Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

THE NEW GENERATION VACUUM PUMP SYSTEM SC

Dew point set DS 400

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Constant climate chambers

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Constant climate chamber with humidity

LAUDA PRO bath and circulation thermostats

Environmental simulation chamber for complex alternating climate profiles

DP 300 mobile dew point instrument

Constant climate chamber with ICH-compliant illumination

Environmental Chambers. 2-Door & 3-Door Extra Large Capacity

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Constant climate chambers


Pressure measuring instruments

Food safety can be measured. Check limit values, ensure quality, comply with HACCP with measuring instruments from Testo.

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

LAUDA ECO. Precise, economical, flexible

good reasons for a Memmert

Constant climate chambers

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Constant climate chambers

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

XSD Dry Cabinet. Outstanding performance. The XSD series has an outstanding performance for drying moisture sensitive components and pcb s.

Constant climate chambers

HPLC Column Ovens and Temperature Controllers

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

Healthy. Atmosphere. for Pigs and Poultry. for a

BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

TEMPERATURE SHOCK TEST CHAMBERS

Drying and heating chambers

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Benchtop CO 2 Incubator. the Oasis 6400 series

EC 160 CO 2. Incubator

The right temperature worldwide NEW. LAUDA Integral XT. Professional thermostating for pilot plant and mini-plant purposes. Product information

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Modular Circular Polarimeters

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Helios in a new dimension.

Mercury Vapor Monitor VM-3000

HSD Dry Cabinet

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Model KBWF 240 Growth chambers with light and humidity

Long Term Storage Cabinet

Constant climate chambers

Modular Circular Polarimeters

HSD Dry Cabinet. Outstanding performance

CO₂ incubators. C CB series

Sunrise the beginning of a brand new day

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Drying and heating chambers. Series ED FD FED FP M

Chromatographic Air circulated Refrigerator, two-door TC 603

2016 Catalogue. Bioreactor / Fermentor

BIOMEDICAL REFRIGERATORS

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

ICH110. Climate Chamber. Product specification

SHAKING WATER BATHS ENGLISH

ICH260C. Climate Chamber. Product specification

Overview. rotary microtomes

Innovation in distillation. PAMv2. Automatic Distillation testing. by Orbis BV

LAUDA Additional devices Immersion coolers, through-flow coolers, circulation heat exchangers

Dräger X-dock 5300/6300/6600 Calibration and Bump Testing

ICH750L. Climate Chamber. Product specification

ila ACTIVVE SYSTEM PLATFORM

ULTRASONIC TESTING DEVICE LEAK DETECTION AND CLASSIFICATION STEAM TRAP INSPECTION VALVE INSPECTION TIGHTNESS TESTING DETECTION OF PARTIAL DISCHARGES

SDR Dry Room. Outstanding performance

Helium Leak Detector The clever and modular Solution. Simple Operation. Top Performance.

Rotary Evaporators designed

1,000W (DAP-60K: 100 W per digestion vessel)

Reproducible Climate...

XSD Dry Cabinet

Your competent partner for measuring and services.

STABILITY ICH. ICH Stability Tests

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

FlexLine. Air humidification for industry, commerce, culture and leisure. Steam humidifier. New flexibility in award-winning quality

Refrigerated Incubator Model and Operating Instructions

EasyLog Data Logger Series

VM-3000 Mercury Vapor Monitor

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

Microtherm Heat Stress WBGT

Waterbaths & Oilbaths

Accessories, interfaces, sensors and complete solutions.

FITOCLIMA 600 & 1200 PHARMA

Dräger X-am 7000 Multi-Gas Detection

data logger DL200H DL200D DL200L

Dry ice cleaning with COOLMASTER

KMF Environmental test chamber for constant climate

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Innova M4, M5 and M5-ISo

Humidity Chambers HCP

FITOCLIMA 600 & 1200 STABILITY

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf

Transcription:

Huminator II Precision Humidity Generator ww.testo.in

All advantages at a glance ü Wide temperature and humidity range from 5 C to 50 C and from 5%RH to 95%RH ü New touch display enables a fast and intuitive operation ü Graphical and tabular view as well as storage and evaluation of measured values ü Integrated, easily accessible and replaceable reference sensor, that eliminates the need for an external reference system ü Possibility to program measuring points and procedures individually Easy operation, fast regulation, good stability and homogeneity ü Fast stabilisation time (e.g. 3 min from 35%RH to 80%RH at 25 C) ü Highest measuring stability due to optimal insulation of the chamber and high-end sealing adapter plate ü Large measuring chamber (Ø 160 mm, depth 320 mm) ü No condensation inside the measuring chamber through a regulation along the dew point ü Guaranteed mobility- the compact size and the minimal weight ensure an extremely flexible use of the Huminator II.

Precise humidity calibrations The Huminator II offers the possibility to perform a rapid and easy humidity calibration of measuring instruments, sensors touch display (entry of set points, indication of actual values) and data loggers of all manufacturers. The supplied adapter plate enables a calibration of up to five sensors at a time- without deterioration of the homogeneity. Thus, a high level of efficiency is guaranteed. temperature control set points/ actual values humidity control The timely programming function allows a large degree of automation of calibrations since up to 10 humidity and temperature measuring chamber +%rh humidifier values can be retrieved automatically one after another. The +/- C stabilization time can be selected freely. -%rh With the help of a Peltier- element, the integrated temperature regulation generates and stabilizes temperatures in a range from 5 C to 50 C. Relative humidity can rapidly be produced in a range from 5%RH to 95%RH by a high performance humidi- peltier element (heat exchanger) Testo 6681 reference and control probe (temperature + humidity) drying (e. g. silica gel) fication system. Concept of the removable sensor The Huminator II is equipped with a reference probe which is integrated into the measuring chamber but which is nevertheless easily accessible. It can be exchanged without any problems or removed for recalibration. Your advantages: ü No need for an additional reference measuring instrument ü Only the reference sensor has to be sent in for recalibration. ü Downtimes due to the recalibration can be avoided through the optional purchase of a second reference sensor.

Easy to use via the touch display Due to the touch display, the measuring values are comfortable to control. The clear menu structure enables an intuitive and simple handling. Help texts are additionally at your disposal. With the touch display, the Huminator II can be programmed in a few steps. If required, this process can also be conducted via the USB interface. Furthermore, an acoustic signal helps the user to control the stability and the filling level indicator of the water. Menu overview Tabular view Chart Settings Large measuring chamber The large and extremely solid measuring chamber provides enough space for up to five sensors or several data loggers at the same time. An optimal insulation of the chamber in conjunction with a special sealing adapter plate ensure the stability of the measuring values in a wide range of temperature and humidity.

Stationary use in the calibration lab The Huminator II is designed to carry out fast and precise humidity calibrations. In laboratory use, where fast processing times and continuous operation are of crucial importance, the Huminator is characterized by its outstanding performance and its reliability. On-site use The intelligent use of materials enables a total weight of only 19 kg. This makes the Huminator II mobile and flexible to use. The water can be drained automatically with the help of a display command. From this it follows, that the Huminator II is quickly ready for transportation. The optimal protection is given by an optionally available transport trolley, promising excellent handling during the on-site use.

Maintenance & Service The integrated reference enables a fast recalibration. Furthermore you benefit from a significant cost reduction by saving the external reference. Due to the service access on the upper side of the housing, the drying cartridge can easily be replaced at any time. You only need distilled water for the Huminators operation, no further operating materials are necessary. Besides a power supply, no further external connection is required. Directly accessible help texts are at your disposal on the the touch screen. In addition, an electronic instruction manual is provided. Order information Huminator II 0519.0900 Accessory Price on request Transport trolley DAkkS-Calibration 2. Reference Testo industrial services GmbH Gewerbestraße 3 79199 Kirchzarten Germany www.testotis.com info@testotis.de 0519.0899 On request 0555.6610 Transport trolley

Flexible, precise, mobile General data Technical Data Specifications Measuring and control range Stability Probe accuracy at 25 C 5 to 50 C 5... 95 %RH ± 0.02 C (at 25 C; 50 %RH) ± 0.15 C (0.27 F) with PT1000 Class AA ± 0,3 %RH (10... 80 %RH bei 10... 40 C) ± 0,5 %RH (rem. measuring range) ± (1,0 %RH + 0,007 x meas. value) für 0... 90 %RH Homogeneity ± 0.2 C ± 0,5 %RH Stabilization time 3 min (from 35 to 80 %RH at 25 C) Ambient conditions 20 ± 5 C Typical total measuring uncertainty of the calibration (k=2) ± 0.2 C (10 to 85 %RH at 25 C) ± 0.5 C (rem. measuring range) ± 1.5 %RH (10 to 85 %RH at 25 C) ± 2.0 %RH (rem. measuring range) Display Touchscreen Number of probe slots 5 Interfaces USB, LAN Power consumption (typical) 30 W to 250 W, max: 500 W AC input voltage/ 110 V to 230 V ±10 % 50/60 Hz -frequency Tank volume Tank with a capacity of 200 ml Water level indicator Completely automatically with graphic display Display of measuring data Control Stabilization signal Dimensions (DxWxH) Size of the measuring chamber Volume oft he measuring chamber Weight Scope of delivery Drying cartridge Operating material Other certifications In graphic and tabular form Manually or automatically programmable visually and acoustically 451 mm x 448 mm x 266 mm 482 mm x 448 mm x 290 mm (incl. attachements) Diameter: 160 mm Depth: 320 mm appr. 4.2 liters (inlet: 154 mm, Depth to cooling element: 230 mm) 19 kg Dry granulates with a change of color Depending on the humidity content Plugs for probes (17 pieces) Power cord ISO calibration certificate CE Approval BGV A3 approved

Dimension drawing 448 (depth: 451) 0980.5194/PC/len/03.2009 266 CHAMBER Huminator precision humidity generator by Testo Industrial Services 5-95 % RH 5-50 C Power Touch-Display Measuring chamber Ø 160 mm