NFPA Edition Review

Similar documents
2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

Why Selective Coordination is Mandatory -- It Fills the Reliability Hole --

Electrical Hazards and NFPA-70E: Protecting Your Employees

ANSI/NETA Standards Update

NFPA Updates (c) 2015 SSR, Inc. All rights reserved Florida AHCA Conf

The Impact the Reference Standards in the 2012 Edition of NFPA 101 have on the Operation of Health Care Facilities: NFPA 80 and 99

NFPA 70E Standard for Electrical Safety in the Workplace. EEI Safety and Health Meeting May 2011

Electrical Safety Compliance: NFPA 70E

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

David Stymiest, PE, CHFM, CHSP, FASHE cell Copyright 2014, Smith Seckman Reid, Inc.; All rights reserved

Welcome DISCLAIMER. Testing Electric Fire Pumps You Need to Understand the Arc Flash Hazard 5/1/ NFPA Conference & Expo

Alex Masterton, PE Electrical Engineer Reviewer AHCA Neal Boothe, PE Electrical Engineer/Principal

NFPA 99 for Facility Managers

2017 NEC: Impact to Electrical System Designs

GPS 140 NEC Requirements for Generators. Professional Development Seminar Series NEC Requirements for Generators

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC

ELECTRICAL BULLETIN

Electrical Tech Note 107

Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance

Construction Codes Advisory Council

Chapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...

NEC Requirements for Standby Power Systems. New England Building Officials Education Association Annual Conference October 5, 2015

4/18/2017. *2012 edition of NFPA 99 has gone through a major overhaul. *This document is now a Code.

ORDINANCE NO

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

Are Open Bottom Electrical Handholes a NEC Violation? Proposals to Change the 2002 NEC Traffic Signal and Roadway Lighting Related

IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016

Electrical Safety Through Design. Mersen EP formerly Ferraz Shawmut

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

Life Safety Code NFPA 10 NFPA 13 NFPA 25 NFPA 72 NFPA 90A NFPA 110 NFPA 99 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #7

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Proposed Changes to NFPA

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

NECA. Standard for Electrical Safety in the Workplace

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

IMPROVE SAFETY WITH ARC FLASH LABELING COMPLY WITH THE 2015 NFPA 70E REGULATIONS

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Safety requirements for voltage testing instruments

NFPA 70E Elevates Safety. with Heightened Risk Awareness

Combination Type AFCI

PANELBOARDS & BUILDING DISTRIBUTION

Arc Flash Analysis: IEEE Method versus the NFPA 70E Tables July 2017 / 1910DB1702

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

PGR-8800 TECHNICAL FAQ

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

National Electrical Code

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

27th Annual AHCA Seminar

Revisions for the 2014 National Electrical Code Part 3

TABLE OF CONTENTS CHAPTER 5 SPECIAL OCCUPANCIES CHAPTER 1 GENERAL RULES... 19

2014 National Electrical Code & NFPA 70E/Arc Flash

Arc Flash and Selective Coordination

AD HOC HEALTHCARE COMMITTEE MEANS OF EGRESS WORK GROUP APPROVED CODE CHANGE DRAFTS CODE GROUP B MOE COMMITTEE

Compatibility between Smoke Alarms and Arc-Fault Circuit Interrupters

Introduction Consultant shall incorporate the material in the DSS into the project specifications.

Report on Comments June 2013 NFPA 70

E25 (D) Automatic controls for general means of egress lighting

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

Overview of Significant 2017 NEC Changes

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017

Arc Flash Protection Training - NFPA 70e Electrical Safety

SECTION ENCLOSED CONTROLLERS

EC Standard & NFPA 110 (EPSS) Documentation Best Practice. 1: Division Team Mission

Revisions for the 2011 National Electrical Code - Part 1

NFPA 79 - Second Draft Meeting July 8-10, DoubleTree Hotel, Portland, ME

NFPA 99 Risk Assessment

CONTINUING EDUCATION FOR OREGON ELECTRICIANS. AMERICAN ELECTRICAL INSTITUTE PO Box Spokane, WA

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

SEL Arc-Flash Solutions

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

EC EP 14 All other electrical K-920 equipment in patient care vicinity NFPA , Chapter 10

NECA S System Approach to Electrical Safety for NFPA 70E

Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for

CHFM, CHSP, FASHE (PE

TOPICS IN CODE ENFORCEMENT

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,

SEL Arc-Flash Solutions

CITY & COUNTY OF DENVER COMMUNITY PLANNING & DEVELOPMENT BUILDING PERMIT POLICY

CITY OF LOS ANGELES LARUCP ELECTRICAL PLAN CHECK LIST

NECA S System Approach to Electrical Safety for NFPA 70E

Building Electrical System Overview

Centennial Energized Electrical Work Permit Instructions

Compliance w/ the 2012 Life Safety Code

Standards and Safety Update

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

In the Eye of the Beholder: Electrical Codes from the View of the AHJ and the Designer

Medical Gas Inspections and Maintenance Programs. HESNI Annual Conference NIU Conference Center May 10-11, 2018 Presented by Mathis Carlson

Demystifying Power Tap Use in Healthcare Settings John Garbarino Sr. Marketing Manager, Commercial/Industrial Leviton Manufacturing Co.

White Paper SPDs for Essential Power Systems in Health Care Facilities

Safety Meeting Topic #37 NFPA 70E What is it?

IEEE Std IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations

PREVIEW COPY. Table of Contents. Annexes and Supplemental Materials Lesson One Article 90: Introduction and Purpose... 3

NFPA 70E Arc Flash Considerations for MV Equipment. By: Dominik Pieniazek, P.E. HV Engineering, LLC

Changes in NFPA

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

ELECTRIC and NEON SIGN STANDARDS. By Randy Wright RKW CONSULTING

ELECTRICAL REQUIREMENTS FOR HEALTH CARE FACILITIES

Transcription:

This is a photographic template your photograph should fit precisely within this rectangle. NFPA 70 & 99 How Recent Code Changes Effect Healthcare Facilities Sam C. Terry, P.E. Application Engineer Eaton Corporation (713)849-1646 samuelcterry@eaton.com 2013 Eaton Corporation. All rights reserved. NFPA 99 2012 Edition Review Replaced the 2005 Edition MAJOR overhaul of the document by NFPA Postponed Scheduled for 2010 Postponed / Returned to Committee Went through 2 Complete Code Cycles NFPA 99 - Standard for Health Care Facilities is Makes this an adoptable and 2 2 enforceable Code 1

Major Structural Revision Document organization changed from Facility- based document to a Risk-based document Eliminates existing Chapters 13 19 that covered different types of facilities (i.e. hospital, nursing home, birthing center, etc.) Requirements for systems are now based on the risk to the patient / staff involved Several Contentious Electrical Issues 1. Wet Procedure Locations 2. Selective Coordination 3. Application to Existing Systems 4. Performance vs Installation 3 3 Risk Categories NFPA recognized that the basic facility type did not necessary reflect the type of procedures done or risk to patient / staff Existing Chapters 13 18 of 2005 Edition Lots of blurring of the lines has occurred on the types of procedures that are performed in different types of the health care facilities Risk to the patient / staff doesn t change for a given procedure New document requires a risk assessment is to be done to determine the Category of risk Determination of the risk Category determines the requirements for all Chapters of the document 4 4 2

Risk Categories Chapter 4 Fundamentals (New Chapter) Building System Categories Applied to rooms or areas witin the facility Category 1 Facility systems in which failure of such equipment or system is likely to cause major injury or death of patients or caregivers Category 2 Facility systems in which failure of such equipment or system is likely to cause minor injury to patients or caregivers Category 3 Facility systems in which failure of such equipment or system is not likely to cause injury to the patients or caregivers, but may cause patient discomfort Category 4 Facility systems in which failure of such equipment or system would have no impact on patient care The Category of the area being served determines the requirements of the Essential Electrical System (EES) Critical Care Room = Category 1 Space = Type 1 EES General Care Rooms = Category 2 Space = Type 2 EES Basic Care Room = Category 3 Space = No EES requirement Non-Patient Care Rooms = Category 4 Space = No EES requirement 5 5 NFPA 99 2012 Edition Other Document Changes Electrical Systems moved from Chapter 4 to 6 NEW! Information Technology and Communications Systems for Health Care Facilities Chapter 7 NEW! Plumbing Chapter 8 NEW! Heating, Ventilation, and Air Conditioning (HVAC) Chapter 9 NEW! Security Management Chapter 13 NEW! Features of Fire Protection Chapter 15 Eliminated - Occupancy Chapters 13 18, 21 6 6 3

NFPA 99 2012 Edition Key Electrical Changes Chapter 6 Chapter applies to new health care facilities primarily (renovations?) Some changes will apply retroactively to existing facilities (must meet 1999 NFPA 99 3-3.3.2&3 6.1.2 Lists the sections that apply to new and existing facilities Receptacles must have a grounding pole Tamper resistant receptacles or tamper-resistant receptacle cover required in Pediatric locations Receptacles, fixed electrical equipment, and corded equipment must be tested after damage, after repair, or at least every 6 months OR s defined as wet procedure locations shall have IPS or GFCI Receptacle covers for life safety and critical branches shall have distinctive markings in Type 3 EES Maintenance, Testing, Recordkeeping, and Administration requirements as in previous editions 7 7 Key Electrical Changes Chapter 6 Eliminated term Emergency System from NFPA 99 In 2005 edition, Emergency System is the name given to the Life Safety and Critical Branches of the Essential Electrical System Not the same Emergency System as Article 700 of the NEC Helps remove the scope confusion between Health Care facilities and Article 700 (i.e. 100% Selective Coordination, generator sizing, etc.) Essential Electrical System now consists of (3) separate branches 1. Life Safety Branch 2. Critical Branch 3. Equipment Branch Division of the branches occurs at the transfer switch where more than one transfer switch is required Eliminates challenges with separation of branches all the way back to the Generator or Emergency Switchgear. 8 8 4

Key Electrical Changes Chapter 6 6.3.2.2.1.3 Access Overcurrent devices service Category 1 and 2 rooms not permitted in public spaces 6.4.2.2.1.2 The division between the branches shall occur at the transfer switches where more than one transfer switch is required. 6.4.2.2.2 Feeders from Alternate Source. (A) A single feeder supplied by a local or remote alternate source shall be permitted to supply the essential electrical system to the point at which the life safety, critical, and equipment branches are separated. (B) Installation of the transfer equipment shall be permitted at other than the location of the alternate source. 9 9 Key Electrical Changes Chapter 6 6.3.2.2.6.2 Minimum Number of Receptacles General Care Areas (Category 2) 8 receptacles Critical Care Areas (Category 1) 14 receptacles Operating Rooms (Category 1) 36 receptacles 6.3.2.2.7.1 Isolated Ground Receptacles Isolated ground receptacle not allowed in patient care vicinity 6.3.2.2.8 Wet Procedure Location 6.3.2.2.8.4 All Operating Rooms are considered to be wet procedure locations, unless a risk assessment determines otherwise Wet procedure locations require either GFCI or Isolated Power Systems No preference is given to either type of protection This issue created much debate in the TC and several motions 10 10 5

Key Electrical Changes Chapter 6 Essential Electrical System Changes 6.4.2.2.3.3 Alarms and alerting systems (except fire alarm system) can be on either life safety or critical branch 6.4.2.2.3.4 All generator support equipment required to be on Life Safety Branch (formerly part of the equipment branch) 6.4.4.1.1.2 10-second criterion does not apply for monthly testing. Must be proved annually. Allows the use of closed transition ATS that may take more time to sync between two live sources 11 11 Selective Coordination Selective Coordination requirement added for Type 1, 2, and 3 EES 6.4.2.1.2, 6.5.2.1.1, 6.6.2.1.1 Overcurrent protective devices serving the essential electrical system shall selectively coordinate for the period of time that a fault s duration extends beyond 0.1 second. More on this later Included the same exceptions from Art. 700 for: Transformer primary and secondary OCPD s of the same size in series 12 12 6

Selective Coordination Discussion Protective Devices 13 13 13 Selective Coordination Highly contentious issue in the NEC and in NFPA 99 Numerous Motions and Appeals from NEFA (National Electric Fuse Association), IBEW, and NECA challenging the new NFPA 99 requirements All were defeated numerous times! Highlighted the need to differentiate between performance requirements and installation requirements NFPA 99 Health Care Facilities Code 1.1 Scope 1.1.4.1 Electrical Systems 1.1.4.1 Chapter 6 covers the performance, maintenance, and testing of electrical systems (both normal and essential) in health care facilities. 14 14 7

Performance vs Installation Requirements Technical Correlating Committee formed a Task Group on Innercommittee Coordination on Emergency Electrical Systems Performance Requirement A specification of the manner in which equipment or a system is intended to function or operate. Installation Requirement A specification of the material and process associated with putting equipment in place and making it ready for use in accordance with performance requirements. Standards Council clarification to Technical Committees - if the scope of their document is performance, they can only write performance requirements. If scope is installation, then can only write installation requirements. A recent example related to the 2014 NEC: CMP-15 (Art. 517) added a requirement that all Life Safety and Critical branch outlets must have an illuminated face or an indicator light to indicate there is power to the receptacle. Overturned by the Standards Council as it was determined to be a performance requirement (NFPA 99), and not an installation requirement (NFPA 70). 15 15 Proposals for 2014 NEC As a result of the Standards Council s Decision, coordination is needed between NFPA 99 2012 and Article 517 of the NEC Intercommittee coordination task group created NEC and NFPA 99 are on different Code Cycles Proposals were made by Walt Vernon, NFPA 99 ELS - Technical Committee Chair Mostly clerical to harmonize the terminology rooms vs areas branches vs systems Minimum number of receps Etc. All proposals were accepted exactly as proposed with the exception of Selective Coordination more to follow 16 16 8

This is a photographic template your photograph should fit precisely within this rectangle. Selective Coordination 2013 Eaton Corporation. All rights reserved. Selective Coordination Simplified During an overcurrent event, the goal is to keep the number of devices that open to a minimum. 18 18 9

P S P S P S P S P S P S 3/21/2014 What devices are required to Selectively Coordinate? U TIL ITY A UTILITY B GE N #1 GEN #2 MAIN A MAIN B MSG -TIE GEN #1 MAIN GEN #2 MAIN MSG-A MSG -B GE N SW GR CHILLER FD R DISTR PNL FDR ATS-EQ NORM ATS-CR NORM AT S-LS NORM ATS-EQ EMER ATS-CR EMER ATS-LS EMER C BL-C HILLER CBL-DIST R PNL C B L-AT S EQ N CBL-ATS CR N CBL-ATS LS N CBL-0005 CBL-0006 CBL-0007 CHILLER 3. Normal source to the line side of the ATS??? 480V LRGST DISTR PNL 480V LTG PNL FDR C BL- 48 0V LT G P N L 48 0 V LT G P N L N E N E N E AT S-EQ ATS-CR ATS-L S CBL-EQ 480V PNL CBL-CR 480V PNL CBL-LS 480V PNL EQ 480V PNL CR 480V PNL LS 480V PNL 2. Emergency source to the line side ATS LTG BRANCH EQ XFM R PR I CR XFM R PRI LS XFMR PRI CBL-EQ XFMR PRI CBL-CR XFM R PR I CBL-LS XFMR PRI EQ XFMR CR X FM R LS XFMR 1. Load side of any Emergency System ATS CBL-EQ 208V PNL CBL-CR 208V PNL CBL-LS 208V PNL EQ 208V PNL MAIN CR 208V PNL M AIN LS 208V PNL MAIN EQ 208V PNL CR 208V PNL LS 208V PNL EQ 208V B RANCH CR 208V BRANCH LS 208V BRANCH 19 19 What devices are required to Selectively Coordinate? U TIL ITY A UTILITY B GE N #1 GEN #2 MAIN A MAIN B MSG -TIE GEN #1 MAIN GEN #2 MAIN MSG-A MSG -B GE N SW GR CHILLER FD R DISTR PNL FDR ATS-EQ NORM ATS-CR NORM AT S-LS NORM AT S-EQ E MER ATS-CR EMER ATS-LS EMER C BL-C HILLER CBL-DIST R PNL C B L-AT S EQ N CBL-ATS CR N CBL-ATS LS N CBL-0005 CBL-0006 CBL-0007 CHILLER 3. Normal source to the line side of the ATS??? 480V LRGST Is this Zone important for continuity of service? DISTR PNL 480V LTG PNL FDR C BL- 48 0V LT G P N L 48 0 V LT G P N L LTG BRANCH N E N E N E AT S-EQ ATS-CR ATS-L S CBL-EQ 480V PNL CBL-CR 480V PNL CBL-LS 480V PNL EQ 480V PNL CR 480V PNL LS 480V PNL EQ XFM R PR I CR XFM R PRI LS XFMR PRI CBL-EQ XFMR PRI CBL-CR XFM R PR I CBL-LS XFMR PRI This bus sees an unnecessary outage. ATS transfers into a fault. Gen feeds a fault. Normal ATS breaker must be reset for ATS to transfer back EQ XFMR CBL-EQ 208V PNL EQ 208V PNL MAIN EQ 208V PNL EQ 208V B RANCH CR X FM R CBL-CR 208V PNL CR 208V PNL M AIN CR 208V PNL CR 208V BRANCH LS XFMR CBL-LS 208V PNL LS 208V PNL MAIN LS 208V PNL LS 208V BRANCH 20 20 10

NFPA Comment Although the emergency systems of a hospital are designated as the life safety branch and the critical branch (see 517.30 (B)(2)), Section 517.26 requires that the essential electrical system meet the requirements of Article 700. Therefore, since the essential electrical system in accordance with 517.30 (B)(1) includes the equipment system the provisions of Section 700.27 are also applicable to the equipment system as follows: Section 700.27 requires all emergency system overcurrent devices to be selectively coordinated with all upstream overcurrent protective devices. The phrase selectively coordinated with all supply side overcurrent protective devices does not limit the requirement to only those that are installed in series with the alternate supply source for the emergency system and includes coordination with the normal side providing the normal side supplies the essential circuits during normal operation. Section 700.27 is silent on overcurrent devices that are not in series with essential system overcurrent protective devices. Although the scope of Article 700 does not include supplies other than emergency, 700.27 is specific in that all the emergency system overcurrent devices must be selectively cooridinated with all supply side devices which would include those on the normal side unless the exceptions to 700.27 apply. Note: See ROP15-68, associated comments and the 2011 NEC draft for changes to 517.26 for future reference. Mark Cloutier NFPA Senior Electrical Engineer Important notice! This correspondence is not a Formal Interpretation issued pursuant to NFPA Regulations. Any opinion expressed is the personal opinion of the author, and does not necessarily represent the official position of the NFPA or its Technical Committees. In addition, this correspondence is neither intended, nor should be relied upon, to provide professional consultation or services. 21 21 22 22 11

What devices are required to Selectively Coordinate? What about GF Protection? What about coordination with required GF protection? Required on 1 st 2-levels for Health Care applications Max GF pick-up = 1200 Amps Max GF delay = 0.5 sec FD Won t coordinate with even Fixed small downstream breakers Not addressed in the Code or by the CMP-13 0.5 1 Are more levels of GF needed? 1 10 1000 1000 MAIN B CUTLER-HAMMER Magnum DS, DT 1150/1150i Trip 3000.0 A Plug 3000.0 A Settings Phase GFPU, (1150, 0.25-1) 0.4 (1200A) GFD, (0.1-0.5s) 0.5 (I^2t Out) 100 100 ATS-EQ NORM CUTLER-HAMMER Magnum DS, DT 520 Trip 800.0 A Plug 800.0 A Settings Phase GFPU, (0.25-1 x In) 1 (800A) 10 10 GFD, (0.1-0.5s) 0.3 (I^2t Out) EQ XFMR PRI CUTLER-HAMMER 1 1 Trip 200.0 A Settings Phase 0.10 0.10 0.01 0.01 10 CURRENT IN AMPERES 100 100 1K 1K 10K 10K TIME IN SECONDS 23 23 2014 NEC / 2015 NFPA 99 There has been significant effort since 2012 NFPA 99 was released to correlate between it and Article 517 of the NEC A series of proposals from the NFPA 99 Technical Committee were submitted for Article 517 and accepted to harmonize language 24 24 12

2015 NFPA 99 Key Changes 2014 NEC (CMP-13) changes the definition of Coordination (Selective) 100. Coordination (Selective). Localization of an overcurrent condition to restrict outages to the circuit or equipment affected, accomplished by the choice selection and installation of overcurrent protective devices and their ratings or settings for the full range of available over-currents, from overload to the maximum available fault current, and for the full range of overcurrent protective device opening times associated with those over-currents. 25 25 2015 NFPA 99 Key Changes 2014 NEC (CMP-15) then moved away from the term Coordination (Selective) 517.30 (F) Coordination. Overcurrent protective devices serving the essential electrical system shall be coordinated for the period of time that a fault s duration extends beyond 0.1 second. Informational Note: The terms Coordination and Coordinated as used in this section do not cover the full range of overcurrent conditions. 26 26 13

2015 NFPA 99 Key Changes Clarifies that the Health care requirement for Coordination at 0.1 sec. & above is different than the requirement for Coordination (Selective) in Sections 620.62, 700.27, 701.27, and 708.54. 2015 NFPA 99 will correlate with Art. 517 of the 2014 NEC Adopted same language and added the Informational Note to the Annex material 27 27 Selective Coordination Discussion Protective Devices 28 28 28 14

Optional slide The next slide will only be used if additional detail is required on.1 second or equipment ratings. This slide and next are hidden. 29 29 Selective Coordination Discussion Protective Devices IN ADDITION TO THE INCREASED SPACE AND 1 ST COSTS ARC FLASH HAZARD HAS BEEN INCREASED THE ONLY ADVANTAGE OF CASE 2B IS TOTAL COORDINATION IN A BOLTED FAULT CLASS L FUSES WILL TYPICALLY COORDINATE TO 13,000A WILL TYPICALLY PROVIDE GOOD REAL WORLD PROTECTION (PARTIAL PROTECTION) 30 30 30 15

2015 NFPA 99 Key Changes Most other NFPA 99 2015 changes are related to clean up efforts Still have a ways to go on organization of Chapter 6 GFCI used in Operating Rooms Where GFCI protection is used in an operating room: Each receptacle shall be a GFCI device, or Each receptacle shall be individually protected by a single GFCI device Room vs Area vs Space The term space is replacing area or room Example: Category 1 space (in lieu of Critical Care Area, or Category 1 room) 31 31 2015 NFPA 99 Key Changes Only the life safety branch must comply with Art 700 (Emergency Systems) of the NEC Additionally, several of the Art. 700 provisions do not apply Generator sizing on demand load, not connected load 1 hour fire rated cabling vs 2 hour fire rated cabling Battery backed lights allowed on the life safety branch 700.27 - Coordination (Selective) 32 32 16

2015 NFPA 99 Key Changes Type 3 Essential Electrical System removed There are no risk Categories that call for a Type 3 EES Receptacle, cord connected, and fixed electrical equipment Eliminated testing interval of every 6 months 33 33 2015 NFPA 99 Key Changes Fuel Cells allowed as an alternate power source Must have N+1 capacity Restore power in 10 seconds or less Sufficient fuel supply with onsite storage for EES type Must include a connection for portable diesel generator to supply life safety and critical branches 34 34 17

2015 NFPA 99 Key Changes Fuel Cells allowed as an alternate power source Must have N+1 capacity Restore power in 10 seconds or less Sufficient fuel supply with onsite storage for EES type Must include a connection for portable diesel generator to supply life safety and critical branches 35 35 NFPA 70E 2012 as supported by NFPA 70 (N.E.C) Key Changes Section 130.3 Arc Flash Hazard Analysis (must review) The arc flash hazard analysis shall be updated when a major modification or renovation takes place. It shall be reviewed periodically, not to exceed five years, to account for changes in the electrical distribution system that could affect the results of the arc flash hazard analysis. Section 130.5 Arc Flash Labeling (increased requirements) (1) At least one of the following: a. Available incident energy and the corresponding working distance b. Minimum arc rating of clothing c. Required level of PPE d. Highest Hazard/Risk Category (HRC) for the equipment (2) Nominal system voltage (3) Arc flash boundary Exception: Labels applied prior to September 30, 2011, are acceptable if they contain the available incident energy or required level of PPE. 36 36 18

37 37 19