General Specifications

Similar documents
General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

Technical Information

Technical Information

Technical Information

General Specifications

General Specifications

General Specifications

CPS V Cabinet Power System

Model 144H. Product Data Sheet , Rev DB February Content

Bionics Instrument. Alarm Handling. Gas Alarm Systems

AO Annunciator Module

General Specifications

Model 144H. Product Data Sheet , Rev DB February Content

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

General Specifications

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

AQ7275 OTDR Optical Time Domain Reflectometer

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

General Specifications

EOTec 2C32 Installation Guide

Annunciator Unit SACO 16 D1. Product Guide

APPLICATION DATA SHEET

Technical Data. Dimensions

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

AQ7275 OTDR Optical Time Domain Reflectometer

Y-Plant Alert. Alarm Annunciator and Sequence of Event Recording System. BU 04M01A02-01E-A

Annunciator unit. Application

IM 77J01H07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0

Annubar Flowmeter Series

FC724 Fire control panel

5000 Series Rack Panels

FC724 Fire control panel

Manual Isolating Barrier D461 (Revision 05)

Multi-Gas-Controller MGC2

Rosemount 752 Fieldbus Remote Indicator

15R HARDWARE INSTALLATION GUIDE

FC722 Fire control panel

Fire control panels FC726 FC726-XA

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

EC-BOS-602/616 AX Security

User s Manual YTA610 and YTA710 NEPSI Certification

Two global companies, one solution.

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

User s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

IM 77J01A07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0. Output-2 signal

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

FC2020 Fire control panel

Safety Instrumented Fire & Gas Systems

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

XC10 Extinguishing control panels

Manual Isolating Barrier D461R1 (Revision 01)

Engineering Guideline. pac- Carriers Type Universal

Vocia VACIE. Reference Guide

Fire control panel for modernization

Danfoss gas detection units

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

VACIE REFERENCE GUIDE REVISION 1.2.6

SecuriFire SecuriLine extended board B5-DXI2

FC723 Fire control panel

General Specifications

E3 Series Broadband System

On the job around the clock 24/7: Fire detection systems

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1150

PROFIBUS Optical Bus Terminal (OBT) SIMATIC NET. PG/PC - PROFIBUS PROFIBUS Optical Bus Terminal (OBT) Introduction 1. Components of the product

Remote Booster Power Supplies

Operating Instructions Edition 02/2007

Interfacing with the ADAM Module

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

SIMATRIX NEO Modular Video Matrix

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

E3 Series Broadband System

Architectural and Engineering Specification for a. Flash / Flare

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E

Fiber Optic Cable Fence Disturbance Sensor

Integrated redundant fieldbus power for FBM228 Foundation fieldbus modules High-density, compact design Fully isolated

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Control Panels and Fire Detection Equipment

Proservo NMS5- / NMS7-

Fire control panel detect 3004 plus and accessories

Innovative protection that combines power and flexibility

Proven Technology for Safety Instrumentation Systems

Technical Data. Dimensions

Transcription:

General Specifications Models AFV30S, AFV30D Field Control Unit Duplexed Field Control Unit (for Vnet/IP and FIO, 19-inch Rack Mountable Type) GENERAL This GS covers the hardware specifications of the Field Control Unit (FCU) which is the core of the control function of the Field Control Station (FCS). Attention: These products are subject to the Export Administration Regulations (EAR) by the United States Department of Commerce, Bureau of Industry and Security (BIS). It is not possible to export or reexport these products to Iran, Cuba, North Korea, Syria, and Sudan. HARDWARE SPECIFICATIONS For the installation specifications and the environmental conditions common to the systems, refer to Integrated Production Control System CENTUM VP System Overview (Vnet/IP Edition) (GS 33K01A10-50E). Processor VR5532 (350 MHz) l Main Memory Capacity 128 MB l Memory Protection During Power Failure Battery Battery Back-up for Main Memory: Max. 72 hours Battery Recharge Time: Min. 48 hours l FCU Status Contact Output 2 terminals (NC, C) Contact Points open during FCU failure Contact Rating: 30 V DC, max. 0.3 A Note: When option code /HKU is specified, a FCU fault contact is output from the House Keeping Unit (HKU). l Communication Interface Vnet/IP Interface: For more details, refer to "Integrated Prodction Control Systrm CENTUM VP System Overview (Vnet/IP Edition)" (GS 33K01A10-50E) l HKU Interface (Option) When option code /HKU is specified, a FCU fault contact is output from the HKU. Also, the environmental conditions of the cabinet connected via the HK bus and optical ESB bus can be monitored and the operating status of the HKU can be displayed on the HIS. System alarms can also be displayed. [19-inch Rack Mountable Type FCU] F01E.ai l No. of s Connectable Max. 13/FCU The total number of s (ANB10 ) and Optical s (ANB11 ) that can be connected to FCU are 13 or less. The ER Bus Node Unit (ANR10 ) cannot be connected. The Control function for field control station (LFS1700) allows up to 3, and can be expanded as follows by adding the Node Expansion Package (LFS1750). LFS1750-V1: Max. 9/FCU LFS1750-V2: Max. 13/FCU To connect a node unit to the FCU, a Expansion License (option code: /NDEL) is required for the node unit. l Module Configuration Power Supply Module (PW481 or PW482 or PW484): 2 modules for dual-redundant configuration Processor Module (CP461): 2 modules for dualredundant configuration I/O Module (*1): Max. 8 *1: Non-standard component. Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5634 Fax.: 81-422-52-9802 Copyright Aug. 2011(YK) 6th Edition Sep. 1, 2014(YK)

l Installation Restrictions To connect the (ANB10 ) or Optical (ANB11 ) to the FCU, install the Coupler Module (EC401 or EC402) in slots 7 and 8 of the FCU. For the dual-redundant configuration of the processor modules, EC401 or EC402 must be installed in both slot 7 and slot 8. In case has a single configuration, EC401 or EC402 must be installed in slot 7 and keep slot 8 empty. To install the optical ESB bus node unit and ESB bus node unit in a remote location, use the Optical ESB Bus Repeater Master Module (ANT401 or ANT411) to connect them with an optical fiber cable. To install the optical ESB bus repeater master module in the FCU, install a pair of modules in slots 1 to 6 in order from right to left according to the number of branches. In a single configuration, install the individual modules in slots 1, 3, and 5 in order from right to left. For details, see the Optical Repeater Module (GS 33K50F51-50E/GS 33K50F52-50E). For the limitations and precautions for installing I/O modules, see FIO System Overview (for Vnet/IP) (GS 33K50F10-50E). l Power Supply Voltage: 100-120 V AC, Frequency: 50/60 Hz Voltage: 220-240 V AC, Frequency: 50/60 Hz Voltage: 24 V DC Specify with the Suffix Code. l Power Consumption 100-120 V AC: 200 VA 220-240 V AC: 230 VA 24 V DC: 5.5 A l Weight Approx. 7 kg (AFV30S) Approx. 8 kg (AFV30D) l Mounting 19-inch Rack Mounting: Rack mount (M5x8 screws) Insulation bush (accessory) l Connection Power Supply: M4 screw terminal connection Grounding: M4 screw terminal connection FCU Status Contact Output: M4 screw terminal connection Network: Connect UTP cable (CAT5e or better) to Layer 2 switch. 2 l Regulatory Compliance For the detailed information of following standards, see Integrated Production Control System CENTUM VP System Overview (for Vnet/IP) (GS 33K01A10-50E). Safety Standards [CSA] (for 100-120 V AC power supply) [CE Marking] [EAC Marking] EMC Conformity Standards [CE Marking] [RCM] (for 220-240 V AC and 24 V DC power supply) [KC Marking] [EAC Marking] Standards for Hazardous Location Equipment [FM Non-Incendive] [Type n] (for 24 Sep. 1, 2014-00

TM1 READY FUSE RL1 CN1 (PSU-L) TM2 100-120V AC CN2 (PSU-R) <<Contents>> <<Index>> 3 l System Configuration This is a configuration example of an FCU and node units, and an ESB bus (including optical ESB bus) that connects them. Vnet/IP FCU: Field Control Unit ESB bus Optical cable Optical ESB bus I/O signal connection Figure System Configuration F01E.ai LIMITATIONS OF INSTALLATION AND NOTICES FOR INSTALLATION For installing I/O modules in AFV30S or AFV30D, the quantity and allocation are limited. Also, when installing a node unit to the dedicated cabinet, there are limitations of installation under the ambient operating temperature conditions. When modules with built-in barriers are installed in AFV30, an insulating partition kit (Part No. T9083ND) must be installed. For details, please refer to FIO System Overview (for Vnet/IP) (GS 33K50F10-50E) and Installation Guidance (TI 33K01J10-50E). Sep. 1, 2012-00

4 EXTERNAL DIMENSIONS Unit: mm 8.75 21.3 482.6 465.1 440 207 150.6 20.4 265.9 221.3 146 44.5 31.75 5.9 Hole for mounting on a 19-inch rack 8 holes for M5 screws When specifying option code /HKU F03.ai SOFTWARE REQUIREMENT For AFV30S and AFV30D, the Control Function for Field Control Station (LFS1700) is required. Specify this control function with the suffix code. The number of the connectable node units and the application capacity can be expanded if the Node Expansion Package (LFS1750) is purchased. For the specifications of LFS1700 and LFS1750, refer to GS 33K15C10-50E. REQUIREMENTS FOR USING SEM (Sequence of Events Manager) For using SEM, the hardware requires some conditions. For details, refer to "SEM Sequence of Events Manager (for Vnet/IP and FIO)" (GS 33K30D10-50E). STANDARD ACCESSORIES The FCU is delivered with the following standard accessories. Parts Names Parts Numbers Description Quantity Remarks Insulating bush S9049PM 8 Accessory Aug. 19, 2011-00

5 MODELS AND SUFFIX CODES Field Control Unit Description Model AFV30S Field Control Unit (for Vnet/IP and FIO, 19-inch Rack Mountable) Suffix Option -S Standard type 3 Vnet/IP, single power supply 4 Vnet/IP, dual-redundant power supply 1 Always 1 1 100-120 V AC power supply (*1) 2 220-240 V AC power supply (*1) 4 24 V DC power supply (*1) 5 Basic type with no explosion protection 6 With ISA Standard G3 option and no explosion protection E Basic type with explosion protection F With ISA Standard G3 option and explosion protection LFS1700 Control function for field control station 1 (for AFV30 /AFV40, Vnet/IP and FIO) <for CP461> /HKU With HKU interface (*2) /ATDOC Explosion Protection Manual (*3) Note: These products are subject to the Export Administration Regulations (EAR) by the United States Department of Commerce, Bureau of Industry and Security (BIS). It is not possible to export or reexport these products to Iran, Cuba, North Korea, Syria, and Sudan. *1: To meet the safety standards and EMC standards, the unit must be installed in a keyed metallic cabinet. *2: When used in combination with ACUKT, specify this option code /HKU. *3: Select the option code /ATDOC to follow the ATEX Directive for use in potentially explosive atmospheres. Duplexed Field Control Unit Description Model AFV30D Duplexed Field Control Unit (for Vnet/IP and FIO, 19-inch Rack Mountable) Suffix Option -S Standard type 4 Vnet/IP, dual-redundant power supply 1 Always 1 1 100-120 V AC power supply (*1) 2 220-240 V AC power supply (*1) 4 24 V DC power supply (*1) 5 Basic type with no explosion protection 6 With ISA Standard G3 option and no explosion protection E Basic type with explosion protection F With ISA Standard G3 option and explosion protection LFS1700 Control function for field control station 1 (for AFV30 /AFV40, Vnet/IP and FIO) <for CP461> /HKU With HKU interface (*2) /ATDOC Explosion Protection Manual (*3) Note: These products are subject to the Export Administration Regulations (EAR) by the United States Department of Commerce, Bureau of Industry and Security (BIS). It is not possible to export or reexport these products to Iran, Cuba, North Korea, Syria, and Sudan. *1: To meet the safety standards and EMC standards, the unit must be installed in a keyed metallic cabinet. *2: When used in combination with ACUKT, specify this option code /HKU. *3: Select the option code /ATDOC to follow the ATEX Directive for use in potentially explosive atmospheres. ORDERING INFORMATION Specify model and suffix codes. For selecting the right products for explosion protection, please refer to TI 33Q01J30-01E without fail. TRADEMARK CENTUM and Vnet/IP are registered trademarks of Yokogawa Electric Corporation. Other company and product names appearing in this document are trademarks or registered trademarks of their respective holders. Subject to change without notice. Apr. 1, 2013-00