HYC-950L. Medical refrigerator M.R.C LTD. OFFICES: HAGAVISH 3, HOLON P.O.B. 111, HOLON 58100, ISRAEL TEL: FAX:

Similar documents
INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:

Medical Refrigerator

Medical Refrigerator DW-25H SERIES

Instruction Manual. Chest Freezer Model: CF.142L

Refrigerator - Freezer

PDA20DX Air Purifying Dehumdifier Manual


Service Manual. Solar Direct Drive Vaccine refrigerator. Haier Medical and Laboratory Products Co,.Ltd. Model:HTC-60H & HTCD-160.

COMPACT REFRIGERATOR DRY ERASE SINGLEDOOR. User manual KSTRC24CBP KSTRC24CBU MODEL:

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

ULTRA LOW TEMPERATURE FREEZER. User Manual

Service Manual. Pharmacy Refrigerator(2~8 ) Model:HYC-68/68A/118/118A. Picture:

EVAKOOL ELITE - UPRIGHT FRIDGE FREEZERS OPERATING MANUAL

Operating Instructions

1.1 Setup Installation

Refrigerator User s Manual MODEL:FC420MS

-86 Ultra Low Temperature Freezer

Instruction Manual Refrigerator-freezer

EVAKOOL RV25, RV35, RV62, RV82 DC Compressor Portable Fridge/Freezer Operation Manual

Benefit Cabinets. Performance. Efficiency

Benefit Cabinets. Performance. Efficiency

Haier Medical and Laboratory Co., Ltd.

TM585. Refrigerator - Freezer Operation manual. Contents

HOUSEHOLD FREEZER 048-GM-48303/048-GM-48304/048-GM-48305

4. ALIGNMENT AND ADJUSTMENTS

WHS-65LB1/WHS-65LW1/WHS-65LSS1

Instruction Manual. Refrigerator. Model: HS-65L

After-sales Service Manual for WGG Solar Driven Vaccine Refrigerator

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Owner s Manual Super-Slim Four-Way Cassette

INSTRUCTION MANUAL. Model Number : CF-300K, CHEST FREEZER BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Service Manual. Pharmacy Refrigerator(2~8 ) Model:HYC-940/940F. Picture:

Refrigerator INSTRUCTION MANUAL W1BF17 & W1WF17

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

SJ-22G SJ-25G SJ-29G. Refrigerator - Freezer Operation manual. Contents. Refrigerant: R600a Insulation blowing gas: Cyclopentane ENGLISH

KSD-35 DR11 KUE-35 DVN11

REFRIGERATOR M E D I C A L.

User Manual. Chest Freezer ZFC26500WA

User Manual. Commercial Chest Freezer User s Manual 360CF5, 360CF8, 360CF14, 360CF18

Important Notes: Please read carefully before installing your refrigerator.

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

40KMC KMQ

MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi)

30/40/50L Rechargeable Fridge Freezer

Operating instructions Page 7. FDv 4613 / FDvb 4613 / FDv 4643 / FDvb 4643 / Fv 3613 / Fvb 3613 / Fv 3643 / Fvb 3643

REFRIGERATOR. User manual KSTRC43BB KSTRC43BW MODEL:

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

UPRIGHT FREEZER WHS-502FWEW1(E) WHS-502FWEB1(E) WHS-502FWESS1(E)

User Manual

COMMERCIAL REFRIGERATOR AND FREEZER USER S MANUAL

Owner s Manual TABLE OF CONTENTS

REFRIGERAT A OR USE DF1-15 F ridge

15,000 BTU Portable Air Conditioner

Installation & Operations Manual for. MSC-A & MSF-A Model. Display Freezers. 5/16 Rev. A

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

MULTIFUNCTION ROBTIC AUTO VACUUM CLEANER. MODEL NO.: M-788 Auto Charging With Remote Controller, Mop And UV Lamp

User Manual. Commercial Refrigerator And Freezer User s Manual

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Operating instructions Page 8. Freezer Read the operating instructions before switching on for the first time

Contents. Important Safety Instruction

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Magnetic Stirring Systems with Heat

AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Hisense Refrigerator

HR6BF170R HR6BF170B HR6BF170G

FF820 Freestanding Full Height Larder Fridge Manual for Installation, Use and Maintenance

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

BEFORE USING THE APPLIANCE

FF820 freestanding full height larder fridge Manual for Installation, Use and Maintenance

Biomedical Freezer 37 38

PORTABLE AIR CONDITIONER

Instruction Manual. Chest Freezer. Model: ACFM050ADB INSTALLATION INSTRUCTIONS. Before Using Your Freezer Remove the exterior and interior packing.

VF X Series. User Manual. SKOPE Vertical Freezer. MAN11137 Rev. 1.1 Sep VF650X

CONTENTS. Names of the parts...1. Safety warnings...2. Installation instructions...3. Operation instructions...3. Packing and moving...

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

Pharmaceutical Refrigerator Operation Manual

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

Outdoor and Indoor Electric Refrigerator Model COAR

Table of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)...

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)

INSTRUCTION MANUAL FOR Freeze Dry Systems PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

PORTABLE AIR CONDITIONER

Deep Freezer-upright

Dehumidifier User Manual. (For the series of DP40~DP70)

PORTABLE AIR CONDITIONER

Refrigerator KE T

User Manual. SKOPE Backbar, Counterline & Slimline BB, CL & CC Series. 1, 2 & 3 Door Horizontal Chillers. MAN11015 Rev. 2.0 Feb.

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

TFFR01 MANUAL PORTABAL 12/24 VOLTS DC REFRIGERATOR / FREEZER.

User Instruction &)+ 4: CFH110QB

INSTRUCTION MANUAL PORTABLE FRIDGE/FREEZER. Models: RVX-35 / RVX-45 / RVX-50 RVX-55 / RVX-65 / RVX-75

Bar Fridge USER MANUAL MB46W

MDF-DU900V. MDF-DU900VC Series. Operating Instructions. Ultra-Low Temperature Freezer MDF-DU900V MDF-DU900VC

PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set.

Portable Air-conditioner

Commodity Description

Operating Instructions Air Conditioner

Transcription:

OPERATION MANUAL FOR HYC-950L Medical refrigerator M.R.C LTD. OFFICES: HAGAVISH 3, HOLON 58817 P.O.B. 111, HOLON 58100, ISRAEL TEL: 972-3-5595252 FAX: 972-3-5594529 MRC.Ver.01-01.10

Thank you for buying a Medical refrigerator! For your personal safety and better performance of this unit, please read this Operation Manual thoroughly and save it properly for future reference. Failure to read, understand and follow the instructions in this manual may result in damage to the unit, injury to operating personnel and poor equipment performance. Always use the proper protective equipment (clothing, gloves, goggles etc.). Always follow good hygiene practices. Each individual is responsible for his or her own safety. Safe Notice Please read this manual carefully when use our machine at the first time. The one who operate blood bank refrigerator should be trained and authorizedve. The better to use the original fittings Should be check-up and maintenance to blood bank refrigerator at the stated time. Blood bank refrigerator prohibit to storing alive life, flowers and others which not be fit for the low temperature. When blood bank refrigerator working, the inner temperature is very low. So if not wear glove, Please don t touch the cover board. If the power shut off,please wait 5minutes.Can to connect again, to prevent the compressor damage.

1. Schematic Picture and Description Door heater lighter controller handle door body Castor locked This series of refrigerator is designed to store materials under low temperature condition for hospital, epidemic station, blood bank, research institute, university, biological pharmaceutical industry and gene engineering, etc. The internal temperature in cabinet can be easily adjusted through keys in control panel. All operations are convenient and reliable.

2 Pre-Installation How to transport:pick up the unit from the bottom of tank and a slant plane within 45 is acceptable. All transportation should be carefully. Remove all wrappers. Check accessories and documents according to package list. Clean the unit thoroughly before any operation. Installing location: Do not position the unit in direct sunlight or near heating diffusers, radiators, or other sources of heat. The ambient temperature should be limited from 18-28. Or else should open the air-condition A minimum 30cm space on the sides, rear and top should be provided for better air circulation and heat discharge. Location where is too cold and place with high humidity or can be easily splashed by water are forbidden. Safety Introduction 1 2 3 Power supply:this freezer is designed operating under 220V/50HZ AC power supply. The unit can normally start under the voltage varying from 198V to 242V. Must provide one single exclusive plug receptacle with credible grounding to unit. Don t lengthen the line randomly. If you need, Please use 2.5mm2 copper line,you should keep 4mm2 line to connect the electrical outlet. Inflammable and explosive materials, as well as high corrosive acid and alkali must be strictly prohibited in cabinet. 4 Keep the key properly avoiding the children take it to open the back door which may result in unexpected injury. 5 Keep the lamp off in use for saving energy sources and stabilization temperature in cabinet.

The machine working condition: The environment temperature:18~28 The relative humidity: 80% No strong shake and causticity gas around. No sunshine and other cold/hot power effect. 3 Operation Direction 3.1 Function Introduction for Display Panel 1. with unit under normal running condition and display different hint string under 4.2 set condition: (Refer follows for details) 2. Comp RUN:when compressor running, will light. 3.UP TEMP:for up room sensor temperature 4. DOWN TEMP:for down room sensor temperature 5. SYSTEM ALARM:when system abnormal, will alarm 6. DOOR OPEN:when door open more than one minute, will alarm *PRINT,When have printer, will work normally. 8. Mute: when alarm, please press MUTE, will keep alarm sound as mute. 9. Power failure: when power cut, will alarm.

10. BAT LOW:when printer battery low, will alarm 11. RS485:for remote alarm. 12. : Function adjustment pads 13. SET : Press this key to set the function adjustment parameter;

3.2 First Use 1. Connect the power supply and switch the on-off on the back of freezer working status; 2. Set temperature: the default temperature is set as 4 in factory. Please don t set any other temperature value. 3. LTL : When the actual temperature is lower 2 than the low temperature limit (LTL) setting, The code is LO 4. HTL : When the actual temperature is higher 7 than the low temperature limit (LTL) setting, The code is HI. (During the initial start-up, a HTL alarm is normal operation. After the temperature is stabilized and the HTL alarm stops you can put goods in your freezer); 5. upper Probe: show the upper cabinet temperature. 6. Lower probe: show the lower cabinet temperature. 7. Interior light 8. Sensor failure:any sensor temperature or 50,Show E1,SYSTEM ERROR will light. 9. When the rechargeable battery existences, when the power source supply disruption, the screen still lightened, showed the real-time cabinet temperature, recorded the number of door opening, LTL and HTL alarm. But the ventilator, the lamp and the refrigeration system does not work. (If the freezer has not been used for long time, the battery does not have electric quantity, it is normal that the window have no display. When freezer power source puts through, electrification completes automatically.) please close the power switch on the back of the box when the power cut for a long time( longer than three hours), otherwise the electric quantity loses and affects the battery service life!

3.3 Functions Setting 1.Time set:press SET,Will show time set. N07 mean year 2007,then press or 1 time to add or down the time(range from 01-99),,SET confirmed and then show Y01, mean month 01,range from 01-12, Analogy like date R01,range from 01~29, S01 mean time 01, range from 01-12, F01 mean minute, range from 00~60,After Confirmed please back off. 2. Auto print: Press the Print key, the system switches to auto print mode. Now AUTO displays in the LCD window and the print indictor lamp changes into normally bright. Under this mode press the print key of printer to automatically print recorded data. All data are printed per 5 miniatures with a format as Year, Month, Day, Time, temperature. When the print finishes, the buzzer buzzes for 5 seconds, then the system exits the print mode. To cancel print midway, press Print again. 3. Manual print Press Print twice within 3 seconds, the system switches to manual print mode. Now the display window shows ----1 and the print indicator lights. Then press the print key of printer to print the current recorded data. Press once to print the data of previous day and the display window shows ----2. Similarly, the recorded data of others days can be printed manually. All data are printed at an interval of 5 miniatures in a format as Year, Moth, Day, Time, Temperature. When the print completes, the buzzer buzzes for 5 seconds, then the system exits the print mode. To cancel print midway, press Print again. 4. Set work temperature: Press the Set key,the Numeral tube display the SET,and press the SET again, The tube show the current temperature,use to adjust. At the course of setting, The Numeral tube glinting,press the SET to make the data be effective, and the tube back to the normal status. If 15seconds you haven t pressed the SET, The operation is invalidation.,the system wrong as the last fixed data.

Notice:with logo should fix the part and function. Please don t place the goods to wall up the fan wind hole,or else will effect the chamber temperature. 4. Defrost Maintenance 1. There will be some frost on the surfaces of chamber for a long time running which may decrease the performance of freezer. If the thickness of frost is more than 10mm, some defrost operations are recommended. 2.Cut off the power,open the door,and move the goods to shade. 3. Use shovel to clean the surface frost. 4.To quicken the process of defrost,you can put the 50 water container in the freezer. 5. Note:Any electric heater, metal tool or edge tool CAN NOT be used during defrost operation. 6. Then to clean the water with dry cloth, Block the drain lid. 7. Connect the power supply after defrost is completed to run your freezer. 8. To put the goods in the freezer after finish all steps. 9. Can not put the heavy goods in the freezer, prevent to press the body. 10.Should clean the freezer at regular times.(for safe,please draw the power pin at first) 11.Use the soft and warm cloth to clean the freezer surface and inner. 12. If dirty serious,please use the scour to wipe,then clean with soft cloth. 13..Once the freezer running,the best continuous to use. DO NOT sprinkle water on the faces of cabinets, which may decrease insulating property of electric parts and rust metal parts. DO NOT use hot water, corrosive cleanser and organic solvent! Note:Prohibit the children to playing games around the freezer. Environment Temperature: -40~+55, Relative humidity: 10%~ %~90%.

5. Service after sale Some unexpected failures may arise during running. Please pay attention to the running status of your ULT freezer. If any exceptional case arises, please check and solve it according to the following introductions. If the problem is not solved well, please contact our service center for details. Problem Possible Cause Power outage has occurred. ULT freezer does not operate The plug is bad or not securely plugged-in. Fuse is blown. Voltage is too low or too high. Compressor does not work Power in control panel is off. Temperature setting is wrong. Frost in inner wall is too thick Temperature is higher than setting The door is not closed properly or is opened too frequently. Overfull materials are put into chamber. Ambient temperature is too high. Too great noise Freezer is not leveled well. Freezer leans upon the wall. Below are normal operation: 1 2 There are some light clashes when the compressor starts up and stops. During rainy and watery season some frost may accumulate on the surfaces of cabinets. Please clean it with dry rag. DO NOT open the door twice within 5 miniatures. This may lead the hot air into the interior of freezer and the door may be difficult to open because of a negative pressure due to a sharp decrease of temperature of this part air.

6 The mainly function 6.1 The mainly technical parameter Model HYC-950L The facility safe types I Kind B Type Climatic type 10~30 Input power(w) 700 Storing temperature 2~10 Refrigeration R134a Valid capacity(l) 950 Size ( depth width height)(mm) 1200 740 1920 Rating vlotage(v~) 220 Rating frequency(hz) 50 6.2 The encasement list Operation Defrost Item Key Manual shovel Qty 1 2 1 Circuit Diagram All technical parameters and circuit diagram in nameplate are final ones for your units.