Pin, Spool & Strain Insulators

Similar documents
Introducing Low Voltage DC Grid Interconnects

ENERGY /// UNDERGROUND DISTRIBUTION UNDERGROUND DISTRIBUTION MEDIUM AND LOW VOLTAGE POWER PRODUCTS

Introducing Hermaphroditic Blade and Receptacle Connector

Quick Reference Guide Barrier Strips

SOLARLOK Interconnection System Installation Manual

Introducing SlimSeal SSL Connector

Introducing Solar Identification Labels

Introducing Inverted SMT Thru Board Connector

RAYCHEM MEDIUM VOLTAGE

WILDLIFE AND ASSET PROTECTION PRODUCTS

Insulation and Protection Enhancing the Reliability of Overhead Power Systems

ENERGY /// TE S RAYCHEM CABLE CLAMPS TE CONNECTIVITY S (TE) RAYCHEM CABLE CLAMPS

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv

ENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS

LOW POWER AND SIGNAL APPLICATION GUIDE APPLIANCES /// LOW POWER & SIGNAL APPLICATION GUIDE

Raychem Elastomeric Medium Voltage Push-on and Cold-shrink Applicable Terminations TFTI/TFTO

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

Reliable solutions for electrified railway systems

LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS

PlanarMag Product Technology

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

Standard and Customized Hand Tool Kits

Introducing Corcom CU Series 1U Height Power Entry Modules

RELIABLE SOLUTIONS FOR ELECTRIFIED RAILWAY SYSTEMS

Z-PACK TinMan 85 ohm Connector Overview

QUADRAX D-SUB CONNECTORS

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE

AMP SUPERSEAL 1.5 SERIES Connectors

Universal Connectivity Platform

S200 SHIELD TERMINATORS

HEAT SHRINK CABLE ACCESSORIES: A 40 YEARS PROVEN TECHNOLOGY FOR APPLICATIONS IN HARSH ENVIRONMENTS

Quick Reference Guide.050 Centerline Micro-MaTch Connector Series

Universal Connectivity Platform A Modular Approach to Infrastructure Design

Raychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv

MODEL 834M1 ACCELEROMETER

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

KILOVAC K1K High-Voltage Contactor

Raychem Raysulate Insulation Enhancement Systems

Introducing Corcom DB Series

Quick Reference Guide: Connectors for Mobile Devices

MODEL 4000A & 4001A ACCELEROMETER

TE Connectivity's AMP NETCONNECT Cable Management

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment

RENEWABLE ENERGY. Durable solutions for maximum efficiency and the promise of reliability. ENERGY PIONEERS IN POWER SOLUTIONS

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC)

HARTMAN Smart AC Contactors

Specification Status: Released

DEUTSCH 369 Series PCB-Mount Connectors Compact, Lightweight In-Line and Panel-Mount Connectors for Printed Circuit Board Applications

INDUSTRY /// RAIL T-CONNECTOR RSTI-68R-HT RSTI-CC-68R-HT RAIL APPROVED T-CONNECTORS FOR ROLLING STOCK- TYPE C INTERFACE

High Density Optical In-Line Dry-Mate Connector (ILC) High Performance Multichannel Fiber Optic Connectors

Hydraulic Crimping Systems

BUDI-M-SP. Building distributor. Introduction. Seals. Kit content. Accessories. Wrap around cable seals

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

Raychem Link Boxes. Cable Services Limited. Powering the UK

Signal Connectors for Topside and Subsea Applications

WILDLIFE AND ASSET PROTECTION

Undercarpet Cabling Products Undercarpet Power, Voice and Data Distribution

AUTOMOTIVE MINIATURE WIRE (AMW)

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

FC22 Compression Load Cell

Gas Discharge Tubes. Features: Benefits: Applications:

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

AXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10

FC23 Compression Load Cell

DP86 Constant Voltage with Fitting

HPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE

15203B 25203B 35203B Uniaxial Biaxia Triaxial

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

Tether and Umbilical Cables for Remotely Operated Vehicles

Specification Status: Released

OM-CP-Cryo-Temp Ultra Low Temperature Data Logger. Shop online at. omega.com For latest product manuals: omegamanual.

D5100 Industrial Differential Pressure Transducer

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

UNIQA-PRO SINGLE CRIMP WIRE PROCESSOR

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

Specification Status: Released

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

Standard SPECIFICATIONS FEATURES APPLICATIONS

TS105-10L5.5MM Thermopile Sensor

DEUTSCH D3 SERIES PCB CONTACTS FOR SERIES III-STYLE CONNECTORS

Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series. Energy Division

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

RP SERIES THERMAL PROTECTORS

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

Your Pick... One Solution

TESS WIRELESS SENSOR TAG DEMO V1.1

CII FCAC-150 Series Relay

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

D5100 Industrial Differential Pressure Transducer

Seal Kits for BUDI Enclosures

TE CONNECTIVITY S CYLINDER HEAD WIRING SOLUTIONS FOR INDUSTRIAL & COMMERCIAL VEHICLES

Ribbon Breakout Kit Installation Instructions

TESS WIRELESS SENSOR TAG DEMO V1.1

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

CONTACTORS FOR AEROSPACE GROW SMARTER AND MORE CAPABLE

Transcription:

Pin, Spool & Strain Insulators

TE Connectivity Pin, Spool & Strain Insulators Pin, SpooL, Strain Insulators TE Energy rounds out the insulator offering to include spool, pin and strain insulators. TE s porcelain insulators were sold in the past with brand names of Morlynn, Dulmison and Zibo, and have 95 years of service experience in electric power supply and rail applications. Manufactured from high-quality non-porous electrical porcelain, they provide long life and cost-effective solutions for a majority of applications. Contact your TE Energy sales representative for more information and for other applications not found in this brochure. porcelain Pin Type Insulators Critical Low Impulse Frequency Pin Leakage Flashover Flashover Cantilever Dry Arc Puncture Max. Description Type Distance Pos./Neg. Wet/Dry Strength Distance Voltage RIV Diameter Height (in) (kv) (kv) (lbs) (in) (in) PI-55-1-PSG 55-1 4 50/70 20/35 3000 2.25 50 50 3.25 3.50 PI-55-2-PSG 55-2 5 70/85 25/45 2500 3.38 70 50 3.75 3.25 PI-55-3-PSG 55-3 7 90/110 30/55 2500 4.49 90 50 4.75 3.75 PI-55-4-PSG 55-4 9 105/130 35/65 3000 5.00 95 50 5.50 4.38 PI-55-5-PSG 55-5 12 130/150 45/80 3000 6.26 115 100 7.00 4.88 PI-55-6-PSG 55-6 12 150/170 50/100 3000 8.00 135 100 8.38 5.50 Above descriptions designate gray and semicon glaze. For other designs and custom-made products, please contact your TE Energy sales representative. Porcelain Pin Type Insulator, F Neck te.com/energy 2

TE Connectivity Pin, Spool & Strain Insulators Porcelain Pin Type Insulators Critical Low Impulse Frequency Pin Leakage Flashover Flashover Cantilever Dry Arc Puncture Max. Description Type Distance Pos./Neg. Wet/Dry Strength Distance Voltage RIV Diameter Height (in) (kv) (kv) (lbs) (in) (in) PI-56-1-PSG 56-1 13 150/190 60/95 2500 7.0 130 100 7.50 5.75 PI-56-2-PSG 56-2 17 175/225 70/110 3000 8.3 145 100 9.00 6.50 PI-56-3-PSG 56-3 21 200/265 80/125 3000 9.5 165 200 10.5 7.50 PI-56-4-PSG 56-4 27 225/310 95/140 3000 11.3 185 200 12.0 9.50 S designates semicon glaze applied to upper side of the insulator. Above descriptions designate gray and semicon glaze. For other designs and custom-made products, please contact your TE Energy sales representative. PI RR a M M F n Porcelain Pin Insulator Code Number Indicates special modifications ANSI Series Color Brown, Grey ANSI Reference Number Housing S for semicon glaze on porcelain Optional Material Porcelain Porcelain Pin Type Insulator, J Neck te.com/energy 3

TE Connectivity Pin, Spool & Strain Insulators Porcelain STRAIN Low Low Frequency Frequency Mechanical Flashover Flashover Leakage Failure Load Description Dry Wet Distance Load Height Diameter (kv) (kv) (in) (lbs) (in) (in) MG-54-1-PG 25 12 41 10000 3.50 2.52 MG-54-2-PG 30 15 48 13000 4.25 2.87 MG-54-3-PG 35 18 57 20000 5.50 3.39 MG-54-4-PG 40 23 76 20000 6.75 3.50 For other designs and custom-made products, please contact your TE Energy sales representative. MG 54 a M F n Porcelain Strain Insulator Code Number Indicates special modifications ANSI Designation Color Grey, White ANSI Reference Number Material Porcelain porcelain Strain te.com/energy 4

TE Connectivity Pin, Spool & Strain Insulators porcelain Spool Low Low Frequency Frequency Flashover Flashover Vertical\Horizontal Transverse Description Dry Wet Height Strength (kv) (kv) (in) (lbs) MS-53-1-PG 20 8/10 2.13 2000 MS-53-2-PG 25 12/15 3.00 3000 MS-53-3-PG 25 12/15 3.19 4000 MS-53-4-PG 25 12/15 3.00 4500 MS-53-5-PG 35 18/25 4.13 6000 For other designs and custom-made products, please contact your TE Energy sales representative. MS 53 a M F n Porcelain Spool Insulator Code Number Indicates special modifications ANSI Designation Color Brown, Grey, White ANSI Reference Number Material Porcelain porcelain Spool te.com/energy 5

FOR MORE INFORMATION te.com/energy TE Technical Support Center USA: +1 (800) 327-6996 Canada: +1 (905) 475-6222 Mexico +52 (0) 55-1106-0800 Latin/S. America: +54 (0) 11-4733-2200 UK: +44 (0) 800-267666 France: +33 (0) 1-3420-8686 Netherlands: +31 (0) 73-6246-999 China: +86 (0) 400-820-6015 energy.te.com 2011-2012 Tyco Electronics Corporation, a TE Connectivity Ltd. Company. All Rights Reserved. 8-1773462-9 E458 07/2012 TE Connectivity and TE connectivity (logo) are trademarks. Other logos, product and/or company names might be trademarks of their respective owners. While TE has made every reasonable effort to ensure the accuracy of the information in this brochure, TE does not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any time without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this catalog are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE for the latest dimensions and design specifications.