Tek-ENTRY Telephone Entry System

Similar documents
Hazardous Area Ringdown Telephone

INSTALLATION MANUAL PC25OO

GE Security Fire & Life Safety F-DACT(F) Digital Alarm Communicator Transmitter Installation Sheet

Tek-COM Home Intercom System. Specification Sheets Submittal Package as of 8/06/2002. Website:

CM800 Emergency Call System

Rev C May GE Interlogix. Part No: R. CareGard. User Guide

D169 2-Way Voice Verification Module. Installation and Operating Manual Radionics 34105B 3/97

3226 Trunk Port FXO Doorphone

INSTALLATION, PROGRAMMING, and TROUBLESHOOTING MANUAL

INSTALLATION INSTRUCTIONS TALKBACK MODULE

Alarm Tone Generator Model AG17

FreezeAlarm. General Description FA-D /FA-D-AAB. Applications. Features. Specifications. Dimensions

Tek-SAFE Area of Rescue Assistance System

Tek-ENTRY Apartment Entry Systems

AMERIPHONE products are manufactured by Walker, A Division of Plantronics, Inc Western Avenue, Garden Grove, CA (800) VOICE

Interrogator 200 Audio Verification Module (AVM)

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Computer Room Guard Model VM Manual and Installation Instructions

Tek-ENTRY Vandal-Resistant Apartment Entry Systems

OUT TO WALLJACK. Input

TX3 Series TELEPHONE ACCESS SYSTEM. User Guide - Keypad Configuration

United Security Products Model AVD-45b Automatic Voice Dialer Installation and Instruction Manual

NetworX Series NX-870E Fire Supervision Module Installation and Startup

DYGIZONE GJD910 Lighting Controller & Enunciator

INSTRUCTION MANUAL PC255O

8VHU*XLGH K4254V3 6/01

PC4020 v3.2 Instruction Manual

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

User s Manual. System Information... 3 Using the Touchpad Buttons... 3 General Operation... 4 Using Systems with Keyswitches... 4

Quick start guide. SB3014-WM DECT 6.0 expansion wireless mic for use with AT&T model SB3014

Installation & Operations Manual

Supervised Security System Owner's Guide

TABLE OF CONTENTS TABLE OF CONTENTS 1

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

FUTURE CALL. Loud Ringer Light Box FC OWNER S MANUAL AND OPERATING INSTRUCTIONS

INSTRUCTION MANUAL PC255O

AXI LED USER MANUAL (REV. 1.0)

Independent Zone Control (I.Z.C.)

Tek-ENTRY Vandal-Resistant Apartment Entry Systems. Specification Sheets Submittal Package. as of 03/24/2009. Website:

SENSAPHONE. Model User s Manual. Version 1.11 SENSAPHONE, INC.

Tek-ENTRY Vandal-Resistant Apartment Entry Systems

Technical Manuals Online! A B C DEF GHI JKL POWER 9 0 COMMAND YZ. User's Guide

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

INSTALLATION INSTRUCTIONS UNIVERSAL TELEPHONE ALERT

AVS Audio Verification System

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

Home Doorway Alert Kit

RONDISH DoorWatcher EASY INSTALL STRIP DOOR MONITOR

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

RMS/RPX Reader. User Manual

Voice Dialer. Manual E-921CPQ E-921KPQ

Destiny Destiny Owners Manual

FreezeAlarm Dialer FA-700 Installation and Operations Manual

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

KT-100 Door Controller

1. Introduction. 1.1 Features

IL650 SECTION B Rev. 5-01/2002. Tek-SPEC Condensed Product Specification Catalog. Section B Residential & Commercial Intercoms

636 and 646 Keypads. User s Manual

GT-1D. Residential/Tenant Station OPERATION MANUAL

Voice Module Installation Guide. For use with ProSYS 16, ProSYS 40, ProSYS 128

Norstar. Doorphone User Guide

EVO192 v3.0 Fire and Burglary What s New

HARDwired Installation/ Owner s Manual

Personal Assistance System Owner s Manual

TX3 Series TELEPHONE ACCESS SYSTEMS. Programming Manual

PROGRAMMING WORKSHEETS

L900 series USER MANUAL

TELEMERGENCY 750C USER MANUAL SIMPLE AUTOMATIC SYSTEM PREPARES YOUR HOME FOR ANY EMERGENCY. Consumer Helpline

Version 1.03 January-2002 USER S MANUAL

FreezeAlarm Dialer Pro

Auto Dialer. Manual E-921APQ E-921GPQ

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

AXS Strikemaster Engineering Manual

Dual Alarm Clock with Wireless Alarm Monitoring Receiver

l 02-April-2010 For INSTANT CARE

INSTALLATION MANUAL & PROGRAM RECORD SHEET

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Basic Installation Manual

Installation/Owner s Manual Models 1504 / 1506

Installation and ZONES: Operation Manual. Model: ON STI-34108

ADE Gen4. Speech Dialler Engineering Information. Description. Features

Chapter 1: Introduction. OMEGAPHONE OMA-P1104 User s Manual

Public Safety DAS Annunciator Panel

User's Manual 5120XM N8031 6/96

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

DESTINY OWNER S MANUAL

TECHNICAL. Voice Alarm Dialing or Store Caster Announcements from up to Eight Inputs. K-2000-DVA Multi-Input Voice Dialer/Announcer

AT60 AUTO DIALLER User Guide

WM3000 WIRELESS MODULES

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Installation Instructions

Model SS2000C31 SmartSystem Load Management System

D2071A. Operation & Installation Guide Fire Alarm Control Panel

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Contents. Glossary

READ ME FIRST DIY WIRELESS ALERT. Gate Alert Kit. Instruction Manual

E N G L I S H SUPER PHONE RINGER MODEL SR-200 & SR-95 E S P A Ñ O L F R A N Ç A I S. Users Guide SR200 M52002 A 4/03

Transcription:

IL574 SECTION A Rev. 13-07/2005 Tek-ENTRY Telephone Entry System No-Phone-Line Version Operation, Installation and Service Manual Website: www.tektone.net Email: tektone@tektone.net For Technical Assistance: 1-800-332-6608 Technical Assistance Email: teksupt@tektone.net 277 Industrial Park Road Franklin, NC 28734 (828) 524-9967 (800) 327-8466 Fax (828) 524-9968

Operation, Installation and Service Manual Copyright 2002 2005 TekTone Sound & Signal Mfg., Inc., All rights reserved. No part of this publication may be copied without the express written permission of TekTone Sound & Signal Mfg., Inc. The content of this manual is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by TekTone Sound & Signal Mfg., Inc. TekTone Sound & Signal Mfg., Inc. assumes no responsibility or liability for any errors or inaccuracies that may appear in this documentation. TekTone, the TekTone logo, Tek-Call, Tek-Care, Tek-Check-In, Tek-Com, Tek-Digicare, Tek-Door, Tek-Entry, Tek-Guard, Tek-Micro, Tek-MMARS, TekNIOS, TekNIOS, Tek-Paging, Tek-Phone, Tek-Safe, Tek-Select, Tek-Sentry, Tek-Sound, Tek-Status, Tek-Trio and Tek-View are either registered trademarks or trademarks of TekTone Sound & Signal Mfg., Inc. in the United States and/or other countries. All other trademarks are the property of their respective owners. TekTone Sound & Signal Mfg., Inc., 277 Industrial Park Road, Franklin, North Carolina 28734, USA. ii IL574 Tek-ENTRY III No-Phone-Line Version Manual Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Table of Contents System Introduction... 1 General Features... 1 Special Features... 1 Postal Service Lock... 1 Door Timer Cut-Off (Tailgate Prevention)... 1 Fire Alarm (Emergency) Input... 1 Multiple Entrances... 1 Night Service... 1 Wiegand Data Output... 2 Guard Telephone... 2 Call Waiting... 2 System Installation and Programming...3 Installation Tips... 3 Lobby Equipment Installation... 3 Electrical Room Equipment Installation... 5 System Programming and Settings... 5 Program Mode Begin/End... 7 To Program Codes (Tenant Dial Codes) Manual Method... 7 To Program Codes (Tenant Dial Codes) Automatic Method... 7 Program Keyless Entry Codes... 7 View Keyless Entry Codes... 8 New Master Code... 8 Door Open Time... 8 Talk Time... 8 Pulse or Tone Dialing... 8 Off-Premises Dialing... 9 Erase/Reset to Factory Default... 9 Adjustments... 9 Volume Control... 9 Rotary Phone Pulse Sensitivity... 9 Notice to U.S. Installers and Users... 10 Notice to Canadian Installers and Users... 11 Illustrations Figure 1 System Wiring Diagram... 4 Figure 2 Hands-Free Panel Wiring Diagram... 6 Figure 3 Handset Panel Wiring Diagram... 6 Figure 4 PM900 Control Unit Mounting Template... 12 Figure 5 Frame and Housing Installation... 13 Figure 6 Amphenol PIN Assignment, Bell Side (RJ71C, CA79X, CA71A)... 14 Worksheets Programming Worksheet... 15 Directory Worksheets... 16 18 Tek-ENTRY Telephone Entry System Operating Instructions...19 Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved. IL574 Tek-ENTRY III No-Phone-Line Version Manual iii

System Introduction General Features Tek-ENTRY Telephone Entry Systems are designed for easy operation and accommodate 1 1000 suites. The no-phone-line system has many sophisticated features built in, such as:: No monthly rental bill for telephone line. Call waiting with distinctive double tone. Distinctive double ring differentiates visitor calls from incoming calls. All programming is done via the system keypad. EEPROM Memory retains programmed information during total power failure. Two programmable relay outputs control door strikes, gates, cameras, etc. System operates with both touchtone and rotary pulse phones. Door open tone for both tenant and visitor. Warning tone to alert tenant that call will end in 10 seconds. Automatic call termination after 8 seconds of dial tone detection. Variable tenant code length: 1, 2, 3 or 4 digits. Night service feature transfers calls to the guard or manager telephone. One keyless entry code per tenant, plus five for use by building management. Built-in multiple entrance capability (maximum 20). Tenant codes can be actual suite numbers or coded for security purposes. Dial up to five off-premises telephones (when connected to a telephone line). Special Features Postal Service Lock Provision for the installation of a postal service lock is available on the rear of the system enclosure s control panel. Door Timer Cut-Off (Tailgate Prevention) This feature requires the installation of a Normally Open switch contact that closes when the entry door has been opened. A magnetic contact, as used in security systems, is acceptable for this application, provided that it is a Normally Open type. (Most security door contacts are of the Normally Closed type.) When the electric door strike is released, the door remains open for the period of time that has been programmed. When the door timer cut-off feature is used, the door strike de-energizes as soon as the system senses that the entry door has been opened. This causes the door to lock when it closes, regardless of the programmed time. The door strike is therefore energized only as long as necessary, to prevent unauthorized entry of individuals who follow behind the visitor (tailgating). Fire Alarm (Emergency) Input Connecting a Normally Open alarm contact from the building fire alarm system causes the electric door strike to pulse on and off in the event of a fire (emergency) situation. This effectively leaves the entry door unlocked for the duration of the emergency. Multiple Entrances Accommodating multiple entry doors is a built-in feature of the Tek-ENTRY Telephone Entry Systems. Up to 20 entry systems can be interconnected without additional switching equipment. One additional pair of wires, parallel connected to terminals ME and G of all entry systems, is required. When one entry panel is in use, the other panels are temporarily disabled and display a SYSTEM IN USE message. (NOTE: Each entry panel must be independently powered and programmed.) Night Service This feature redirects all entry system calls to a pre-designated telephone line (guard phone). When this feature is enabled (by entering *456 ), the entry system displays the Night Service On message. To return to normal operation, re-enter *456. (The predesignated telephone line must be connected to relay #0000 located on relay board #1.) Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved. IL574 Tek-ENTRY No-Phone-Line Version Manual 1

System Introduction Wiegand Data Output This feature connects Tek-Entry to a card access system with a Wiegand 26-bit input. When a tenant approves a visitor, the tenant s code is sent to the card access system, causing the door to open. Guard Telephone The guard telephone must be a standard touchtone (DTMF) phone, and is connected directly to the PM900 Control Unit via two conductors. To communicate with a tenant, the guard must wait for a dial tone and then enter the tenant s 4-digit relay number. (The guard will not receive a dial tone while the lobby panel is in use.) To dial an off-site telephone, dial 9, wait for a dial tone, and then dial the desired telephone number. Conversation time is limited to 100 seconds. NOTE: Dialing an off-site telephone uses requires a telephone line to be connected directly to the PM900 Control Unit. Because it is used infrequently and only for short periods of time, this does not need to be a dedicated telephone line it can be shared with an office phone, for example. The same line is also used to dial up to five offpremises phone numbers from the entry panel, if programmed. Call Waiting If a tenant is on the telephone when called from the lobby panel or guard telephone, they will hear a double tone to announce the visitor. Depress the hook switch to place the outside call on hold and speak with the visitor. Depress the hook switch again to switch back to the outside call. 2 IL574 Tek-ENTRY No-Phone-Line Version Manual Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

System Installation and Programming Installation Tips 1. Make arrangements with the telephone company to install CA71A or equivalent telephone blocks (one block for every 12 tenant phone lines). 2. Three 16 volt/40 VA UL Listed and CSA approved Class 2 power transformers are required one for the lobby equipment, one for the electrical room equipment, and one for the door strike. 3. An additional transformer is required for door strike activation. This transformer should have the necessary voltage and current rating for the door strike that is to be used (max. 28 volts, 3 amps). 4. Transformers and remote devices such as the door strike, fire alarm and door contacts must be wired to the system controller located in the enclosure housing. A wiring channel at the rear of the system enclosure must be provided for these devices. Follow local building code requirements for low voltage wiring. 5. If a postal service lock is to be installed, make arrangements with the local post office to supply the lock. 6. In multiple entrance applications, two additional wires are required from each entry system to interconnect the system controllers (see Figure 1 System Wiring Diagram). 7. Do not mount the entry panel in an area where it may be exposed to near-horizontal water or moisture sources, for example driving rain or water spray. Lobby Equipment Installation Refer to Figure 1 System Wiring Diagram for terminal locations. Also refer to Figure 2 Hands-Free Panel Wiring Diagram and Figure 3 Handset Panel Wiring Diagram. 1. Mount the system enclosure to the wall in the location closest to the building s controlled entry point. (Refer to Figure 5 Frame and Housing Installation.) 2. Connect the door strike wires to terminals D1 and D2 if DC (silent) operation is desired, or to terminals D3 and D4 for AC (buzzing) operation. The maximum switched door strike load is 28 volts at 3 amps. 3. An auxiliary switched device (such as parking gate) may be controlled through the auxiliary relay contact that is available by connecting to terminals NC (normally closed), C (common), and NO (normally open). The maximum switched auxiliary load is 28 volts at 3 amps. This contact will change to the energized state for one second when the tenant dials 6 from their DTMF (touchtone) telephone. 4. Terminal PL is for the postal service lock. Closing of a normally open switch between terminals PL and G is required for activation. The system is pre-wired for this service, but requires a lock to be installed on the rear of the system control panel (optional on TE905ANP). Remove the panel plug button for the postman s key and wire to the terminals. Mount the lock with the supplied hardware. Adjust the switch actuator for proper operation with the lock. 5. Terminal TC is for connection of a door timer cut-off contact. A normally open contact that closes when the door has been opened will cut-off the door timer and instantly re-lock the door. This is used to prevent tailgating of unwanted visitors through the entry doors. Connect between terminals TC and G. 6. Terminal FA is for connection to the building fire alarm system. A normally open alarm contact that closes during an alarm condition can be connected between Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved. IL574 Tek-ENTRY No-Phone-Line Version Manual 3

Figure 1 System Wiring Diagram PM900 CONTROL UNIT WITH CABINET IH996 RELAY BOARD W/CABINET IH996 RELAY BOARD W/CABINET RED SUPPLIED CABLE RED RED SUPPLIED CABLE TO NEXT IH996 JP1 J9 J10 EARTH T R T R T R ME 16 VAC CMN EARTH RES CO RES CO DATA CLOCK LATCH + - - + LOBBY GUARD OUTSIDE RING 22 VDC LATCH CLOCK DATA RES CO RES CO EARTH - + LATCH CLOCK DATA CO RES EARTH 22 VDC RING 22 VDC RING PHONE LINE CO RES 2 X #18 AWG TO NEXT IH996 #18 AWG MIN SYSTEM TRANSFORMER 16 VAC/40 VA CONNECT TO BUILDING GROUND 120 VAC 2 X #22 AWG UP TO 1000 FEET OPTIONAL GUARD TELEPHONE DTMF (TONE) ONLY 10 WIRES #22 AWG UP TO 1000 FEET IL574 Fig1 System Wiring Diagram Rev4 060503 1 Optional: Connect transformer (use AC cord) to PK250 instead of 120 VAC line voltage. In turn, connect PK250 to 120 VAC line voltage. DO NOT connect transformer to PK250 and 120 VAC. PK250 UPS Back Up PK250 UPS 120 VAC 120 VAC Back Up T1 T2 T3 T4 18 AWG 16 VAC 18 AWG 120 VAC SYSTEM POWER 16 VAC 20 VA DOOR STRIKE TRANSFORMER 120 VAC DOOR STRIKE TRANSFORMER MUST BE COMPATIBLE TO STRIKE 2 X #22 AWG UP TO 1000 FEET POLARITY IS NOT IMPORTANT CONNECT DOOR STRIKE TO D.C. OR A.C. OUTPUTS. MAXIMUM OUTPUT 18 AWG DOOR STRIKE D1 D.C. (SILENT) + DOOR STRIKE - D2 D3 D4 IS 28V, 3AMP. A.C. (BUZZING) DOOR STRIKE NOTE: FOR BATTERY BACKUP OF DOOR STRIKE, PROVIDE BATTERY AND CHARGER APPROPRIATE FOR STRIKE VOLTAGE AND CURRENT NO C AUXILIARY RELAY MOMENTARY CONTACT N.O. SWITCH POSTAL LOCK DOOR TIMER CUTOFF COMMON FIRE ALARM INPUT MULLE ENTRANCE TO SYSTEM NC PL TC G FA ME POSTAL LOCK N.O. SWITCH FIRE ALARM N.O. CONTACT MULLE ENTRANCE TO NEXT TELEPHONE CONTROLLER SYSTEM. (G TO G & ME TO ME) Notes: 1. Transformer must be compatible with door strike. 2. For multiple entrances, connect Terminal G to G and Terminal ME to ME of next entry system. 3. Use supplied cable to interconnect cabinets as shown. For longer distances, connect wiring to terminal blocks. Do not use both. CONTROLLER R T D1 D0 G Wiegand Output Format: 26 bit Wiegand Voltage: 5 VDC Open Collector: No Pulse: 50 usec. Duration: 1 msec. 4 IL574 Tek-ENTRY No-Phone-Line Version Manual Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

System Installation and Programming terminals FA and G to pulse open the entry door during a fire or other emergency. 7. Terminal ME is the interconnect point for multiple entrance systems. Interconnect terminals ME and G of all entry systems. Each location must also be wired with its own transformer, door strike, switch contacts, etc., as shown on Figure 1 System Wiring Diagram. Each location must be programmed separately. 8. At this point, double-check all wiring for shorts and opens. 9. Connect door strike transformer to terminals T3 and T4. The maximum door strike load that may switch through the controller is 28 volts at 3 amps. 10.Connect 16 VAC from system transformer to terminals T1 and T2 on the system controller terminal block. (This transformer must not be used to power any other devices, such as the door strike.) The display will illuminate and the message WELCOME DIAL CODE NUMBER will appear. 11.Connect terminals R and T from the lobby unit to terminals R and T on the electrical room equipment (polarity is not important). Electrical Room Equipment Installation 1. Mount the PM900 Control Unit and the IH996 Relay Cabinet near the RJ71/CA71 phone blocks. 2. Wire connections between the cabinets can be eliminated by mounting the cabinets next to each other and using the supplied 10-conductor cable to interconnect the main controller to the relay cabinets. 3. Connect one end of the cable to JP1 on the PM900 (red wire to right side) and the other end to J9 on the IH996 (red wire to left side). 4. If additional IH996 Relay Cabinets are used, connect a cable from J10 of the first relay cabinet to J9 of the next relay cabinet (red wire to left side on both). 5. Plug the RY912 relay boards into the proper locations. Set the relay cabinet select jumper, located in the top right corner of the relay cabinet, to the proper setting. (Example: On relay cabinet #1, set the jumper to location #1.) 6. Make the wiring connections as shown in Figure 1 System Wiring Diagram. Connect the system relays to the RJ71/CA71 phone blocks. NOTE: Power up the system last. 7. Test the control equipment separately before connecting it to the lobby equipment. To test communications with the tenant, connect a standard touchtone phone to the lobby or guard terminals. Dial the 4-digit dial code. The corresponding LED on the relay card will illuminate and communications will be established. System Programming and Settings All programming of the entry system is accomplished through the use of the system keypad and the display located on the control panel. Use the supplied Tek-ENTRY Directory Worksheets to generate a record of the building occupants, their suite numbers, telephone numbers, assigned dial codes, and keyless entry codes. These sheets will be required for programming, as well as when changes are to be made. Complete the Tek-ENTRY Programming Worksheet, and ensure that it, the Tek-ENTRY Directory Worksheets and the User Operating Instructions are given to building management when installation and programming are complete. Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved. IL574 Tek-ENTRY No-Phone-Line Version Manual 5

Figure 2 Hands-Free Panel Wiring Diagram Figure 3 Handset Panel Wiring Diagram HANDSET PANEL MIC SP - + - + M S KEYPAD PCB POTENTIOMETER CONNECTOR RED BLACK } NOT CONNECTED BROWN RED ORANGE YELLOW GREEN BLUE RED BLACK } NOT CONNECTED BLACK RED WHITE WHITE (Rear View) MIC - + - SP + M S 6 IL574 Tek-ENTRY No-Phone-Line Version Manual Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

System Installation and Programming Program Mode Begin/End Enter * and the three-digit master code (default is *123) to begin a programming session. Use the 1 key on the keypad to scroll up the programming menu and the 3 key to scroll down. When the desired function is displayed on the screen, press the # key to select it. Follow the displayed instructions to make the necessary changes. When programming is complete, end program mode by pressing the * key twice. To Program Codes (Tenant Dial Codes) Manual Method Tenant dial codes are used at the entrance panel to call a tenant, and are usually listed on a tenants directory. Suite numbers may be used as tenant dial codes, if desired. To manually program the tenant dial codes that correspond to the tenant line relays: 1. When the programming menu displays VIEW/ENTER CODES, press the # key. The message RELAY TO REVIEW will appear. 2. Enter 0000 to begin with the first relay. The message RELAY 0000 will appear, along with its corresponding tenant dial code. 3. To view all keyless entry codes, use the 1 key to scroll up, and the 3 key to scroll down. 4. To program the displayed relay, press the # key and then the new 4-digit tenant dial code. Press the # key to save. Continue in this fashion until tenant dial codes have been entered for all relays. If a tenant dial code is fewer than 4 digits in length, enter zeros as leading digits. The leading zeros are not needed during actual use, but are required during programming. If an error is made when entering a tenant dial code, press the * key to backspace. 5. Press the * key to return to the programming menu. 6. If desired, press the * key to end program mode. To Program Codes (Tenant Dial Codes) Automatic Method Tenant dial codes are used at the entrance panel to call a tenant, and are usually listed on a tenants directory. Automatic programming assigns tenant dial code 0000 to relay #0, tenant dial code 0001 to relay #1, etc. To automatically program the tenant dial codes to correspond to the tenant line relays: 1. When the programming menu displays AUTO PROGRAM, PRESS #, press the # key. The message ARE YOU SURE? will appear. 2. Press the # key. The message PROGRAMMING PLEASE WAIT will appear. The system automatically programs tenant dial codes in sequence from 0000 to 0999 (a total of 1000 codes). Automatic programming takes approximately 20 seconds. 3. Press the * key to return to the programming menu. 4. If desired, press the * key to end program mode. Program Keyless Entry Codes Keyless entry codes allow tenants to enter through the controlled doors using a four-digit code from the system keypad, rather than a key. During actual use, this code must be preceded by the # key so that the code is not visible on the display. For security, assign each tenant a unique keyless entry code, and do not duplicate any suite numbers or tenant dial codes. 1. When the programming menu displays PROGRAM KEYLESS CODES, press the # key. The message KEYLESS ENTRY CODE # will appear. 2. Enter a four-digit code and press the # key to save. Continue entering keyless entry codes until all are entered. 3. Press the * key to return to the programming menu. 4. If desired, press the * key to end program mode. Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved. IL574 Tek-ENTRY No-Phone-Line Version Manual 7

System Installation and Programming View Keyless Entry Codes This section allows the review and/or deletion of keyless entry codes. 1. When the programming menu displays VIEW KEYLESS CODES, press the # key. The message CODE TO REVIEW will appear. 2. Enter the four-digit keyless entry code to be reviewed. The keyless entry code will be displayed. 3. To delete the displayed keyless entry code, press the # key. 4. To view all keyless entry codes, use the 1 key to scroll up, and the 3 key to scroll down. 5. Press the * key to return to the programming menu. 6. If desired, press the * key to end program mode. New Master Code The master code is used to access the program mode. When the entry system is shipped from the factory, its master code is set to *123. It is advisable to change the master code and record the new code in the appropriate place on the Tek-ENTRY Programming Worksheet. The master code is used by the installation company or by authorized personnel, only when programming is necessary. To change the master code: 1. When the programming menu displays NEW MASTER CODE, press the # key. The message MASTER CODE *123 will appear. 2. Enter a new three-digit master code and press the # key to save. 3. Press the * key to return to the programming menu. 4. If desired, press the * key to end program mode. Door Open Time The door open time can be reprogrammed to 0-99 seconds to prevent tailgating. Factory default is 10 seconds. See Door Timer Cut-Off in the System Introduction Special Features section for more information. 1. When the programming menu displays DOOR TIME, press the # key. The message DOOR OPEN TIME will appear. 2. Enter a two-digit time in seconds and press the # key to save. 3. Press the * key to return to the programming menu. 4. If desired, press the * key to end program mode. Talk Time Talk time can be reprogrammed to 0-99 seconds to set the maximum conversation length between a visitor and tenant. (Note: Talk time starts when visitor dials tenant.) Factory default is 60 seconds. 1. When the programming menu displays TALK TIME, press the # key. The message ON LINE TIME will appear. 2. Enter a two-digit time in seconds and press the # key to save. 3. Press the * key to return to the programming menu. 4. If desired, press the * key to end program mode. Pulse or Tone Dialing This section determines whether pulse or tone (DTMF) dialing is used to call off-premises telephones. Factory default is tone dialing. If the outside telephone line is pulse (rotary), change this setting: 1. When the programming menu displays PULSE OR TONE, press the # key. 2. Enter 00 for pulse (rotary) dialing; or enter 11 for tone (DTMF) dialing. Press the # key to save. 3. Press the * key to return to the programming menu. 4. If desired, press the * key to end program mode. 8 IL574 Tek-ENTRY No-Phone-Line Version Manual Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

System Installation and Programming Off-Premises Dialing Up to five off-premises telephone numbers can be assigned dial codes, if a telephone line is connected to the PM900 Control Unit. The telephone numbers are programmed in 11- digit format enter asterisks * for unused leading digits, as follows: * (***) 555-5555 for 7-digit local calls * (555) 555-5555 for 10-digit local calls 1 (555) 555-5555 for local or long distance calls 1. When the programming menu displays OUTSIDE PHONE #1 (#2, #3, #4 or #5) press the # key. 2. Enter a 4-digit dial code, and then the off-premises telephone number. Press the # key to save. NOTE: Off-premises dial codes cannot duplicate tenant dial codes. 3. Press the * key to return to the programming menu. 4. If desired, press the * key to end program mode. Erase/Reset to Factory Default This function erases all programming, including Tenant Dial Codes and Keyless Entry Codes, and returns the system to factory defaults. 1. When the programming menu displays ERASE/RESET TO FACTORY DEFAULT, press the # key. The message ARE YOU SURE? *=NO #=YES will appear. 2. Enter * to retain system programming; or enter # to erase all programming and return to factory defaults. 3. Press the * key to return to the programming menu. 4. If desired, press the * key to end program mode. Adjustments Volume Control The communication volume levels are factory preset for normal operations. The levels can be increased or decreased by adjusting the potentiometers located along the bottom of the system controller, behind the front display plate. Audio level from the entry system to the suite is controlled by the MICROPHONE VOLUME control. Audio level from the suite to the entry system is controlled by the SPEAKER VOLUME control. Rotary Phone Pulse Sensitivity Telephone companies do not specify or guarantee the waveshape of the signal transmitted when the tenant dials the digit 9 from a rotary (pulse) telephone. In order to achieve best results, Tek-ENTRY Telephone Entry Systems are furnished with a sensitivity adjustment potentiometer, as well as an indicator lamp to view the incoming rotary signal (pulses). This potentiometer is labeled PULSE SENSITIVITY on the system controller. The pulse sensitivity is factory preset so that a wide range of incoming rotary signals will properly trigger the door circuit, and so will usually not require adjustment. If adjustment is necessary because the door strike cannot be properly triggered, use this procedure. 1. Set the PULSE SENSITIVITY control to the middle position. 2. From the entry system, call the suite telephone that is not triggering the door circuit. 3. Observe the PULSE INDICATOR while the digit 9 is being dialed from the suite telephone. The indicator should flash distinctly every time a pulse is heard. 4. If the indicator barely comes on, the sensitivity is set too low. Increase the sensitivity by turning the shaft of the potentiometer clockwise 1/8th of a turn at a time until the indicator shows distinct flashing. 5. If the indicator is on steadily, the sensitivity is set too high and the door circuit may false trigger. Turn the shaft of the potentiometer counter-clockwise to decrease the sensitivity. The sensitivity may also require reduction if the phone line is particularly loud or noisy. NOTE: Sensitivity adjustments are not required when using DTMF (touchtone) suite telephones. Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved. IL574 Tek-ENTRY No-Phone-Line Version Manual 9

System Installation and Programming Notice to U.S. Installers and Users Incidence of Harm Should terminal equipment or protective circuitry cause harm to the telephone network, the telephone company shall, where practical, notify the customer that temporary discontinuance of service may be required; however, where prior notices are not practical, the telephone company may temporarily discontinue service if such action is deemed reasonable in the circumstances. In the case of such temporary discontinuance, the telephone company shall promptly notify the customer, who will be given the right to bring a complaint to the FCC if he feels the disconnection is not warranted. Changes in the Telephone Company Equipment or Facilities The telephone company may make changes in its communications facilities, equipment, operations or procedures, where such action is reasonably required and proper in its business. Should any such changes render the customer s terminal equipment incompatible with the telephone company facilities, the customer shall be given adequate notice to make modifications to maintain uninterrupted service. General The FCC prohibits customer-provided terminal equipment to be connected to party lines or to be used in conjunction with coin telephone service. The Tek-ENTRY Telephone Entry System is equipped with a USOC RJ11C standard miniature modular jack that is designed to plug directly into a modular jack. Notification to the Telephone Company Notification to the telephone company is no longer required prior to connecting the registered equipment; but upon request from the telephone company, the user shall tell the telephone company which line the equipment is connected to, as well as the registration number and ringer equivalence of the registered protective circuitry. In most, but not all areas, the sum of all REN s should be 5.0 or less. Malfunction of the Equipment In the event that the Tek-ENTRY Telephone Entry System should fail to operate properly, the customer shall disconnect the equipment from the telephone line to determine if it is the customer s equipment that is not working properly. If the problem is with the system equipment, the user shall discontinue use until it is repaired. In the event service is needed, the user should contact the local TekTone representative. Telephone Connections Requirement Except for telephone company provided ringers, all connections to the telephone network shall be made through standard plugs and standard telephone company provided jacks, or equivalent, in such manner as to allow for easy and immediate disconnection of the terminal equipment. Standard jacks shall be arranged so that if the plug connected thereto is withdrawn, no interference to the operation of the equipment at the customer s premises which remains connected to the telephone network shall occur by reason of such removal. FCC Notice This equipment generates and uses radio frequency energy and if not installed and used in strict accordance with the instructions listed in this Operation, Installation and Service Manual, interference to radio and television reception may occur. It has been tested and found to comply with the limits for a Class B Computing Device, in accordance with the specifications in Subpart B of Part 15 of the FCC rules. These rules are designed to provide reasonable protection against such interference in a residential installation. If this equipment does cause interference to radio or television reception 10 IL574 Tek-ENTRY No-Phone-Line Version Manual Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

System Installation and Programming which can be determined by turning off the equipment to see if the interference stops the user is encouraged to try and correct the interference by one or more of the following measures: 1. Reorient the receiving antenna. 2. Relocate the Tek-ENTRY Telephone Entry System with respect to the radio or television. 3. Plug the Tek-ENTRY Telephone Entry System into a different outlet, so that the system and the radio or television are on different circuits. NOTE: The manufacturer is not responsible for any radio or television interference caused by unauthorized modifications to this equipment. Such modifications could void the user s authority to operate the equipment. Notice to Canadian Installers and Users Notice The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user s satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized facility designated by the supplier. Any repairs or alterations made by the user of this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. In the event service is needed, the user should contact: TekTone Sound & Signal Mfg., Inc. 5014 New Street, Suite 434 Burlington, ON, L7L 6E8 Canada (905) 333-0051 Caution Users should ensure, for their own protection, that the electrical ground connections of the power utility, telephone lines, and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Users should not attempt to make such connections themselves, but should contact an appropriate electric inspection authority or electrician. Load Number The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop, which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices, subject only to the requirements that the sum of the Load Numbers of all of the devices does not exceed 100. Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved. IL574 Tek-ENTRY No-Phone-Line Version Manual 11

Figure 4 PM900 Control Unit Mounting Template Drill Here Drill Here THIS EDGE TO SIDE OF HOUSING THIS EDGE TO SIDE OF HOUSING THIS EDGE TO SIDE OF HOUSING 12 IL574 Tek-ENTRY No-Phone-Line Version Manual Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Figure 5 Frame and Housing Installation OH192 Housing OF192 Frame Frame TE905ANP Bracket Vandal Resistant Screws AM190D Directory TE Series Master Housing & Frame Chart FRAMES FLUSH MOUNT HOUSING Wall Width Wall Height Wall Model# Width Cut-out Model # Overall Cut-out Overall Cut-out Depth OF191 6-1/4" - OH191 4-3/8" 4-1/2" 17-1/8" 17-1/4" 3-1/2" OF192 10 1/4" - OH192 8-3/8" 8-1/2" 17-1/8" 17-1/4" 3-1/2" OF193 14-1/4" - OH193 12-3/8" 12-1/2" 17-1/8" 17-1/4" 3-1/2" OF194 18-1/4" - OH194 16-3/8" 16-1/2" 17-1/8" 17-1/4" 3-1/2" OF195 22-1/4" - OH195 20-3/8" 20-1/2" 17-1/8" 17-1/4" 3-1/2" OF196 26-1/4" - OH196 24-3/8" 24-1/2" 17-1/8" 17-1/4" 3-1/2" For more than 240 suites, contact factory for frame and housing information. Directories supplied separately. Notes: 1. Refer to frame and housing chart for wall cut-out dimensions. 2. AM190D directory panels have 60 name capacity. For additional directories, size the frame and housing accordingly. (Example: 1-TE905ANP + 2-AM190D requires an OF/OH193; 1-TE905ANP+3- AM190D requires an OF/OH194; 1-TE905ANP+0-AM190D requires an OF/OH191.) 3. Flush mounting frame shown in diagram above. 4. Frame bracket supplied with OF192. Bracket is supplied with scrulox screws, but it is suggested you use the spanner type vandal-resistant screws supplied with the TE905ANP. Use TekTone driver #HT007. 5. Refer to Figure 4 PM900 Control Unit Mounting Template to mount the PM900 Control Unit inside the housing. Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved. IL574 Tek-ENTRY No-Phone-Line Version Manual 13

Figure 6 Amphenol PIN Assignment, Bell Side (RJ71C, CA79X, CA71A) RES. PIN# C.O. LINE# 1 3 5 7 9 11 13 15 17 19 21 23 26 28 30 32 34 36 38 40 42 44 46 48 2 4 6 8 10 12 14 16 18 20 22 24 27 29 31 33 35 37 39 41 43 45 47 49 1 2 3 4 5 6 7 8 9 10 11 12 25 50 NOT USED 14 IL574 Tek-ENTRY No-Phone-Line Version Manual Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Tek-ENTRY Programming Worksheet Building Address: Date of Installation: Installation Company: Programming Instructions: A. Enter * and the three-digit Master Code (see #3 below) on the keypad to access the programming menu. B. Press the 1 key to scroll up, or press the 3 key to scroll down the menu screen to the desired function. C. Press the # key to select the desired function when it is displayed on the screen. D. Follow the displayed instructions to make the necessary changes. E. Press the * key twice to end program mode. Factory Default Programming: Function Factory Default Programmed 1. Tenant Dial Codes Blank (4 digits) See Directory Worksheet 2. Keyless Entry Codes Blank (4 digits) See Directory Worksheet 3. Master Code * 1 2 3 * 4. Door Open Time 10 Seconds (0-99 sec) 5. Talk Time 60 Seconds (0 99 sec) 6. Night Service On/Off * 4 5 6 Fixed Off-Premises Dialing Dial Code Telephone Number Name 1. ( ) 2. ( ) 3. ( ) 4. ( ) 5. ( ) Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved. IL574 Tek-ENTRY No-Phone-Line Version Manual 15

Tek-ENTRY Directory Worksheet Suite # Tenant Name Tenant Dial Code Keyless Entry Code 16 IL574 Tek-ENTRY No-Phone-Line Version Manual Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Tek-ENTRY Directory Worksheet Suite # Tenant Name Tenant Dial Code Keyless Entry Code Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved. IL574 Tek-ENTRY No-Phone-Line Version Manual 17

Tek-ENTRY Directory Worksheet Suite # Tenant Name Tenant Dial Code Keyless Entry Code

Tek-ENTRY Telephone Entry System Operating Instructions A TekTone Tek-ENTRY Telephone Entry System has been installed in your building to provide increased security for yourself and your family. The system provides communication and entry control using your telephone. Your visitor will find your name and assigned dial code number on the directory near the Tek- ENTRY System. When the visitor enters your dial code number, the Tek-ENTRY System will automatically ring your suite. You can answer from any telephone. Answer the call and establish the identity of your visitor. The call will automatically cut off after a preprogrammed time period. You will hear a tone 10 seconds before the call is disconnected. If you want to allow your visitor to enter, simply dial or press 9 on your telephone. This will unlock the entrance to your building or complex. You will hear a tone indicating the lock has been released. After hearing the tone, you may hang up. To deny entry, simply hang up. Do not dial 9. If you are on the phone when a visitor calls you from the Tek-ENTRY System, they will get a busy signal unless you have call waiting service assigned to your telephone. Optional Entry Code Use If the box below is filled in, you have been assigned your own entry code. Entering this code on the Tek-ENTRY System keypad will allow you to enter the building without a key. When using this code, it is not necessary to pick up the handset. Press the # key, and then the four-digit number. Your code will not appear on the display. # Sound & Signal Mfg., Inc.