RA 2000 Series RA 15/6T & TB Conversion Valve

Similar documents
RA15/6T & TB Conversion Valve

Thermostatic Radiator Valves (Caleffi)

RA2000 Thermostatic Radiator Valves

CATALOG HD.CAT Danfoss Hydronic Comfort Controls MAKING MODERN LIVING POSSIBLE

Radiator Valve Program

FHM-Cx Mixing Shunts for Floor Heating

FHM-Cx Mixing Shunts for Floor Heating

RA2000 Commercial TRVs

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

Temperature control of individual floor-heated rooms or mixed floor-heating/radiator systems

caleffi hydronic valves page 1 of 12

Mikrotherm. Manual Radiator Valves With presetting

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

Data sheet Thermostatic sensors type RA 2000

1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems.

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Temperature controller for steam (PN 25) AVT / VGS - external thread

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:

Partner Valve/High Quality Ball Valve LENO MSV-S

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

Control valves for floor heating systems. Floor Heating Manifolds

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Thermostatic valves with radiator connection systems

Automatic balancing valves ASV-PV (new generation) DN 32-50

Flush individual room control for floor heating systems

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Danfoss prefabricated floorheatingunit Type FH-G/FH-GS/FH-GR/FH-GRS

Thermostatic valve bodies

We have replacements! Introducing the NEW Macon Controls EVO, VAO/VAC and EVO-Z

ProRadiant Controls, Valves and Actuators

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

Thermostatic valve bodies

13-1. Temperature Regulator

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Radiator valve inserts

Convertible radiator valve for one-pipe systems, centre distance 35 mm

Multilux 4-Eclipse-Set

SECTION METERS AND GAGES FOR PLUMBING PIPING

WAL-RICH CORPORATION SINCE 1950

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

V2461, V2471 Verafix-VK PRE-SETTABLE H-BLOCK FOR COMPACT RADIATORS

ROTARY VANE VACUUM PUMPS Exploded View DuraVane Rotary Vane Pumps Oil-Lubricated RVL301HH

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

3 years payback time. Millions of reasons to choose the best.

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

Hydronic Separator. Hydro Separator. Hydro Separator. 548 tech brochure Hydro Separator ASME. tech brochure 01076

INSTALLATION INSTRUCTIONS

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Thermostatic mixing valves with replaceable cartridge for centralized systems

Instructions. Certifications Chrome 2-handle Chrome 3-handle 10-B83-WCH-AD Chrome 3-handle 10-B82-WCH-AD Chrome 2-handle

Three-way reversing valve

Commercial Product Selection Guide

Pushbutton Switches. Nylon. Specifications. Heavy Duty, Metal Plunger. Specifications S13 S12

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Series 1140 and 1141 Temperature Regulators

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

AVTI Multifunctional self - acting controller

Section - A. Radiator Valves

Table of Contents. Installation, Operation, and Maintenance Manual ELBPxx

Domestic Product Selection Guide

Tuzio Milano Towel Warmer

When ordering, please state type and code number. Max. Type - Capillary sensor of tube temp. charge length. C m

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

manifold, for radiators

THERMOSTATS THERMOSTATS HEATING AND COOLING

THERMOSTATIC MIXING VALVES FOR CONDENSATION PREVENTION

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

Installation Guide. BasicPlus 2 WT-DR & WT-PR Room Thermostats

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

General Characteristics SM185S3QC. Dimensions. Terminal box. Electrical Characteristics. Recommended Installation torques

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

product overview ProControl

Thermostatic mixing valves with interchangeable cartridges

TK-5001, Pneumatic Room Thermostats General Instructions GENERAL INFORMATION INSTALLATION

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Standard. thermostatic valve body without presetting

Roth fixed-value control set with high-efficiency pump

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Transcription:

RA 2000 Series RA 15/6T & TB Conversion Valve Applications: RA15/6T Internal bypass allowing for series piping to the radiators/baseboards. This series piping provides continuous flow but the supply water temperature will decrease. RA15/6TB A conventional two-pipe system where each radiator/baseboard is supplied. A traditional supply and return manifold can be utilized. The RA 15/6T and TB is a special conversion valve that allows a single connection point-at the side of the radiator- to serve as both the supply & return for a hot water based system. An example of its application is the transformation of a 1-pipe steam system into a hot water based system. There are two versions to this valve: With the installation of the RA 15/6T and TB valves any RA2000 thermostatic operator or TWA electronic actuator can be mounted, providing individual temperature regulation and controlled comfort for the room. Features: Compact design Minimized installation area Thermostatic operator or electric actuator control of valve Single entry valve connection to radiator Valve assembly for 1-pipe steam conversion to hot water Alternative method of piping for fin tube or baseboard addition Converted 1-pipe steam radiator Fin tube baseboard, system extension Alternative piping for baseboard application, piped as a conventional 2-pipe system VDTQZ222 Danfoss 03/14 1

RA 2000 Series RA 15/6T & TB Conversion Valve Applications (Cont.): Radiator Thermostatic Operators Manifold 24Vac, Electric Actuator RA 15/6T piped to a manifold for individual distribution 24Vac, Electric Actuator Fin tube baseboard Thermostatic Operator Alternative piping for baseboard application piped as a diverter system Ordering Information: Valve Size Model Cv Connection 013G3270 013G3268 1/2 RA15/6T 2.34 1 Rp 1/2 int. thread 2 G 3/4 ext. thread 3 013G3215 RA15/6TB 1.17 Rp 1/2 int. thread 2 1 Cv = Cv bypass + Cv radiator. Max flow through radiator, approx. 35%. 2 Rp 1/2 int. thread are straight thread, non-npt thread. 3 G 3/4 ext. threading require fittings. 2 VDTQZ222 Danfoss 03/14

RA 2000 SERIES RA 15/6T & TB Conversion Valve Fittings & Spare Parts: Fittings Description 013G4116 1/2 Copper compression fitting for RA 15/6T & TB, 2 pcs required, use with 013G3215 & 013G3270 only 013U0476 1/2 M. NPT tailpiece for RA 15/6T, 2 pcs required, use with 013G3268 only 013U8608 1/2 F. solder tailpiece for RA 15/6T, 2 pcs required, use with 013G3268 only 013U0496 1/2 Union nut for RA 15/6T, 2 pcs required, use with 013G3268 only Spare Parts Description 013G0290 Packing gland 013G1350 Angle Adaptor RA2000 Thermostatic Operator: Operator Description Sensor Capillary 013G8250 Standard valve mounted dial and sensor Built-in - 013G8252 Standard valve mounted dial with remote sensor Remote 6 013G8240 Tamper resistance valve mounted dial and sensor Built-in - 013G2922 Tamper resistant valve mounted dial with remote sensor Remote 6 013G8562 013G8562 Combined remote mounted dial and sensor Built-in 6 16 013G8562 26 013G8564 Seperate remote mounted dial and sensor Remote 6 + 6 VDTQZ222 Danfoss 03/14 3

RA 2000 Series RA 15/6T & TB Conversion Valve Electronic Thermowax Actuators: Actuator 088H3110 088H3111 088H3114 Type Operation Actuator Position TWA-A actuator 24VAC, 2VA c/w valve position indicator ON/OFF NC NO NC, w/ end switch 082F1091 ABNM actuator 24VAC, 1.5VA requires control signal Proportional (0-10VDC) NC Specifications: Suitable applications Max. working pressure Max. differential pressure Max. test pressure Max. flow temperature Connection 1) 1-pipe steam conversion to hot water systems 2) Hot water fin tube or baseboard applications RA 15/6T Rp 1/2 int. thread 1 G 3/4 ext. thread 2 145 psi (10 bar) 8.7 psi (0.6 bar) 232 psi (16 bar) 248 º F (120 º C) RA 15/6TB Rp 1/2 int. thread 1 Design and Function: The RA 15/6T and TB valves are a unique design assembly that offer control of radiators or fin tube baseboard through a thermostatic operator or electronic actuator control. The 1/2 connection to the radiator allows supply hot water to enter and through the same connection allows return water to leave. This circulation through the radiator is achieved through the 8 straight flow tube which is inserted into the radiator. The flow tube receives the return water, while hot water is delivered through the radiator connection. If the length of the radiator is long, the flow tube can be extended by soldering on a 1/4 copper tube to the end of the flow tube. The extension to the flow tube results in a pressure drop of 0.02 FOH/in. The extension will allow cooler water furthest from the connection to leave the radiator and be replaced by hot water. The valve body is also an ideal alternative in the conversion of a one pipe steam system into a hot water system. In considering the conversion valve for a 1-pipe steam system, verify that across the top of the radiator are push nipples. The push nipples located at the top of the radiator provides circulation for hot water within the radiator. Unfortunately, if the radiator lacks push nipples at the top, the effectiveness of the conversion valve is greatly reduced. Prior to installation of the conversion valve, the potential 1-pipe steam radiator should be pressure tested to ensure it will be capable of handling the increased pressure from a hot water system. In addition the radiator should also be flushed to remove any debris from within that could potentially clog the valve or other components within the system. 4 VDTQZ222 Danfoss 03/14

RA 2000 SERIES RA 15/6T & TB Conversion Valve Design and Function (Cont.): RA 15/6TB RA 15/6T Construction: 1- Pressure pin 2- O-ring gland seal 3- Valve cone 4- Valve body 5- Flow tube Materials in contact with water Pipe supporting bushing PP O-ring EPDM Valve cone NBR rubber Pressure pin Chrome steel Lock washer Tin alloy Valve body and other Ms 58 brass metal parts Dimensions inches (mm): VDTQZ222 Danfoss 03/14 5

RA 2000 Series RA 15/6T & TB Conversion Valve Typical Specification: The valve shall be nickel plated and capable of delivering supply hot water and receiving return water through a single connection to the radiator. An incorporated flow tube shall receive the return from the radiator and be capable of extending its length. The valve shall be used on a closed loop water based system and have the option of a bypass function. The mountable control for the valve shall have the option of either a non-electric thermostatic operator or a 24V electric actuator. The thermostatic operator shall be available in either a valve or wall mounted dial operator. The valve mounted dial shall be a vapor charged operator and installed via snap-action mechanism or Allen key. The brass valve body shall have a packing gland assembly capable of replacement while the system is in operation. Danfoss can accept no responsibility for possible errors in printed materials and reserves the right to alter its products without notice. All trademarks in this material are property of the respective companies. Danfoss and Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Danfoss Inc. Toronto, ON Toll Free: 866-375-HVAC (4822) Tel.: 905-285-2050, Fax: 905-285-2055 www.na.heating.danfoss.com Danfoss Inc. Baltimore, MD Toll Free: 866-375-HVAC (4822) Tel.: 443-512-0266, Fax: 443-512-0270 www.na.heating.danfoss.com 6 VDTQZ222 Danfoss 03/14