Product Data Sheet Adsorption Dryer DPS (A)

Similar documents
Product Data Sheet Adsorption Dryer DPS

Product Data Sheet Refrigeration Dryer DFX

Product Data Sheet Adsorption Dryer DTS..V

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W)

Product Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management

DESICCANT AIR DRYERS. BD + CD + CD series

DESICCANT AIR DRYERS. BD + CD + CD series

High Efficiency Compressed Air Dryers. Adsorption Dryers Classical System INTELLIGENT AIR TECHNOLOGY

Filters & Centrifugal Separators

High Efficiency Compressed Air Dryers. Adsorption Dryers Classical System INTELLIGENT AIR TECHNOLOGY

ADSORPTION DRYING: WHY?

Operating Manual Adsorption Dryer DPS Version: 11/2010/DE

Adsorption Air Dryers

Dryer Systems Heatless Regenerating Adsorption Dryers

Concept WVM Brief description. Efficient compressed-air adsorption dryer with vacuum regeneration. NEW! Now with improved ZDMC2

Dry compressed air finally exits via a validated GL after-filter preventing the migration of particles into the downstream compressed air network.

Dryer Systems Heatless Regenerating Adsorption Dryers

Dryer Systems Heatless Regenerating Adsorption Dryers

Heatless Regenerative Compressed Air Dryers. Compressed Air System Products. Made in America

Membrane Dryers KMM Series

Compressed air treatment for applications up to 2,500 m³/h and 16 bar

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY

Dryer Systems Heatless Regenerating Purification Packages

A-DRY Heatless adsorption compressed air dryers

Heat Les Desiccant Compressed Air Dryers. DSE Series DSS Series DHD Series

Product Catalogue Edition 1

Adsorption dryers PDAD

Refrigeration Dryers TG TI Series

HEATLESS REGENERATED ADSORPTION DRYER ULTRAPAC SMART

Adsorption dryer SDAT

Membrane Dryers KMM Series

ULTRAPAC SMART ULTRAPAC SMART INDUSTRIES

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY

Dryer Systems. Breathing Air Units

High Pressure Dryer HLP-MSD 0055 to 0870, PN 100 to PN 400

Adsorption Compressed Air Dryer Heatless or heater regeneration

Industrial Oxygen Generation Plant

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series

Desiccant Dryers. Desiccant Dryers. Heatless Heated Purge Blower Purge Modular

Air. Pressure. Motion. nnnnnnnn

Adsorption Dryers for Compressed Air

Compressed air preparation Compressed air storage Moisture management. Catalog #1

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

pneudri modular dessicant dryer

High Pressure Adsorption Dryer HLP PN 25, 0040 to 0125 HLP PN 40, 0050 to 0155

Adsorption Dryers. AD 7 to 1300

ARV -3 & ARV -10 Active Reservoir Vent Installation and Operation Manual

Membrane Dryer. Air inflow rate KMM Series to m 3 /min

TECHNICAL BID EVALUATION SCOPE OF WORK COMPRESSED AIR SYSTEM

Adsorptions dryers. ecodry K-MT multitronic

Ingersoll Rand. Heatless and Heated Blower Desiccant Air Dryers ,900 m 3 /hr

HEATLESS DESICCANT AIR DRYERS

Condensate Drain Valves

Heatless Desiccant Compressed Air Dryers

Dual Tower Heat Reactivated Desiccant Air Dryer

Adsorption air dryers ADS 1 215

DGH Series Global Air Treatment

COMPRESSED AIR TREATMENT

Instruction Manual Dry spell HFH INSTALLATION, OPERATION, MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

V A C U U M A N D P R E S S U R E T E C H N O L O G Y

DESICCANT AIR DRYERS FOR SUPERIOR PRODUCTIVITY

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm

Technical Specification

Dryer Systems Heat Regenerating Adsorption Dryers

Dryer Systems Heat Regenerating Adsorption Dryers

Desiccant Dryers DC Series (Heatless regenerated) Air flow rates 0.15 to m³/min.

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery 0.26 to 0.80 m 3 /min, Pressures bar

MANUAL. Dryspell INSTALLATION OPERATION MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

ecodry K-MT multitronic

PNEUDRI High Efficiency Compressed Air Dryers.

Adsorption Air Dryers

Combination Dryer HYBRITEC

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

CDT Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Heatless Desiccant Air Dryers 40 5,400 SCfm

Adsorption Dryers. AD 7 to 1300

DP 300 mobile dew point instrument

Adsorption dryer PDAD. (en) Operating instructions g [ ]

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series

ADSORPTION DRYERS. For all applications which require perfectly dry compressed air : Advantages of "ALC" dryers :

Desiccant Dryers DC Series (Heatless regenerated) Air flow rates 0.15 to m³/min.

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

CDH Series Heatless Desiccant Dryers CFM

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency

Excellent performance with low operating costs, Energy saving and environmentally friendly

COMPRESSED AIR TREATMENT COMPRESSED AIR DRYER

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

productdatasheet Compressed Air Refrigeration Dryer Efficient compressed air treatment Rev 01_0317 Page 1

COMPRESSED AIR TREATMENT COMPRESSED AIR DRYER

SULLAIR DESICCANT DRYERS

The Clever Compressor. A tidy matter! Oil free piston compressors SOLIDdent

Regenerative Desiccant Dryers. KAD, KED, KBD and Hybritec Series

ingersoll rand desiccant dryers

Adsorption Dryers. DB 05 to 130

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

Modular Adsorption Dryers

Air treatment guide. Adsorption Dryers

Refrigeration Dryers TG TI Series

Transcription:

Version: 1.0.5 Author: Tassilo Tappe Date:13.07.2012 Field of application Adsorption dryers of the DPS series are designed for drying compressed air and nitrogen to pressure dew points of -25 C to -70 C (depending on the design) at operating pressures of 4 bar to 16 bar. On request design pressures up to 63 bar are possible. Function For drying the compressed air, i.e. "adsorption", the compressed air flow is led through a vessel filled with desiccant. The desiccant extracts moisture from the compressed air and stores it in its structure until the desiccant is saturated with moisture. The saturated desiccant then has to be regenerated, i.e. the moisture stored in the structure has to be "removed" before the desiccant can be used for drying again. Continuous operation of an adsorption dryer therefore requires two vessels that are operated alternately. One vessel is used for drying the compressed air (adsorption) and the other vessel for regenerating the desiccant. For the DPS series the change interval between adsorption and regeneration is 5 minutes at nominal conditions. For the DPS series a certain quantity of dried compressed air is drawn off at the dryer outlet (approx. 15% of the nominal volume flow rate at nominal conditions). This amount of compressed air is expanded to atmospheric pressure and is led through the vessel to regenerate the desiccant. The dried, decompressed air is extremely moisturesubsaturated and thus extracts the moisture stored in the desiccant and discharges it to the atmosphere via a silencer (heatless regeneration). Page 1 of 8

Features The desiccant has a high drying capacity for moisture and a long service life of several years. This ensures permanently low and stable pressure dew points. The valves and flow paths required for vessel chamber switch-over are completely installed in valve blocks. This integrated design eliminates the need for time-consuming piping installation and minimises the leak potential. Air flow cross-section sizes above average minimise the pressure loss. The solenoid valve combination consists of 4 pilot-controlled diaphragm valves. Thanks to the individual control option for each valve, overlapping switch-over and a defined flow path is ensured at any time. The nonreturn valve combination consisting of 2 non-return valves is also installed in a leak-free aluminium valve block. A silencer is used for effective reduction of the expansion noise. The valves of the DPS series are controlled by means of a type "C1" processor control system with a 2-line clear text display and 3 operating keys. The control system is installed in a plastic housing with IP65 protection. The clear text display is used for direct and easy-to-understand indication of the operating state, errors, runtimes, service messages etc. If a pressure dew point sensor (option H) is connected, the current pressure dew point of the compressed air is also directly shown on the display and provided as a 4-20 ma signal. The pressure dew point measurement (option H) allows for dew-point dependent operation of the dryer. Depending on the load of the dryer, the adsorption cycle may be extended, i.e. the switch-over frequency is adapted to the operating situation. This minimise the regeneration air consumption and thus the energy costs are minimised. In addition, the control system provides a compressor synchronising contact. It is used for synchronous operation of the dryer and a compressor which additionally reduces the regeneration air consumption. This function can also be used in conjunction with dew point-dependent operation. If a differential pressure monitoring system with alarm contact is fitted to the prefilter and afterfilter (option), the alarm contacts can be connected to the control system, displayed and processed. As standard, the dryer is provided with a prefilter (fine filter) which prevents solid and liquid contaminants from entering the dryer. This increases the service life of the dryer. An afterfilter (general purpose filter) is also provided as standard. It is used to prevent desiccant dust from entering the downstream system. The filters are directly flanged to the upper valve block. Therefore, piping material is not required. The dryers comply with the requirements of the Pressure Equipment Directive 97/23/EC, and have the CE marking of this European directive. Page 2 of 8

Basic data Model DPS 10 (A) DPS 15 (A) DPS 20 (A) DPS 25 (A) DPS 30 (A) DPS 40 (A) DPS 60 (A) DPS 80 (A) DPS 100 (A) Nominal volume flow (VN) *1 110 m³/h 150 m³/h 200 m³/h 260 m³/h 320 m³/h 410 m³/h 590 m³/h 770 m³/h 1,000 m³/h Min./Max. allowable operating pressure 4-16 bar (higher design pressures up to 63 bar on request ) *1 - referred to 1 bar(a) and 20 C at 7 bar operating pressure, inlet temperature 35 C and pressure dew point at outlet -40 C Min./Max. allowable operating temperature +2 C - +60 C Purity classes according to ISO 8573-1 Contamination DPS.. DPS..A Solid particles *2 (Class 2) Water content *2 Class 1-3 *3 Total oil content *2 Class 1 *4 Class 0-1 *2 - typical result, on the assumption that the suitable inlet concentrations and operating and marginal conditions are given *3 - depending on the design *4 - the oil vapour content is not taken into account, it may reduce the purity class Volume flow conversion factors «F1» - Pressure in bar (g) 4 *5 5 6 7 8 9 10 11 12 13 14 15 16 0.63 0.75 0.88 1.00 1.13 1.25 1.38 1.50 1.63 1.75 1.88 2.00 2.13 *5 - in the event of operating pressures below 5 bar, an external instrument air supply must be provided «F2» - Inlet temperature in C 25 30 35 40 45 50 55 60 1.00 1.00 1.00 0.97 0.87 0.80 0.64 0.51 Calculation of the converted volume flow Converted volume flow VK VK = VN x F1 x F2 Nominal required volume flow VN min VN min = VK / F1 / F2 VK : Converted volume flow calculated for the operating conditions VN min: Nominal required volume flow calculated for the operating conditions, based on the volume flow at operating conditions Page 3 of 8

Maintenance rules All Models Maintenance interval and maintenance activities Once a week : - Check differential pressure on the prefilter and afterfilter - Check function of the condensate drain on the prefilter Every 12 months : - Replace filter elements on prefilter and afterfilter - Check expansion silencer, clean or replace, if required - Replace activated carbon and oil indicator tube (type DPS..A) *7 - Calibrate dew point sensor (option H) (interchange principle possible) Every 24 months: - Replace non-return valves and solenoid valves Every 48 months: *6 *7 - Replace desiccant, sleeve cylinder and seals Every 5 /10 years (for DPS 40 DPS 100) - Pressure vessel inspection acc. to Ordinance on Industrial Safety and Health of September 27th, 2002 (BGBI. I p. 3777) 15, - Inside check every 5 years, carried out by an authorised inspection agency - Strength test (hydrostatic) every 10 years, carried out by an authorised inspection agency, see page 5 *6 The regular service life of the desiccant is 3-5 years, however, it is very much depending on the contamination level of the incoming compressed air and the operating temperature. In order to achieve the specified service life of the desiccant, it is vital to exchange the filter elements as described above. *7 The desiccant and the activated carbon must be disposed of according to the European waste code. A possible oil contamination must be taken into account. Product specific data Specification Pressure dew points Electrical connection Power consumption -25 C / -40 C / -70 C 230V 50/60 Hz, alternative 115V 50/60Hz or 24V DC < 50 Watt Protection Class IP 65 (Nema 4) Valve switching power (for each valve) Materials Component Vessel and supports 20 Watt Steel (P265GH, ST37.0, St35.8) Outside : sand blasted SA2,5 (ISO8501) ; 1-component primer on alkyd resin base ; dry thickness approx 40 µm Coating (e.g. DuPont PercoTop 021, or similar product) 2-component acrylic resin paint ; dry thickness approx 40 µm (e.g. DuPont PercoTop 9600, or similar product) Desiccant support screen Stainless steel 304 Pipe connections (fittings) Valve body Valve seats Sealing materials Steel, galvanized Aluminium Brass (Ms58), reinforced plastic HNBR Screws 5.6 steel, zinc-plated (on valve blocks 8.8 stainless 304) Desiccant filling Mounted prefilter and afterfilter 80% Molecular sieve 4A und 20% Silica gel See product data sheets for filter housing and filter elements Page 4 of 8

Connections, dimensions and weight (including prefilter and afterfilter) DPS Model Connection Height Width Depth Weight Prefilter type Afterfilter type DPS 10 G 1 1460 mm 675 mm 515 mm 126 kg FCA110XNDF FCA110ZNDM DPS 15 G 1 1700 mm 675 mm 515 mm 142 kg FCA110XNDF FCA110ZNDM DPS 20 G 1 1710 mm 675 mm 515 mm 180 kg FCA110XNDF FCA110ZNDM DPS 25 G 1 1735 mm 675 mm 515 mm 220 kg FCA110XNDF FCA110ZNDM DPS 30 G 1 1/2 1825 mm 745 mm 520 mm 255 kg FCA115XNDF FCA115ZNDM DPS 40 G 1 1/2 1840 mm 755 mm 525 mm 275 kg FCA120XNDF FCA120ZNDM DPS 60 G 1 1/2 1870 mm 775 mm 575 mm 355 kg FCA130XNDF FCA130ZNDM DPS 80 G 2 2045 mm 1050 mm 695 mm 470 kg FCA140XNDF FCA140ZNDM DPS 100 G 2 2060 mm 1050 mm 730 mm 560 kg FCA140XNDF FCA140ZNDM DPS..A Model Connection Height Width Depth Weight Prefilter type Afterfilter type DPS 10 A G 1 1460 mm 955 mm 515 mm 173 kg FCA110XNDF FCA110ZNDM DPS 15 A G 1 1700 mm 955 mm 515 mm 195 kg FCA110XNDF FCA110ZNDM DPS 20 A G 1 1710 mm 955 mm 515 mm 250 kg FCA110XNDF FCA110ZNDM DPS 25 A G 1 1735 mm 955 mm 515 mm 300 kg FCA110XNDF FCA110ZNDM DPS 30 A G 1 1/2 1825 mm 1130 mm 520 mm 350 kg FCA115XNDF FCA115ZNDM DPS 40 A G 1 1/2 1840 mm 1140 mm 525 mm 395 kg FCA120XNDF FCA120ZNDM DPS 60 A G 1 1/2 1870 mm 1200 mm 575 mm 525 kg FCA130XNDF FCA130ZNDM DPS 80 A G 2 2045 mm 1470 mm 695 mm 630 kg FCA140XNDF FCA140ZNDM DPS 100 A G 2 2060 mm 1520 mm 730 mm 740 kg FCA140XNDF FCA140ZNDM Classification according to Pressure Equipment Directive 97/23/EC for group 2 fluids Model Volume Category Marking Commissioning Routine inspection *8 inspection *8 DPS 10 (A) 21 litres II CE 0525 NB *9 --- DPS 15 (A) 26 litres II CE 0525 NB *9 --- DPS 20 (A) 34.5 litres II CE 0525 NB *9 --- DPS 25 (A) 44.5 litres II CE 0525 NB *9 --- DPS 30 (A) 55.6 litres II CE 0525 NB *9 --- DPS 40 (A) 71 litres III CE 0525 NB *9 NB *9 DPS 60 (A) 101 litres III CE 0525 NB *9 NB *9 DPS 80 (A) 132 litres III CE 0525 NB *9 NB *9 DPS 100 (A) 175 litres III CE 0525 NB *9 NB *9 *8 - In Germany defined by the Ordinance on Industrial Safety and Health of September 27th, 2002 (BGBI. I p. 3777) 14 and 15 *9 - Inspection by Authorised Person (AP) or Notified Body (NB) Page 5 of 8

Other Directives Model All Models EMC-Standard (inspection scope for control system, solenoid valves and dew point measurement): Emitted interference acc. : EN 55011:1998 + A1:1999 + A2:2002 (limit value class: B) EN 61000-3-2:2006-04, EN61000-3-3:2008 Interference resistance acc. : EN 61000-6-2:2005 Machinery Directive 2006/42/EC is not applicable. Flow diagram (PID) for DPS A F V HV RV SB ST X D O PI DPI MT GJ GO RO CO Dryer vessel Filter Valve Manual valve Non return valve Sleeve cylinder Support screen Silencer for expansion Condensate drain Orifice for regeneration air flow Pressure gauge Differential pressure gauge Pressure dew point transmitter Gas inlet Gas outlet Regeneration air outlet Condensate outlet Page 6 of 8

Flow diagram (PID) for DPS..A A F V HV RV SB ST X D O PI DPI QI PC MT GJ GO RO CO Dryer vessel Filter Valve Manual valve Non return valve Sleeve cylinder Support screen Silencer for expansion Condensate drain Orifice for regeneration air flow Pressure gauge Differential pressure gauge Oil-Indicator with throttle valve Pressure regulator 7bar[g] Pressure dew point transmitter Gas inlet Gas outlet Regeneration air outlet Condensate outlet Page 7 of 8

Accessories The DA-CM1-230 switch-over control system enables the control of two redundant compressed air dryers in a compressed air system. The two dryers can be operated alternately while switching-over automatically. All dryers, provided with a «remote start/stop contact» or a «compressor synchronisation contact», can be directly connected to the switch-over control system without the need for any further modifications. The DA-CM1-230 also controls all required shut-off valves (no scope of supply) to open or close the compressed air line to a dryer (e.g. solenoid valves or valves with actuating drive for 230V AC supply voltage). Furthermore, additional input signals can be hooked up to the common alarm message of each dryer. Beside the power supply the DA-CM1-230 provides alarm inputs for condensate drains, differential pressure gauges, etc. for each dryer. The GSM Module DA-ETR-107 is an easy to install extension for all dryers with alarm contact. In case of an alarm a SMS message is send to up to 6 different recipients or, if supported by the provider, an email message. Within the message, the dryer type and serial number is transferred, if required. The programming can be done with a usual mobile phone, protected by the PIN code of the SIM card (no scope of supply) applied to the GSM module. The DA-ETR-107 is operated with 5-32V DC supply voltage. An internal battery ensures operation of up to 120 hours in case of loss of the supply voltage. The GSM module has an integrated antenna while an external antenna can be connected in the case of low signal levels. The Start-up device (minimum pressure valve) DA-VPM- protects the dryer from overload due to high flow velocities during pressure build-up of the compressed air system. For connection size G ½ to G 2½ spring loaded angle valves are offered (DA- VPM-B../16), providing an opening pressure of 3-5 bar (standard 3.5 bar). For connection size DN80 to DN250 butterfly valves with pneumatic actuator are offered (DA- VPM-F /11), directly operated by the working pressure while opening at 3 bar (full cross-section at 4 bar). Special versions with adjustable opening pressure or working pressures of up to 450 bar are available on request. Differential pressure gauges FAD01C with potential free alarm contact allow to hook up the differential pressure control of the pre- and after-filter to the common alarm message of each dryer. In order to avoid a false error report due to start-up conditions or short-time peaks, an alarm delay can be set in the dryer control unit. The alarm message then will just be generated, if a too high differential pressure was indicated during the entire delay time interval.... and many more. Please contact us. Page 8 of 8