Infrared Temperature Sensor

Similar documents
Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

User s Guide OS-MINI22 SERIES. Shop online at omega.com SM. For latest product manuals: omegamanual.info

Innovative Technology for Traditional and Challenging Applications

RS Pro Infrared Temperature Sensor

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

More Precision. thermometer // Non-contact IR temperature sensors

SPOT HIGH PRECISION PYROMETERS A PRODUCT OF THE SYSTEM 5 FAMILY. 50 to 1800 C / 122 to 3272 F QUALITY CUSTOMER SOLUTIONS

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

EC100. Thermal Imaging System for Quality Control in Extrusion Processes EC100 PROCESS IMAGING SYSTEM

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Dual Laser InfraRed (IR) Thermometer

Maxline 2 Thermal Imaging Solutions for Manufacturing

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

More Precision. thermometer // Non-contact infrared temperature sensors

SS-100. Pyrometer. Temperature Range: 800~2400

Process & TeMPerATUre UniversAl input DigiTAl MeTers

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

Raytek /Ircon Solutions Guide. The Worldwide Leader in Noncontact Temperature Measurement

Raytek /Ircon Solutions Guide

Modline. 5 Stand Alone Temperature Sensor. You can bet your process on it!

Film Extrusion, Extrusion Coating, and Lamination Processes

Dual Laser InfraRed (IR) Thermometer

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

IRT2 Dual Laser IR Thermometer - User Guide

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

I/R Thermometer Gun 12:1

Address: 2857 Sherwood Heights Dr. Unit 2, Oakville, ON, Canada. L6J 7J9 Toll free: LOGIKA

EasyLog Data Logger Series

EasyLog Data Logger Series

Danfoss gas detection units

High Temperature InfraRed Thermometer with Laser Pointer

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

OPERATING INSTRUCTIONS. G214 Software - Version 4

XSD Dry Cabinet. Outstanding performance. The XSD series has an outstanding performance for drying moisture sensitive components and pcb s.

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

UDC100 Universal Digital Controller Specifications

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

Users Manual. Visit us at

Model 4150 FAST. FOCUSED. CONTROLLED. Infrared Heaters For Controlled Concentrated Heating. Infrared Heat. Instantaneous Results.

Visit us at testo 835 Infrared and contact thermometer

User Manual. Humidity-Temperature Chart Recorder. Model RH520

AS950 PORTABLE SAMPLERS

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

AS950 REFRIGERATED SAMPLERS

Danfoss gas detection unit Type GD Heavy Duty

RS485 MODBUS Module 8AI

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

LCF Touch Modbus Datasheet Application Security Advice Caution

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

ACTIVE INFRARED BARRIER

I/A Series 716C 1/16 DIN Temperature Controller

Turbimax CUE21 / CUE22

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Open-area Smoke Imaging Detection (OSID)

Sintrol Snifter A2 EX. Manual. Version 1.2.3

Alarm module for leak detection with webserver

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

User s Guide OS210-C4. IR Temperature Sensors. Shop online at omega.com. For latest product manuals: omegamanual.

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

SCAN200E USER S MANUAL

MR SERIES CARD LOGGERS

Manual PCE-889 pyrometer

optris TM Temperature Monitor for Infrared Sensors Operators manual

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

ACCESS Master MT9085 Series. Product Introduction

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Lift Station Level Controller

Reliable Detection of Transparent Objects

Dräger Polytron Pulsar 2 Open Path Gas Detector

FACTORY AUTOMATION SENSE WITH SIMPLICITY AND CONFIDENCE PHOTOELECTRIC FIBER AMPLIFIER SU18 AND SU19 SERIES

HOBO U14 Data Logger User Manual

7800 SERIES RM7888A Relay Module

RACK MONITORING SYSTEM - RAMOS Ultra

Radiant Process Heaters. Gemini. Medium Wave Heaters Twin Bore Quartz Tube Technology

Precision Infrared Thermometer. Users Manual

CMT MANUAL 6. NMC SENSORS

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

OIL FILM DETECTOR (Long-distance correspondence Version)

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

LCF Touch (from firmware version 1.7)

S304 and S305 Dust Emission Monitors. User Manual. Distributor

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

XSD Dry Cabinet

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

Improving Quality and Productivity with Non-Contact Temperature

Key Features. General Description

Variable Frequency Drive SERIES MP800 VFD

PRO SERIES NONCONTACT TEMPERATURE SENSORS

More Precision. thicknesssensor // The sensor for precise thickness measurements

Transcription:

Infrared Temperature Sensor With High Speed Sensor, Small Measured Spot and Continuous LED Sighting OS-PC Series U High Speed Cube Sensor with Optional Touch Screen Display U Response Time 0.001 Seconds (-PCF Models) the Fastest in the World U Measures from 0 to 500 C (32 to 932 F) U Ideal for Small Targets Measurement Area as Small as 1.6 mm Diameter U Continuous Red LED Sighting on all Models Shows the Position and Size of the Measurement Spot While Readings are Being Taken U Multilingual Touch Screen Interface (Optional) for Temperature Display, Data Logging, Sensor Configuration and Alarms U Measures Surface Temperature of Paper, Thick Plastics, Food, Rubber, Electronic Components, Cable, Ceramics, Textiles, Painted Surfaces and Some Metals, as Well as Many Other Materials The OS-PC cube is an infrared pyrometer with an extremely fast response time and a very small measurement area size. It is available with or without the OS-PC-TSD touch screen interface. The sensor is designed for applications where an extremely fast response time is required, or where the object to be measured is very small. It is an ideal temperature sensor for blow molding preform measurement, as well as applications in the food industry, laboratories, and many others. Typical Applications Include: Cable Manufacturing It is now possible to monitor the temperature of insulation and sheathing as they are applied to very narrow cables, avoiding manufacturing defects and ensuring highly repeatable product quality. Plastics Extrusion of plastic tubing and profiles requires temperature control to ensure consistent quality. The tube or profile can be narrow, so the very small measured spot of the OS-PC cube sensor is ideal. If the die is changed, the aiming angle of the sensor must often be adjusted, and the continuous LED sighting makes this easy. 1 OS-PC-TSD touch screen display, sold separately. OS-PC16-2M cube sensor, shown smaller than actual size. Electronics: PCB Testing When testing the function of circuit boards, small components can heat up very quickly. The OS-PC cube sensor can monitor the temperature of very small components and read their surface temperature instantaneously. Food The OS-PC cube sensors advanced peak hold functionality is ideal for fast-moving conveyors, especially in food production. With the OS-PC cube sensor, it is now possible to measure the temperature of thousands of individual items every minute.

OS-PC16 Sensor Specifications Temperature Range: 0 to 500 C (0 to 932 F) Response Time: 95% F Models: 1 ms Standard Models: 10 ms Averaging Function: Adjustable up to 5s Target Sighting: Red LED built-in as standard on all models, shows the position and size of the measurement area; switchable on/off* *LED sighting and alarms Accuracy of Measurement: ±3 C (±5.4 F) or 1%, whichever is greater Ambient Temperature: 23 ±5 C, emissivity 1.0, averaging time 50 ms Repeatability: ±0.5 C (0.9 F) Ambient Temperature: 23 ±5 C, emissivity 1.0, averaging time 50 ms Temperature Resolution: <0.5 C (0.9 F) Emissivity Setting: Adjustable, 0.3 to 1.0, via RS232C or optional touch screen interface ENVIRONMENTAL Weight: 85 g (3 oz), without cable Environmental Rating: IP67 Operating Ambient Temperature: 0 to 50 C (32 to 122 F) Storage Temperature: -15 to 70 C (5 to 158 F) Operating Ambient Humidity: 30 to 85% RH non-condensing Sensor Only: These functions are selectable via RS232C and share a common connection, which is configurable either as an input to switch the LED sighting on/off, or an open drain alarm output, but not both at once Sensor with OS-PC-TSD: These functions may be configured via the OS-PC-TSD interface; two alarm relay output OS-PC30 OS-PC55 OS-PCF35 OS-PC-TSD Specifications Touch Screen Display Format: 72 mm (2.83") resistive touch TFT, 320 x 240 pixels, backlit Configurable Parameters: Language (English, Chinese, Japanese), temperature units C/ F, displayed temperature, LED sighting on/ off, password, date and time (for data logging time stamps), peak hold period, decay level, averaging period, correction (gain/offset), emissivity setting (with teach function), reflected energy compensation (with teach function), output type, output temperature range, polarity on error, alarm mode, levels, hysteresis OS-PC-TSD Data Logging Specifications Optional wall-mounted display, data logging, configuration and alarm unit for OS-PC sensor Outputs (From Touch Screen Module): Retransmitted analog output from sensor, plus 2 relays, rated 24 Vdc, 1 A Output Type Effective Minimum Output Temperature Reading: Large, bright backlit temperature display turns red in alarm condition Temperature Recording History: Graphs of measured temperature, log more than a year of data to a single MicroSD card; data is stored in a simple text format easily imported into Excel Sensor Configuration: Configuration settings can be adjusted via the intuitive touch screen interface Temperature Alarm Triggers: Two alarms are individually configurable as high, low, band or error; red screen to signal alarm condition, built-in 24V, 1 A relay outputs can be connected directly to alarm Measurement Accuracy: Accurate, even with reflections of hot objects; measure the temperature of objects using Reflected Energy Compensation feature Output Accuracy (Additional to Measurement Accuracy) 0 to 1 Vdc 30 mv ±1.5 mv mv/ C 30 mv ±1.5 mv 0 to 20 ma 0.2 ma ±0.02 ma 4 to 20 ma 4.0 ma ±0.02 ma OS-PCF70 Storage: MicroSD card (optional), max 32 GB, equal to 16 years of data at the fastest sample rate of 1 per second Data Logging Interval: 1 second to 1 day (configurable) Internal Clock Battery: One BR 1225 3V (not included) Variables Logged: Instant target and hold temperatures, alarm events 2 File Format:.csv Configurable Parameters (Data Logging): Sample period, number of samples, scheduled start Configurable Parameters (Alarm Logging): Log times when triggered, acknowledged, reset; log data while triggered

Electrical Specifications Outputs: 1 analog output and 1 alarm output Analog Output: 4 to 20 ma (set by default), 0 to 20 ma, mv/ C or voltage, selectable via optional OS-PC-TSD touch screen interface Alarm Output: 1 open drain alarm output, rated 27 Vdc, 0.2 A* Supply Voltage: 5 to 27 Vdc, 100 ma max Digital Communications: RS232C MODBUS RTU, non-isolated To Order OS-PC{Response Time & Optics}-{Cable Length}-{Voltage Analog Output Option} Response Time & Optics 16 10 ms response, 1.6 mm spot @ 35 mm 30 10 ms response, 3.0 mm spot @ 70 mm 55 10 ms response, 5.5 mm spot @ 120 mm F35 1 ms response, 3.5 mm spot @ 100 mm F70 1 ms response, 7.0 mm spot @ 200 mm Cable Length 2M 2 m (6.6') 5M 5 m (16.4') 10M 10 m (32.8') Voltage Analog Output* Option 1V 0 to 1 Vdc 5V 0 to 5 Vdc 10V 0 to 10 Vdc *Note: All units include as standard 0 to 20 ma, 4 to 20 ma and mv/ C outputs. Ordering Examples OS-PC16-2M-(*) High speed cube sensor with 10 ms response, 1.6 mm spot @ 35 mm with 2 m (6.6') cable OS-PC30-2M-(*) High speed cube sensor with 10 ms response, 3.0 mm spot @70 mm with 2 m (6.6') cable OS-PC55-2M-(*) High speed cube sensor with 10 ms response, 5.5 mm spot @ 120 mm with 2 m (6.6') cable OS-PCF35-2M-(*) Very fast cube sensor with 1 ms response, 3.5 mm spot @ 100 mm with 2 m (6.6') cable OS-PCF70-2M-(*) Very fast cube sensor with 1 ms response, 7.0 mm spot @ 200 mm with 2 m (6.6') cable * Voltage analog output option, see below. OS-PC-FBN Fixed mounting bracket OS-PC-PWC Protective lens cover OS-PC-APC Air purge collar OS-PC-ADP Airless dust protector Options/Accessories OS-PC-TSD OS-PC-FBN OS-PC-PWC OS-PC-APC OS-PC-ADP Touch screen display ( C/ F) with data logging Fixed mounting bracket (1-axis) Protective lens cover Air purge collar Airless dust protector Comes complete with operator s instructions. Ordering Examples: OS-PC16-2M-1V, high speed cube sensor with 10 ms response, 1.6 mm spot @ 35 mm with 2 m (6.6') cable and optional 0 to 1 Vdc analog output. OS-PCF35-5M-5V, very fast cube sensor with 1 ms response, 3.5 mm spot @ 100 mm with 5 m (16.4') cable and optional 0 to 5 Vdc analog output. 3

Pyrometers for Special Applications Type S F G Application General purpose Fast response Glass The general-purpose S is suitable for measuring most non-reflective non-metals Advantages over other general purpose sensors are the built-in LED aiming light, fast response time, and small measured spot size. The F has a lightning-fast response time of 0.001 seconds. Glass-specific measurement wavelength for improved accuracy when measuring glass surface temperature. G models are ideal for annealing, e.g. light bulb and fluorescent lamp manufacturing. GH models are suitable for high-temperature glass melting, such as in glass-to-metal sealing. Wavelength 2 to 7 µm 2 to 7 µm 5 µm Temperature Range Response Time OS-PC Focal Spot Diameter (mm) 0 to 500 C (0 to 932 F) 50 to 1200 C (122 to 2192ºF) 50 to 2400 C (122 to 4352ºF) 10 ms 1 ms 50 ms 10 ms 16 30 55 F35 F70 G70 G200 GH22 GH45 1.6 3 5.5 3.5 7 7 20 2.2 4.5 Focal Distance (mm) Maximum Measurement Distance (mm) 35 70 120 100 200 180 500 150 300 150 200 300 300 500 500 1000 300 500 4

Pyrometers for Special Applications Type P XS M Application Thin film plastics Very small targets Metals, low temperature Accurately measures the temperature of thin film plastics that cannot be measured with generalpurpose sensors. Materials include polyolefin, polyamide, polyethylene, polypropylene, polystyrene, nylon, PVC, acrylic, polyurethane and polycarbonate. Extremely small measured spot size. Applications include measuring individual electronic component temperatures on a circuit board, and plastic welding where the seam is very narrow. Short-wavelength sensors for measuring metals as cool as 50 C (122 F), with a very fast response time of 0.001 seconds and a very small measured spot size. Wavelength 3.4 µm 5 to 7 µm 2.2 µm Temperature Range Response Time OS-PC Focal Spot Diameter (mm) 80 to 350 C (176 to 662ºF) 0 to 500 C (0 to 932 F) 50 to 600 C (122 to 1112ºF) 10 ms 10 ms 50 ms 1 ms P120 XA7 XB10 MA10 MA20 MA35 MB110 12 0.7 1 1 2 3.5 11 Focal Distance (mm) Maximum Measurement Distance (mm) 200 40 100 50 100 200 200 500 100 300 100 200 400 500 5