Burner control units BCU 480

Similar documents
Burner control unit PFU 780

Burner control units BCU 480

Burner control units BCU 460, BCU 465

Burner control unit BCU 370

Burner control unit BCU 370

Industrial & Commercial Thermal BCU 580

Burner control units BCU 560, 565

Burner control units BCU 560, 565

Control valve S11T. Pilot burner ZT. Control valve S11T

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

Boiler module and operator-control unit KM 921 with CUI 9xx for heating boilers

Safety. Operating instructions UV sensor UVS 5 DANGER. Contents WARNING CAUTION Elster GmbH Edition Please read and keep in a safe place

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

Heating controller Lago

Self-recuperative burner for gas

LFL Series Burner Flame Safeguard Control

Increased efficiency for drying, firing and glazing. Edition GB. Heat treatment in the ceramics industry

Safety. Operating instructions Ionization pilot burners ZAI, ZMI, ZKIH DANGER. Contents WARNING CAUTION Edition 12.11

System controller for cascade control, heating boilers with solar, buffer and pel et control

Energy management with a system. Edition GB. Control engineering and combustion technology for comfortable heating

LAE10 LFE10. Use. Series 02

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

Old documentation - Only for your information! Product is not available anymore!

Increased efficiency for melting, heating and heat treatment. Edition GB. Gas-fired processes in the metalworking industry

Eclipse Self-Check UV Scanner

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

Safety. Operating instructions Heater GP 40 DANGER. Contents WARNING CAUTION. Edition Please read and keep in a safe place

Flame Safeguards LFE10. Building Technologies HVAC Products

DKG 972. Gas Burner Safety Control. For 2-stage atmospheric gas burners

Oil Burner Controls LMO24... LMO44...

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Flame Safeguards LFE10. Building Technologies HVAC Products

UV Flame Supervision System

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

Engineering Guideline. pac- Carriers Type Universal

Oil Burner Controls LMO24... LMO44...

Use. Burner controls for use with forced draught gas or gas / oil burners of small to medium capacity in intermittent operation.

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

7800 SERIES RM7888A Relay Module

Flame Monitors BROCHURE

Burner Management System

D-GF 150. Burner Control for Gas and Oil Burners Flame Sensor D-GF 150 D-LE 103

Burner Management System

AUTOMATIC BURNER CONTROL SYSTEM SAFETY INFORMATION CONFORMITY

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies Landis & Staefa Division

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

Manual MPA 41xx. Edition: Nr GB. Printed in Germany Edition Nr

UV - flame detector dual fuel burners for intermittent burner operations

Use. The burner controls are certified to EN 230 and EN 298.

Power Flame Incorporated

DATASHEET. Burner control unit FDA 601x

DKO 974/976 DKO 974 N/976 N. Oil Burner Safety Control

Manual MPA 4112 PF. Edition: No GB. Printed in Germany Edition Nr

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

Old documentation - Only for your information! Product is not available anymore!

7800 SERIES RM7888A Relay Module

Eclipse Trilogy Flame Safeguards

Instructions for the fan motor control system with integrated wiring terminals SILVER C

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

Operator: Save these instructions for future use!

Fire Detection Systems Product Catalogue (Version )

Safety. Operating instructions Heater GP 95 DANGER. Contents WARNING CAUTION. Changes to edition Please read and keep in a safe place

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

Power Flame Incorporated

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

Safety. Operating instructions Pilot burners ZAI, ZKIH DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 09.

7800 SERIES EC7885A/RM7885A Relay Module

Burner Management and Combustion Control. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.

Danfoss gas detection units

Danfoss gas detection Controller unit

PROFIRE BMS Controller

Sola Hydronic Control. An Eco-Friendly Solution.

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

Forced draught gas burner

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

BC-R10 Series. Burner Controllers

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Instructions for the fan motor control system, SILVER C

Burner Management System

STEAMPAK Series BurnerPAK BMS Burner Management Systems

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

EUROFLAT SERIES TYPES C... S... M...

Quickheat 30 weather compensated boiler control

Model 60200FR Gas Primary Control Data Sheet

Advanced Ultraviolet Burner Controller

Steam Fundamentals. (in heating & processing applications)

1.7. Insulation fault evaluators EDS460/490 EDS461/491

C Note! LGI16... Burner Controls. Building Technologies

7800 SERIES RM7840E,G,L,M Relay Module

Forced draught gas burner

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

Transcription:

Burner control units roduct brochure GB...8 Edition 0.07 For pilot and main burners of unlimited capacity in intermittent or continuous operation pursuant to EN 74- Automatic burner control unit, ignition transformer, indicators and operating controls in a space-saving metal housing which replaces the local burner control cabinet Flame control by UV, ionisation or a further option of using the furnace chamber temperature Display of the program status, unit parameters and flame signal; manual mode for burner adjustment and for diagnostic purposes Visualisation and adaptation to the specific application via the C programming and diagnostic software BCSoft to simplify logistics management Spacious connection chamber with plug-in terminal blocks and plug-in cable glands for quick installation and servicing Air valve control relieves the furnace control Optional ROFIBUS-D interface EC type-tested and certified www.kromschroeder.com

Kromschröder Edition 0.07 Application The burner control units control, ignite and monitor gas burners for intermittent or continuous operation. As a result of their fully electronic design they react quickly to various process requirements and are therefore suitable for frequent cycling operation. Spacious connection chamber with plug-in terminal blocks They can be used for industrial burners of unlimited capacity which are ignited by pilot burners. ilot and main burners may be modulating or stage-controlled. The BCU 480 monitors pilot and main burners independently. The pilot burner can burn permanently or be switched off. The BCU is installed near to the burner to be monitored. On industrial furnaces, the BCU reduces the load on the central furnace control by taking over tasks that only relate to the burner, for example it ensures that the burner always ignites in a safe condition when it is restarted. The air valve control assists the furnace control for cooling, purging and capacity control tasks. The program status, the unit parameters and the level of the flame signal can be read directly from the unit. The burner can be controlled manually for commissioning and diagnostic purposes. If the local requirements on the burner control unit change, the C software BCSoft can be adjusted to the unit parameters of the application by using the optical interface. The service personnel is supported by a convenient visualisation system of the input and output signals and the error history. To reduce the installation and wiring costs, Elster Kromschröder offers an optional ROFIBUS-D interface to transfer the activation signals and feedbacks so as to expand the remote servicing and diagnostics facilities. Bogie hearth forging furnace in the metallurgical industry Intermittent shuttle kiln in the ceramics industry The BCU unites the functionally interrelated components of automatic burner control unit, ignition transformer, Manual/Automatic mode and display of operating and fault statuses in a compact metal housing. Walking beam furnace with overhead firing

Edition 0.07 Kromschröder 3 Examples of application 4 3 3 L, N, E SS LC AI A ϑ 4 4 ϑ 8 9 7 8 9 Stage-controlled main burner with alternating pilot burner Main burner ON/OFF. The main burner can be started with reduced capacity after the operating signal from the pilot burner has been detected. The pilot burner is switched off automatically after the main burner has started up. When the main burner is switched off, the pilot burner automatically switches on again. This reduces the main burner start-up time. A UV sensor monitors the flame signal from pilot and main burners. UV sensor UVD is used for continuous operation, UV sensor UVS for intermittent operation. The BCU provides the cooling and purging processes. UV VR..L 0 04 0 08 0 04 0 08 ϑ ϑ t 3 3 L, N, E SS LC AI A ϑ 4 ϑ 8 9 7 Stage-controlled main burner with permanent pilot burner Main burner ON/OFF. The main burner can be started with reduced capacity after the operating signal from the pilot burner has been detected. ilot and main burners can be operated simultaneously. This reduces the time required by the main burner for starting up. The BCU provides the cooling and purging processes. 4 4 8 9 VR..R 0 04 0 08 04 0 08 04 ϑ ϑ t

Edition 0.07 Kromschröder 4 0 3 4 3 L, N, E SS LC AI A ϑ 4 4 ϑ 8 9 7 8 9 Two-stage-controlled main burner with permanent pilot burner Main burner ON/OFF with ignition via bypass. The main burner can be started at low-fire rate after the operating signal from the pilot burner has been detected. When the operating state is reached, the BCU issues the Enable signal for the maximum burner capacity. ilot and main burners can be operated simultaneously. This reduces the time required by the main burner for starting up. The BCU provides the cooling and purging processes. VAS 4 7 M IC 40 0 04 0 08 04 0 08 04 ϑ ϑ t BV 4 3 L, N, E ma SS LC AI ϑ 4 ϑ 4 8 9 7 8 9 Modulating-controlled burner Main burner continuous The butterfly valve for air is moved to ignition position in order to start the main burner. The main burner can be started at low-fire rate after the operating signal from the pilot burner has been detected. The control system controls the burner capacity via the butterfly valve for air after the operating state has been signalled. ilot and main burners can be operated simultaneously. This reduces the time required by the main burner for starting up. M BV+IC

Kromschröder Edition 0.07 L, N, E SS LC AI BUS..B for ROFIBUS-D The bus system transfers the control signals for starting, resetting and for controlling the air valve from the control system to the..b. In the opposite direction it sends operating status, the level of the flame signals and the current program status...b BUS ROFIBUS-D..B..B BUS BUS Control signals that are relevant for safety, such as the safety interlocks, purge (optional) and digital input, are transferred independently of the bus communication by separate cables...d 9 4 STW >70 C L..D 9 4..D: High temperature equipment Indirect flame control using the temperature. During the start-up process, as long as the wall temperature is below auto ignition temperature the flame must be controlled by conventional methods. When the working temperature has exceeded 70 C, the safety temperature monitor (STW) takes over the indirect flame control. Technical data Mains voltage: 30 V AC, -/+0%, 0/0 Hz, V AC, -/+0%, 0/0 Hz, for grounded and ungrounded mains. Voltage to inputs and valves = mains voltage. Output current: max. A per output, but total current for valves and ignition transformer max.. A. Operation and fault signalling contacts: Dry contact, max. A, 4 V, not fused internally. Flame control: sensor voltage approx. 30 V AC, sensor current > μa. Length of sensor cable: max. 0 m (4 ft). Fuse in unit: F: 3. A, slow-acting, H pursuant to IEC 7-/, F3: 3. A, slow-acting, H pursuant to IEC 7-/. Ambient temperature: -0 to +0 C (-4 to +40 F), climate: no condensation permitted. Enclosure: I 4 pursuant to IEC 9. Weight: Approx. kg ( lb) depending on version. BCU..B External fuse: A per zone. Certification The burner control unit is designed for applications pursuant to the Machinery Directive (98/37/EC). EC type-tested and certified pursuant to Gas Appliances Directive (90/39/ EC) in conjunction with EN 98 Low Voltage Directive (73/3/EEC) in conjunction with EN 0730 Electromagnetic Compatibility Directive (89/33/EEC) AGA Certified under No. 478 FM BCU..T is FM approved. Standard: Factory Mutual Research Standard 70: June 997 Suitable for applications pursuant to NFA 8 rofibus User Organisation BCU..B UO = ROFIBUS User Organisation, Certificate No. Z 009 pursuant to EN 070-, -3

Kromschröder Edition 0.07 Selection -3 - -0 /-3 /- / / L * * * W R * * 3* 8* GB * D* D3* S 3** / 3** U* C* B* /* ) ) Type = BCU st safety time on startup: t SA [s] = 3; ; 0 nd safety time on startup: t SA [s] = 3; Safety time during operation: t SB [s] = ; Air valve control = L Low fire over run time [s] = *; *; * Mains voltage 30 V AC, -/+0%, 0/0 Hz = W V AC, -/+0%, 0/0 Hz = R Ignition transformer TZI -/00 = * TZI 7-/0 = * TZI 7,-/00 = 3* TZI 7,-0/33 = 8* Front film in English (with additional stickers in D, F, I, NL, E) = GB Industrial plug connector = * Digital input to interrupt the flame monitoring...... for intermittent operation = D*... for continuous operation = D3* Number of pilot burner start-up attempts = S 3** Number of main burner start-up attempts = / 3** reparation for UV sensor for continuous operation UVD = U* Additional signal distribution = C* For ROFIBUS-D = B* 9-pin D-Sub bus plug connector, I 4 = /* * If none, this specification is omitted. ** If start-up attempt, this specification is omitted. ) Not in conjunction with ROFIBUS-D = B = standard, = available. Order example -/-3/LW3GBC Detailed information on this product www.docuthek.com Contact www.kromschroeder.com Sales Elster Kromschröder GmbH ostfach 809 4908 Osnabrück Strotheweg 4904 Lotte (Büren) Germany T +49 4 4-0 F +49 4 4-370 info@kromschroeder.com www.elster.com www.kromschroeder.com Kromschröder, a product brand of the Elster Group We reserve the right to make technical modifications in the interests of progress. Copyright 007 Elster Group All rights reserved. 03079 F.T. 0.07.000