Sprinkler Inspection Certificate

Similar documents
Fire Alarm and Life Safety System Inspection Certificate

Fire Alarm and Life Safety System Inspection Certificate

Fire Alarm and Life Safety System Inspection Certificate

Fire Alarm and Life Safety System Inspection Certificate

Fire Alarm and Life Safety System Inspection Certificate

Inspection Report Nursing Home Life Safety Code Section 4 - Annual Fire Alarm Testing and Maintenance. For

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Gas Station & C Store SECTION CWM Job No

SecurityScan Inspection Certificate

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

ADDENDUM NO. 3 March 19, 2018

SPRINKLER SYSTEM DRY WET

Residential Fire Sprinkler Inspection

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

A. This section includes design and performance information for fire protection and suppression systems.

USAutomatic Sprinkler Corporation

SECTION WET-PIPE FIRE-SUPPRESSION SPRINKLERS

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System

PURCHASING DEPARTMENT DIVISION OF BUDGET & FINANCE

WET-PIPE SPRINKLER SYSTEMS

TECHNICAL DATA. 32a. September 18, /4-8 (DN32 - DN200)

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

TECHNICAL DATA. 31a. September 18, (DN25 - DN50)

DIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

Port of St Helens SIA Aircraft Hanger Scappoose, OR

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection

TECHNICAL DATA EASYPAC COMMERCIAL RISER MANIFOLD ASSEMBLIES 1-1/4-8 (DN32 - DN200)

Environmental Health & Safety

Simple On The Outside...

Quick Guide for Fire Sprinkler Inspection Requirements Key Deficiencies with NFPA References NFPA & NFPA 13/

SECTION WET FIRE SPRINKLER SYSTEMS

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

Report of Inspection/Test

North Hanover Township School District North Hanover Township, New Jersey

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION FIRE PROTECTION

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

2. Welding Materials and Procedures shall conform to the ASME Code.

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

SECTION WET-PIPE SPRINKLER SYSTEMS

PHYSICAL FACILITIES. 1 General. 2 Related Requirements. 5 Quality Assurance. 3 Wiring. 4 Submittals

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

A. This Section includes the following fire-suppression piping inside the building:

Design and Construction Standards SECTION FIRE SUPPRESSION

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

New Construction Fire Inspection Process

DIVISION 21: FIRE SUPPRESSION WATER BASED FIRE SUPRESSION SYSTEMS

WALL ESCUTCHEON PIPE SEAL WITH APPROVED FIRE CAULKING (SEE SPECIFICATIONS) NOTE: 12" 12" 24"

SECTION FIRE SUPRESSION

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

B. Related Sections: The following Sections contain requirements that relate to this Section.

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

Division 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21

False Sense of Security???

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

SUMMARY. Building receiving sprinkler credit: SPRINKLERED. Grade: 68. Percent of Building Sprinklered: 100% Sprinkler Demand Met: 91%

2016 CDM Smith All Rights Reserved July 2016 SECTION FIRE PROTECTION - SPRINKLER AND STANDPIPE SYSTEMS

SECTION DRY-PIPE FIRE-SUPPRESSION SPRINKLERS

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

Box-in-Box Cold Storage Fire Protection Options

DIVISION 21 - FIRE SUPPRESSION

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

May 2017 Middleton Heritage 09T SC DIVISION 21: FIRE SUPPRESSION END OF TABLE OF CONTENTS

Final EC Inspection Report 03/2010

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

A. Standard-Pressure Piping System Component: Listed for 175-psig minimum working pressure.

FIRE PROTECTION BASIC MATERIALS AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

DIVISION 21 - FIRE SUPPRESSION

Fire Sprinkler Monitoring & Releasing Systems. Training Manual. Manual # REV H 7/18

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Design & Construction Standards, Revised January

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

Fire Sprinkler Monitoring Products. Solutions and Service for Sprinkler System Integrity

Inspector: PROPERTY INFORMATION Photo Smoke Detector Notification Control Panel Stand Alone Smoke Detector Dialer SUMMARY ONLY

SECTION PREACTION SPRINKLER SYSTEMS

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

SECTION FIRE SUPPRESSION SYSTEMS

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

FIRE SUPPRESSION SPRINKLER SYSTEM

UBC Technical Guidelines Section Edition Fire Protection General Requirements Page 1 of 6

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

A. All Fire Suppression System design and installation shall comply with the most current and adopted version of NFPA 13.

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

Chapter 4: Fire Protection Systems

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION

HYDRAULIC CALCULATIONS. 952 Arapahoe

Transcription:

Sprinkler Inspection Certificate For New Dimensions High School 4900 Old Pleasant Hilll Road Kissimmee, FL 34746 Tested to NFPA 25 Standards This Inspection was performed in accordance with applicable NFPA Standards. The subsequent pages of this report provide performance measurements, listed ranges of acceptable results, and complete documentation of the inspection. Whenever discrepancies exist between acceptable performance standards and actual test results, notes and/or recommended solutions have been proposed or provided for immediate review and approval. Inspection Date May 28, 2015 Contact: Mrs. Grimm Title: Director Company: Fire & Life Safety America, Inc. - Orlando Contact: Chris Bader Title: Inspector

Executive Summary Generated by: BuildingReports.com Building Information Contact: Mrs. Grimm Address: 4900 Old Pleasant Hilll Road Phone: 407-870-9949 Address: City/State/Zip: Kissimmee, FL 34746 Country: United States of America Inspection Performed By Company: Fire & Life Safety America, Inc. - Orlando Fax: Mobile: Email: GRIMM@NEWDIMENSIONSHS.COM Inspector: Chris Bader Address: 2280 Old Lake Mary Road Phone: 407-688-1949 Address: Lic# 17068600012009 / EF # EF20000881 City/State/Zip: Sanford, Florida 32771 Country: United States of America System Control Unit Fax: Mobile: Email: rbader@ecfp.com System Type System Location Protected Area Devices Wet Pipe 400 21 Wet Pipe Gymnasium 18 Inspection Summary Category Total Items Serviced Passed Failed/Other Qty % Qty % Qty % Qty % Valve 14 35.90% 14 100.00% 12 85.71% 2 14.29% Hose 2 5.13% 2 100.00% 2 100.00% 0 0% Device 6 15.38% 6 100.00% 6 100.00% 0 0% Sprinkler 9 23.08% 9 100.00% 9 100.00% 0 0% Alarm 8 20.51% 8 100.00% 7 87.50% 1 12.50% Certification Totals 39 100% 39 100.00 % 36 92.31% 3 7.69% Company: Fire & Life Safety America, Inc. - Orlando Inspector: Chris Bader Contact: Mrs. Grimm Signed: Signed: Fire & Life Safety America, Inc. - Orlando 1 06/01/2015

Discrepancy Report Generated by: BuildingReports.com The Discrepancy Report consolidates each discrepancy listed within the various Testing sections of your Inspection. Discrepancies are listed by Category, and grouped by device type. The description of the problem is provided and where appropriate, code references are listed for your convenience. Any item that was inspected that is listed on the Consumer Product Safety Commissions website and are subject to a recall by the manufacturer are included. Device Type Manufacturer ModelNumber Date Qty Items listed for Recall by Manufacturer No recalled items found during this inspection. ScanID Location Problem Reference Backflow Prevention Wet Pipe, Gymnasium 07320172 Failed Test NFPA25 13.6.2.1 Control Valve 07320165 Backflow c.v.2 Leaking NFPA25 13.3.2.2 (5) Tamper Switch 07320164 Backflow c.v.2 Damaged/Worn NFPA25 13.2.3 NFPA25 13.6.2.1 NFPA25 13.3.2.2 (5) NFPA25 13.2.3 Code References All backflow preventers installed in fire protection system piping shall be tested annually by conducting a forward flow test of the system at the designed flow rate, including hose stream demand, where hydrants or inside hose stations are located downstream of the backflow preventer. The valve inspection shall verify that the valves are in the following condition: Free from external leaks All system valves shall be protected from physical damage and shall be accessible. Fire & Life Safety America, Inc. - Orlando 2 06/01/2015

Proposed Solutions Report Generated by: BuildingReports.com The Proposed Solution Report provides a solution for each discrepancy listed on the Discrepancy Report. Provide a check mark where indicated to approve repairs listed within the report. Items listed as T/M are available for repair on a Time and Materials basis. ScanID Location Solution Model # Cost Fix Backflow Prevention Wet Pipe, Gymnasium 07320172 Correct 007M1 T/M Control Valve 07320165 Backflow c.v.2 Correct T/M Tamper Switch 07320164 Backflow c.v.2 Correct OSYSU-2 T/M Fire & Life Safety America, Inc. - Orlando 3 06/01/2015

Inspection & Testing Generated by: BuildingReports.com The Inspection & Testing section lists all of the items inspected in your building. Items are grouped by Passed or Failed/Other. Items are listed by Category. Each item includes the services performed, and the time & date at which testing occurred. For more information about an item, click on the link provided. Device Type Location Service Time Date Wet Pipe, 400 Passed Tamper Switch 1st Center Janitor Closet Annual 11:23:26 AM 05/28/2015 Tamper Switch Ground West end of classrooms Annual 11:32:22 AM 05/28/2015 Tamper Switch Ground West end of classrooms Annual 11:34:00 AM 05/28/2015 Tamper Switch Ground West end of classrooms Annual 11:35:00 AM 05/28/2015 Waterflow Switch 1st Center Janitor Closet Annual 11:28:22 AM 05/28/2015 Drain 1st Center Janitor Closet Annual 11:22:19 AM 05/28/2015 Gauge 1st Center Janitor Closet Annual 11:20:22 AM 05/28/2015 Gauge 1st Center Janitor Closet Annual 11:21:22 AM 05/28/2015 Watermotor Gong 1st Center Janitor Closet Outside Annual 11:28:49 AM 05/28/2015 Fire Dep't Connection Ground corner of office in parking lot Annual 12:21:56 PM 05/28/2015 Sprinkler Box 1st Center Janitor Closet Annual 11:22:40 AM 05/28/2015 Sprinkler Box Spares 1st Center Janitor Closet Annual 11:22:46 AM 05/28/2015 Sprinkler Box Spares 1st Center Janitor Closet Annual 11:22:52 AM 05/28/2015 Backflow Prevention Ground West end of classrooms Annual 12:38:16 PM 05/28/2015 Backflow Prevention Ground West end of classrooms Annual 12:38:29 PM 05/28/2015 Check Valve 1st Center Janitor Closet Annual 11:21:39 AM 05/28/2015 Control Valve 1st Center Janitor Closet Annual 11:27:45 AM 05/28/2015 Control Valve Ground West end of classrooms Annual 11:34:04 AM 05/28/2015 Control Valve Ground West end of classrooms Annual 11:34:39 AM 05/28/2015 Inspector's Test 1st Center Janitor Closet Annual 11:21:50 AM 05/28/2015 Post Indicator Valve Ground West end of classrooms Annual 11:32:02 AM 05/28/2015 Wet Pipe, Gymnasium Tamper Switch Backflow c.v.1 Annual 11:54:45 AM 05/28/2015 Waterflow Switch Outside riser Annual 11:58:01 AM 05/28/2015 Drain Ground Outside near parking lot Annual 11:57:07 AM 05/28/2015 Gauge Outside riser Annual 11:57:08 AM 05/28/2015 Fire Dep't Connection Ground corner of gym near parking lot Annual 12:00:34 PM 05/28/2015 Fast Response FACP Room Annual 11:59:08 AM 05/28/2015 Fast Response FACP Room Annual 11:59:09 AM 05/28/2015 Fast Response FACP Room Annual 11:59:11 AM 05/28/2015 Piping Annual 11:57:54 AM 05/28/2015 Sprinkler Box FACP Room Annual 11:59:52 AM 05/28/2015 Sprinkler Box FACP Room Annual 11:59:57 AM 05/28/2015 Backflow Prevention Annual 12:52:53 PM 05/28/2015 Check Valve Ground corner of gym near parking lot Annual 12:07:24 PM 05/28/2015 Control Valve Backflow c.v.1 Annual 11:54:05 AM 05/28/2015 Inspector's Test 1st above ceiling room 301 Annual 11:50:22 AM 05/28/2015 Fire & Life Safety America, Inc. - Orlando 4 06/01/2015

Device Type Location Service Time Date Failed/Other Wet Pipe, Gymnasium Tamper Switch Backflow c.v.2 Annual 12:54:00 PM 05/28/2015 Backflow Prevention Annual 12:49:01 PM 05/28/2015 Control Valve Backflow c.v.2 Annual 12:53:07 PM 05/28/2015 Fire & Life Safety America, Inc. - Orlando 5 06/01/2015

Wet Pipe Fire Sprinkler Systems Generated by: BuildingReports.com 400 A sprinkler system employing automatic sprinklers attached to a piping system containing water and connected to a water supply so that water discharges immediately from sprinklers opened by heat from a fire. Tamper Switch Alarms Type Description Manufacturer Sec Zone/Address OK ScanID Control Valve Supervisory Victaulic 1 32459283 Lever Supervisory Potter Electric 1 28342821 Lever Supervisory System Sensor 1 28342826 Lever Supervisory System Sensor 1 28342823 Waterflow Switch Type Manufacturer Model # Sec Size Zone/Address OK ScanID Vane System Sensor wfd25 40 1 28342833 Backflow Prevention Components Manufacturer Model # Size Type Service Type Install Date Watts Regulator 007M3 0.75" Double Check 11/03/2011 Location Water Purveyor Meter Account # Serial Number Ground West end of classrooms Initial Test Check Valve 1 Check Valve 2 Relief Valve Pressure Vacuum Breaker 1.8 1.8 Held At Repairs or Notes Final Test Check Valve 1 Check Valve 2 Relief Valve Pressure Vacuum Breaker Held At Condition of Control Valve 1 Condition of Control Valve 2 Backflow Prevention Manufacturer Model # Size Type Service Type Install Date Watts Regulator 757 8" Double Check 11/03/2011 Location Water Purveyor Meter Account # Serial Number Ground West end of classrooms Initial Test Fire & Life Safety America, Inc. - Orlando 6 06/01/2015

Check Valve 1 Check Valve 2 Relief Valve Pressure Vacuum Breaker 2.8 3.6 Held At Repairs or Notes Final Test Check Valve 1 Check Valve 2 Relief Valve Pressure Vacuum Breaker Held At Condition of Control Valve 1 Condition of Control Valve 2 Check Valve Type Location Size OK ScanID Grooved 1st Center Janitor Closet 4" 28342830 Control Valve Type Manufacturer Size Position Status OK ScanID Butterfly Victaulic 4" Open Sealed 28342827 OS&Y Kennedy 8" Open Locked 28342825 OS&Y Kennedy 8" Open Locked 28342824 Inspector's Test Manufacturer Model # Pressure psi Trip Time Sec Flow Sec OK ScanID AGF 28342832 Post Indicator Valve Type Position Status Size OK ScanID Ground Open Sealed 6" 28342822 Drain Devices Type Size Supply psi Static psi Residual psi Sec OK ScanID Main 2" 70 70 50 20 28342831 Fire Dep't Connection Location Type Size OK ScanID Ground corner of office in parking lot Freestanding 4" 28342819 Gauge Type Location Static psi Fill Type Size OK ScanID System Pressure 1st Center Janitor Closet 70 Air 1/4 28342828 System Pressure 1st Center Janitor Closet 70 Air 1/4 28342829 Sprinkler Box Qty Tool Available? Size Manufacturer Location OK ScanID 6 Yes 6 unit Tyco 1st Center Janitor Closet 28342834 Sprinkler Box Spares Qty Type K factor Manufacturer Location OK ScanID Fire & Life Safety America, Inc. - Orlando 7 06/01/2015

4 Pendant Tyco 1st Center Janitor Closet 2 Upright Tyco 1st Center Janitor Closet 28342835 28342836 Watermotor Gong Location Manufacturer Model # Size OK ScanID 1st Center Janitor Closet Outside RC Elecln 32459284 Fire & Life Safety America, Inc. - Orlando 8 06/01/2015

Gymnasium A sprinkler system employing automatic sprinklers attached to a piping system containing water and connected to a water supply so that water discharges immediately from sprinklers opened by heat from a fire. Tamper Switch Alarms Type Description Manufacturer Sec Zone/Address OK ScanID OS & Y Supervisory Potter Electric 1 07320166 OS & Y Supervisory Potter Electric 1 07320164 Waterflow Switch Type Manufacturer Model # Sec Size Zone/Address OK ScanID Vane/4'in. strap-on Potter Electric VRS-F 60 1 07320167 Backflow Prevention Components Manufacturer Model # Size Type Service Type Install Date Watts Regulator 007M3 0.75" Double Chk Detector 06/05/2002 Location Water Purveyor Meter Account # Serial Number 120393 Initial Test Check Valve 1 Check Valve 2 Relief Valve Pressure Vacuum Breaker 4.4 2.8 Held At Repairs or Notes Final Test Check Valve 1 Check Valve 2 Relief Valve Pressure Vacuum Breaker Held At Condition of Control Valve 1 Condition of Control Valve 2 Backflow Prevention Manufacturer Model # Size Type Service Type Install Date Watts Regulator 007M1 3/4 Double Check 06/05/2002 Location Water Purveyor Meter Account # Serial Number 46037 Initial Test Check Valve 1 Check Valve 2 Relief Valve Pressure Vacuum Breaker 0 1.8 Held At Repairs or Notes Final Test Fire & Life Safety America, Inc. - Orlando 9 06/01/2015

Check Valve 1 Check Valve 2 Relief Valve Pressure Vacuum Breaker Held At Condition of Control Valve 1 Condition of Control Valve 2 Check Valve Type Location Size OK ScanID Flanged Ground corner of gym near parking lot 4" 28342820 Control Valve Type Manufacturer Size Position Status OK ScanID OS&Y Kennedy 4" Open Locked 07320163 OS&Y Kennedy 4" Open Locked 07320165 Inspector's Test Manufacturer Model # Pressure psi Trip Time Sec Flow Sec OK ScanID NIBCO 32459075 Drain Devices Type Size Supply psi Static psi Residual psi Sec OK ScanID Main 2" 70 50 20 07320170 Fast Response Qty Type Size K factor Manufacturer Location OK ScanID 3 Upright 5.6 Tyco FACP Room 07320179 3 Upright 5.6 Central FACP Room 07320178 3 Upright 5.6 Tyco FACP Room 07320177 Fire Dep't Connection Location Type Size OK ScanID Ground corner of gym near parking lot Freestanding 4" 07320171 Gauge Type Location Static psi Fill Type Size OK ScanID System Pressure Outside riser 70 n/a 1/4 07320169 Sprinkler Box Qty Tool Available? Size Manufacturer Location OK ScanID 6 Yes 6 unit Central FACP Room 07320175 3 Yes 6 unit Central FACP Room 07320176 Fire & Life Safety America, Inc. - Orlando 10 06/01/2015

Inventory & Warranty Report Generated by: BuildingReports.com The Inventory & Warranty Report lists each of the devices and items that are included in your Inspection Report. A complete inventory count by device type and category is provided. Items installed within the last 90 days, within the last year, and devices installed for two years or more are grouped together for easy reference. Device or Item Category % of Inventory Quantity Gauge Device 7.69% 3 Check Valve Valve 5.13% 2 Inspector's Test Valve 5.13% 2 Drain Device 5.13% 2 Sprinkler Box Sprinkler 7.69% 3 Sprinkler Box Spares Sprinkler 5.13% 2 Tamper Switch Alarm 15.38% 6 Control Valve Valve 12.82% 5 Waterflow Switch Alarm 5.13% 2 Watermotor Gong Device 2.56% 1 Post Indicator Valve Valve 2.56% 1 Piping Sprinkler 2.56% 1 Fast Response Sprinkler 7.69% 3 Fire Dep't Connection Hose 5.13% 2 Backflow Prevention Valve 10.26% 4 Device or Item Qty Model # Description Install Date Wet Pipe, 400 In Service - 90 Days - 1 Year Gauge 2 0-300 System Pressure 01/20/2015 Wet Pipe, Gymnasium Gauge 1 System Pressure 01/20/2015 Wet Pipe, 400 In Service - 3 Years to 5 Years Inspector's Test 1 11/03/2011 Post Indicator Valve 1 Ground 11/03/2011 Fire Dep't Connection 1 Freestanding 11/03/2011 Control Valve 2 OS&Y 11/03/2011 Tamper Switch 1 Lever 11/03/2011 Watermotor Gong 1 Elecln 11/03/2011 Tamper Switch 2 Lever 11/03/2011 Waterflow Switch 1 wfd25 Vane 11/03/2011 Sprinkler Box 1 11/03/2011 Sprinkler Box Spares 1 3131 Upright 11/03/2011 Sprinkler Box Spares 1 3231 Pendant 11/03/2011 Drain 1 Main 11/03/2011 Check Valve 1 Grooved 11/03/2011 Control Valve 1 705 Butterfly 11/03/2011 Tamper Switch 1 705 Control Valve 11/03/2011 Fire & Life Safety America, Inc. - Orlando 11 06/01/2015

In Service - 3 Years to 5 Years Backflow Prevention 1 007M3 Double Check 11/03/2011 Backflow Prevention 1 757 Double Check 11/03/2011 Wet Pipe, Gymnasium In Service - 10 Years to 15 Years Check Valve 1 Flanged 06/05/2002 Fast Response 1 C3101 Upright 06/05/2002 Fire Dep't Connection 1 Freestanding 06/05/2002 Sprinkler Box 1 06/05/2002 Sprinkler Box 1 TY 06/05/2002 3231-Chrome Control Valve 2 OS&Y 06/05/2002 Drain 1 Main 06/05/2002 Inspector's Test 1 06/05/2002 Tamper Switch 2 OSYSU-2 OS & Y 06/05/2002 Waterflow Switch 1 VRS-F Vane/4'in. strap-on 06/05/2002 Fast Response 1 TY3131 Upright 06/05/2002 Fast Response 1 TY3231 Upright 06/05/2002 Piping 1 Steel 06/05/2002 Backflow Prevention 1 007M1 Double Check 06/05/2002 Backflow Prevention 1 007M3 Double Chk Detector 06/05/2002 Fire & Life Safety America, Inc. - Orlando 12 06/01/2015

Notes & Recommendations Generated by: BuildingReports.com The Notes & Recommendations Report details additional inspection notes made by the Inspectors during the course of the building inspection. Notes are grouped by SystemID. A link to the item is provided for more information. Note Device Type Location Comment ScanID Wet Pipe, 400 1 Control Valve 1st Center Janitor Closet Passed 28342827 1009632 2 Control Valve Ground West end of classrooms Passed 28342824 1009996 3 Control Valve Ground West end of classrooms Passed 28342825 1009646 4 Post Indicator Valve Ground West end of classrooms Passed 28342822 1009992 Wet Pipe, Gymnasium 5 Control Valve Backflow c.v.2 Leaking 07320165 1009631 Packing and Bolts 6 Control Valve Backflow c.v.1 Passed 07320163 1009647 7 Tamper Switch Backflow c.v.2 Damaged/Worn 07320164 Attaching Bolts Fire & Life Safety America, Inc. - Orlando 13 06/01/2015