES C-6 12/03/2013 1-800-541-8910

The TXV and SUPERHEAT Evaporators are hard working components in an automotive air conditioner. The sad part is that, by themselves, they are refrigerant guzzlers that if not controlled would send deadly slugs of liquid to the compressor. An evaporator, working as designed, takes in just enough liquid to do its cooling job-and no more. An evaporator that is receiving less than the proper amount is said to be starved. An evaporator receiving too much refrigerant is said to be flooded or slugging. Both conditions must be avoided in most applications. One device that does the metering job is the TXV - the Thermostatic Expansion Valve. A moving pin within the TXV meters refrigerant at a precise rate to match the needs of the evaporator. But how does the TXV know how much refrigerant the evaporator needs? If you were to make that decision how would you do it? You would find a way to see the condition of the refrigerant leaving the evaporator. If you see liquid you would close down the valve a little until you saw nothing but gas, Once you saw nothing but gas, you would open the valve ever so little until you saw the last drop of liquid evaporate at the evaporator exit. The arrangement gives you maximum cooling with no chance of liquid entering the suction line. The TXV does this same job by measuring the superheat of the gas at the evaporator exit. Simply stated, superheat is the additional heat that goes into a gas after it has been evaporated. Until all liquid has evaporated the superheat will stay at zero. At the point the last drop of liquid evaporates, the superheat will start to rise and will keep rising as the gas absorbs the heat. The TXV measures the two things that must be known to determine superheat: Suction pressure (measured at the underside of the diaphragm) which tells us the temperature of the gas at zero superheat; and the actual gas temperature (measured by the bulb). The difference between these two temperatures is the superheat. As suction pressure goes up the valve tends to close. As bulb temperature goes up the valve will open. It is the spring which is set at the factory that will determine the superheat level the valve will maintain. Most automotive expansion valves are set to control a superheat level between 7 and 12 degrees. HAROLD AG & MOBILE PRODUCTS EXPANSION VALVES C-7