Energy Recovery with Cooling and Heating

Similar documents
Energy Recovery with Cooling and Heating Model ERCH

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

Energy Recovery Ventilators

Modular Supply Make-Up Air Unit

Indirect Gas-Fired Make-Up Air

THE ULTIMATE ROOFTOP SOLUTION

RT-OA TM Rooftop Outdoor-Air (DOAS)

XeteX, Inc. All Rights Reserved.

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Bill McCullough. Director ERV Products. Dallas, TX

Direct Gas-Fired Make-Up Air Models DG and DGX

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

Modular Heating & Ventilating Unit Model IGX-HV

MAXA-MI$ER Energy recovery solutions

Plenum Fans. Model HPA. Direct Drive

Product Release Summary

The ultimate fresh air solution.

Direct Gas-Fired Make-Up Air

Maverick II Commercial Rooftop Systems 15 to 75 tons

Direct Gas-Fired Make-Up Air Models DGK, DG and DGX

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

Make-Up Air Systems. Performance. Model DGK, DG, DGX

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

Commercial Packaged Rooftop Systems

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

GreenJet Transfer Fans

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

Designing Energy Efficient Outdoor Air Systems

STEP INSIDE FOR A BREATH OF FRESH AIR. Designed to provide significant outdoor ventilation air to any space.

TYPICAL CPA SPECIFICATIONS

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

62DA,DB,DC,DD,DE,DF07-38

RT-OA TM Rooftop Outdoor-Air (DOAS)

Cultivator & Hybrid Cultivator

Design Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE

Economical, Flexible, Advanced Performance. Ventilation and Dehumidification for Healthy IAQ

Vision and Skyline Semi-custom Air Handlers

Munters Heat Exchangers

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

RoofPak Applied Rooftop Systems

ALL PRODUCTS BROCHURE

Energy Recovery Ventilation

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

Flexible & Innovative. Cooling Solutions

MECHANICAL PRODUCTS VOLUME 9

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

DES CHAMPS PRODUCTS 85% 4,400 CFM

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

THE RIGHT SPEC. RIGHT NOW.

Heat pump and energy recovery systems

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

DOAS UNITS. ReznorHVAC.com MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR

MECHANICAL PRODUCTS VOLUME 8

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

BOOK 2 SPECIFICATIONS

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Benefits Offered by Passive Dehumidification Wheel Speed Control

C13-Series Engineering Guide

AHU ENERGY RECOVERY VENTILATORS ERV DEDICATED OUTDOOR AIR SYSTEMS DOAS HEATING, COOLING & DEHUMIDIFICATION AHU

CHAPTER 4. HVAC DELIVERY SYSTEMS

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

Adding More Fan Power Can Be a Good Thing

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

VH Series B ENVIRO-STAC Vertical Hi-Rise Fan Coil Unit with Enhanced Humidity Control

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

H2O COIL. Heat Exchange and Air Movement Products Product Preview

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

SECTION (15733) - DEDICATED OUTDOOR AIR UNITS

Installation, Operation and Maintenance Manual

AHRI Guideline W (I-P) 2014 Guideline for Selecting, Sizing, & Specifying Packaged Air-to-Air Energy Recovery Ventilation Equipment

ASHRAE Standard 90.1 Energy Requirements Wrap-Around Heat Pipes

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

AHRI Certification Program Scopes - COOLING

Trane Performance Climate Changer Air Handlers. An air handler for every need.

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

Wall Mounted Air Conditioners with Gas Heat Models AVGA

RGE 13 A T - 1 A

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST

Transcription:

Energy Recovery with Cooling and Heating VersiVent - Model VER Commercial Institutional 2,000-10,000 cfm 3.0 in. wg external static pressure Configurable September 2008

Page The VersiVent Header Model VER Advantage One Unit for Your Ventilation Needs The need for energy recovery in the HVAC market is being highlighted by increased outdoor air requirements, along with the attention to energy costs through LEED initiatives and ASHRAE guidelines. Increased ventilation rates in combination with energy recovery products will improve your indoor air quality (IAQ) without the associated costs of conditioning outdoor air. Greenheck s VersiVent air-to-air energy recovery model continues our leadership in the industry by supplying equipment that promotes productive and healthy environments. The semi-custom configuration of the VersiVent offers the quality construction, flexibility and performance found in a custom unit, without the cost or lead-time. With a variety of standard and optional accessories, the VersiVent has been designed to meet your application needs. VersiVent (model VER) ADVANTAGE Up to 10,000 cfm and 3 in. wg external static pressure Multiple wheel choices for: Most economical Best effectiveness Best RER (Recovered Energy Ratio) Multiple heating and cooling options Cooling: Chilled Water, Split System DX and Packaged DX with R410a refrigerant Reheat: Modulating Hot Gas Reheat (DX), Wrap-Around Heatpipe Heating: Hot Water, Electric and Indirect Gas Furnace Standard 2 in. double-wall construction Centrifugal airfoil wheel supply fan, model QEP Why Use Energy Recovery? Energy Savings = Quick Payback When a total energy recovery wheel is implemented in an HVAC system, it provides both initial cost savings by cutting cooling tonnage and also annual savings by preconditioning the outdoor air. Combining these two cost saving features leads to an attractive payback on these units. Energy recovery units should be viewed as an investment and not just another piece of HVAC equipment. Improved Indoor Air Quality (IAQ) Introducing fresh, outdoor air to a building is a key component to sustaining excellent IAQ. Preconditioning outdoor air with the VersiVent (model VER) energy recovery unit offers an economical approach for providing high rates of outdoor air. LEED Credits For Green Building designs, the VersiVent offers an excellent way to acquire credits in both the Energy and Atmosphere (EA) and Indoor Environmental Quality (EQ) categories towards a LEED certification. Adhering to ASHRAE Guidelines ASHRAE Standard 90.1 provides design guidelines regarding when it is most beneficial to use energy recovery. Depending upon your geographic location, and the percentage of outdoor air in the application, ASHRAE recommends when to use energy recovery. An important part of this guideline is that when energy recovery is recommended, the device should be a minimum of 50% total (sensible and latent) effectiveness according to AHRI 1060 testing procedure. 2

The Page Greenheck Header Advantage Greenheck takes pride in offering a high quality, reliable product. We invest much of our resources into designing, testing and manufacturing products to ensure customer satisfaction. VersiVent Product Features High Performance Polymer Wheel Polymer base with silica gel desiccant bonded into the material for over 75% total effectiveness Moisture transfer capabilities are maintained and will not lessen with repeated cleaning Lightweight and segmented for easy maintenance Extensive Testing and Industry Certification ETL listing for electrical and overall unit safety AHRI Certified Energy Wheels AMCA Licensed Fans and Dampers Wheel Performance Options Loose Wrap Density Tight Wrap Density Standard Wheel Depth Good RER Economical Choice Good Effectiveness Economical Choice High Performance Wheel Depth Excellent Effectiveness Best RER Best Effectiveness Excellent RER Value RER (Recovered Energy Ratio): The ratio of energy recovered by the energy recovery wheel to the energy expended in the recovery process Every unit is tested at the factory before it is shipped to the jobsite. Quality and Consistency in Manufacturing Greenheck utilizes an efficient, automated manufacturing process that maintains Greenheck s consistent high standard of quality. Energy recovery wheels are certified by the AHRI Air-to-Air Energy Recovery Ventilation Equipment Certification Program in accordance with AHRI Standard 1060. Actual performance in packaged equipment may vary. Certified ratings are available in the Certified Products Directory. Visit www.ahrinet.org and click the Find Certified Products link. Leading Edge Service and Support Our products are supported by the industry s best product literature, electronic media, and Computer Aided Product Selection (CAPS) program. You ll also find this information on our Web site at www.greenheck.com Our national and international representative organization provides personal service and expertise. To locate your nearest Greenheck representative, call 715-359-6171 or visit our Web site at www.greenheck.com 3

2 3 Page VersiVent Designed Header to Meet Your Application Needs The VersiVent model VER comes with a multitude of options and accessories to meet your application requirements. Plenum Supply Fan Backward inclined airfoil centrifugal wheel L10 80,000 hour bearings Third-party certified blower for sound & air performance 1-inch spring isolation 12 bladed design for quiet operation Double-Wall Construction 2-inch insulation secured in place between solid inner and outer panels Insulation density of 1.5 lbs/cu. ft. 1 Total Energy Wheel Sensible & latent energy recovery Lightweight, segmented wheel for easy cleaning with rated L10 bearing life in excess of 400,000 hours Permanently bonded, silica gel desiccant for latent transfer long term durability Stainless steel housing (Smaller cabinet sizes will have a single wheel only) 4 Pre- and Post-Filters MERV 8 pre-filters in outdoor airstream and return airstream MERV 8 or MERV 11 postfilters 8 2 Hinged Access Doors Provides access for maintenance Easy lift-off removable doors Control Center Blower motor starters Wheel motor contactor Disconnect switch with single point wiring Low voltage terminal strip are provided Control Center 7 5 Weatherhood Louvered intake hood that meets AMCA 500L for wind driven rain penetration 2-inch aluminum mesh filters (mist eliminating) Exhaust hood with integral backdraft damper Weatherhood Variable Frequency Drives Fully programmed, variable frequency drive (VFD) for the supply and exhaust blower motors that vary airflow Fully programmed VFD for energy wheel control 4

Product Page Header Features S O Standard Feature Optional Feature 3 1 1 5 Additional Accessories Factory mounted sensors (temperature, pressure, amp) Dampers - internally mounted Frost control Economizer control (stop wheel or modulating wheel) Roof curbs Painted exteriors Rotation sensor CO 2 sensor Dirty filter sensors 4 6 9 Heating Options Hot water coils Indirect gas (IG) furnace Electric heater IG Heater 9 8 Condensing Fans (PDX only) Direct drive Statically and dynamically balanced Dual condensing fans Head pressure control -- improves efficiency 6 Cooling Options Packaged direct expansion [PDX] (shown) Chilled water coils Split DX coil (coil only, R-22 or R-410a refrigerant) All coils with copper tubes with permanently expanded aluminum fins Mounted on a stainless steel drain pan Drain Pan PDX & Hot Gas Reheat Coils 7 Compressors (PDX only) Quiet running hermetic, scroll-type 7-31 Tons of mechanical cooling 2 circuits -- better temperature control 5 Reheat Options Compressors Wrap-around heatpipe On/off hot gas reheat Modulating hot gas reheat - ON/OFF hot gas reheat coil coupled with a modulating bypass damper - Uses recycled energy to reheat the air

Page Applications Header Typical Applications for Energy Recovery Animal Shelters Bars and Clubs Churches Dormitories Locker Rooms Nursing Homes Office Buildings Printing Shops Restaurants Schools Function Halls Casinos Veterinary Hospitals 100% Outdoor Air System The VersiVent unit can be utilized as a 100% outdoor air unit. By combining the benefit of the total energy wheel, with supplemental heating and cooling, the model VER is an energy-efficient method of delivering conditioned outdoor air to a space. In this application the model VER is tasked with all of the air tempering for the space. Benefits 75% energy recovered from exhaust air Good humidity control LARGE SPACE SUPPLY AIR OUTDOOR AIR UNIT (OA unit) WITH ENERGY RECOVERY EXHAUST AIR 72 F OUTDOOR AIR 65% Dedicated Outdoor Air System A Dedicated Outdoor Air Unit, the VersiVent (model VER) supplies conditioned, outdoor air to several zones in a building. The supplemental cooling on the model VER should be sized to handle the outdoor air ventilation load, along with the space latent load. In each zone, a separate air handling unit performs sensible-only comfort heating and cooling. Benefits Minimum total supply airflow while maintaining good IAQ Lowered Energy Costs Good humidity control RELIEF AIR SUPPLY AIR EXHAUST AIR AIR HANDLING UNIT (AHU) Cooling Coil Heating Coil CLASSROOM AHU CLASSROOM 72 F 72 F ZONE 1 ZONE 2 OUTDOOR AIR UNIT (OA unit) WITH ENERGY RECOVERY OUTDOOR AIR EXHAUST AIR RETURNING AIR RESTROOM RELIEF AIR 6

Dimensions Page Header & Weights Unit Size A B C D* E F G H I W L* D 1 D 2 D 3 D 4 VER-45 15.7 28.1 44.6 30.2 36.2 44.2 50.3 36.3 47.6 64.0 66.5 19.0 70.0 VER-65 15.7 30.9 46.6 30.2 36.2 44.2 50.3 38.1 47.6 66.0 72.8 23.8 76.2 VER-90 15.7 34.9 85.6 30.2 36.2 44.2 50.3 41.3 47.6 66.0 66.6 25.3 91.0 All dimensions are shown in inches. L*: Please sum the lengths of the appropriate modules to get the total length of the unit. Model VER-45 VER-65 VER-90 D*: Coil Module Options Unit CFM Range Min 2000 4000 6000 D 1 D 2 D 3 D 4 Max 5000 7000 10000 HW HW + DX CW + HP HW + CW + HP Motor HP Min 1.5 3 5 CW HW + CW DX + HP HW + DX + HP Max 7.5 15 20 DX EH + CW DX + HGRH EH + DX + HP External Static Min 0 0 0 EH EH + DX DX + HW + HGRH EH + CW + HP Pressures (in. wg) Max 3 3 3 DX + EH + HGRH **Weights (lbs) 4900 6300 7250 **The weights shown are a worse case scenario based on the sheet metal and component weights for the unit. These weights include sheet metal weights added together with the largest fans, coils and heaters for the unit. HW=Hot Water CW=Chilled Water DX=Direct Expansion EH=Electric Heat HGRH=Hot Gas Reheat HP=Wrap-around Heat Pipe 7

Greenheck s Energy Recovery Models Model MiniVent - Energy Recovery Ventilator The MiniVent-450 & 750 are energy recovery ventilators used for commercial and institutional applications that require 300 to 800 cfm of ventilation air. The compact design provides an economical solution for individual spaces, such as school classrooms and small offices. Model ERV/ERVe - Energy Recovery Ventilator Low first-cost and maximum energy savings combine to yield an extremely attractive payback on Greenheck Energy Recovery Ventilators. By incorporating ERV s into the HVAC system, air conditioning and heating equipment can be downsized. Energy recovery ventilators are perfectly suited to help control humidity. In the summer, when outdoor humidity is high, the energy wheel dehumidifies the outdoor air. This greatly reduces the latent load on the air conditioning equipment and also eliminates rising indoor humidity levels that can occur in hot, humid climates. In the winter, when outdoor air is dry, the energy wheel humidifies the air. This increases comfort and reduces the amount of humidification required. Capacities for model ERV range from 400 to 12,000 cfm with external static pressure capabilities to 1.5 in. wg. Capacities for model ERVe range from 1,000 to 6,000 cfm with external static pressure capabilities to 1.0 in. wg. Model ERCH - Energy Recovery with Cooling and Heating The model ERCH combines the benefits of the total energy wheel with supplemental cooling and heating. The result is a product that is specifically designed to process 100% outdoor air to desired supply conditions. Four housing sizes provide airflow capacities from 1,000 to 10,000 cfm with external static pressures to 1.5 in. wg. A variety of tempering options are available. The coil section of the ERCH accommodates a cooling coil, a heating coil, or both. Model VER - Versatile Energy Recovery The Model VER is a fully featured, versatile energy recovery unit with a wide range of heating and cooling options available. The unit includes an energy wheel to pretemper the outdoor air which reduces the heating and cooling equipment needed, while also lowering operational costs. In addition to the standard heating and cooling options, the VersiVent has options such as environmentally friendly R410a refrigerant, a wrap-around heat pipe for additional dehumidification and reheat capacity, and a quiet, efficient, plenum supply fan. Capacities range from 2,000 to 10,000 cfm with external static pressure capabilities to 3 in. wg. Model APEX - Affordable, Practical, Energy Exchanger The APEX combines high airflow capacities with cost-saving energy recovery ventilation by providing centralized outdoor air distribution and reducing the need for multiple unit installations. Fresh outdoor air is preconditioned by the total enthalpy wheel, which recovers a majority of the energy from the exhaust air. It saves 3 4 tons of cooling per 1,000 cfm and saves 50-60 MBH of heating per 1,000 cfm. Easy to install and operate with airflow capacities that range from 10,000 to 20,000 cfm and external static pressures to 2.5 in. wg. Our Warranty Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the shipment date. The energy recovery wheel is warranted to be free from defects in material and workmanship for a period of five years from the shipment date. Any units or parts which prove defective during the warranty period will be replaced at our option when returned to our factory, transportation prepaid. Motors are warranted by the motor manufacturer for a period of one year. Should motors furnished by Greenheck prove defective during this period, they should be returned to the nearest authorized motor service station. Greenheck will not be responsible for any removal or installation costs. Prepared to Support As a result of our commitment to continuous improvement, Greenheck reserves the right to change Green Building Efforts specifications without notice. Greenheck P.O. Box 410 Schofield, WI 54476-0410 Phone (715) 359-6171 greenheck.com Copyright 2008 Greenheck Fan Corp. VersiVent, Rev. 2, September 2008 RG (00.TAP.1009 R2 9-2008)