HR100R. Mini Air Handling Unit - For Ducted Ventilation With Heat Recovery. Installation and Servicing Instructions

Similar documents
HR100R. Mini Air Handling Unit - For Ducted Ventilation With Heat Recovery. Installation and Servicing Instructions

HR200WK Through the wall Heat Recovery Ventilator

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

Centrif Duo & Centrif Duo Plus

WHHR Midi & Midi Lite

Lo-Carbon Quadra Centrifugal Fan

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

HOTLINE:

Lo-Carbon Quadra SELV

Lo-Carbon SELV Tempra

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Installation and Maintenance

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

Installation and Maintenance

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

Installation and Maintenance

Installation & Operating Instructions

Installation and Maintenance

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

Lo-Carbon Quadra Centrifugal Fan

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Installation and Maintenance

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Installation and Maintenance

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

Lo-Carbon T-series Window & Roof Models

Thank you for choosing EnviroVent

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

VENTILATION. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions. Models: HRX2-S, HRX2-B, HRX2-FP, HRX2-BFP

DUCTING FOR HRV SYSTEMS The distribution of airflows

Simply Silent Contour 4 (100mm) Axial Extraction Fan

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air.

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

Xcell 270 Longlife DC wholehouse heat recovery unit

Warnings, Safety Information and Guidance

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions

FLAT2000L/R. Low Energy Positive Input Ventilation Unit. Installation and Maintenance. Alternative inlet position. 2.1 Spigot Inserts.

Installation and Maintenance

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Installation & Operating Instructions

Purge Ventilation Unit. Product Manual. ventilation systems TP625

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX

High Power Range Hood

60cm Chimney Extractor

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

KUDOS. Instruction leaflet

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

irconcentre.co.uk airooncentre.co.uk

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

MEV-DC. Continuous Mechanical Extract Ventilation Units Installation and Maintenance. Figure 3. Fixing screw hole.

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

Domestic & Commercial Fans

HEX390 Heat Exchanger

FM900. Installation, Operation and Maintenance Instructions. Built-In Extractor

HRX-aQ Range. Mechanical Ventilation with Heat Recovery appliances. Installation and Operating Instructions

100cm Chimney Hood GB IE

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

Silhouette Installation and Wiring Instructions

Installation and Wiring Instructions

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

ART cm Island Curved Glass

MRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance

BT16.4SS-HK BT19.4SS-HK Cooker Hood

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

Thank you for choosing EnviroVent

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

Xpelair Simply Silent TM Contour Fan

Installation and Maintenance. Opus OK / Genie NKF1 Kitchen Extract Unit. Contents IMPORTANT WARNING IMPORTANT! Introduction WARNING!

BWTC6510GL Cooker Hood 60 cm Glass cooker hood in stainless steel. BWTC9510GL Cooker Hood 90 cm Glass cooker hood in stainless steel

OPUSXBOX - SMALL COMMERCIAL HEAT RECOVERY SYSTEM LOW DEPTH, HEAT RECOVERY UNIT WITH MULTIPLE SPIGOTS AND ECOSMART CONTROLS.

RWC Issue: F. Description: ARISTON WALL CANOPY Model Numbers: RHC60IX, RHC90IX. All dimensions in mm Model may vary slightly from images pictured

Transcription:

HR100R Please leave these instructions with the user Mini Air Handling Unit - For Ducted Ventilation With Heat Recovery Installation and Servicing Instructions

Contents Section Page 1.0 Introduction 4 2.0 Site Requirements 5 3.0 Installation 6 4.0 Electrical 10 5.0 Commissioning 11 6.0 Maintenance 12 7.0 Optional Extras 13 8.0 otes 14 3

1.0 Introduction 1.1 Description The Vent-Axia HR100R is a remote mounting unit to provide balanced ventilation with up to 70% heat recovery for applications where there is no immediate access to an external wall. The HR100R is ideal for installations involving internal bathrooms and meets building regulation requirements for this application. A two speed motor provides for constant low rate ventilation with a boost speed option. Fresh pre-warmed air from outside is continually provided to the room with simultaneous extraction of stale air and smells. Heat is transferred from outgoing air to the fresh air supply with zero cross contamination, maintaining internal temperatures and providing a fresh environment. 2.0 Site Requirements 2.1 Information 1. The unit must be sited and connected by a suitably qualified person and be in accordance with current U.K. Building Regulations and I.E.E. Wiring Regulations (BS 7671). 2. The unit is intended for permanent connection to the mains electrical supply. 3. The HR100R is intended for fixed wiring installation. 4. Ensure that the mains electrical supply is compatible with the product s rating label. 5. The unit must be sited away from direct sources of heat in excess of 40 C. 6. Do not site the ceiling diffusers in the vicinity of excessive levels of airborne oil or grease. 7. If the ceiling diffusers are installed in a room containing a fuel burning appliance, the installer must ensure that air replacement is adequate for both appliances. 8. The external grilles must be sited a minimum of 500mm away from the flue of gas or open fire appliances. This is to avoid back flow of gases entering the room. 9. All safety regulations and requirements must be strictly followed to prevent hazards to life and property both during and after installation and during subsequent maintenance or servicing. 4 10. Ensure the mains electrical supply is isolated before commencing installation, or maintenance.

3.0 Installation 3.1 Installing the Unit 1. Check that all components have been delivered, as identified in the delivery note. otify the supplier of any errors or omissions immediately. E100R Unit 2. Check the diagrammatic ducting layout drawing to ensure that the proposed duct routes, fan unit and air terminal locations can be accommodated. If in doubt, refer to the Technical Department. Mounting Platform 3. The unit is designed to be mounted horizontally. After noting the positions of the electrical connector, duct spigots and drainage connection for the unit, choose a suitable installation site for the unit. The most desirable location for the unit is normally within the roof space. Joist Condensate Trap (50mm Min) 4. ever locate the unit above a sleeping area. The most suitable position is normally above the landing or bathroom. The selected site must allow adequate space around the unit for the removal of the access panel and heat exchanger for maintenance and servicing puposes. 5. When installing the unit, a suitable platform must be made. This should be built from chipboard or blockboard (19mm preferred). This board should be raised enough to facilitate the mounting of the unit above joist level. 6. The unit must be positioned so that the condensate outlet can be trapped and the condensate conveyed properly with a continuous gradient to discharge through the gable or to the eaves gutter in the selected location. 7. Connect the drainage system as appropriate using PVC pipework, joined using PVC cement to ensure of watertight joints..b. The trap should be charged/filled before operating the system, and should be checked especially in summer. Also note that a blocked condensate outlet pipe due to insufficient pipe gradient will quickly lead to water damage. 6 8. A shell bit is recommended for drilling holes in the ceiling to accomodate the housings for supply and extract air terminals (SV100 and EV100). Make sure that you are not drilling into structural members, water or gas pipes or electrical cables and that there is room behind the plaster board for duct access and securing ring. Ceiling terminals should preferably be fitted equidistant from adjacent walls bearing in mind that coving may already be fitted or may be fitted at a later date.

3.0 Installation 3.1 Installing the Unit Terminal Housing Plaster Board Securing Ring / Back Plate (for fire valves) Securing Screw Terminal 9. Place the terminal housing in the hole in the ceiling and secure to the back ring with the four screws provided. 10. For two storey new build properties it is recommended that the ground floor terminal housings are secured in position in advance of the plasterboard panels being fixed, by obtaining a sheet of plasterboard of the type and thickness to be used. Cut a square of the sheet to just span two joists in the corner where the terminal is to be fitted. Remember that the edge of the sheet on the inner joist should only rest on half of the joist thickness. This allows a fixing surface for the next sheet of plasterboard to be secured to when it is fitted. Tack up the plasterboard in position on the ceiling and connect up and seal the duct and fittings. 11. For two storey existing properties it is necessary to lift the floor coverings at first floor level above the terminal positions to gain access to the terminal housings to secure and seal the duct and fittings. 12. Fix in position all vertical supply and extract air ducting being conveyed between ground floor ceiling level and the loft space. 13. The external grilles for intake and exhaust air should be positioned so that the exhaust air is not drawn in again. 14. If the grilles are fitted in the same gable at the same height, a minimum of 1m between grilles is recommended. 15. If the grilles are positioned above one another the distance apart should be at least 1m with the exhaust grille at the top. 16. Roof ventilators placed on the same roof surface should be positioned at the same distances as the grilles. 17. Always ensure that all exhaust grilles/roof ventilators are placed higher than the top edge of the highest window and at a distance of at least 1m from the nearest window. 7

3.0 Installation 3.1 Installing the Unit 18. External grilles placed in the soffit should be positioned at the same distances as indicated for gables. 19. The Quicktube Rigid UPVC duct system permits fast, easy assembly whilst ensuring pressure-proof system sealing. 20. The ducts are delivered in lengths of 3m and are easily shortened as required with a duct saw or a similar fine toothed saw. We recommend that you file the edges of the ducts after shortening. 21. Assemble the duct and fittings, following as closely as possible the diagrammatic ducting layout. Ensure that the duct is raised above joist level to allow for thermal insulation of the ducting. 22. Each straight length of duct is assembled using a flexible connector (QTC) to join the two ends, whilst 90 and 45 diversions and branches are accomplished with flexible fittings (QTB90, QTB45 and QTET). The duct is a push fit into the socket of the connector and fittings. 23. Once assembled the joints are secured with duct tape (DT30) to provide an airtight seal. Ensure that the tape is secured over the complete joint area to provide an airtight seal. 24. If the loft space is unheated the unit and ducting will require to be thermally insulated to preclude condensation occuring and to minimise heat loss. This requirement must be observed in the planning and routing of the duct system. 25. The insulation recommended is Alreflex 11 which comprises 3mm thick polyethylene bubble sheet laminated on the external surface with aluminium foil protected by a thin polythene film. The product is CFC and HFC free and has a surface spread of flame of Class 1 tested to BS476 Part 7/971. It should, however, be protected from open flames or sparks and stored apart from highly flammable materials. 26. The material provides resistance to heat loss from the distribution ducting and a highly effective vapour barrier when all joints are sealed with metallised tape. It is light but robust, not easily damaged in storage or during construction and is rot proof, water and vapour resistent, durable and can be expected to remain an effective insulant for the normal life span of a building. 27. The insulation is supplied in 1.5m long preformed sections for application to the ducting at the time of installation. All joints should be secured using the metalised tape (DTA30) provided to ensure that a continuous vapour seal is maintained. 28. The use of flexible ducting should be limited to an absolute minimum. If used it should be fully stretched in order to minimse pressure loss. 29. Offer the unit on to the mounting surface, ensuring that it is not susceptible to movement under operation. Use directional airflow indicators on the top of the unit to ensure the correct connection to external and internal vents. 30. Mate up the ducting as appropriate, ensuring that the airflow is in line with the directional indicators. 31. Determine the most appropriate siting position for the appropriate control. ormally, this would either be a manual control switch (BSW), pull-cord switch (PCSW) humidity switch (HS6) or speed control switch (VCO100). 32. Determine the appropriate wiring connections as outlined within section 4, and wire in accordance with current IEE Wiring Regulations, ensuring that the mains feed is isolated before making any connections. 8

4.0 Electrical 4.1 Electrical Connections Continuous ormal Speed HR100R Terminals Black 1 Brown 2 Blue Green/Yellow Continuous Boost Speed HR100R Terminals Black 1 Brown 2 Blue Green/Yellow 3 amp fused supply ive eutral 3 amp fused supply ive eutral 230V 50Hz 12W (normal) 31W (boost) OTE: Wiring must be via a 3A fused switched spur with a 3mm contact separation in each pole. The wiring should be suitably (BASEC or HAR) approved cable of appropriate current carrying capacity. For units switching to boost on operation of a light switch, an in-line timer (order code TIM2) should be wired into the circuit as shown below. VCO100: Manual ormal to Boost Speed Switching and O/OFF Control HR100R Terminals Black 1 Brown 2 Blue Green/Yellow 3 amp fused supply ive eutral BSW and PCSW: Manual ormal to Boost Speed Control HR100R Terminals TIM2 Terminals 1 0 2 S ink ight fitting if appropriate Mains via switched fused spur Switched live ive eutral Automatic Control The HR100R unit operates on continuous trickle ventilation. Operation of switch turns unit to boost ventilation. When switch is turned off units continue to operate on boost for a preset period - adjustable 2-30 minutes. HR100R Terminals 1 2 3 amp fused supply ive eutral The HR100R MUST OT be wired in conjunction with a light switch, units will fail. HS6: Automatic ormal to Boost Speed Control 3 amp fused supply HR100R Terminals 1 1 2 Black Brown Blue Green/Yellow 0 2 ive eutral HR100R Terminals 1 2 ight Switched ive ive eutral 3 amp fused supply 10

5.0 Commissioning 5.1 Commissioning the System Before starting to commission the system check the following: a) All ducting is in place and secured. b) The wiring is secure and correctly connected. c) The trap is in position, charged and will enable efficient removal of condensate. d) The unit is mounted appropriately in a position not susceptible to movement or damage. The scope of the commissioning procedure comprises: 1. Balancing the two airflows to achieve maximum heat exchanger efficiency. 2. Adjusting the two airflows to obtain the overall airflow rates and the individual terminal air flow rates as specified on the air change schedule. 3. An airflow meter must be used to set the correct airflows. OTE: The supply air terminal device is directional and incorporates a deflector plate. Ensure that the deflector plate is correctly positioned so that the active part of the terminal device is discharging to the room. 4. Set the control switch (BSW or PCSW) to normal speed or set the humidistat (HS6) at maximum and check that air is flowing in the correct direction at each terminal point. 5. Standard ceiling terminals type EV100 and SV100 are adjusted by turning the central screw and are locked in the set position by the locknut. 11

6.0 Maintenance Securing Screws 6.1 Cleaning the Unit Cover In addition to removing odours, providing fresh air and recovering heat, this unit extracts airborne impurities such as dust, dirt and grease. These gradually build up and detract from the efficiency and appearance of the unit. Securing Screws Heat Exchanger To ensure optimum performance, the unit should be cleaned every three to six months or at periods determined by the level of contamination experienced, and according to the following procedure. 1. Isolate the mains power supply. 2. Remove the four securing screws from either end of the cover. 3. Remove the cover. 4. Remove the heat exchanger from the unit. 5. Wash the heat exchanger in warm water using a mild detergent and dry thoroughly. Keep water away from all electrical components and wiring within the unit. If the filter cannot be cleaned, replacement is recommended. 6. Reassemble in reverse order. The heat exchanger should be repositioned with the Top label facing the front and pointing upwards. 12

7.0 Optional Extras 7.1 Ancillary Equipment Speed Control Switch Ref: VCO100 White plastic single gang switch for O/OFF control and ORMA/BOOST speed control of HR100R unit. Speed Control Switch Ref: BSW White plastic single gang switch for ORMA/BOOST speed control of HR100R unit. A metal black box for flushing mounting (Ref: MBB) and plastic back box for surface mounting (Ref: PBB) are available for use with the above controllers. Pullcord Control Switch Ref: PCSW 2 way ceiling mounted switch for ORMA/BOOST speed control of HR100R unit. A second PCSW can also be used for O/OFF control. Humidity Sensor Ref: HS6 Electronic humidity sensor with changeover relay output and adjustable switching point from 60% to 100% RH. In built temperature compensation (night time setback). Contamination protection sensor. Timer Ref: TIM2 Remote mounting timer box to provide O/OFF control or switching between the 2 speeds on operation of switched live. Over-run period adjustable 2-30 minutes. Internal Extract/Supply Grille Ref: ESG100 White plastic louvre grille designed to fit in the wall or ceiling and serves both extract and supply functions. 100mm diameter spigot connection. Internal Extract Valve Ref: EV100 Adjustable extract valve with 80mm long, 100mm diameter spigot connection. Moulded in white plastic, the EV100 valve is suitable for both ceiling and wall mounting and is 150mm diameter overall. Internal Supply Valve Ref: SV100 Adjustable supply valve with 80mm long, 100mm diameter spigot connection. Valve design ensures horizontal discharge of air for optimum diffusion. Moulded in white plastic, the EV100 valve is suitable for both ceiling and wall mounting and is 150mm diameter overall. Filter Ref: F100 Coarse in-line filter complete with reticulated foam element. Compatible with 100mm diameter ducting. External Push-Fit Wall Vent Ref: WC1 400mm long brown plastic duct and external grille with vaned rubber seal for push fit installation in external walls. Fits into pre-drilled hole of 115mm diameter. External Dual Wall Vent Ref: WC2 Combined supply and extract terminal with grey plastic external cowl, with 100mm diameter ducting. This vent is ideal for exposed installations. External ouvre Wall Box Ref: W100 Anodized aluminium external weather louvre with metal wall box 130 x 130mm and 174 x 174mm grille. 100mm diameter spigot connection. Ventilating Roof Tiles Ref: VT100 Moulded ventilation terminal tiles, available in a range of sizes, profiles and colours. 100mm diameter spigot connection. In-ine Heater Ref: IH100 Compatible with 100mm ducting, the IH100 provides a boost heat facility when required. Flexible Ducting Ref: AFD100 Aluminium ducting in 10m lengths. Ref: ACD100 Acoustically insulated ducting in 6m lengths. Ref: IFD100 Thermally insulated ducting in 6m lengths. Ref: PFD100 PVC ducting in 6m lengths. Quicktube 100mm rigid plastic ducting can also be used in conjunction with the HR100R unit. For details please see data sheet. 13