OneWireless Gauge Reader WGR400 Series Specifications 34-XY July 2009

Similar documents
STT 3000 Series STT250 /150 Surge Protection Device Specifications

MVX 2000 Multivariable Pressure Transducer. Specifications 34-SM March Introduction. Proven Sensor Technology. Flow Computer Benefits

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

DESCRIPTION FEATURES WARNINGS APPLICATIONS

OneWireless Gauge Reader Application Gateway User's Manual

E + M III. Suitable for interfaces. up to CATEGORY 4 per EN E197638

DCP200 Digital Controller Programmer Specification

CD3000S-2PH. up to 100A

04973 Series Conductivity Cells Installation and Maintenance Manual

4905 Style Conductivity Cells Installation and Maintenance Manual

DCP200 Digital Controller Programmer Specification

Accuracy counts! Sensors with analog output

Beckhoff short profile

Muting function The muting sensors must be able to recognise the passing material (pallets, vehicles, etc.) according to the material's length and spe

DPR100 C/D PEN AND MULTIPOINT 100 mm DIGITAL RECORDERS

XYR 6000 SmartCET Wireless Corrosion Monitoring Transmitter

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

FF-SG Series. Safety light curtain Compact and low-cost unit

DPR MM DIGITAL STRIP CHART RECORDER

BFD Light Curtains The new choice for cutting edge safety for industrial doors

RMA 3000 Remote Meter Assemblies Specifications

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

Return loss measurement of fiber optic components

Installation Instructions

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

International standards used locally worldwide ISO/TC 67

Labeling and Identification Products

Advantages of automatic boiler bottom blowdown

Manusa Automatic. Doors. Safety beyond the Standard. EN16005 Power operated pedestrian doorsets. Safety in use. Requirements and test methods.

PTG, SWT Series. Heat Recovery Systems

ST 3000 Smart Transmitter Series 900 Flush Mount Models Specifications

Compact FREME. flash recovery energy management equipment HEAT TRANSFER SOLUTIONS

DirectLine DL424/425 Sensor Module for DL 5000 Dissolved Oxygen Probes User Manual

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications

Weishaupt WKmono 80. The next-generation burner for ratings up to kw. That s reliability

STANDARD T6 (200 C) SENSOR CABLE RANGE

CRA24-B3 controlled residential ventilation

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

DPR MM DIGITAL STRIP CHART RECORDER

Battery Industry EFFICIENT APPLICATIONS SOLUTIONS

Future development of the furniture industry A look at the next 3-5 years

Signal converters SVE4 Product overview

Value engineering developed from global experience

The advantages of closed heating systems. White paper

KNX The worldwide STANDARD for home and building control. KNX Association International

E-T-A Get Smart With Your Systems

Operation Manual Part-No

International Product Compliance and Certifications. Product Safety Consulting, Inc.

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

For more information on Tarkett go to

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

stylemakerstm SINCE 1895

Fire-Resistant. Automatic Doors

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

FieldLink Cable solutions for Automation & Drives

OO Measuring range from bar rel. OO Large selection of pressure sensors. OO Automatic sensor recognition

N02 Remote control transmitter

AutoM Click to go to the page. AutoM Auto Shaker Filter

ST 3000 Smart Pressure Transmitter Quick Start Installation Guide 34-ST Revision 9 July 2011

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

A WMIA Partner of the Year Winner S-Series Enclosureless Dust Collector

A revolutionary development designed for expansive and connected living.

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

NETWORKING AND INTEGRATION

COOL 1. Service manual

AIR HEATING PRODUCTS

Detect. React. Benefit. Increase the availability of your plants with SIMATIC Notifier!

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

BA2702-P Linear Actuator

Premium freezers combining functionality, elegance and energy efficiency

A2, A6 PEK Control Unit

Waterpik Water Flosser Model WP-450/462/ 463/465/470

Foreword. A completely revised report for quicker and easier access to key information

micropac. Personal Gas Detection Instruments

Figure 1 TWM1000 Electromagnetic Flow Converter. 1. Large, illuminated graphic display with intuitive operation 2. For AC and DC operation

Wireless Panel-Mount Monitor

Expansion vessel in a solar installation. White paper

SUNSTAR 传感与控制 The main features are: - COMPACT SIZE The cross section of 4 mm x 55 mm /.65 in x.6 in makes installation poss

SBA Profile. Privacy Statement (Back to Profile List, or use Back button) Identification, Location & Contacts

Certificate of constancy of performance,


Waterpik Water Flosser Model WF-02

Waterpik Water Flosser Model WF-06

KNX The worldwide STANDARD for home and building control. KNX Association International

VersaFlow Mag 2000 FL Electromagnetic Flow Sensor Technical Datasheet. Specification. Solution with high-tech ceramics. Highlights.

DirectLine DL421 Sensor Module for ph Measurements User Manual

30th. English. Anniversary Since 1980 RICH. Heat & Cool molding system RICH-2. ZICUL (Chiller) WATER PURIFIER

Nationwide Footprint International Reach

Waterpik Water Flosser Model WP-150/152

Contents. +0 % VS 2016 On page 1 you will find the key indicators at a glance : chains in the country: 2016 and 2017 sales, number of stores,,

L-force Drive-based Safety. Safe, scaleable and above all integrated

WELCOME. Elektronische Bauelemente GmbH

TA-SCOPE. Balancing instrument ENGINEERING ADVANTAGE

Security Trade Control by a Japanese company. 20 July, 2017 Shozo HIRATA NEC Corporation

Rotary Screw Compressors SXC»Compact«Series

The best in connector value... today, tomorrow and into the future!

Motor Kit for SW Shutter. Instruction Manual. Motor Kit for SW Shutter. Models: FA2685. Munters Corporation, November 2013 QM1017r6

Transcription:

OneWireless Gauge Reader WGR400 Series Specifications 34-XY-03-37 July 2009 Introduction The OneWireless Gauge Reader (WGR) is a battery powered wireless device that is used to monitor analog dial gauges. The non-invasive WGR mounts to a gauge, and converts the analog needle position into a digital reading. The WGR displays the digital reading on an LCD, and transmits the reading to a Honeywell OneWireless Multinode or the Application Gateway. Features Compatible with most circular gauges from 1.5 in 4.5 in (38 mm 114 mm) diameter Large LCD display showing reading, units, bar graph, battery level, and wireless status Easy, non-invasive installation, with no process down-time or re-qualification Self powered, with long battery life Long range reliable wireless communication High reading accuracy IP66 rated, chemical-resistant enclosure Wide operating temperature range Application The OneWireless Gauge Reader is used in conjunction with the Honeywell wireless network access units, OneWireless Multinodes and the OneWireless Application Gateway to form a complete end-to-end solution. Up to 1,000 WGRs can communicate with a single Application Gateway. The OneWireless Gauge Reader is intended to automate the monitoring of conventional analog gauges, such as pressure and temperature gauges. Many of these gauges are manually monitored infrequently. The WGR provides automated, more frequent gauge monitoring. It is a battery powered device intended for sample rates that range from 1 sample per minute to 1 sample per 18 hours. The battery powered WGR is not intended to be used in high update-rate mission-critical closed-loop control systems.

2 OneWireless Gauge Reader LCD Display and Push Buttons A B C D E G F H I J A. SAMPLE Icon Displayed when a new reading is being captured and converted B. ERROR Icon: Displayed when an error condition is detected C. Bar Graph Indicates percent of full-scale reading D. Numeric Display Displays the converted reading value E. Antenna Icon Displayed when a wireless connection has been established F. Battery Level Displays percentage of battery life remaining G. Alpha-numeric Display Displays the reading units or diagnostic messages H. Left Button Left or escape button, depending on menu context I. Center Button Select/Enter/Sample button, depending on menu context J. Right Button Right button to navigate through LCD menus

OneWireless Gauge Reader 3 Product Specifications Test conditions: ambient temperature = 25C, humidity = 20%, new battery Parameter Min Typical Max Mechanical Gauge Mounting Interchangeable modular ABS interface adapters with removable 316 stainless steel clamps Circular Gauge Size Compatibility (diameter) Circular Gauge Type Compatibility Enclosure Material Enclosure Ratings Weight with batteries, not including mounting adapter Water / Dust rating Length Width Height Shock Resistance (per IEC 770) Vibration Resistance (per IEC 770) 1.5 in (38 mm) - 4.5 in (114 mm) Single needle; Conventional pressure or temperature; Process gauges; Magnehelic, Photohelic; Stand-alone and panel-mounted gauges. Main housing is ABS with UV and Flame Retardant inhibitors; Clear windows are Polycarbonate; Gasket seals are silicone Housing Fire Rating of UL 94-5 VA to V-0; Window seal UL 94 V-0 8 oz (230 g) IEC IP66 compliant (outdoor, dust-proof, water-resistant) 2.55 in (65 mm) 2.55 in (65 mm) 1.3 in (33 mm) 10 G Operating, 20 G Non-Operating 4 G RMS from 150 to 2000 Hz Electrical Display Type FSTN segment LCD *Battery Life (@ 1 sample per minute) 2 months (@ -20 C) 4 months - *Battery Life (@ 1 sample per 5 minutes) 0.5 years (@ -20 C) 1 year - *Battery Life (@ 1 sample per 15 minutes) 1 year (@ -20 C) 2 years - *Battery Life (@ 1 sample per 18 hours) 1.5 years (@ -20 C) 3 years - Internal Battery Voltage 2.2 V 3.0 V 3.3 V * Expected battery life can be affected by several factors, including specific image capture and processing configuration settings, as well as security key update rates. For Magnehelic and Photohelic gauge reader models (WGR421, WGR422), the battery life is impacted by the LED brightness configuration setting, and will typically be 10% lower than the other gauge reader models.

4 OneWireless Gauge Reader Product Specifications.. continued Test conditions: ambient temperature = 25 C, humidity = 20%, new battery Parameter Min Typical Max General Functionality Sample Rate in Normal Mode 1 sample/min - 1 sample/18 hours Sample Rate in Diagnostic Mode 12 samples/min @ 15 C-70 C 4 samples/min @ -20 C Resolution +/-0.4% of full scale Full-Scale Reading Accuracy +/-1.5% LCD Horizontal Viewing Angle -45 degrees - +45 degrees LCD Vertical Viewing Angle -45 degrees - +45 degrees Operating Temperature -20 C - +70 C Storage Temperature -40 C - +85 C Operating Humidity % RH 0-100 Hazardous Location Certifications WGR-400-XXX-XXX versions are non classified Parameter Min Typical Max Wireless Wireless Communication 802.11 b/g compliant; Direct Sequence Spread Spectrum Data Rate and Modulation 1-2 mbps; BPSK, QPSK Antenna Integral 2 dbi Security / Encryption Uses 802.11i security protocols, including WEP-128; WPA-PSK; WPA2-PSK; TKIP; CCMP; RF Transmitter Power (USA & Canada) 100mW (20dBm) maximum EIRP per FCC/IC not including antenna, or 158mW (22dBm) maximum EIRP including antenna RF Transmitter Power (Europe) 100mW (20dBm) Maximum per RTTE/ETSI including antenna Wireless Communication Frequency Band US 2.412 GHz to 2.462 GHz Europe 2.412 GHz to 2.472GHz Nominal 1,000 ft. (300 m) between the WGR and Infrastructure Communication Range for Single Hop Unit (Multinode) or Gateway Unit with a clear line of site. Actual range will vary, depending on antennas and site topography. Compliance Category Country Compliance Body Compliance Standard US OSHA UL 60950-1 Canada CSA CSA C22.2 No. 60950-1 Europe CE EN/IEC 60950-1 US FCC 15.107,15.109 EMI Susceptibility Canada IC ICES-003 EN 301 489-1 with Europe ETSI EN300 328-2 EN 310 489-17. US FCC FCC 15.247 Radio Approvals Canada IC RSS-210 Europe ETSI EN 300 328-2

OneWireless Gauge Reader 5 Ordering Information Model Selection Guide

6 OneWireless Gauge Reader Model Selection Guide.. continued

OneWireless Gauge Reader 7 Model Selection Guide.. continued Mounting Adapter Size Reference Dimensions Adapter size ID @ Gauge Interface Max OD of Gauge Min OD of Gauge Mini 1.955 in 1.995 in 1.600 in [ 49.66 mm] [ 50.67 mm] [ 40.64 mm] Small 2.350 in 2.390 in 1.995 in [ 59.69 mm ] [ 60.71mm ] [ 50.67 mm ] Medium 2.782 in 2.822 in 2.390 in [ 70.66 mm ] [ 71.68 mm ] [ 60.71mm ] Large 3.245 in 3.285 in 2.820 in [ 82.42 mm ] [ 83.44 mm] [ 71.63 mm] Extra Large 3.675 in 3.715 in 3.285 in [ 93.35 mm] [ 94.36 mm] [83.44 mm] Grande 4.083 in 4.123 in 3.715 in [ 103.71mm] [104.72 mm] [94.36 mm] Extra 4.600 in 4.680 in 4.181 in Grande [116.84 mm] [118.87 mm] [106.20 mm]

8 OneWireless Gauge Reader Mechanical Dimensions Inches (millimeters) No Adapter

OneWireless Gauge Reader 9 Mini Adapter

10 OneWireless Gauge Reader Small Adapter

OneWireless Gauge Reader 11 Medium Adapter

12 OneWireless Gauge Reader Large Adapter

OneWireless Gauge Reader 13 Extra Large Adapter

14 OneWireless Gauge Reader Grande Adapter

OneWireless Gauge Reader 15 Extra Grande Adapter

16 OneWireless Gauge Reader Magnehelic Adapter

OneWireless Gauge Reader 17 Photohelic Adapter

18 OneWireless Gauge Reader Process Gauge Adapter

OneWireless Gauge Reader 19 Sales and Service For application assistance, current specifications, pricing, or name of the nearest Authorized Distributor, contact one of the offices below. ASIA PACIFIC Control Products Asia Pacific Headquarters Phone: +(65) 6355-2828 Fax: +(65) 6445-3033 Asia Pacific Global Technical Support Field Instruments Phone: +65 6580 3156 Fax: +65 6445-3033 Process Instruments Phone: (603) 76950 4777 Fax: (603) 7958 8922 Australia Honeywell Limited Phone: +(61) 7-3846 1255 FAX: +(61) 7-3840 6481 Toll Free 1300-36-39-36 Toll Free Fax: 1300-36-04-70 China PRC - Beijing Honeywell China Inc. Phone: +(86-10) 8458-3280 Fax: +(86-10) 8458-4650 China PRC - Shanghai Honeywell China Inc. Phone: (86-21) 5257-4568 Fax: (86-21) 6237-2826 China PRC - Chengdu Honeywell China Inc. Phone: +(86-28) 8678-6348 Fax: +(86-28) 8678-7061 China PRC - Xi an Honeywell China Ltd - Xi an. Phone: +(86-29) 8833-7490 Fax: +(86-29) 8833-7489 China PRC - Shenzhen- Honeywell China Inc. Phone: +(86) 755-2518- 1226 Fax: +(86) 755-2518-1221 Indonesia PT Honeywell Indonesia Phone: +(62) 21-535-8833 FAX: +(62) 21-5367 1008 India Automation India Ltd. Honeywell Ltd. Phone:+(91) 5603-9400 Fax: +(91) 5603-9600 Japan Honeywell Inc. Phone: +(81) 3 6730 7150 Fax: +(81) 3 6730 7228 Malaysia Honeywell Engineering Sdn Bhd Phone: +(60-3) 7950-4776 Fax: +(60-3) 7958-8922 New Zealand Honeywell Limited Phone: +(64-9) 623-5052 Fax: +(64-9) 623-5060 Toll Free (0800) 202-088 Philippines Honeywell Systems (Philippines) Inc. Phone: +(63-2) 633-2830- 31/ 636 1661-62 Fax: +(63-2) 638-4013 Singapore Honeywell Pte Ltd. Phone: +(65) 6580 3278 Fax: +(65) 6445-3033 South Korea Honeywell Korea Co Ltd Phone: +(822) 799 6315 Fax: +(822) 792 9015 Thailand Honeywell Systems (Thailand) Ltd. Phone: +(662) 693-3099 FAX: +(662) 693-3089 Taiwan R.O.C. Honeywell Taiwan Ltd. Phone: +(886-2) 2245-1000 FAX: +(886-2) 2245-3241 SE Asia Countries see Honeywell Pte Ltd (Singapore) for: Pakistan, Cambodia, Guam, Laos, Myanmar, Vietnam, East Timor SE Asia Countries see Honeywell Automation India Ltd for: Bangladesh Nepal Sri Lanka EUROPE Austria Honeywell Austria GmbH Phone: +43 (316)400123 FAX: +43 (316)40017 Belgium Honeywell SA/NV Phone: +32 (0) 2 728 24 07 FAX: +32 (0) 2 728 22 45 Bulgaria Honeywell EOOD Phone: +(359) 2 40 20 900 FAX: +(359) 2 40 20 990 Czech Republic Honeywell spol. s.r.o. Phone: +420 242 442 232 FAX: +420 242 442 131 Denmark Honeywell A/S Phone: +(45) 39 55 55 55 FAX: +(45) 39 55 55 58 Finland Honeywell OY Phone: +358 (0)20752 2753 FAX: +358 (0) 20752 2751 France Honeywell SA Phone: +33 (0)1 60198075 FAX: +33 (0)1 60198201 Germany Honeywell AG Phone: +49 (69)8064-299 FAX: +49 (69)806497336 Hungary Honeywell Kft. Phone: +36-1-451 4300 FAX: +36-1-451 4343 Italy Honeywell S.p.A. Phone:+390292146307 FAX: +39 0292146377 The Netherlands Honeywell B.V. Phone: +31 (0) 20 5656200 FAX: +31 (0) 20 5656210 Norway Honeywell A/S Phone: (45) 39 55 55 55 Poland Honeywell Sp. zo.o Phone: +48-22-6060900 FAX: +48-22-6060901 Portugal Honeywell Portugal Lda Phone: +351 21 424 5000 FAX: +351 21 424 50 99 Romania Honeywell Bucharest Phone: +40 (0) 21 2316437 FAX: +40 (0) 21 2316439 Russian Federation (RF), ZAO "Honeywell" Phone: +7 (095) 796 98 00 FAX: +7 (495) 797 99 64 Slovak Republic Honeywell s.r.o. Phone: +421-2-58247 410 FAX: +421-2-58247 415 Spain Honeywell S.A. Phone: +34 (0)91313 61 00 FAX: +34 (0)91313 61 30 Sweden Honeywell AB Phone: +(46) 8 775 55 00 FAX: +(46) 8 775 56 00 Switzerland Honeywell AG Phone: +41 18552448 FAX: +(41) 1 855 24 45 Turkey Honeywell Turkey A.S. Phone: +90 216 578 71 00 FAX: +90 216 575 66 35 Ukraine Honeywell Tel: +380-44-201 44 74 Fax: +380-44-201-44-75 United Kingdom Honeywell Control Systems Ltd. Phone: +44 (0)1344 655251 FAX: +44 (0) 1344 655554 MIDDLE EAST Abu Dhabi U A E Middle East Headquarters Honeywell Middle East Ltd. Phone: +971 2 4041246 FAX: +971 2 4432536 Sultanate of Oman Honeywell & Co Oman LLC Phone: +968 24 701153/ Ext.33 FAX +968 24 787351 Saudia Arabia Honeywell Turki Arabia Ltd Jubail Office Phone: +966-3-341-0140 Fax: +966-3-341-0216 Honeywell - ATCO Dammam Office Phone: 0096638304584 Fax: 0096638338059 Kuwait Honeywell Kuwait KSC Phone: +965 242 1327 to 30 Fax: +965 242 8315 And Phone: +965 326 2934/1821Fax: +965 326 1714 AFRICA Mediterranean & African Distributors Honeywell SpA Phone: +39 (02) 250 10 604 FAX: +39 (02) 250 10 659 South Africa (Republic of) and sub saharan Honeywell Southern Africa Honeywell S.A. Pty. Ltd. Phone: +27 11 6958000 FAX +27 118051504 NORTH AMERICA Canada Honeywell LTD Phone: 1-800-737-3360 FAX: 1-800-565-4130 USA Honeywell Process Solutions, Phone: 1-800-343-0228 FAX: 1-717-771-8251 Email:sc-cpappssales@ honeywell.com LATIN AMERICA Argentina Honeywell S.A.I.C. Phone: +(54-11) 4383-3637 FAX: +(54-11) 4325-6470 Brazil Honeywell do Brasil & Cia Phone: +(55-11) 7266-1900 FAX: +(55-11) 7266-1905 Chile Honeywell Chile, S.A. Phone: +(56-2) 233-0688 FAX: +(56-2) 231-6679 Mexico Honeywell S.A. de C.V. Phone: +(52) 55 5259-1966 FAX: +(52) 55 5570-2985 Puerto Rico Honeywell Inc. Phone: +(809) 792-7075 FAX: +(809) 792-0053 Trinidad Honeywell Inc. Phone: +(868) 624-3964 FAX: +(868) 624-3969 Venezuela Honeywell CA Phone: +(58-2) 238-0211 FAX: +(58-2) 238-3391

20 OneWireless Gauge Reader For More Information Learn more about how Honeywell s OneWireless Gauge Reader can increase performance, reduce downtime and decrease configuration costs, visit our website www.honeywell.com/ps or contact your Honeywell account manager. Automation & Control Solutions Process Solutions Honeywell 2500 W. Union Hills Drive Phoenix, AZ 85027 Tel: 877.466.3993 or 602.313.6665 www.honeywell.com/ps 34-XY-03-37 July 2009 2009 Honeywell International Inc.