Statistical Testing of Electric Meters

Similar documents
Quality Control Acceptance Sampling Systems

API MANUAL OF PETROLEUM MEASUREMENT STANDARDS

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

ISO/TS TECHNICAL SPECIFICATION

SolderSleeve Insulated Electrical Termination Devices

Application Note. Application Note for BAYEX

Standard ECMA th Edition - December Declared Noise Emission Values of Information Technology and Telecommunications Equipment

Alarms Updated 03/26/2018

POINT HELIDECK LIGHTS PRL-LSM LED LOW SURFACE MOUNT LIGHT

POINT ROLLOVER LIGHTS PRL LED HELIDECK SEMIFLUSH LIGHT

UNITED STATES DEPARTMENT OF AGRICULTURE FOREST SERVICE SPECIFICATION FOR LED HEADLAMP, FIREFIGHTER

FORM ACCL-PC1 ACCL WITNESS TEST PROCEDURE AND CHECKLIST

NEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY

INTERNATIONAL STANDARD

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

Article 14. LIGHTING REGULATIONS

ORDINANCE NO. _ THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

Changes to NFPA 101A 2013 Edition for Health Care Facilities

Thermostat Catalog 2004

POINT ROLLOVER LIGHTS PRL LED HELIPORT INSET LIGHT

Test Report. Appliance EMF Testing

Zoning Ordinance Article 3

Jun08 Rev A

Can You Hear Me Now?

Can You Hear Me Now?

Failure Modes, Effects and Diagnostic Analysis

American National Standard for Electrical Lamp Bases Specifications for Bases (Caps) for Electric Lamps

ISO/TS TECHNICAL SPECIFICATION

H gh-p led Combust ble Storage. Application Guide 2009 Edition

Sec Development design approval and procedures.

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

Part 2-55: Medical electrical equipment. Particular requirements for the basic safety and essential performance of respiratory gas monitors

RTD TEMPERATURE SENSING SYSTEM

SMALL MOTOR CONTROLLERS

CERTIFICATE of Product Conformity (QAL1 )

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa

This document is a preview generated by EVS

Chapter 2 Study Questions and Research Methods

ALARM RESPONSE POLICY

A novel test method for predicting crushing elasticity in medium fluting with higher relevance than for instance currently used methods like CMT

FIRE AND LIFE SAFETY EDUCATOR II NFPA 1035, Chapter 5, 2015 Edition

Emissioni convogliate in atmosfera: Sistemi di monitoraggio in continuo delle emissioni SME

Residential Air Leakage (Blower Door) Testing for Florida Code Compliance

Electrical Hazards and NFPA-70E: Protecting Your Employees

Daikin VRV Systems Plugin VE2012 User Guide

January 21, Re: NOPR to Revise Water Heater Test Procedures. Docket No. EERE 2011 BT-TP Dear Ms. Edwards,

DEPARTMENT OF PUBLIC SAFETY DIVISION OF FIRE PREVENTION AND CONTROL

HALON FLIGHTLINE EXTINGUISHER EVALUATION: DATA SUPPORTING STANDARD DEVELOPMENT [INCLUDES NOVEMBER 2007 ADDENDUM]

The Current (2017) State of the Art for Air Leakage in Ductwork

Supplier Handbook. InSinkErator st Street Racine, WI

Narrative Reports As Regulated by 780 CMR, Section 903.0

Pilz Safety Lockout System (PSLS)

Research on Decision Tree Application in Data of Fire Alarm Receipt and Disposal

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights.

Information Bulletin

FRP HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL FRP.IOM.R1

ISO/TR TECHNICAL REPORT. Fire-safety engineering Technical information on methods for evaluating behaviour and movement of people

American National Standard for Roadway and Area Lighting Equipment Elliptically Shaped, Enclosed Side-Mounted Luminaires

ILNAS-EN 61649:2008. Weibull analysis. Analyse de Weibull. Weibull-Analyse

American National Standard for Roadway and Area Lighting Equipment Induction Lighting

CAN/ULC-S1001, INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION & LIFE SAFETY SYSTEMS Simon Crosby, LEL, CET, CFPS October 21, 2015

Understanding total measurement uncertainty in power meters and detectors

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

This document is a preview generated by EVS


Operational Fertilization Monitoring An alternative monitoring protocol

MIL-PRF Hybrid QML Status SPWG 2017

TESTS OF ADSIL COATING

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

SECTION (16460) - LOW-VOLTAGE TRANSFORMERS

NEMA Standards Publication ICS (R 2007) Adjustable Speed Electrical Power Drive Systems

ADDENDUM NO. 1 COPPER COMMUNICATIONS CABLE AND VOICE AND DATA EQUIPMENT MONITORING, TESTING, AND REPAIR DEPARTMENT OF WATER RESOURCES

ISO INTERNATIONAL STANDARD. Fire-resistance tests Elements of building construction Part 1: General requirements

ISO INTERNATIONAL STANDARD

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update

ANSI/NETA Standards Update

ISO INTERNATIONAL STANDARD

Remote Relay Module (RRM)

Title 24, Part 6 Certification of Economizer Fault Detection and Diagnostics (FDD)

Examples of Heat Pumps in DEAP

Water Resources and Policy Initiatives CSU Campus Water Use Calculations Standard Operating Procedures February 26, 2016

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

Massachusetts Program Administrators and Energy Efficiency Advisory Council

The MCD-111 AUTOKLAW Microprocessor Controller Version 1.00 User s Manual

NATIONAL TECHNICAL SYSTEMS

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

MGC Dock User s Manual

Acknowledgement: Ralph Prahl, Prahl & Associates, contributed critical review and analysis

NFPA Updates (c) 2015 SSR, Inc. All rights reserved Florida AHCA Conf

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

ISO 7779 INTERNATIONAL STANDARD. Acoustics Measurement of airborne noise emitted by information technology and telecommunications equipment

C-NRPP Quality Assurance Guidance for Radon Test Devices

SECTION SECURITY TESTING AND COMMISSIONING

Introduction to Docking Technology

American National Standard

Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011

Notes: 1 Square = 1 Foot

GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies

Transcription:

Statistical Testing of Electric Meters A Presentation for the North Carolina Meter School & Conference June 25, 2003 Presented by Peter Yarger, P.E. Project Manager, Advent Design Corp. 1

What is Statistical Testing? Statistical testing is the testing of a population or group for specific characteristics or parameters using a valid statistically-derived sampling plan. 2

Features of a Statistical Sampling/Testing Plan Homogeneous Population(s) Sample(s) of a Suitable Size for the Plan Random Sample Selection of Items to Be Tested Expectation that the Group or Population Being Tested Fits the Statistical Model 3

Features of a Statistical Sampling/Testing Plan: Homogeneous Population(s) The groups or populations being sampled and tested are made up of the same or similar items, items which operate in the same way and were made in the same manner. For electric meters, this has traditionally been interpreted as being meters of a specific meter type from a manufacturer (i.e. AB1, J5S, MX, etc.). 4

Features of a Statistical Sampling/Testing Plan: Suitably Sized Samples The sample size for each group must be large enough to provide a statistically valid sample for the group s population. The larger the group s population, then the larger the sample will be up to a certain point. 5

Features of a Statistical Sampling/Testing Plan: Random Sample Selection Every item within the group or population has an equal chance of being selected as part of the sample for testing. Random sample selection is critical to providing for a statistically valid sample. 6

Features of a Statistical Sampling/Testing Plan: Population Fits the Statistical Model (Part 1) The statistical model being used for the sampling/ testing plan needs to match the actual distribution of the population. In most circumstances, one is looking at a normal or Gaussian distribution (i.e. a Bell curve). This can be checked using a histogram plot or a correlation analysis. 7

Features of a Statistical Sampling/Testing Plan: Population Fits the Statistical Model (Part 2) For mechanical and electromechanical meters, a normal distribution fits the actual data fairly well. For electronic or solid-state meters, there is some question due to the failure modes of these meters. These meter types are fairly recent designs, and not enough data has been seen yet to verify a normal distribution. 8

Why Use a Statistical Sampling/Testing Plan? Focuses testing on the proper meters. Minimizes number of meters to be tested; usually requires less than 30% of what a periodic testing plan requires. Can provide data and analysis tools for use in understanding what is happening with meters installed in the field or for use in the purchasing of new meters. 9

What Statistical Sampling/Testing Plan to Use? Pre-defined statistical plans Plans defined by state regulations Create your own 10

ANSI C12.1-2001 Code for Electricity Metering Guidance Paragraph 5.1.4.3.3 Statistical sampling plan The statistical sampling plan used shall conform to accepted principles of statistical sampling based on either variables or attributes methods. Meters shall be divided into homogeneous groups, such as manufacturer and manufacturer s type. The groups may be further divided into subdivision within the manufacturer s type by major design modifications. NOTE - Examples of statistical sampling plans can be found in ANSI/ASQC Z1.9, the ANSI version of MIL-STD-414 and ANSI/ASQC Z1.4, the ANSI version of MIL-STD-105. 11

ANSI/ASQC Z1.4-1993 Sampling Procedures and Tables for Inspection by Attributes Based on MIL-STD-105 Uses attributes (pass/fail, yes/no, etc.) as the basis for its analysis Variety of special and general inspection levels Various sampling plans (single, double, & multiple) Wide range of Acceptable Quality Levels (AQL s) 12

Inspection Levels: ANSI/ASQC Z1.4 Inspection Levels Special Levels S-1 through S-4 Used for quick sampling and testing in certain circumstances Small sample sizes Not used for meter testing General Inspection Levels I, II, and III Level I is reduced inspection Level II is normal inspection (This level is the one that is normally used.) Level III is tightened inspection Inspection level is used in conjunction with group size in Table I to determine sample size code letters. 13

ANSI/ASQC Z1.4 - Table I 14

ANSI/ASQC Z1.4 - Table II-A 15

ANSI/ASQC Z1.4 - Table II-B 16

ANSI/ASQC Z1.4 - Table II-C 17

ANSI/ASQC Z1.4 - Table III-A 18

ANSI/ASQC Z1.4 - Table IV-A (portion) 19

ANSI/ASQC Z1.4 Acceptable Quality Level (AQL s) AQL is the maximum percent nonconforming (or maximum number of nonconformities per hundred units) that, for purposes of sampling inspection, can be considered satisfactory as a process average. For ANSI/ASQC Z1.4, AQL s vary from 0.010 to 1000 with 26 pre-defined AQL values. For use with electric meter testing, either in-service testing or receipt inspection, AQL s of 0.25 to 2.5 are normally utilized. 20

ANSI/ASQC Z1.4 Applications for Electric Meter Testing Receipt inspection for new meters Monitoring of nonperformance-related parameters (broken glass, damaged base, etc.) for in-service testing or receipt inspection Simple in-service testing plans 21

ANSI/ASQC Z1.9-1993 Sampling Procedures and Tables for Inspection by Variables for Percent Nonconforming Based on MIL-STD-414 Use variables (a measured parameter or characteristic) as the basis for its analysis. This is normally weighted average for electric meters. Variety of special and general inspection levels Selection of Acceptable Quality Levels (AQL s) 22

ANSI/ASQC Z1.9-1993 Sampling Procedures and Tables for Inspection by Variables for Percent Nonconforming Various methods (Variability Unknown - Standard Deviation Method, Variability Unknown - Range Method, and Variability Known Method) All methods can be used with single or double specification limits. For electric meters, the Variability Unknown - Standard Deviation Method with Double Specification Limits is normally used. 23

Inspection Levels: ANSI/ASQC Z1.9 Inspection Levels Special Levels S-3 and S-4 Used for quick sampling and testing in certain circumstances Small sample sizes Not used for meter testing General Inspection Levels I, II, and III Level I is reduced inspection Level II is normal inspection (This level is the one that is normally used.) Level III is tightened inspection Inspection level is used in conjunction with group size in Table A-2 to determine sample size code letters. 24

ANSI/ASQC Z1.9 - Table A-2 25

ANSI/ASQC Z1.9 - Table B-3 26

ANSI/ASQC Z1.9 - Table B-4 27

ANSI/ASQC Z1.9 Calculations For Standard Deviation Method Determine the mean and the standard deviation for the sample results. Determine Quality Indexes Qu = (Upper Limit - mean)/standard deviation Ql = (mean - Lower Limit)/standard deviation Upper Limit is normally 102, and Lower Limit is normally 98. Use Qu and Ql to determine estimate of percent nonconformance above the Upper Limit (Pu) and below the Lower Limit (Pl) using Table B-5. 28

ANSI/ASQC Z1.9 - Table B-5 (portion) 29

ANSI/ASQC Z1.9 Calculations For Standard Deviation Method With the values of Pu and Pl determined from Table B-5 using Qu and Ql, estimated percent nonconformance equals to Pu plus Pl. (% ncf = Pu + Pl) Acceptance is based on whether the estimated percent nonconformance is below the allowed percent nonconformance given in Table B-3. 30

ANSI/ASQC Z1.9 Acceptable Quality Level (AQL s) AQL is the maximum percent nonconforming that, for purposes of sampling inspection, can be considered satisfactory as a process average. For ANSI/ASQC Z1.9, AQL s vary from 0.10 to 10.00 with 11 pre-defined AQL values. For use with electric meter testing, either in-service testing or receipt inspection, AQL s of 0.25 to 2.50 are normally utilized. 31

ANSI/ASQC Z1.9 Applications for Electric Meter Testing In-service testing of meters Receipt inspection of new meters 32

ANSI/ASQC Z1.4 & ANSI/ASQC Z1.9 ANSI/ASQC Z1.4: Comparison Simpler and quicker analysis Analysis can be done manually Limited data on actual meter performance ANSI/ASQC Z1.9: Much more complicated analysis Best done with automated data gathering and analysis Provides good feedback on meter performance Much smaller sample sizes 33

State Regulation Requirements - North Carolina Periodic Testing of In-Service Meters: Commutating type and mercury type two and three wire meters - every 12 or 18 months depending Ampere rating Single-phase induction meters - every 96 months Self-contained polyphase meters - every 72 months Transformer-rated polyphase meters - every 48 months 34

State Regulation Requirements - North Carolina A statistical sampling program for self-contained singlephase watt-hour meters may be used by any utility in lieu of the periodic testing program specified above provided the utility files with the Commission a statistical sampling plan which is approved by the Commission. (Rule R8-13, Para. (9)) Plan must meet nine criteria listed in Rule R8-13 which are obviously based in part on ANSI/ASQC Z1.4 and ANSI/ASQC Z1.9. 35

State Regulation Requirements - South Carolina Periodic Testing of In-Service Meters: Transformer-rated polyphase meters - every 4 years Transformer-rated single-phase meters - every 8 years Self-contained polyphase meters - every 6 years Self-contained single-phase meters - every 8 years Single-phase meters may be tested and calibrated in accordance with Sample Meter Testing Plans approved by the Commission. (Chapter 103, Article 3, Subarticle 6, Para. 103-370.2.d) 36

State Regulation Requirements - Virginia Unable to locate regulations for in-service meter testing. Submetering rules have specific requirements: Each owner shall have a testing program for the primary purpose of which is to maintain an acceptable degree of accuracy during the service life of the equipment. All submetering equipment shall be tested in accordance with the provisions of the latest edition of ANSI C12 or ANSI B109. (20VAC5-305-70 Periodic test and checks) 37

Advent Design Corporation Canal St. & Jefferson Avenue Bristol, PA 19007 (215) 781-0500 (main) (215) 781-0508 (fax) 38