GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

Similar documents
GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen

GAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain.

Carbon Dioxide Extinguishing Systems Fighting fire with CO2

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea

Oxeo extinguishing systems

Fire suppression systems for server rooms and data centres

CO2 COCO GAS FLOODING SYSTEM

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

FIRE SUPPRESSION SYSTEM

KD Innovative extinguishing with Novec TM 1230 by 3M TM

GAS EXTINGUISHING SYSTEMS COMPACT EXTINGUISHING SYSTEMS. OneU. Fire Protection Systems for 19" Racks

Safe, Effective, Environment-friendly

Welcome to Argonite fire protection from Ginge-Kerr

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

ODS & SGG Alternatives for the Fire Protection Industry 2018

How can you minimize consequential damages in case of a fire?

automatic FiReFighTing SYSTeMS in PainT booths

Superior by Design The Kidde ADS TM FM-200 System

An Overview of Extinguishing Systems for Computer Equipment

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

CO 2 EXTINGUISHING SYSTEMS

How can I protect invaluable assets and the environment from the effects of a fire?

MINIMAX FIRE PRODUCTS WHITE PAPER THE COST-BENEFIT ADVANTAGES OF REPLACING HALON WITH 725 PSI MX 1230 CLEAN AGENT FIRE SUPPRESSION SYSTEMS

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

BOC FS125 The Fire Extinguishing Solution

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

Inert Gas Fire Extinguishing System

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Element C3.4 Fire Fighting Equipment

CO 2 Fire Extinguishing Systems

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

Institute for Plasma Research Welcomes you all on

GX-20/FM-200 Fire Extinguishing System

5 Key Stages to Risk Assessment

Carbon Dioxide Fire Suppression Systems

Rick Seidel Fike Corporation Regional Sales Manager

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

What extinguishes fires without pressure peaks?

SAPPHIRE. Gaseous Fire Suppression Systems. Delivering 3M Novec 1230 Fire Protection Fluid

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

Hospitals and Major Medical Centers

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

CO 2. fire extinguishing systems

Sinorix Silent Extinguishing Technology protecting the quiet way

DuPont FE-25 FIRE EXTINGUISHANT. Preferred Replacement for Existing Systems and the Choice for New Applications

So what is a fire hazard?

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

FOREFRONT AT THE OF PROTECTION

Fire protection for buildings

Fire Extinguisher Training

What are the four things that must be present at the same time to produce fire?

Fire Protection in the Mining Industry. Garry Kwok Board Member

EXTINGUISHES FIRES QUICKLY AND EFFECTIVELY. FirExting Gas extinguishing systems with non-liquefied and natural inert gases. Nitrogen Argon IG-541

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

What is HI-FOG? The natural enemy of fire

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Technologies Fire Prevention Systems. Oxeo Prevent Oxygen Reduction System Active Fire Prevention using natural Nitrogen

GENERAL SPECIFICATION SAFETY

Identify RISKS. Design SOLUTIONS. Prevent DISASTERS

Certificate of Conformity Certificate num. Registration date Version Valid until

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

Mitigating Fire Risks in Mission Critical Facilities

CONTENTS. bawa-speci, Ver Maintenance. 1. INTRODUCTION: 1.1 bawa-speci Version 01

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

Creating a safer world!

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

Risk Management Department. Fire Extinguishers

CLEAN AGENTS Updates to the NFPA 2001 Standard on Clean Agent Fire Extinguishing Systems 2015 Edition

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

Fire Extinguisher Training

XC10 combined fire detection and extinguishing control

MB05. RESPOND TO EMERGENCIES BASIC KNOWLEDGE OF EMERGENCY PROCEDURES, INCLUDING EMERGENCY SHUTDOWN

ENERGY EFFICIENCY PERFORMANCE SAVINGS SERVICE MANUAL R-290

FIRE SAFETY PRACTICES AND PROCEDURES

AUTOMATIC FIRE SUPPRESSION SYSTEMS

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

FIRE PROTECTION TECHNOLOGY Solutions never thought of before

Fireward Fixed Fire Fighting System. For Open Areas & Enclosed Risks fireward.co.uk

Fixed Fire Suppression. Protec. Protec Fire Detection plc. Fixed Fire Suppression Solutions ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE

FIRE AND FIRE FITTING By Mr. Prashant Sansare

STAT X - SPECIAL HAZARD FIRE PROTECTION

3M Novec Fire Protection Fluid

...extinguish it with a water spray.

IT AFEM. Table of Contents. Error! Table not allowed in footnote, endnote, header, footer, comment, or text box.

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0)

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI

CLEAN AGENT SYSTEMS. TABLE 1 Agents Recognized in NFPA 2001

STANDARDS FOR ACTIVE FIRE PROTECTION. Stewart Kidd Loss Prevention Consultancy Ltd

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Committee Input No. 9-NFPA [ Global Input ] Supplemental Information. Submitter Information Verification. Committee Statement

CARBON DIOXIDE CO 2 Industrial fire suppression systems

7 Fire Protection Systems Synopsis

MISSION CRITICAL FIRE PROTECTION

Nessie High Pressure Water Mist Components for Fire Fighting

Fire Protection of Hotels. With SEM-SAFE High-Pressure Water Mist System

Transcription:

GAS EXTINGUISHING SYSTEMS Argon Extinguishing Systems Fire Protection Systems

EFFECTIVE NATURAL no damage to the atmosphere technology for complex applications EXAMPLE GAS EXTINGUISHING SYSTEMS solution Computing Center with Separate Data Storage The Extinguishing Gases Functions under Extreme Conditions Upon fire detection the extinguishing process is initiated. Argon extinguishes a fire by displacing oxygen. When oxygen levels fall below the limit required for combustion, the fire is extinguished. Takes into account chemical and physical processes as well as environmental conditions during extinguishing. These could include (not limited to): Argon is found naturally in the air and thus does not have an adverse effect on the atmosphere. No other extinguishing gas has such an excellent environmental track record. Argon is non-toxic and electrically non-conductive. Areas with flammable liquids our Areas used for the production and processing of paints An audible alarm is activated prior to discharge. Once the prealarm period has passed, the extinguishing begins. The inert gas is fed into the discharge area by a system of pipes. Finally, the gas is released through nozzles, lowering the oxygen level to a percentage that will not support combustion. Fire extinguishing systems with argon as the agent are particularly suitable for a number of specific risk areas. In the event of a fire, they need to ensure the following: Maintains Availability One of the top priorities of these systems is to minimize downtime and maintain functionality of whatever is being protected. This would include (not limited to): IT installations and systems Control rooms for telecommunication systems Data archives Switch and control centers Medical facilities Control rooms and varnishes Areas for warehousing hazardous goods Varnishing and powder coating cubicles Magnesium, lithium, - processing Useful in Highly Specialized Areas Effective extinguishing of shielded objects or difficult-to-reach areas such as: Toolmaking machines Hydraulic facilities Silos and dust filters Printing machines Turbines Transformers Textile machines Engine test beds Engine rooms on ships. The amount of required agent is determined on a per job basis with a few key factors. These include, the volume of the enclosed area, its surface and quality (gas-tightness) and the combustible material that is being protected. The job also determines the size of the pipe system and the positioning of the spray nozzles. When protecting an enclosed area, nozzles are spread evenly over the entire area. In enclosed areas with high ceilings, the system can consist of multiple levels. In some cases, several areas are connected to one extinguishing system. In these instances, extinguishing gas is controlled and released through selector valves. The inert gas is stored in high-pressure cylinders which are installed and stored in compact and expandable racks. The weight of each cylinder is monitored and displayed in a central storage area, ensuring permanent control of the extinguishing volume. Flooding zone 2 (room protection data archive) Flooding zone 1 (room protection computer room) Fire detection and control panel Safety valve Pneumatic door release unit Cylinder bank Pneumatic horn Release and time delay device Room protection nozzle Electric horn Selector valve Fire detection element Changeover valve Disable device Pneumatic release device Pressure reducer Pressure relief flap

EFFECTIVE NATURAL no damage to the atmosphere technology for complex applications EXAMPLE GAS EXTINGUISHING SYSTEMS solution Computing Center with Separate Data Storage The Extinguishing Gases Functions under Extreme Conditions Upon fire detection the extinguishing process is initiated. Argon extinguishes a fire by displacing oxygen. When oxygen levels fall below the limit required for combustion, the fire is extinguished. Takes into account chemical and physical processes as well as environmental conditions during extinguishing. These could include (not limited to): Argon is found naturally in the air and thus does not have an adverse effect on the atmosphere. No other extinguishing gas has such an excellent environmental track record. Argon is non-toxic and electrically non-conductive. Areas with flammable liquids our Areas used for the production and processing of paints An audible alarm is activated prior to discharge. Once the prealarm period has passed, the extinguishing begins. The inert gas is fed into the discharge area by a system of pipes. Finally, the gas is released through nozzles, lowering the oxygen level to a percentage that will not support combustion. Fire extinguishing systems with argon as the agent are particularly suitable for a number of specific risk areas. In the event of a fire, they need to ensure the following: Maintains Availability One of the top priorities of these systems is to minimize downtime and maintain functionality of whatever is being protected. This would include (not limited to): IT installations and systems Control rooms for telecommunication systems Data archives Switch and control centers Medical facilities Control rooms and varnishes Areas for warehousing hazardous goods Varnishing and powder coating cubicles Magnesium, lithium, - processing Useful in Highly Specialized Areas Effective extinguishing of shielded objects or difficult-to-reach areas such as: Toolmaking machines Hydraulic facilities Silos and dust filters Printing machines Turbines Transformers Textile machines Engine test beds Engine rooms on ships. The amount of required agent is determined on a per job basis with a few key factors. These include, the volume of the enclosed area, its surface and quality (gas-tightness) and the combustible material that is being protected. The job also determines the size of the pipe system and the positioning of the spray nozzles. When protecting an enclosed area, nozzles are spread evenly over the entire area. In enclosed areas with high ceilings, the system can consist of multiple levels. In some cases, several areas are connected to one extinguishing system. In these instances, extinguishing gas is controlled and released through selector valves. The inert gas is stored in high-pressure cylinders which are installed and stored in compact and expandable racks. The weight of each cylinder is monitored and displayed in a central storage area, ensuring permanent control of the extinguishing volume. Flooding zone 2 (room protection data archive) Flooding zone 1 (room protection computer room) Fire detection and control panel Safety valve Pneumatic door release unit Cylinder bank Pneumatic horn Release and time delay device Room protection nozzle Electric horn Selector valve Fire detection element Changeover valve Disable device Pneumatic release device Pressure reducer Pressure relief flap

EFFECTIVE NATURAL no damage to the atmosphere technology for complex applications EXAMPLE GAS EXTINGUISHING SYSTEMS solution Computing Center with Separate Data Storage The Extinguishing Gases Functions under Extreme Conditions Upon fire detection the extinguishing process is initiated. Argon extinguishes a fire by displacing oxygen. When oxygen levels fall below the limit required for combustion, the fire is extinguished. Takes into account chemical and physical processes as well as environmental conditions during extinguishing. These could include (not limited to): Argon is found naturally in the air and thus does not have an adverse effect on the atmosphere. No other extinguishing gas has such an excellent environmental track record. Argon is non-toxic and electrically non-conductive. Areas with flammable liquids our Areas used for the production and processing of paints An audible alarm is activated prior to discharge. Once the prealarm period has passed, the extinguishing begins. The inert gas is fed into the discharge area by a system of pipes. Finally, the gas is released through nozzles, lowering the oxygen level to a percentage that will not support combustion. Fire extinguishing systems with argon as the agent are particularly suitable for a number of specific risk areas. In the event of a fire, they need to ensure the following: Maintains Availability One of the top priorities of these systems is to minimize downtime and maintain functionality of whatever is being protected. This would include (not limited to): IT installations and systems Control rooms for telecommunication systems Data archives Switch and control centers Medical facilities Control rooms and varnishes Areas for warehousing hazardous goods Varnishing and powder coating cubicles Magnesium, lithium, - processing Useful in Highly Specialized Areas Effective extinguishing of shielded objects or difficult-to-reach areas such as: Toolmaking machines Hydraulic facilities Silos and dust filters Printing machines Turbines Transformers Textile machines Engine test beds Engine rooms on ships. The amount of required agent is determined on a per job basis with a few key factors. These include, the volume of the enclosed area, its surface and quality (gas-tightness) and the combustible material that is being protected. The job also determines the size of the pipe system and the positioning of the spray nozzles. When protecting an enclosed area, nozzles are spread evenly over the entire area. In enclosed areas with high ceilings, the system can consist of multiple levels. In some cases, several areas are connected to one extinguishing system. In these instances, extinguishing gas is controlled and released through selector valves. The inert gas is stored in high-pressure cylinders which are installed and stored in compact and expandable racks. The weight of each cylinder is monitored and displayed in a central storage area, ensuring permanent control of the extinguishing volume. Flooding zone 2 (room protection data archive) Flooding zone 1 (room protection computer room) Fire detection and control panel Safety valve Pneumatic door release unit Cylinder bank Pneumatic horn Release and time delay device Room protection nozzle Electric horn Selector valve Fire detection element Changeover valve Disable device Pneumatic release device Pressure reducer Pressure relief flap

FUNCTION Single Stable Molecule Effective on Many Class D Metals Argon systems are exactly that, the single molecule Ar gas. No complicated blends to deal with, as a single molecule gas Argon has been found to be effective on many Class D hazards. The single molecule structure is more stable in higher heat applications that are common in metal fires such as magnesium and lithium. At higher concentrations it may be a viable alternative to the standard Class D dry powders. With proper design, application and detection Argon systems can be effective on many of the hard to protect hazards. Minimal Downtime After a Fire You can only truly appreciate the value of this system in the aftermath of a fire. Because, the majority of the time there is no aftermath if you are protected with the Minimax Argon System. You simply return to your station and resume work. There is nothing to clean-up from the agent discharge and, there may not even be anything to repair or replace. When you can t afford even 60 seconds of down time, the Minimax Argon Fire Suppression System is there to keep you running. What value would you put on that kind of protection?

ADVANTAGES Argon Fire Suppression System - Advantages Suppresses fires leaving no residue. Suitable for enclosed and occupied areas. Completely inert eliminating toxic breakdown products due to agent. Optimum efficacy as a result of homoge neous distribution of the agent and rapid concentration build-up. During discharge, there is no condensation thus maintaining a safe environment with good visibility. Activation and extinguishing is possible without interrupting operations. Temperature variance is minimal, leaving no concern of thermal shock. The Argon System with its modular and multi-purpose architecture can be re-engin eered or extended to suit any operation. Recharging the system is quick and cost effective as argon is readily available. Approved and certified by every major authority and designed to international standards. Readily accepted by the Authority Having Jurisdiction (AHJ). Zero Ozone Depletion Potential (ODP) and Zero Global Warming Potential (GWP). Zero restriction by the EPA and no chance of a future ban as it is a natural part of the ambient air we breath. Effectively extinguishes at low ambient temperatures. Minimax USA Inc. 4030 E Quenton Drive Suite 112 Mesa, AZ 85215 Phone 888.882.0191 Fax 480.718.8555 sales@minimaxfp.com www.minimaxfp.com Argon_01 3/11/2009 Minimax USA Inc. reserves the right to make any necessary changes

http://10.1.0.13/node/66/edit[10/27/2011 3:53:03 PM]