ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

Similar documents
NANEO EMC-M WALL-HUNG GAS CONDENSING BOILERS

PMC-M WALL-HUNG GAS CONDENSING BOILERS

WALL-HUNG GAS CONDENSING BOILERS MCR-P 24/28 BIC. HOMOLOGATION B 23P - C 13x - C 33x - C 93x -C 53 - C 43x - C 83x *

NANEO EMC-M EASYLIFE WALL-HUNG GAS CONDENSING BOILERS

MPX 24/28 MI Compact MPX 28/33 MI Compact CONDITIONS OF USE HOMOLOGATION. B 23 - C 13x - C 33x - C 53x - C 93x - C 83x* B 23p - B 33 - C 43x

WHE 2.24 / WHE 2.24 FF

FLOOR STANDING GAS CONDENSING BOILERS CONDITION OF USE CLASSIFICATION

4FLOOR-STANDING GAS CONDENSING BOILERS

FLOOR-STANDING GAS CONDENSING BOILERS FROM 3.4 TO 35.9KW. by 160 litre enamelled calorifier with coil placed CONDITIONS OF USE HOMOLOGATION

GT 220 PROJECT CAST IRON FLOOR-STANDING FUEL OIL-/GAS-FIRED BOILERS

GT 220 CAST IRON FLOOR-STANDING FUEL OIL- / GAS-FIRED BOILERS

GTU C 220 FUEL OIL CONDENSING BOILERS

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

DIEMATIC VM isystem WALL-MOUNTED CONTROL SYSTEM. DIMENSIONS Length: 320 mm Height: 260 mm Depth: 130 mm. POWER SUPPLY 230 V, 50 Hz, 6 A

1 VICTRIX ZEUS Superior kw I features

8FUEL OIL CONDENSING BOILERS

PRODUCT CATALOGUE

HPI REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

VICTRIX Superior kw Export VICTRIX Superior kw X Export

SPECIFICATIONS - NIKE

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

GT 120 >> >> >> << >> Sustainable Comfort. Longlasting comfort

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

CALORA TOWER GAS 15S EX CALORA TOWER GAS 25S EX CALORA TOWER GAS 35S EX

ADVANCE EASYLIFE PROJECT

Vivadens. Wall-hung gas condensing boilers MCR 24/28 BIC. User Guide B

EMC-M 24 EMC-M 24/28 MI EMC-M 30/35 MI EMC-M 34/39 MI

Range GT GTU C GT 220

Wood-burning boiler CBB. User Guide E

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

ALEZIO REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER CONDITIONS OF USE

ACCUMULATION OF EUROPEAN CLASS

DTG Eco / V130

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

BSC...E - BSP...E - BESC...E

Remeha. Fuel oil/gas boilers P 420. Installation and Service Manual

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

Power X High Power Condensing Wall-Hung Boilers

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

Power X High Power Condensing Wall-Hung Boilers

FLOOR STANDING GAS CONDENSING BOILERS HOMOLOGATION C 630- ECO: B 23 - B 23P - C 33 - C 53 - C 63 - C 83 - C 93

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

Ciao Green Condensing Wall-Hung Boilers

Modulens G >> >> >> Condensing in excellence mode

>> >> >> High technology with oil. High performance modulating burner Compact boiler design. Compatible with renewable energies. Sustainable Comfort

<< >> Condensing technology at the service of oil. Controlling energy to save money

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

WOLF GAS CONDENSING BOILERS COMFORTLINE

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

INDEPENDENT DOMESTIC CALORIFIERS

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

Exclusive Green E Condensing Wall-Hung Boilers

VELA COMPACT INSTALLATION USE AND MAINTENANCE

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

MCR-P 24 MCR-P 24/28 MI MCR-P 30/35 MI MCR-P 34/39 MI

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

ENERGY TOP. Condensing boiler solutions

C Tahiti. condensing

LIBRA DUAL INSTALLATION USE AND MAINTENANCE. Italian product. High quality IST 04 C

WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS. Efficient, economical and easy

STM Department TRAINING MODULE. : instantaneous. Version 1.0, Jan 2006

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

Seradens Super Seradens Super Plus

TAHITI CONDENSING KR 55 - KR 85

CAST IRON ATMOSPHERIC BOILERS

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

ARIES DUAL MAINTENANCE MADE IN ITALY IST 04 C

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

BORA BORA. BORA gas: the best suns THE MODELS BORA GAS ALL INNOVATION STRENGTHS

C ECO FLOOR STANDING GAS CONDENSING BOILER CONDITIONS OF USE HOMOLOGATION GAS CATEGORY

Domestic hot water tank SR130. Installation, User and Service Manual

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

TAHITI DUAL HC - HR INSTALLATION, USE AND MAINTENANCE. Italian product. High quality

DOMESTIC HOT WATER Follow operational sequence

Mikrofill Ethos Condensing combination boiler

Innovens Pro. Wall-hung gas condensing boilers MCA Installation and Service Manual A

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

SOLNEO SGC 24 SOL. User Guide. Gas fired condensing boiler C

MINORCA KC - KR - KRB 24

CITY OPEN - CITY BOX from 25 to 35 kw

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

CBX 24, 32 & 38 SBX 30

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

Mynute Green Condensing Wall-Hung Boilers

Gas Instantaneous Water Heater

High temperature air-to-water heat pumps

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

Transcription:

ZENA PLUS WALL-HUNG GAS BOILERS MSL FF: from. to 1 kw for heating only MSL FF + BMR 80 and MSL FF + SR 10: from. to 1 kw for heating and DHW produced by an 80-litre calorifier placed beside the boiler, or a 10-litre calorifier placed under the boiler MSL MI (FF): from. to 1 kw for heating and instantaneous DHW ZENA PLUS MSL 2, 1 FF, ZENA PLUS MSL 2, 28, 1 MI FF MSL 2 MI, MSL 2, 1 FF: Heating only MSL MI or MSL 2, 1 FF + BMR 80 or SR 10, heating and domestic hot water produced by an integrated or independent calorifier or instantaneous DHW Low temperature All natural gases Propane EC identification No.: MSL 2 MI: 51CO28 MSL FF: 51CO26 ZENA PLUS MSL 2, 1 FF + SR 10 ZENA PLUS MSL 2, 1 FF + BMR 80 Boilers available: - For connection to a chimney: MSL 2 MI - For horizontal or vertical forced flue connection: MSL 2, 28, 1 MI FF-MSL 2, 1 FF Fully equipped boilers, including an easy-to-use, functional electronic control panel as standard to control a direct circuit and a DHW circuit. As optional equipment, this panel can be completed with a control system offering two comfort levels: either by room temperature thermostat and/or by outside sensor. OPERATING CONDITIONS Max. operating pressure: bar Max. operating temp.: 5 C Safety thermostat: 105 C Thermostat adjustable from 0 to 85 C Protection rating: IP X5D HOMOLOGATION - MSL 2 MI: B 11BS - MSL 2, 28, 1 MI FF, MSL 2, 1 FF: C 12x - C 2x - C 2x - C 52 - C 82x - B 22 GAS CATEGORY All natural gases, adjustable to propane EASYLIFE

PRESENTATION OF THE BOILERS The MSL boilers are delivered fully assembled and factory tested. They are pre-fitted to run on natural gases and can be converted to propane using a conversion kit (optional) ; they are available for various types of connection: chimney, forced flue (FF) (see next page). The MSL 2 FF and 1 FF boilers are small-scale boilers (780 x 50 x 5 mm) for heating only, equipped as standard with a heating/dhw reversal valve allowing the connection of an independent domestic hot water calorifier, two types of calorifier are available: - 80-litre BMR 80 calorifier to be juxtaposed to the right or left of the boiler: MSL 2, 1 FF + BMR 80-10-litre SR 10 calorifier to be placed on the floor under the boiler: MSL 2, 1 FF + SR 10 The MSL 2, 28, 1 MI FF and MSL 2 MI boilers are smallscale boilers (780 x 50 x 5 mm) with production of instantaneous DHW thanks to a large stainless steel plate exchanger. An optional hydraulic connection kit to connect a solar calorifier can also be delivered for these boilers. HIGH PERFORMANCE - efficiency rating for the forced flue versions, for the chimney version; - NOx class in accordance with pr EN 27 A for the chimney version, EN 8 the forced flue versions (FF). THEIR STRONG POINTS - Primary exchanger in copper coated with aluminium silicone paint increasing its heat resistance; - Gas valve with external modulator and double safety solenoid valve; - Atmospheric burner with stainless steel burner trains; - Electronic ignition and ionisation flame check; - Digital display direct access electronic control panel used as standard to control a direct circuit and a DHW circuit (optional sensor for MSL 2, 1 FF models); Possibility of controlling circuit by adding a room temperature thermostat and/or an outside sensor (options); - Hydroblock in brass incorporating the -speed heating pump, with automatic vent, the automatic by-pass, the heating/dhw reversal valve fitted to the return, the water pressure switch, the drain cock, the disconnector, the -bar heating safety valve, the pressure gauge, the stainless steel plate exchanger and the turbine flow detector for measuring the DHW flow rate on MSL MI; - Anti-overflow thermostat on chimney version; - Extraction fan and air pressure switch on FF; - 8-litre heating expansion vessel on MSL 2 and 10-litre on MSL 28/1 ; - Wall-hanging bracket provided. MODELS AVAILABLE Boiler Connection type Model Useful output range (kw) MSL_Q0001 For heating only Forced flue MSL 2 FF MSL 1 FF.-25.-1 Chimney MSL 2 MI.-25 MSL_Q0011 MSL_Q0001 For heating and instantaneous domestic hot water Forced flue MSL 2 MI FF MSL 28 MI FF MSL MI FF.-2 10.-28.1 10.-1 MSL_Q0005 For heating and domestic hot water preparation by 80-litre calorifier positioned to the right or left of the boiler Forced flue MSL 2 FF + BMR 80 MSL 1 FF + BMR 80.-2 10.-1 MSL_Q000 For heating and domestic hot water preparation by 10-litre calorifier placed under the boiler Forced flue MSL 2 FF + SR 10 MSL 1 FF + SR 10.-2 10.-1 2

TECHNICAL SPECIFICATIONS OF THE BOILERS DESCRIPTION MSL 2, 28, 1 MI FF Model shown: MSL 2, 28, 1 MI FF Air/flue gas connection Ø 60/100 mm Air pressure switch Extractor fan Safety thermostat Heating temperature sensor Primary exchanger in copper Combustion chamber Ignition and ionisation electrode Atmospheric gas burner with stainless steel trains Gas valve Motorised heating/dhw reversal valve in brass Stainless steel plate exchanger for instantaneous DHW production (MSL MI only) -speed heating pump with air separator Drain valve bar safety valve Water pressure switch MSL_Q000A Pressure gauge Filling valve MSL 2 MI (chimney version) Flue gas nozzle Ø 120 mm Flue gas thermostat Safety thermostat Heating temperature sensor Gas valve Motorised heating/dhw reversal valve in brass Water pressure switch -speed heating pump with air separator bar safety valve Filling valve Pressure gauge Control panel in tilted position MSL_Q0008

TECHNICAL SPECIFICATIONS OF THE BOILERS TECHNICAL SPECIFICATIONS Boiler Boiler type: low temperature EC identification N : - MSL : 51CO28 - MSL FF: 51CO26 Energy used: natural gas or propane Burner: - MSL 2 MI: atmospheric without fan - MSL 2, 28, 1 MI FF, MSL 2, 1 FF: atmospheric with fan Evacuation: - MSL 2 MI: chimney - MSL FF: forced flue Minimum flow temp.: 0 C Minimum return temp.: 20 C Model MSL 2 FF 1 FF 2 MI 2 MI FF 28 MI FF 1 MI FF Nominal useful output Pn (heating and DHW mode) kw 25 1 25 25 28.1 1 Efficiency in % Pci, 100 % Pn - 70 C % 2..1 1.2 2..1.1 at load % Pn and average temp. C 0 % Pn - 0 C % 0.2 0.8 0. 0.2 0.8 0.8 Nominal water flow rate at Pn, t = 20 K m /h 1.07 1. 1.0 1.07 1.2 1. Min. useful output (heating and DHW modes) kw. 10... 10. 10. Manometric height available heating circuit mbar 250 20 250 250 20 20 Water content l 1. 1. 1. 1. 1. 1. Gas flow rate - Natural gas H m /h 2.8.52 2.78 2.8.18.52 at Pn - Propane m /h 2.0 2.5 2.0 2.0 2. 2.5 Draught required at the nozzle mbar - - 0.05 à 0.1 - - - Mass flue gas flow rate at Pn kg/h 61.2 68. 68. 61.2 61.2 68. Weight empty kg 8 8 8 0 0 Domestic hot water production Model MSL 2 MI 2 MI FF 28 MI FF 1 MI FF 2 FF + BMR 80 2 FF + SR 10 1 FF + BMR 80 1 FF + SR 10 DHW calorifier capacity l - - - - 7 122. 7 122. Exchanged output kw 2 25 28 1 25 25 1 1 Flow rate over 10 min at t = 0 K l/10 min - - - - 215 266 20 01 Flow rate per hour at t = 5 K l/h 588 612 68 762 61 61 762 762 Specific flow rate at t = 0 K (in accordance with EN 120) l/min 10.7 11.5 12.5 1.7 21.5 26.6 2 0.1 Weight empty kg 8 0 0 86 106 88 108 MSL MI (FF): DHW performance at room temp. 20 C, cold water temp. 10 C, primary hot water temp. 85 C. MSL 2 FF, MSL 1 FF: DHW performance at room temp. 20 C, cold water temp. 10 C, primary hot water temp. 80 C, storage temp. 60 C.

TECHNICAL SPECIFICATIONS OF THE BOILERS PRINCIPAL DIMENSIONS (IN MM AND INCHES) MSL 2 MI MSL FF 188 222 Ø120 1 22 22 6 780 (1) 6 780 76 166 10 76 166 10 65 65 65 65 5 1 88 2 65 65 65 65 5 5 1 88 5 MSL 2, 1 FF + BMR 80 MSL_F0001 50 MSL 2, 1 FF + SR 10 5 188 (1) 5 5 MSL_F0002 50 2 with hydraulic connection package HX 18 + HX 1 188 50 (1) 1 1 22 176,5 22 6 6 780 7 7 780 2 880 680 166 10 88 88 Ø 22 1 7 260 166 1 8 50 8 7 10 65 65 5 Ø 27 1 1 5 5 5 05 6 110 15 package HX with hydraulic connection package HX 18 + HX 1 package HX 2 10 65 65 5 8 MSL_F000 10 7 8 50 12 MSL_F000A Ø 570 Legend Heating flow G / MSL 2 MI: domestic hot water outlet G 1/2 MSL 2, 1 FF: primary calorifier flow (if one exists) G / MSL 2, 28, 1 MI FF: domestic hot water outlet G 1/2 Gas inlet G / MSL 2 MI: domestic cold water inlet G 1/2 MSL 2, 1 FF: cold water inlet (boiler filling) G 1/2 MSL 2, 28, 1 MI FF: domestic cold water inlet G 1/2 MSL 2 MI: heating return G / MSL 2, 1 FF: heating return and primary calorifier return (if one exists) G / MSL 2, 28, 1 MI FF: heating return G / Evacuation of combustion products and air inlet pipe: MSL 2 MI: Ø 120 mm MSL 2, 28, 1 MI FF: Ø 60/100 mm (1) Shown with 0 elbow delivered with the horizontal forced flue package DY 08 (optional) 5

CONTROL PANEL The control panel fitted to MSL boilers is an electronic control panel with digital display, which can be accessed directly on the boiler fascia. It is used as standard for the automatic control of a direct circuit and a DHW circuit, adapting the boiler s output to the user s actual needs thanks to temperature control by two NTC sensors. It provides antifreeze protection for both circuits below a flow temperature of 5 C. It can be completed by a control system based on the outside temperature (optional sensor) and/or a room temperature thermostat (options see below). Moreover, the control panel incorporates a complete troubleshooting system that can be viewed on the display unit, and a system to prevent gumming of the heating pump and the heating/dhw reversal valve. DHW temperature adjustment Reset button MSL_Q0002 LCD screen with display, as appropriate: - of the actual or set point temperatures - of the operating statuses - of the «error» codes Summer/Winter/ Heating Only/Stop Button Heating temperature adjustment «Eco-comfort» button CONTROL PANEL OPTIONS AD 27 AD 200 AD 10 8801Q02 8666Q120A Programmable hard-wired digital room temperature thermostat Package AD 27 Programmable wireless digital room temperature thermostat Package AD 28 Programmable hard-wired room temperature thermostat Package AD 17 Programmable wireless room temperature thermostat Package AD 200 Non-programmable room temperature thermostat Package AD 10 The programmable thermostats handle the control and weekly programming of the heating by activating the burner in accordance with the various operating modes: «Automatic» according to the programme, «Permanent» at a set temperature or «Holidays». Domestic hot water sensor - Package HX 52 The domestic hot water sensor is used to apply priority regulation to DHW production by an independent calorifier. Outside sensor - Package HX 1 The outside sensor can be used alone or in combination with the room temperature thermostats. MS_Q0005 The «wireless» versions are delivered with a receiver box to be affixed to the wall close to the boiler. The non-programmable thermostat is used to regulate the room temperature according to the instruction given by activating the burner. 8801Q00 MSL_Q0007 MSL_Q0015 Relay card - Package HX 61 Configurable relay card to connect to the control panel interface. It is equipped with two relay outputs and an ON / OFF input. 6

OTHER BOILER OPTIONS HYDRAULIC CONNECTION ACCESSORIES: FOR A NEW INSTALLATION Package to order: for MSL 2, 1 FF: Hydraulic connection kit: Package HX 18 or Complete hydraulic kit HX 18 + HX 1 (with water and gas valves) or Hydraulic connection plate: Package HX 62 HX 62 MS_Q007 MSL_Q0016 (HX 18 + HX 1) MS_Q007 MSL_Q000 HX 1 HX 18 MSL_Q001 MSL_Q012 for MSL MI (FF): Hydraulic connection kit: Package HX 20 or Complete hydraulic kit HX 20 + HX 1 (with water and gas valves) or Hydraulic connection plate: Package HX 62 HX 62 MS_Q007 MSL_Q0016 (HX 20 + HX 1) MS_Q007 MSL_Q0010A HX 1 HX 20 MSL_Q001 MSL_Q001 The HX 18 (with boiler flow/return and calorifier flow valves), HX 1 (with gas and cold water inlet valves only) or HX 20 (elbow pipes) hydraulic connection pipe kits are delivered with the boiler in separate packages to be pre-installed and thus enable the installer to make all hydraulic connections, prime the installation with water and check for tightness in advance and only put the boiler in place at the last moment. HYDRAULIC CONNECTION ACCESSORIES: FOR REPLACING AN EXISTING BOILER concerns only MSL MI (FF) Package to order: Replacement kit comprising the water and gas connection hoses: Package HX 17 MS_Q0027 HX 51 MSL_Q0006 Hydraulic connection kit for a solar circuit with directional thermostatic valve (for MSL 2, 28, 1 MI (FF) only) - Package HX 51 This kit comprises the series of pipes needed to connect the boiler to a solar DHW calorifier and includes the directional thermostatic valve and the cold water isolating valve. It is used to combine a solar system with a boiler with instantaneous DHW production and, therefore, control of the solar DHW circuit according to the user s needs (see example p. 11). MS_Q000 Propane conversion kit - for MSL 2 - Package HX 5 - for MSL 28/1 - Package HX 5 BMR 80 SR 10 BMR 80 domestic hot water calorifier - Package EE 5 BMR 80/MSL connecting kit - Package HX SR 10 domestic hot water calorifier - Package EE 22 SR 10/MSL connecting kit - Package HX 2 MCR_Q0010 8666Q0A BMR 80 and SR 10 domestic hot water calorifiers are high performance calorifiers. They are protected inside by food quality standard high quartz content vitrified enamel and by a magnesium anode. The specifications of these calorifiers combined with MSL boilers are given on page. The boiler/water calorifier connection kit available include rigid and/or flexible connection pipes between the boiler and the calorifier. 7

INFORMATION REQUIRED FOR INSTALLATION FLUE SYSTEM ACCESSORIES SPECIFIC TO MSL FF DY 08 DY 76 DY 0 DY 10 8518F062 Aluminium horizontal flue gas terminal Ø 60/100 mm Package DY 08 Aluminium horizontal flue gas terminal Ø 80/125 mm Package CX 11 Aluminium vertical flue gas terminal Ø 80/125 mm Package DY 75 (black) or DY 76 (red) Aluminium adapter/condensates recuperator Ø 60/100 to Ø 80/125 mm Package DY 0 Aluminium condensates recuperator Ø 60/100 mm - Package DY 10 MS_Q0028 MS_F0015 MS_F0015 Bi-flow boiler connection kit - Package HX 0 Used to connect the chimney in configuration C 52. Kit for connection to CE pipe Ø 60/100 mm Package DY 11 If connecting to a CE pipe, use package DY 11 shown opposite. STATUTORY INSTRUCTIONS ON INSTALLATION AND MAINTENANCE Installation and maintenance of the appliance, whether in a residential building or in a building open to the public, must be carried out by a qualified professional in compliance with the statutory texts and codes of practice in force. IMPLANTATION Installation must be done in accordance with the prevailing codes of practice, orders and standards. MSL boilers can be installed at any point in a housing unit (even on a balcony) protected from frost, which can be ventilated. They must in no event be installed above a heat source or a cooking appliance. The IP X5D protection rating means that they can be installed in a kitchen or bathroom. The wall to which the boiler is secured must be capable of bearing the weight of the boiler when full of water. In order to ensure adequate accessibility around the boiler, we recommend that you respect the minimum dimensions given opposite. Minimum dimensions S1 25 min. 50 25 min. 780 min. 200 VENTILATION (MSL 2 MI ONLY) This must comply with prevailing regulations. S2 88 100 mini 5 min. 250 MSL_F0010 In order to avoid damage to boilers, it is necessary to prevent the contamination of combustion air by chloride and/or fluoride compounds, which are particularly corrosive. These compounds are present, for example, in aerosol spray cans, paints, solvents, cleaning products, washing powders/ liquids, detergents, glues, snow clearing salts, etc. It is therefore necessary: - To avoid taking in air discharged from premises using such products: hairdressers, dry cleaners, industrial premises (solvents), premises containing refrigeration systems (risk of leaking refrigeration fluid), etc. - To avoid the storage of such products close to the boiler. Please note that, if the boiler and/or its peripherals become corroded by chloride and/or fluoride compounds, our contractual warranty cannot be invoked. FLUE GAS DUCT (MSL 2 MI CHIMNEY VERSION ONLY) The cross-section of the chimney flue must be at least equal to that of the boiler s flue gas nozzle. The connection between the nozzle on the boiler and the chimney flue must be as short and as direct as possible. Its cross-section must not be smaller than that of the nozzle on the boiler. 8

INFORMATION REQUIRED FOR INSTALLATION AIR/FLUE GAS CONNECTION (MSL FF ONLY) For the installation of the air/flue gas pipes and the rules on installation, see the «Flue Systems» booklet. For details of the various configurations, see the «Flue Systems» booklet or the current Product Catalogue. Classification MSL FF wall-hung gas boilers are forced flue appliances to be connected according to one of the following suggested configurations: Configuration C 12x Configuration C 2x Configuration C 52 Configuration C 2x Lmax (m) Ø 60/ Ø 80/ 100 mm 125 mm Lmax (m) Ø 80/ Lmax (m) Ø 80 mm Lmax (m) Ø 60 /100 mm /125 Ø 80 mm 125 mm MSL 2 (MI) FF 5 MSL 2 FF 0 MSL 2 (MI) FF 5 MSL 2, 28, 1 FF 8 MSL 28 MI FF 8 MSL 28, 1 FF 25 MSL 28 MI FF 8 MSL 1 (MI) FF 7 MSL 1(MI) FF 7 C52 C12x Lmax LF Lmax Lmax LA MS_F001A Lmax = LA + LF LA max = 10 m GAS CONNECTION Compliance with prevailing instructions and regulations is mandatory. In all cases, a sectional valve is fitted as close as possible to the boiler. This sectional valve is fitted with the package HX 1 available in option. A gas filter must be fitted to the boiler inlet. Gas supply pressure: - 20 mbar on natural gas H, 25 mbar on natural gas L, - 7 mbar on propane. ELECTRICAL CONNECTION MSL boilers are delivered pre-fitted with a mains connection cable. The electrical connection must comply with the relevant standard. The boiler must be powered by an electrical circuit comprising an omnipolar switch with an opening gap > mm. Protect the connection to the mains with a 6A fuse. Note: - The sensor cables must be separated from the 20 V circuits by at least 10 cm; - In order to protect the pump antifreeze and cleaning functions, we recommend not switching off the boiler at the mains switch. HYDRAULIC CONNECTION MSL boilers must only be used in closed circuit heating installations. The central heating systems must be cleaned to eliminate the debris (copper, strands, brazing flux) linked to the installation of the system and deposits that can cause malfunctions (noise in the system, chemical reaction between metals). More particularly, if a boiler is added to an existing installation, it is necessary to rinse this installation thoroughly to prevent sludge being transferred into the new boiler. Furthermore, it is important to protect central heating systems against corrosion, scaling and microbiological growth by using a corrosion inhibitor suitable for all types of system (steel, cast iron radiators, underfloor heating, PER) The treatment products used in the heating water must be approved.

INFORMATION REQUIRED FOR INSTALLATION Manometric height of the heating circulator pump fitted to MSL 2 MI FF/MSL 2 FF/MSL 2 MI boilers Manometric height of the heating circulator pump fitted to MSL 28 MI FF/MSL 1 FF/MSL 1 MI FF boilers Manometric height (mbar) 600 550 500 50 00 50 00 250 200 150 100 50 0 II 0 200 00 600 800 1000 1200 100 Flow rate(l/h) III MSL_F0006 Manometric height (mbar) 600 550 500 50 00 50 00 250 200 150 100 50 0 I 0 200 00 600 800 1000 1200 100 Flow rate(l/h) II III INSTALLATION EXAMPLES The examples presented below cannot cover the full range of installation scenarios which may be encountered. Their purpose is to draw your attention to the basic rules to be followed. A certain number of control and safety devices (some of which are already integrated as standard in MSL boilers) are represented but it is ultimately up to the installers, experts, consultant engineers and design departments to take the final decision on the safety and control devices to be used in the boiler room according to its specificities. In all cases, it is necessary to abide by the codes of practice and prevailing regulations. Attention: For the connection of domestic hot water, a sleeve made of steel, cast iron or any other insulating material must be interposed between the hot water outlet and these pipes to prevent any corrosion to the connections, if the distribution pipes are made of copper. MSL 2 MI (FF) with 1 direct circuit, controlled by 1 room thermostat + outside sensor Hard-wired room temperature thermostat HX 1 21 51 AD 17 16 7 11/26 6 27 6 2 28 MS_F000 MSL_F0006 10

EXAMPLES OF INSTALLATIONS MSL 2 (FF) + BMR 80 with 1 direct circuit + 1 domestic hot water circuit, controlled by a hard-wired room temperature thermostat + outside sensor HX 1 Hard-wired room temperature thermostat 21 51 AD 17 16 7 6 27 11/26 2 27 20V 50Hz clock external 6 52 HX18+HX1 28 0 2 2 28 MSL_F0007 MSL 2 MI (FF) with 1 direct circuit, connected to a solar system, controlled by a hard-wired room temperature thermostat + outside sensor 112a 11 HX 1 21 Hard-wired room temperature thermostat AD 17 12 51 16 7 27 6 11/26 (summer) 6 20V ou 00V 50Hz HX 51 28 0 2 UNO BESL MSL_F0008 Legend -bar heating safety valve Pressure gauge 7 Automatic air vent 8 Manual air vent Isolation valve 10 -way mixing valve 11 Heating pump 16 Expansion vessel 17 Drain cock 21 Outside sensor 26 Domestic water load pump 27 Non-return valve 28 Domestic cold water inlet 2 Pressure reducer 0 Sealed safety device calibrated to 7 bar 2 (Optional) DHW looping pump DHW temperature sensor 6 2-position -way directional valve 50 Disconnector 51 Thermostatic valve 52 Differential safety valve 55 DHW safety valve calibrated and sealed to 7 bar 6 Radiator circuit (gentle heat radiators, for example) 8 Stop cock with unlockable non-return valve 85 Primary solar circuit pump 87 Safety valve calibrated to 6 bar 88 Expansion vessel solar circuit 8 Container for heat-carrying fluid 112a Solar collector sensor 12 Duo-tubes 10 Degasser with manual vent (Airstop) 11 Collector field 11

TECHNICAL DESCRIPTION ZENA MSL Brand: De Dietrich Range: ZENA PLUS Model: - MSL 2 MI for heating and instantaneous DHW and connecting to a chimney - MSL 2, 1 FF for heating only with integrated heating/dhw reversal valve and connecting to a forced flue - MSL 2, 28, 1 MI FF for heating and instantaneous DHW and connecting to a forced flue - MSL 2/1 FF + BMR 80/SR 10 for heating and DHW by 80-l juxtaposed calorifier/10-l calorifier placed under the boiler Nominal heating output at 80/60 C: 2 kw Min. heating output at 80/60 C:. kw (10. kw with MSL 28 MI and 1 MI) Gas used: natural gases - propane (with optional conversion kit) Gas pressure: mbar Gas flow rate: m /h Max. operating temperature: 85 C Max. operating pressure: bar Water content: 1. litres Safety thermostat: 105 C Dimensions (L x l x p): 50 x 780 x 5 mm Gas inlet: G / Ø Heating flow/return: G / Ø DHW flow/return: G 1/2 Ø chimney flue gas nozzle: Ø 120 mm Ø air/flue gas FF: Ø 60/100 mm Shipping weight: kg DESCRIPTION - Complies with the requirements of European Directives - Homologation: B 22 -C 12x -C 2x -C 2x -C 52 -C 82x (FF versions) - Type: B 11BS («chimney» version) - Chimney and forced flue model - Protection rating IP X5D - Efficiency level for versions FF and for chimney version (MSL 2 MI) in accordance with 2/2/CEE - Heating body in finned copper - Modulation from. (10.) to 2 (1) kw - 8-litre expansion vessel for MSL 2 and 10-litre for MSL 28/1 versions - Integrated flow/return by-pass - Ignition and flame monitoring by ionisation electrode - LCD control panel, troubleshooting system - Mechanical pressure gauge and low water pressure switch - Control according to outside conditions available as optional - Hydroblock in brass - Full equipment: safety valve, -speed circulating pump, disconnector, automatic vent - MSL MI (FF): Over-sized plate exchanger for the preparation of domestic hot water Specific flow rate at T 0 K: 1.7 l/min (MSL 1 MI FF) Hydraulic connection accessories and options To be chosen depending on whether it is a standard new installation, with mounting column, or replacement of an existing boiler: - Complete hydraulic connection plate - Complete hydraulic connection kit - Basic hydraulic kit - Replacement kit Boiler options - Propane conversion kit - Kit for hydraulic connection to a solar circuit with directional thermostatic valve (for MSL MI (FF)) Flue system options for MSL FF - Aluminium horizontal flue gas terminal Ø 60/100 mm - Aluminium horizontal flue gas terminal Ø 80/125 mm - Aluminium vertical flue gas terminal Ø 80/125 mm - Aluminium adapter/condensates recuperator Ø 60/100 mm to Ø 80/125 mm - Condensates recuperator Ø 60/100 mm - Bi-flow connection kit - Kit for connection to CE pipe Ø 60/100 mm Control system options - Non-programmable room temperature thermostat - Programmable hard-wired or radio-controlled room temperature thermostats - Outside sensor - DHW sensor - Relay card 07/201 000051 7.555.55 Strasbourg Companies Register Document not contractually binding - Printed in France - OTT Imprimeurs 6710 Wasselonne - 1157 DE DIETRICH THERMIQUE S.A.S. with corporate capital of 22 87 610 57, rue de la Gare - 67580 Mertzwiller Tél. + 88 80 27 00 - Fax + 88 80 27 www.dedietrich-heating.com