SCHMIDT LED Measured Value Display MD Instructions for Use

Similar documents
SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Universal controller for panel mounting Models CS6S, CS6H, CS6L

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

RCMA423-DM RCMA423-DM1C RCMA423-DM2C RCMA423-DM3C. Operating Manual

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Original operating instructions Safety switch with guard locking AC901S AC902S

Operating Manual VMD420

Operating Manual MS220DA

Operating instructions

1.7. Insulation fault evaluators EDS460/490 EDS461/491

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

PolyGard 2-channel Gas Controller MGC-03

Operating Manual RCM420

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

FLAME AMPLIFIER MODULE 3001D

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

Process Alarm Module RTA 421

M-Sens 2. Online moisture measurement for solids. Operating Instructions. SWR engineering Messtechnik GmbH PART OF THE ENVEA GROUP

Combi B Alarm box. Mounting instructions

Instructions for the fan motor control system with integrated wiring terminals SILVER C

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Electronic Temperature Controller 70304,

English. Operating manual. Safety temperature limiter STL50 Approved in accordance with: DIN EN (replacing DIN 3440) SIL 2

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

R1000 / R1040 / R1080

DNC-PS700-A10 Differential Pressure Control Meter. Operation and Installation Manual

02/11/2015

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Digital Display DS 52 in wall housing. Order no

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

WIO200 Water In Oil measuring instrument

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

CD30 Codoor. Instruction Manual

DIGITAL METERS Large Display Temperature Meters Instruction Manual

5, SE GÅNGHESTER,

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

1.7. Insulation fault evaluators EDS460/490 EDS461/491

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Instructions for the fan motor control system, SILVER C

02/11/2015

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

Line Isolation Monitor (LIM) LIM2000plus

eed quality electronic design USER s MANUAL

Analog Room Pressure Monitor RPC Series

Beacon 410A Gas Monitor Operator s Manual

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Greentrol Automation, Inc.

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Air Comfort. Installation instructions (English) A

Turbimax CUE21 / CUE22

CU 300. Installation and operating instructions GRUNDFOS INSTRUCTIONS

RESISTRON. Replacing RES-102/RES-420. Replacement Instructions. Comparison of RES-102 / RES-420. Dimensions. Temperature indication (actual value)

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

Radio fire warning panel SRC 3000

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Stand Alone DYNAGARD SP Operation Manual

E21.X.01.6C-05 Operating Manual EB2000 MC page 1. Operating manual EB2000 MC. for up to 9 sensor modules. Version 3.0

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

Insulation fault evaluator EDS460-DG

PolyGard Controller LGC/LG2-04. Multi-Point Controller Serial Number S00 User Manual Preliminary Version. August 11, 2006

I/A Series 716C 1/16 DIN Temperature Controller

Temperature-Relay TR210

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

DOCUMENTATION IPS640

Oxygen (O2) Single-Point Gas Detection System

ACS-30-EU-EMDR- 10-MOD

OVEN INDUSTRIES, INC.

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

WIO 200B and WIOI200B Water in oil sensor

ST Wiring diagram. Product description. Standard temperature controller. Order number

JDDT1 - Single Stage Digital Thermostat

compact office 24V compact office 24V Lux

Preamplifier Power Supply PPS-02 user's guide

SET Installation and Operating Instructions. Level switch for one sensor

MANUAL Overflow sensor NVF-104/34-PF

Transcription:

SCHMIDT LED Measured Value Display MD 10.010 Instructions for Use

Table of Contents 1 Important Information... 3 2 Application range... 4 3 Mounting instructions... 4 4 Electrical connection... 6 5 Signalizations... 8 6 Startup... 9 7 Service information... 19 8 Technical data... 20 9 EC Declaration of conformity... 21 Legal note: Copyright 2011 SCHMIDT Technology All rights reserved Version 531010.02C Subject to modifications Instructions for use MD 10.010 Page 2

1 Important Information These instructions for use contain all the required information for a fast commissioning and a safe operation of SCHMIDT LED measured value displays: These instructions for use must be read completely and observed carefully, before putting the unit into operation. Any claims under the manufacturer's liability for damage resulting from non-observance or non-compliance with these instructions will become void. Tampering with the device in any way whatsoever - with the exception of the designated use and the operations described in these instructions for use - will forfeit any warranty and exclude any liability. The unit is designed exclusively for the use described below (refer to chapter 2). In particular, it is not designed for direct or indirect personal protection. SCHMIDT Technology cannot give any warranty as to its suitability for a certain purpose and cannot be held liable for accidental or sequential damage in connection with the delivery, performance or use of this unit. Symbols used in this manual The symbols used in this manual are explained in the following section.! Danger warnings and safety instructions - please read them! Non-observance of these instructions may lead to injury of the personnel or malfunction of the device. General note All dimensions are indicated in mm. Instructions for use MD 10.010 Page 3

2 Application range The SCHMIDT LED measured value display MD 10.010 (material numbers: 527320 and 528240) is used to display measured values which are transmitted by a sensor in form of an analog signal (current or voltage). The supply voltage of the sensor can be provided by the LED measured value display. Switching points for two alarm outputs can be derived from the input signal. The galvanically isolated analog output is able to send the modified input signal. The SCHMIDT LED measured value display MD 10.010 can also be used for SCHMIDT flow sensors as well as for other sensors (e.g. pressure, temperature, humidity) which are equipped with standard analog outputs. The SCHMIDT LED measured value display MD 10.010 is designed for the use inside closed rooms and is not suitable for outdoor use (risk of condensation on electronic parts). Moreover, the uses in safety relevant applications are not allowed. 3 Mounting instructions Dimensions Figure 1: Dimensions of the housing Instructions for use MD 10.010 Page 4

Wall mounting The measured value display is installed on the wall by means of four screws. The distances of the holes are indicated in Figure 1. Please make sure that there is enough space to open the upper part of the housing in order to establish the electrical connection. Lateral through-bolt joints After installation of the measured value display, the through bolt joints included in the delivery can be mounted instead of the dummy plugs. Opening the housing To establish the electrical connection, the housing must be opened. For this, loosen the four screws on the housing. To facilitate the opening of the housing, loosen the screws, pull them to the top as far as possible and fix them in the cover by turning them to the left.! During electrical installation ensure that no voltage is applied and inadvertent activation of the operating voltage is not possible. As a result of the design, the components susceptible to ESD inside the open housing are not protected against unintentional contact. The terminals are resistant to ESD in contrast to the other parts of the electronic system (e.g. cover board with configuration jumper). In order to avoid damages to the electronic parts, make sure that no ESD spark can be transmitted to the electronic parts (e.g. electronic discharge of the operating person on a grounded object before opening the housing).! Take respective protective measures to avoid damages due to electrostatic discharge (ESD). Instructions for use MD 10.010 Page 5

4 Electrical connection!! During electrical installation ensure that no voltage is applied and inadvertent activation is not possible. The electrical connection must be carried out by trained and qualified personnel. Figure 2: Terminals Terminal Designation Function 1-3 Relay 1 Alarm output 1 (max. 250 VAC / 5 A) 4 Sensor 1 In- GND 5 Sensor 1 In+ 6 Sensor 1 24V - GND 7 Sensor 1 24V+ Analog input 1 (jumper Ch.1 for configuration of current or voltage input) Supply voltage of the sensor (24 V ± 15 %, max. 160mA) 12 Analog Out - AGND (galvanically isolated from GND) 13 Analog Out+ Analog output 14-15 Supply Voltage Operating voltage according to the version: DC: (14) 24V, (15) GND AC: (14), (15) 16-18 Relay 2 Alarm output 2 (max. 250 VAC / 5 A) Table 1: Connection Instructions for use MD 10.010 Page 6

Operating voltage For the proper operation, the measured value display requires DC voltage with a nominal value of 24 V with permitted tolerance of ± 20% (material No. 528240) or an AC voltage between 85 and 250 VAC (material No. 527320).! Only operate the measured value display in the defined operating voltage range and with the respective voltage type. Undervoltage may result in malfunction, overvoltage may lead to irreversible damages. Analog input The jumper in the housing cover can be used to switch the analog input of the display between current and voltage signal. If the bridge is placed on the left contact pins (Voltage) a voltage signal is expected. If the plug connects the right pair of pins (Current), a current signal must be active. Figure 3: Jumper current/voltage input in the housing cover Instructions for use MD 10.010 Page 7

Analog output The analog output of the MD 10.010 is galvanically isolated from the energy supply and the sensor. Depending on the value of the measuring resistance R L (switching threshold: R L = 500 Ω), the signal electronics switches automatically between the operation as voltage interface (U) or current interface (I). In the configuration menu, a beginning of the measuring range without offset (0 ma or 0 V) or with offset (signal transmitting zero point: 2 V or 4 ma) can be selected. 5 Signalizations Display Display Display flashes Table 2 State Initialization of measured value display. Duration approx. 5s after having switched on the supply voltage Key lock activated Error message of the sensor Area that can be displayed is exceeded or not reached Analog output If the connected sensor indicates an error, the error is also transmitted to the analog output: Output area without offset: 0... 20 ma and 0... 10 V In the current mode the interface outputs 0 ma. In the voltage mode the output switches to 0 V. Output area with offset: 4... 20 ma and 2... 10 V In the current mode the interface outputs 2 ma. In the voltage mode the output switches to 1 V. Instructions for use MD 10.010 Page 8

6 Startup Before switching on the SCHMIDT measured value display MD 10.010, check whether the device is installed correctly, both mechanically and electrically. If the measured value display is in the correct operational state, the display is ready for operation approx. 5 s after switching on the supply voltage. Operating and display elements Figure 4: Operating and display elements Instructions for use MD 10.010 Page 9

General After switching on the supply voltage, the device is ready for operation as a standard display device and indicates the current measured value and the states of the alarm outputs. The device can be operated by means of two different menus. In both menus, the menu items are selected using the parameter key. The settings in the selected menu item can be modified using the arrow keys. Shortly press the parameter key to open the display menu. In this menu, the current measured values, the minimum and maximum values and the switching points of the alarm outputs can be selected. If no key is pressed for more than two minutes, the device returns automatically to the main display. If the parameter key is pressed for more than 2 s, the configuration menu opens. It can be used to configure the measuring input (sensor signal), both alarm outputs and the analog output. The configuration menu of the display is left automatically after the last menu item or if no key is pressed for more than 2 minutes. It can also be quitted at any time by a long press on the parameter key. The labels included in the delivery can be placed on the unit field to indicate the desired measuring unit (e.g. m/s, m³/h,... ) of the main display. States of the alarm outputs Display State Table 3 Alarm output 1 not activated Alarm output 2 not activated Alarm output 1 activated Alarm output 2 not activated Alarm output 1 not activated Alarm output 2 activated Alarm output 1 activated Alarm output 2 activated Instructions for use MD 10.010 Page 10

Example application 1 step by step With a flow sensor (measuring range 0 40 m/s and 4... 20 ma output signal) the flow velocity shall be indicated in m/s. But on the analog output only a measuring range of 1.0 up to 20.0 m/s shall be displayed as 4 20 ma signal. When exceeding 15.0 m/s an alarm signal is output through the relay. - Installation of LED display in required position - Plug the jumper for current measurement according to the input signal in the housing cover - Connect the analog output of sensor to the LED display - Connect analog output and relay output 1 - Connect current supply and close the housing - After switching on the supply voltage: Initialization followed by indication of an unconfigured main value on the display - Call-up of configuration menu by pushing for 2 seconds Menu item Setting Description No value averaging Configuration analog input: Signal mode analog input: 4... 20 ma. Accuracy of indication: 2 decimals. Start value: 0 m/s (corresponds to 4 ma ). End value: 40 m/s (corresponds to 20 ma ) Configuration alarm output 1: Activation of alarm output Switching mode: active when exceeding. Switching point: 15 m/s. No switching hysteresis.. No response delay.. No release delay Alarm output 2: deactivated Instructions for use MD 10.010 Page 11

Menu item Setting Description Configuration analog output: Activation analag output Signal mode: 4... 20 ma. Start value: 1 m/s ( 4 ma). End value: 20 m/s ( 20 ma) No operation lock After the final menu item the configuration menu is left automatically for changing to the main display - Verification of the indication values on the display menu Menu item Indication Description. Main display = measurung value sensor. Raw value sensor 1 (9.12 ma). Peak-value memory Maximum measuring value of the sensor selected for the main display Deletion of the maximum measuring values of both sensors by using for approx. 5 s. Peak-value memory Minimum measuring value of the sensor selected for the main display Deletion of the minimum measuring values of both sensors by using for approx. 5 s. Switching point alarm output A1 Alarm output A2 switched off Instructions for use MD 10.010 Page 12

Example application 2 step by step With a flow sensor (measuring range 0 60 m/s) installed into a DN 50 tube and 4... 20 ma output signal the measuring value in m³/h shall be indicated. The analog output of the LED display shall be 4... 20 ma: 4 ma = 0 m³/h and 20 ma = 200 m³/h. As soon as 150 m³/h are exceeded a switching signal will be required. - Determination of the volume flow measuring range of sensor (available from sensor instruction manual or by means of the SCHMIDT flow calculator under www.schmidttechnology.com ): 60 m/s 343 m³/h - Installation of LED display in required position - Plug the jumper for current measurement according to the input signal in the housing cover - Connect the analog output of sensor to the LED display - Connect the analog output and relay output 1 - Connect the current supply and close the housing - After switching on the supply voltage: Initialization followed by indication of an unconfigured main value on the display - Call-up of configuration menu by pushing for 2 seconds Menu item Setting Description No value averaging Configuration analog input: Signal mode analog input: 4... 20 ma. Accuracy of indication: 1 decimal. Start value: 0 m³/h (corresponds to 4 ma ). End value: 343 m³/h (corresponds to 20 ma ) Configuration alarm output 1: Activation of alarm output Switching mode: active when exceeding. Switching point: 150 m³/h. Switching hysteresis: 10 m³/h (alarm output declines in case of a decrease below 140 m 3 ).. Response delay: 30 s.. Release delay: 30 s alarm output 2: deactivated Instructions for use MD 10.010 Page 13

Menu item Setting Description Configuration analog output: Activation of analog output Signal mode: 4... 20 ma. Start value: 0 m³/h ( 0 ma). End value: 200 m³/h ( 20 ma) No operation lock After the final menu item the configuration menu is left automatically for changing to the main display - Verification of indication value on display menu Menu item Indication Description. Main display = measuring value sensor (m³/h). Raw value sensor 1 (9.635 ma). Peak-value memory Maximum measuring value of the sensor selected for the main display Deletion of the maximum measuring values of both sensors by using for approx. 5 s. Peak-value memory Minimum measuring value of the sensor selected for the main display Deletion of the minimum measuring values of both sensors by using for approx. 5 s. Switching point alarm output A1 Alarm output A2 switched off Instructions for use MD 10.010 Page 14

Information regarding the display Configuration menu 2s Menu item is only displayed if the respective configuration is selected Averaging of the input signal,.,.,.... s Selection of the input signal: (ma), (V), (ma). Number of decimal places of the measured value:.,.,.,.,.. Start value for the measuring range of the sensor (e.g. 0... 20 m/s).. End value for the measuring range of the sensor (e.g. 0... 20 m/s). Activation of alarm output 1:, Instructions for use MD 10.010 Page 15

Switching behaviour alarm output 1: (Switches as soon as the switching point is exceeded) (Switches if the value falls below the switching point). Switching point alarm output 1:. Hysteresis alarm output 1 (four digits).. Response delay alarm output 1:.......(h.mm.ss).. Release delay alarm output 1:.......(h.mm.ss) Activation of alarm output 2:, Parameterization alarm output 2 identical to parameterization of alarm output 1 (menu items to ) Instructions for use MD 10.010 Page 16

Activation of analog output:, Selecting the signal mode of output signal: (ma), (V), (ma). Start value for display range of analog output. End value for indication range of analog output Key lock:, Modifications in the configuration menu and reset of the peak value memory are locked Modification using the arrow keys even if the key lock is active. Return to the main display Instructions for use MD 10.010 Page 17

Menu overview Menu item Description Indication existing measuring value Indication switching point alarm output 1 Indication switching point alarm output 2 Decimals input signal End value input signal End value output signal Value averaging Operation lock Signal mode input signal Signal mode analog output Indication minimum measuring value Activation analog output Indication maximum measuring value Indication raw value Start value input signal Start value analog output Activation alarm output 1 Switching behaviour alarm output 1 Switching point alarm output 1 Hysteresis alarm output 1 Response delay alarm output 1 Release delay alarm output 1 Activation alarm output 2 Switching behaviour alarm output 2 Switching point alarm output 2 Hysteresis alarm output 2 Response delay alarm output 2 Release delay alarm output 2 Instructions for use MD 10.010 Page 18

7 Service information Eliminating malfunctions The following table lists possible errors (error images). A description of the way to detect errors is given. Furthermore, the possible causes and measures to be taken to eliminate errors are listed. Error image Possible causes Troubleshooting Displays off, analog output to zero Measuring range too large /small Analog measuring value ( ) too large / small Analog signal too large /small Unexpected values at the alarm output Table 4 Supply voltage U B: No U B present U B (DC) has wrong polarity U B too low Measured value display defective Defective configuration of the sensor's measuring range Jumper signal mode analog input Input configuration Output configuration Configuration alarm output Supply voltage: Check if connected correctly to control unit Check the voltage type (DC, AC) Check if there is supply voltage at the terminal (cable break) Check whether the analog measuring value is correct ( ) Configuration of start ( ) and end value ( ) of the sensor's measuring range Set the jumper in accordance with the signal mode Check the input configuration ( ) according to the input signal Check configuration Check configuration Instructions for use MD 10.010 Page 19

8 Technical data Technical data Display Input signal Analog output Relay outputs Accuracy analog output Seven segments LEDs red, height 14,2 mm, 6 digits Additional display: 2 digits, 7 mm 1 x 4 20 ma (R i = 100 Ω) or 0 10 V (R i 10 kω) 1 x 4... 20 ma / 2... 10 V or 0... 20 ma / 0... 10 V (depending on the resistance, galvanically isolated, short-circuit protected) Voltage output: Current output: > 500 Ω < 500 Ω 2 relay changeover contacts (potential-free), max. 250 VAC / 5 A ± 0.2 % of measured value Supply voltage Material no.: 527320 85-250 VAC, 50... 60 Hz Material no.: 528240 Current consumption Current supply of flow sensor Operating temperature Storage/transport temperature Environmental conditions Connection Operating position Ingress protection / Protection class Housing material Weight 18-30 VDC Max. 8 VA 24 VDC ± 15 %, max. 160 ma (short-circuit proof) -20 +60 C -40 +70 C Non-condensing (up to 95 % relative humidity) 14 spring clamp, one conductor 1.5 mm², 4 through-bolt joints any IP65, contact protected Polyamide, glass-fiber reinforced (PA6-GF 15/15), color similar to RAL 7001 approx. 370 g Table 5 Instructions for use MD 10.010 Page 20

9 EC Declaration of conformity Instructions for use MD 10.010 Page 21

Notes Instructions for use MD 10.010 Page 22

Notes Instructions for use MD 10.010 Page 23

SCHMIDT Technology GmbH Feldbergstrasse 1 78112 St. Georgen / Schwarzwald Phone +49 (0)7724 / 899-0 Fax +49 (0)7724 / 899-101 info@schmidttechnology.com www.schmidttechnology.com Instructions for use MD 10.010 Page 24