A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

Universal fuel unit for oil burners

568X, 587X, 588X Series

INSTALLATION & OPERATING INSTRUCTIONS

Light oil burners. One stage operation

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Light oil - kerosene burner

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

Installation Instructions

THE THOMPSON MODEL A STEAMER NEW UNIT ASSEMBLY INSTRUCTIONS

Parts Available from

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

SuperKlean Washdown Products

Installation & Maintenance Manual

569, 570, 571, 572 Series

MODEL CMA-180UC PARTS MANUAL Rev 1.18

Model 601CRD Oil Burner

TECHNICAL DATA. Wet 26a. February 22, 2009

Instructions for Installation, Operation, Care and Maintenance

Single stage operation oil burner

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

TK-1001, 1101, 1201, 1301, 1601

DRYAIRE DESICCANT SYSTEM MODEL 6760

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

INSTALLATION INSTRUCTIONS

Light oil / kerosene burner

Venco 75mm (3 ) Standard and De-airing Pugmill

RL 28/2-38/2-50/2 Low - High Operation

INSTALLATION INSTRUCTIONS

BERMAD Fire Protection

Series 1140 and 1141 Temperature Regulators

RL 70/2-100/2-130/2 Low - High Operation

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction MOL1650 T3N 323 2FH.

569, 570, 571, 572 Series

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

Climate Control System

V SERIES HDR GAS RANGES

INSTALLATION INSTRUCTIONS

Oil burners Brûleurs fioul Stookoliebranders

Forced draught gas burner

SECTION STEAM CONDENSATE PUMPS

ECLIPSE INFORMATION GUIDE

HEATING AND AIR CONDITIONING

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Raffaello From serial number Group

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

Power Washer Maintenance

15 20 kw kw kw

MODEL CMA-180UC PARTS MANUAL Rev 1.16

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Single stage operation oil burner

Outdoor Armor Water Heater Installation & Operation Manual Models:

FIREPLACE INSTALLATION

Grant Spira 6-26kW and 9-36kW Wood Pellet Boilers

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

PBG PACKAGED GAS BURNER

Teflon Rotary Drum Pump

The Safest Connections...

INSTALLATION INSTRUCTIONS WARRANTY

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F

SERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model

1998 Expedition/Navigator Workshop Manual

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)

INSTALLATION INSTRUCTIONS

Indirect gas-fired air heater

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER

ACORE Filtration Co.,Ltd provides engineering,

Service Step by Step Trouble-Shooting Check-List

347002K/177002K/34900

INSTRUCTION MANUAL DN0136 REVISION D

Single stage operation oil burners

Dosing system. Commissioning and maintenance manual eco-pen300

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

Chemical Motor Pump Unit BN

OPERATION & MAINTENANCE MANUAL TC670

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

CRN A-F-G-E-HQQE 3x400D 50 HZ

CYLINDER NOT INCLUDED

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

RETROFIT APPLICATIONS ONLY

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

LGB Gas fired boiler

Maintenance 5-1. Good maintenance is essential for cleaning results, and long economical life of the washer.

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

Transcription:

Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Italy - DE112/0404

Oil burners fuel unit with solenoid valve Type VM The DELTA fuel unit is an efficient modern oil burner pump with compact design and since its mounting flange, hub and shaft sizes are manufactured to international standards (EN 22), it can be fitted to every oil burner. 1- Features High suction capability. Suitable for one or two pipe systems. Self priming. Reliable pressure and positive cut-off. Solenoid valve incorporated. Special rotary shaft seal. Silent operation. Low power absorption. Easily installed and adjusted. 1 9 2 8 3 4 Pressure and vacuum gauge ports. 6 2- Applications The DELTA fuel unit type VM is designed for pumping oil in high pressure oil burners and transfer pump applications. WARNING It must not be used to pump water or acid. 3- Operation The VM fuel unit consists of a pump, solenoid valve, filter and pressure regulator valve housed within one casting. The pumping action is obtained from two spur gears (2), one of which is connected to the drive shaft (3). The pump casting provides the various oil ways, for the suction (6), return () and nozzle (9) ports. Pressure (8) and vacuum () gauge ports are also provided. The VM unit is available in two pipe and one pipe version. Both versions are self priming. From the suction side, the gears pass the oil to the pressure chamber, where it comes up against the head of the piston. Due to the build up of pressure, the piston is forced back against the pressure regulating spring. The flow of pressurized oil is interrupted by an incorporated solenoid valve (10), and can, therefore, be opened following the start of the motor (pre-purge), or interrupted before stopping the motor itself (instant shutoff of the flame preventing the nozzle dripping). The excessive oil discharges to the return side (or by-passes in the one pipe version). It will be realized of course that the spring tension, which is varied by the regulator screw (1), regulates the pressure of oil required. The pump can be converted from the single pipe version to the two pipe version, fitting the by-pass plug (4) in the return port. On start up, the rotating gears purge the air from the suction chamber, through a vent groove in the piston to the return line in two pipe version, and through the nozzle line (after the solenoid valve opening) in one pipe version. On initial commissioning, it is possible to bleed the air more quickly, through the pressure gauge. Because a vacuum now exists oil, due to atmospheric pressure, enters the suction chamber through the filter. 2 Printed in Italy - DE112/0404

4- Pump identification VM 1 R L 2 4 P F Pump type Nozzle capacity (see graphs) Rotation (seen from shaft end) R = clockwise L = counter clockwise Nozzle line (seen from cover) R = right L = left Pipes system 1 = one pipe 2 = two pipes Pressure ranges 3 = 2 10 bar 4 = 4 1 bar (Standard) = 8 20 bar 6 = 10 2 bar Factory setting 4 ±0,3 bar 10 ±0,3 bar 1 ±0,3 bar 20 ±0,3 bar Special versions U = cover type U with 6 cm² stainless steel filter, mesh 110µ (without pressure and vacuum gauge) P = auxiliary pressure port Coil type F = F84 coil with connector plug M = M8 coil with flexible metal conduit - Technical specifications Oil viscosity 1,2 0 cst Oil temperature.. 60 C max. Power consumption. See graphs Nozzle capacity.. See graphs Suction line vacuum. 0, bar max. Suction line pressure... 2 bar max. Return line pressure. 2 bar max. Rotation speed.. 300 rpm max. Standard strainer Nylon mesh 10µ, 20cm² (VM1 9cm²) Dimensions (EN 22)... Hub Ø32, shaft Ø8 (optionals : flanged hub Ø4, shaft /16 ) Connections (ISO 228/1)..... Inlet Return: G1/4 Nozzle port, Pressure / vacuum gauges: G1/8 Weight.. gr. 1100 6- Solenoid valve specifications Power absorbed.... 9 W Voltage tolerance.. -1% / +10% Environment temperature... 0 C / 60 C Working pressure..... 2 bar max. Flow factor (VDI/VDE 213).... 0,08 m 3 /h Cut-off pressure.... 4 bar Approval (EN 264)..... TÜV No. S102/04 Coil specifications F84 380V 0-60Hz 230V 0-60Hz M8 230V 0-60Hz L=00mm 110V 0-60Hz 24V 0-60Hz 230V 0-60Hz L=260mm 24V 9Hz 24V DC 110V 60Hz L=00mm 12V DC 24V 0Hz L=300mm L=300mm L=400mm 24V 0Hz L=00mm L=00mm L=00mm 24V 0Hz L=00mm L=1000mm L=1600mm 24V DC L=00mm 3 Printed in Italy - DE112/0404

P - Diagrams Nozzle capacity Power consumption L/h Visc. cst (1.4 E) 2800 RPM 12 100 Watts 200 Visc. cst (1.4 E) 2800 RPM VM4 VM3 10 VM4 VM3 0 100 VM2 VM2 VM1 2 VM1 0 10 1 20 2 Bar 10 1 20 2 Bar 8- Overall dimensions 84 94 10 20 102 1 9 Ø32 Ø8 28 40 63 V Made in Italy 8 23 19 42 4 (46xVM1) 96 (88xVM1) 2 6 10 Ø4 Ø8 20 102 1 Ø10. Made in Italy 9 2. 30. 34. 23 38 1 4 24 6 32 11 2 92 6 98 103 112 1 Pressure regulation Return 6 Suction Vacuum gauge 8 Pressure gauge 9 Nozzle port 10 Solenoid valve 11 Auxiliary pressure port 4 Printed in Italy - DE112/0404

P P 9- By-pass installation To convert the DELTA fuel unit from the single pipe version to the two pipe version, do the following: V a) Using a 19 mm wrench, remove the 1/4" plug from return port (Fig. 1). b) Located inside the return plug is the by-pass plug. Remove it with a 4 mm Allen wrench (Fig.2). c) Insert and screw the by-pass plug in the return port (Fig. 3). Fig. 1 19 To convert the DELTA fuel unit from the two pipe version to the single pipe version, do the following: Fig. 2 d) Using a 4 mm Allen wrench, unscrew the by-pass plug from the return port (Fig. 3). e) Insert and screw a 1/4" plug into the return port (Fig. 1). V WARNING - In the single pipe version, the air is bled through the nozzle line, after the solenoid valve opening. - In the two pipe version the air is bled through the return port. After conversion, the air must be bled manually, through the pressure gauge. - Make sure that the by-pass plug is not used in a single pipe installation, because the fuel unit will not function properly and damage to the pump and burner motor could result. Fig. 3 Printed in Italy - DE112/0404

Installation and Service Instructions 10- Installation and Maintenance 1. Make sure that the by-pass plug is not used in a single pipe installation, because the fuel unit will not function properly and damage to the pump and burner motor could result. 2. Do not use fuel with additives to avoid the possible formation over time of compounds which may deposit between the gear teeth, thus obstructing them. 3. After filling the tank, wait before starting the burner. This will give any suspended impurities time to deposit on the bottom of the tank, thus avoiding the possibility that they might be sucked into the pump. 4. On initial commissioning a dry operation is foreseen for a considerable length of time (for example, when there is a long suction line to bleed). To avoid damages inject some lubrication oil into the vacuum inlet.. Care must be token when installing the pump not to force the pump shaft along its axis or laterally to avoid excessive wear on the joint, noise and overloading the gears. 6. Do not force the valve stem and do not use it as lever.. Pipes should not contain air pockets. The number of junctions should be kept to a minimum as they are a possible source of leakage. 8. Rapid attachment joint should therefore be avoided. Always use O-Rings or mechanical seal (copper or aluminium gaskets) junctions if possible. 9. Avoid overtightening: G1/8" 1 Nm max. G1/4" 20 Nm max. 10. Do not use PTFE tape on the suction and return line pipes to avoid the possibility that particles enter circulation. These could deposit on the pump filter or the nozzle, reducing efficiency. 11. When junction threads, elbow joints and couplings are sealed with removable glue, avoid excessive quantities, which could enter in the oil ways and damage to the pump could result. 12.To clean the filter remove the cover. It must be thoroughly cleaned at least once in a season to ensure correct working of the fuel unit. The filter must be mounted with the supporting legs leaned against the pump body. If the joint plate between cover and pump housing should be damaged, it must be replaced. An external filter should always be installed in the suction line upstream of the fuel unit. 13. Make sure the combustion chamber is free of oil or oil vapor before operating the system. CAUTION: Turn off all power before servicing any part of the system. 11- Nozzle Pressure Test Most nozzles ratings are based upon 100 PSIG delivered oil pressure. The flow rate at the desired pressure must be estimated using the nozzle manufacturers data sheets. To insure that oil is delivered to the burner nozzle at the desired pressure, do the following: 1. Remove the 1/8" plug from the port marked "P" and connect a pressure gauge to this port (use a gauge of 0 to 300 PSIG or greater). The "P" port (Pressure Gauge Test Port) has been provided specifically for the connection of the pressure gauge for measuring the nozzle pressure; however, when available, it is also permissible to use the vent port for measuring nozzle pressure. 2. Start the burner motor, energize the solenoid valve and vent all air from the fuel unit and connected suction line system. 3. Check the adjustable nozzle pressure range of the fuel unit, using a 4 mm Allen wrench, turning the adjusting screw counter clockwise to lower the nozzle pressure and clockwise to increase the nozzle pressure. CAUTION: Adjust the nozzle pressure in accordance with the burner manufacturers specifications. 12- Nozzle Cut-Off Test Fuel oil is not compressible but air is. Air trapped in the nozzle line, anywhere between the fuel units nozzle port and the nozzle itself, will compress during burner operation. Following burner shutdown, any trapped compressed air will expand displacing the oil in the nozzle line, forcing continued oil flow through the nozzle that will, in effect, falsely appear to be poor fuel unit Cut-Off. This occurrence is particularly common with low flow rate nozzles used in conjunction with long air tubes. To verify positive nozzle Cut-Off after burner shutdown, do the following: 1. Remove the nozzle line and fitting from the nozzle port of the fuel unit and connect a 1/8" pressure gauge to the nozzle port (a gauge of 300 PSIG or greater be used). It may be more convenient to use a gauge fitted out with an extension nipple or with a line and flare nut to connect directly to the fitting installed into the nozzle port. If any type of extension is used between the nozzle port and the gauge, it should be kept as short as possible to minimize the amount of trapped air. 2. Start the burner motor, energize the solenoid valve and vent all air from the fuel unit and connected suction line system. 3. Shut off the burner motor. Initially the pressure will drop and then stabilize within a second or two. The pressure reading on the gauge should stabilize at 4 bar or greater and hold for at least two minutes. 13- Vacuum Test The vacuum test is necessary to verify the fuel unit's suction ability, to evaluate the leak tight integrity of the entire fuel unit and connected oil suction line piping system, to confirm that there are no abnormal restrictions in the oil suction line system, and, to confirm that the system vacuum is within the allowable specification limits of the unit. Please watch in any case the graphs for maximum suction line length depending on line diameter, viscosity, difference in height of suction line and pump or nozzle capacity. To perform the test, do the following: 1. Remove the 1/8" plug from the port marked "V" and connect a vacuum gauge to this port. 2. Start the burner motor, energize the solenoid valve and vent all air from the fuel unit and connected suction line system. 3. With the burner motor running, close the valve connected to the inlet port. You will note that the vacuum as measured by the vacuum gauge will increase. Allow the burner motor to continue to run until the highest vacuum reading is achieved. A fully primed fuel unit in good condition should be capable of pulling at least 20 lnhg. If not, before condemning the fuel unit, be sure that all connections and plugs are tight, the cover gasket is in good condition and the valve is in good working order. 4. De-energize the solenoid valve and shut off the burner motor. Initially, the vacuum reading will drop and then stabilize within a second or two. Once the vacuum reading stabilizes, record the reading. If the fuel unit is free of leaks, this reading should hold constant for at least 2 minutes. If the vacuum reading drops, there is a leak that must be located and corrected.. When each leakage is removed and the valve onto suction line is open, check to be sure that the actual operating vacuum does not exceed 1 InHg. Elettromeccanica Delta S.p.a. reserves the right to update or make technical changes without prior notice. 6 Printed in Italy - DE112/0404