Instruction Manual for FORMALDEHYDE GAS DETECTOR MODEL FP-30/FP-40

Similar documents
IMR IX176 Portable Gas Detector User Manual

INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR

IMR EX610. Portable Gas Detector. Operation Manual

Portable Gas Detector Instruction Manual

E1000 Portable gas detector

Portable Gas Leak Detector SP-220 Series TYPE F Operating Manual

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

KANE-ALERT-CO 2 Monitor with Temperature

testo Leakage detector for gas Instruction manual

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

EVac II Programmable Digital Vacuum Gauge

BST-MG07 Multi-gas Detecting Alarm Manual Instruction

Using the QRAE Plus personal multigas monitor

Intelligent Super Toilet AFC230 User Instruction Manual

This instruction manual explains the use of three models listed on the left.

TIF9055 Programmable. Owner s Manual Manual del Propietario Manuel du propriétaire Benutzerhandbuch Manuale del proprietario

Fire Command Keypad. XR5 User s Guide

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

Enteral Pump Instructions for Use To Assemble When the low

Operation Guide 3408

Dehumidifier. Instruction Manual. Model DH-320/A

Operation Guide 5510

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Wireless Remote Controller Kit

HIn3550 Magnetic Field Monitor User's Manual

Portable Air Conditioner Instruction Manual

Focus 4010\ Focus 4010 HT porcelain firing furnace

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

Installation and Operating Manual

Chapter 5 Inspection and maintenance

Operate the Mutli-Gas Monitor PID

MD-MINI Dry Bath. Instruction Manual

H-10PM. Refrigerant Leak Detector

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS

DYGIZONE GJD910 Lighting Controller & Enunciator

MODEL OX-07 Type A INSTRUCTION MANUAL FOR RIKEN PORTABLE OXYGEN MONITOR PT0E-0860

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

Suits all KPF849 models

Portable Oxygen Monitor OX-07. (Type A) Operating Manual

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

HV2R ROTARY LASER INSTRUCTION MANUAL

Using the MiniRAE 2000 & ppbrae PID

Safe Operation Manual. Honeywell IQ Force Gas Detector

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

THERMAX Efficiency Monitor

Greenleaf 100 Toilet Macerator Waste Pump Instruction Manual

INSTALLATION AND OPERATION INSTRUCTIONS FOR

CDL 210. Operating manual. CO2 Logger. Best.-Nr

AIR CONDITIONER OPERATING MANUAL. Duct type. Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE. PART No.

Portable Gas Leak Detector SP-220 Series TYPE FUM TYPE SC Operating Manual

System Installation. multi-zone heating

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

Chapter 8 Troubleshooting

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Chapter 8 Troubleshooting

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

H1R Red Rotary Laser INSTRUCTION MANUAL

Forehead Thermometer Instruction Manual

Operating Guide. English Version 3.3

ASG EZ-9000GR Tape Dispenser User Manual ASG #66136

Ammonia Leak Detector Manual

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

OWNER S GUIDE TYPE A TYPE C TYPE B TYPE E TYPE F TYPE D COOL FAN OFF. CA Series << FAN SPEED COOL FAN AUTO SLEEP TIMER FAN SPEED

SC-01 Operator s Manual

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

Operating Manual (PT0-119)

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

WBGT Heat Stress Meter

High Wall Split Air Conditioners 53QHCT KHCT

testo Leakage detector for refrigerants Bedienungsanleitung Instruction manual

INSTALLATION AND OPERATION INSTRUCTIONS FOR ZERO CLEARANCE AND INSERT UNITS

Interscan Corporation. Instruction Manual Series Compact Portable Analyzer

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

Automatic Phone-Out Home Monitoring Systems

OWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES)

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

Security System. User s Guide for the Text Command Center

MANUAL FOR MJK LIQUID SAMPLER 780

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

MODEL: SP2nd (Portable Single Gas Detector) Operating Manual

CL3 HYBRID MULTI-LINE LASER INSTRUCTION MANUAL

Carbon Dioxide Sample-Draw Detector Operator s Manual

BST-MG01 Single Gas Detecting Alarm Manual Instruction

SD Storage Cabinet. Outstanding performance

Instructions for set-up, use and cleaning

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

INSTALLATION AND OPERATION INSTRUCTIONS FOR SAFETY INFORMATION WARNING

Pioneer-R16 Gas Monitor Operator s Manual

OPERATION MANUAL. Wireless Remote Controller Kit

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

Security System. User Guide for the LED Command Center

KEY OPERATOR STUDY GUIDE

WIRING DIAGRAM. This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

15,000 BTU Portable Air Conditioner

INSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems

Transcription:

Instruction Manual for FORMALDEHYDE GAS DETECTOR MODEL FP-30/FP-40 This instrument is sold and serviced by RKI Instruments, Union City, CA For questions, parts, or service please contact RKI at (800) 754-5165. Please read and understand this instruction manual before operating this instrument. Part Number: 71-0085RK Revision: P3 Released: 8/27/03

Table of Contents 1.1 Start-up Operation 2 1.2 Installation of the Detection TAB 3 1.3 Detection Method 4 1.4 High Density Gas Detection 4 1.5 Memory of Stored Detection Results 4 1.6 Battery Voltage Check 7 1.7 Preliminary Sample-Draw 7 1.8 Purge Cycle 8 1.9 Completion of Detection 8 2.1 Storage of Detection TAB 9 2.2 Handling of Detection TAB 9 4.1 Battery Replacement 12 4.2 Daily Check / Regular Check 12 4.3 Replacement of parts 12 4.4 Storage and Treatment After Long Term Storage 12 13 6 6.1 Specifications 14 6.2 Accessories 14 6.3 Spare Parts List 14 7 15 1

1 OPERATION 1.1 Start-Up Operation Press ON/OFF switch for 2 seconds to turn instrument on and start warm-up and self-diagnosis. The program and instrument display function one of the following two ways: If the detection TAB is not installed before start-up: Press ON/OFF switch for 2 seconds Approx 5 sec BATT E--------l------F Shows the battery capacity STAND BY OK Standby Condition Approx 5 sec SET TAB Waiting for TAB to be installed and selected If the detection TAB is installed before start-up Press ON/OFF switch for 2 seconds BATT----------l----F Shows the battery capacity Approx 5 sec SELF-DIAGNOSIS Self-diagnosis : Sensor check Approx 5 sec STAND BY OK Standby Condition Approx 5 sec SELECT TAB No Select the detection TAB for desired range using up/down button. 2

1.2 Installation of Detection Tab The detection TAB comes packaged in a sealed foil wrapper. Remove it from the wrapper. The detection surface of the TAB is protected by a plastic cover that fits over the TAB. Remove this cover. The detection TAB must only be handled by its edges or backside. Do not touch the indented center section of the TAB. 1. Open the detection TAB cover. Lift up this way. Detection TAB cover Instrument (Side view) 2. Place the TAB into the slot under the cover, indented face down, and then close the cover slowly. Close the cover. Detection TAB Instrument (Side view) 3. Press the center of detection TAB cover with finger to assure proper TAB seating. When closing the detection TAB cover, close it slowly to avoid pinching finger. Do not allow the lid to slam shut since that may cause damage to the instrument. When installing the detection TAB, do not allow water drops or dust to get in the TAB port area. 3

1.3 Detection Method Gas detection Detection waiting condition The instrument waits in this mode until the detection TAB is installed. Installation of the detection TAB Install the detection TAB. Selection of the detection range Select the detection range by pressing up/down keys. Detection starts Press START switch to start the pump and start the detection cycle. Cycle is either 15 minutes or 30 minutes (as selected). Display of detection result After the detection cycle is completed, the average gas reading during the detection cycle is shown as the detection result. Display of memory number The number recorded for this reading in the memory is displayed. Completion of detection The gas reading and message will alternately be shown until the used detection tab is removed. Buzzer sounds every one second until used tab is removed. Display example SET 1 Detection waiting condition 2 Install the detection TAB SELECT TAB No 008 : HCHO START 2 Select the detection TAB (time/range selection) using the up/down keys. 008 : HCHO PUSH 008 : HCHO 1800 4 Start Counting down the detection time. (Sec.) 008 : HCHO 0.100 5 Display of detection result MO5 REGISTERED 6 Memory number display REMOVE TAB beep beep 7 Completion of detection 008 : HCHO 0.100 4

NOTE Only one type of detection TAB is used in the FP-30 & FP-40, but the TAB may be used for three different detection ranges. For the FP-30, select the TAB No. according to the desired detection range. The FP-40 can only be used for one detection range. Detection range Measuring time TAB No. 0-0.4 ppm (FP-30) 30 min. 008 0 1.0 ppm (FP-30 15 min. 009 0-0.6 ppm (FP-40) 3 min 010 Do not remove tab during detection. If TAB is removed during detection, the detection is interrupted, and that cycle cannot be restarted with a new TAB. The error message TAB is displayed. The old TAB must be discarded and replaced with a new one before a new cycle is started. When the detection range is changed for a new cycle, be sure to exhaust the inside gas by pre-sample drawing from the instrument (see Section 1.7 Preliminary Sample Draw Mode) to flush out any residual gas concentrations inside the unit. If high-density gas remains inside the FP- 30 then it may affect the next gas detection cycle. Do not suck water or oil into the instrument since this will cause pump and instrument damage. When detecting gas, confirm that the pump is working by listening to the humming sound of the pump or confirming that the pump is sucking. If the pump is not sucking, no gas detection will occur. Do not block the gas outlet, or else an incorrect gas reading may result. 5

1.4 High Density Gas Detection If high-density gas is detected, the instrument and any sample hose must be flushed out with fresh air before installing a new detection tablet. If a new detection tab is installed immediately without flushing the instrument (and sample hose) out with fresh air, the wrong answer will occur since detection will start immediately when the new tab in installed. (SEE PRELIMINARY SAMPLE DRAW, STEP 1.7) 1.5 Memory of Stored Gas Detection Results 1.5.1 Checking Stored Data The past detection results can be displayed by pressing DATA switch when in the detection waiting condition or detection finished condition. The detection results will be stored into the instrument memory (up to 99 readings maximum). The memory can be retrieved by using the UP and DOWN keys. When power is off, the memory is retained. To return to the detection waiting condition or detection finished condition, press DATA switch again. When the DATA switch is pressed, the most recent record is displayed. M05 : HCHO 0.100 The detection result memory can store only the past 99 readings. If the memory is full, the display will say: DATA FULL For deletion of measuring results stored in memory, see the next page. If there is no stored data, the display will say: DATA EMPTY 6

1.5.2 Deleting the Memory of Stored Detection Results To delete the memory: While in the data display screen described above in 1.5.1, press the START + DATA switches simultaneously. The message to delete the stored detection results is displayed. Then, when START switch is pressed, all the stored detection results are deleted. If DATA switch is pressed instead, the instrument will return to the previous condition without deleting the data. DELETE START Display every 1 sec. DELETE PUSH Display every 4 sec. STORE DATA Display every 1 sec. STORE PUSH It is impossible to delete an individual detection result. All detection results are deleted simultaneously, and once deleted they are not recoverable. 1.6 Battery Voltage Check By pressing DATA switch for 3 sec while in detection waiting condition or detection finished mode, the current battery voltage can be checked. If 20 seconds elapses without any switch being pressed while in the battery voltage check screen, the instrument will return to the state it was in, either detection standby condition or detection finished mode. To return to the detection waiting or detection finished mode, press DATA switch again. BATT E----------l------F 1.7 Preliminary Sample Draw Mode When detection gas mode is changed, or if a high gas concentration was last detected with the instrument, it is possible the next gas detection test will be influenced by high-density gas remaining inside the instrument. To prevent this, it is necessary to flush the instrument using the preliminary sample-drawing mode. 7

Preliminary sample drawing method With detection TAB removed, press START switch. Preliminary sample drawing is made for about 5 sec to flush out the previous sample, and the following message is displayed until completion. Previous sample drawing Preliminary sample drawing must be done in fresh air, or in the air of the room you will check next. 1.8 Purge Cycle When sample-drawing an adsorptive gas continuously, there is the possibility the gas will be adsorbed onto the inside of the tubing, especially if a high concentration of gas is encountered. If a high concentration of gas is encountered, the system must be purged in known fresh air before taking a reading. After purge, the gas detection cycle will start automatically. Purging method Mount the detection TAB, select the purge cycle by using UP and DOWN keys. A used TAB may be used for the purge cycle. PURGE PURGE S T A R T P U S H When START switch is pressed, the purging starts. for 10 minutes PURGE 600 Count down 600 sec. When 10 min (600 sec.) passes, the purge cycle is finished and the unit is ready to start the next gas detection cycle. REMOVE TAB 1.9 Completion of Detection HOW TO TURN INSTRUMENT POWER OFF To turn instrument off, press and hold ON/OFF switch for about 3 sec. When pressing ON/OFF switch, the buzzer sounds about 9 times. Also, if 5 minutes passes without any button being pressed, or when 5 minutes has elapsed since the last operation, the power will shut off automatically. 8

2 ABOUT THE DETECTION TAB The Gas Detection Tablet is a unique detection method developed by our company. The tablet contains a paper impregnated with special chemicals that will darken if exposed to a specific gas. Proper storage of the tablet is critical. If tablet is not stored correctly, the detection results will not be accurate. 2.1 Storage of Detection TAB Detection TAB must be used within the storage period indicated on the package. Use of tablets beyond their expiration date can result in incorrect readings. Leave detection TAB in its package until ready for use. Once a tablet is removed from its packet, it will begin drying out, and also it may respond to gas in the local environment causing error if used for any actual test. Follow the storage instructions on the detection TAB package. Detection tabs must be stored in a refrigerator for longest life. If detection tab is removed from its package and not used right away, it must be discarded. It will give an incorrect reading if used later. Prolonged exposure to air or background gas will dry out the tablet or cause it to become discolored, either of which will cause an incorrect reading. 2.2 Handling of Detection TAB Do not touch the test paper of the detection TAB. Test paper (White) Ring (Black) TAB No & Gas name etc Do not touch the test paper with your finger; this will cause an incorrect reading. 9

Always use a new detection TAB for readings For each gas test, be sure to use new detection TAB. TABS are intended for one time use only, and should not be opened until immediately before you intend to use them. If an already used TAB is attempted to be used, an error message TAB may be shown. But, even if the error message is not displayed, the detection result will not be correct if an old TAB is used. Use TAB immediately after removing from package. After unpacking the detection TAB, it is subject to gas response and dust, which discolors the TAB due to response to the measured. To maintain accuracy, start measurement immediately after unpacking. _ Check that the number of the detection TAB corresponds to the TAB number of displayed on FP-30 during the Start Measurement display. If the TAB used is not the same TAB number the instrument believes you are using, the reading will not be correct. 10

3 SELF DIAGNOSIS FUNCTION A Self-diagnosis function is provided with this instrument. Each self-diagnosis mode has a unique alarm, display, and buzzer sound. Types of self-diagnosis and alarm pattern Self diagnosis Buzzer Display Power on During gas detection Low battery voltage Continuous REPLACE BATTERY System error No sound SYSTEM ERROR Sensor failure Continuous FAIL Low battery precaution No sound Flickering B at left Lower battery voltage Continuous REPLACE BATTERY Failure of pump connection Continuous PUMP FAILURE TAB detachment No sound RESET TAB Defective TAB Continuous TAB FAILURE and REPLACE TAB 11

4 MAINTENANCE 4.1 Battery Replacement When replacing batteries, replace all 4 batteries at the same time. Turn power off. Remove the carrying case from instrument. Press the battery cover slightly and slide it off. Remove all 4 batteries and install the new batteries. Take care to use correct polarity and battery type. After replacing batteries, replace cover and carrying case. 4.2 Daily Check/Regular Check Daily check Checking switches, display and body for any physical damage. Pump suction check. Is pump running sound normal? Check battery voltage. Sensor check: Instrument performs a sensor check duding warm up whenever first turned on. 4.3 Replacement of Parts The following parts have a limited life and it is recommended that they be replaced regularly. Pump : Sensor : About 1 year (field replaceable) About 5 years (factory replaceable only. Requires special tools and calibration) 4.4 Storage and Treatment After Long Term Storage Store in a cool dry place and out of direct sunlight. If storing for a long period, remove batteries before storage. 12

5 TROUBLE SHOOTING This trouble-shooting guide cannot cover all possible malfunctions. The most likely problems and causes are listed below. Symptom (Message) Cause Treatment Low battery (REPLACE BATTERY) Battery voltage is low. Replace Batteries Sensor failure (FAIL) Pump failure (PUMP FAILURE) System error of instrument (SYSTEM ERROR) Detachment of TAB (RESET TAB) Failure of TAB. (TAB FAILURE) (REPLACE TAB) Power will not turn on. Excessive shock such as dropping, or extensive use for a long time. Remove the detection TAB during sensor check. Excessive shock such as dropping, or extensive use for a long time. Possible influence by high EMI or RFI signal, or other electrical problem. Remove TAB. The initial condition of TAB is not normal. Batteries need replacement or no batteries installed. Battery polarity is wrong. Turn on power again and repeat the sensor check. If it does not recover, return to factory for repair. Replace TAB and turn on the power. Re-check the sensor. Turn power on again. If not recovered, replace pump or return unit to factory for repair. Turn power on again. If not recovered, return to factory for repair. Remove /replace tab after gas detection cycle is complete. Use new TAB. Replace or install batteries correctly. Pump not working. Sample cannot be drawn On/Off switch not held long enough. The battery capacity is too low. The sampling hose is disconnected or clogged. Press switch for approx. 2 sec. (Until instrument turns on) Replace batteries and try again. Check the connection of sampling hose. Check for clogged hose. 13

6 SPECIFICATIONS 6.1 Specifications Model FP-30, FP-40 Detection principle Photoelectric photometry method Display method Digital display by LCD. Sampling method Sample-drawing by pump Memory function 99 points logged. (Automatic recording after detection) Ambient temp -10 to +40 C, 90% RH (Non-condensing) Power source AA size Dry battery, 4 ea. Continuous duty Approx. 12 hours (with Alkaline battery, no alarm or illumination and at 20 C Regulatory NOT explosion proof or intrinsically safe. Dimensions Approx. 85(W) 190(H) 40(D) mm (not including instrument protrusions) Weight Approx. 550g (Including instrument and batteries) 6.2 Accessories Standard accessories: Carrying case AA size battery 1 pack of 20 tablets Instruction manual Optional accessories_ Additional detection tablets (20 / pack) Software for data logger Exclusive cable for data logger 6.3 Spare Parts List Part Number Description 65-TAB-008 Detection TAB, type 008/009/010 71-0085RK Operator s Manual (this document) 14

6.4 7 DETECTION PRINCIPLE The Gas detection TAB test paper is treated with special chemicals and an illuminating agent. When gas is blown onto the TAB paper face, the paper emits illumination by chemical reaction, and this causes the paper to change color. The amount of color change is determined by the level of formaldehyde exposure, and the time of exposure. For example, when formaldehyde (HCHO) contacts the paper, chemicals impregnated into the paper combine with HCHO to form compounds, and these compounds change the paper from white to yellow color. The instrument creates a light beam that reflects off the test paper at the end of the detection cycle. The intensity of the light beam is affected by the color or darkness of the detection TAB paper, and this intensity is measured by a light sensor. The level of light intensity measured is correlated (from an exposure curve stored in the instrument) to a particular level of Formaldehyde exposure to the tab. This concentration is then displayed at the end of the detection cycle. Detection TAB Light (LED) Chamber GAS IN GAS OUT Photo sensor (Photo diode) 15