Thermia Atec provides the greatest savings. Result from the test of air/water heat pumps, performed by the Swedish Energy Agency 2011.

Similar documents
SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

Do you want a versatile solution

Sweden s leading air source heat pump

Air to water Heat Pump System

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

Air to water Heat Pump System

Natural Heat VITOCAL 300-A VITOCAL 350-A. Air source heat pumps

w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q ***

EXHAUST AIR HEAT PUMPS EVALUATED FOR NORDIC CIRCUMSTANCES

VIESMANN. VITOCAL Air/water heat pumps. Technical guide. VITOCAL 300-A Type AWC-I and AW-O. VITOCAL 350-A Type AWH-I and AWH-O

ROTEX gas hybrid heat pump. A strong team.

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

Air / Water Heat Pump - Compact Design Modulating 8 18 kw

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

Remote control infrared ARC433B76 ARC433A8 ARC433B69

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

ROTEX HPDU monobloc Maximum efficiency in water heating

THE HEAT PUMP CHOICE OF PROFESSIONALS

Press. Heat pumps from Viessmann: efficient heat generation with renewable energy and electricity

Pure comfort & design

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G

Julie Klump, POAH Rick Fenuccio, Tom Hartman Marc Rosenbaum Melpet preliminary heat loss and energy model results and implications

Pure comfort & design

Air Conditioners Heating & Cooling

Pure comfort & design

Technical data LA 60TUR+

White paper: New Ecodesign rules and energy labelling for space and water heaters

Air Conditioners Heating & Cooling

Hybrid solutions. Heating systems Industrial systems Refrigeration systems

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Domestic Central Heating: Europe,

Technical Data Sheet. Brine/Water Heat Pumps 8 12kW - single phase 230V. Heliotherm Basic Comfort. Basic Comfort Advantages

Air Conditioners Heating & Cooling

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

Air Conditioners Heating & Cooling

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

Water and ground source heat pumps 61WG kw. Heating

Air Conditioners Heating & Cooling

Heat Pumps. ground-to-water models air-to-water models. Energy-saving solutions

for your home FLXS-B Flexi type unit air to air heat pumps

THE HEART OF YOUR COMFORT

User manual NIBE F2026

Sivu 2/8 Rate data Description Suomi Shut off times total 0.0 h/day Weekends with shut off times yes Daytime rate of heat pump Time for daytime rate 5

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

HT V2 HT Split

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

HEAT PUMPS LINE AS AIR TO WATER

Efficient heating that won t cost the earth

Inverter console UFV system. Compact design and personalised air flow selection

Chillers. Technical Data. EWYD-BZ 250~580 kw

High temperature heating system AIR TO WATER HEAT PUMPS. Renovation - Heating - Domestic hot water

NIBE Air/water heat pumps CAPTURE FREE ENERGY FROM THE OUTSIDE AIR

Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5)

A strong team A ++ A +++ ROTEX gas hybrid heat pump

AQUAHEAT ADVANCE SPLIT

VRV The total solution. Integrated Climate Control

Call or visit solarshop.com.au

Central Home Heating and Hot Water Supply

Solar heating. Free heat from the sun!

NEW GENERATION. Efficient use of valuable space INCUBATORS

SDU A. SDU A Loops. (available in 3, 4, 5 loops) Water Based Systems. Standard Distribution Unit assembled with: A Blank Port (capped)

Tel: Heronhill - For all your Toshiba heating and cooling requirements Air to water Heat Pump System

Technical description. Atec.

INVERTER DUCTED SYSTEMS

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Public. Altherma by Daikin. Altherma Commissioning Service Field Settings

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

CONVENIENT FEATURES ...MORE PERFORMANCE LESS... SPACE ENERGY NOISE G-TEC BELT-DRIVEN ROTARY SCREW AIR STATION. 7.5 to 22 kw 8 to 13 bar

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

TRANQUILITY WATER-TO-WATER SERIES

Technology that works fast. Inverter Ducted Systems

According to the following European Regulations which come into force:

Daikin 15 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS 15 SERIES WALL MOUNTED UNITS Up to 15 SEER / Up to 8.2 HSPF / Up to 12.

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems

Time to rethink heating

AIR CONDITIONERS, HEATING & COOLING for your home

TECHNICAL SPECIFICATIONS BUTTONS

Technical data LA 60TU

PRODUCT GUIDE EARTHLINKED TECHNOLOGIES GEOTHERMAL RENEWABLE ENERGY SYSTEMS SIMPLE. EFFICIENT. EFFECTIVE.

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

Air Conditioners Heating & Cooling

Technical data LA 28TBS

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps. FTXS-G

SERIES. Ductless Split Comfort Systems. Mark of Superior Quality ADVANCED TECHNOLOGY ENERGY SAVINGS ECO-FRIENDLY NEW RESIDENTIAL LINE

Pure comfort & design

KELVIN BELT-DRIVEN ROTARY SCREW AIR STATION, FIXED OR VARIABLE SPEED. from 7.5 to 22 kw from 8 to 13 bar

About Daikin: WARNINGS:

Comfort. Health Clean. Saving. The new era in air conditioning. Multi-Split Systems

MRVIII-S. 007 Features & Benefits 017 MRVIII-S Outdoor

Heating with natural heat

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

User manual JÄSPI Inverter Nordic 8, 12, 16, 20

Planning guide. (2010/09) en

User manual. JASPI COMFORT MONO 8 & 12Kw UK 1x230V. Air/water heat pump LEK

Transcription:

Atec provides the greatest savings Result from the test of air/water heat pumps, performed by the Swedish Energy Agency 2011.

Summary Result from the test of air/water heat pumps performed by the Swedish Energy Agency September 2011. Atec test winner in efficiency Atec is the test winner in terms of efficiency. Out of 12 tested air/water heat pumps, Atec is the product that provides the greatest overall cost savings. This is made possible by having the highest Seasonal Performance Factor. Low sound level The test shows that Atec is very quiet, the sound power level is only 61 db (A). Hot water comfort Atec has top of class results regarding hot water comfort. High temperature in the hot water tank Large quantities of 40 C hot water Low energy losses Built-in cooling function Atec is one of two heat pumps in the test with built-in cooling. The test result shows that Atec delivers top performance also for cooling. 2013-07-29 Information about the Swedish Energy Agency Information about the test 2

Atec provides the greatest savings Atec has the highest Seasonal Performance Factor (SPF*) in the test. This gives Atec the lowest energy cost of all tested models. Highest SPF in all measured cases Annual efficiency has been tested for three different house sizes; with an annual consumption of 15 000 kwh/year, 25 000 kwh/year and 35 000 kwh/year. Atec is the winner in all three cases. Appendix SPF Diagram SPF Atec have the biggest energy savings in the test For small houses (~15 000 kwh/year) the annual savings are 300-1400 kwh bigger than with the other models For medium houses (~25 000 kwh/year) the annual savings are 700-3000 kwh bigger than with the other models For big houses (~35 000 kwh/year) the annual savings are 800-5100 kwh bigger than with the other models Appendix Savings Diagram Savings Atec has the highest COP at all measurement points A single high COP value* is no guarantee for big savings in real operation. The key is to be efficient throughout the whole operating range, i.e. at all possible temperatures. Therefore, a series of COP values, spread out over the whole operating range, can give an indication of the real efficiency of the heat pump. Appendix COP Diagram COP 2013-07-29 3

Very low sound level The sound level of Atec is extremely low. Atec has a very low sound level, the second lowest in the test. Sound power level = 61 db. Appendix Sound level It is also possible to run Atec in "Silent Mode", which lowers the sound level further. 2013-07-29 4

Top of class hot water comfort Atec shows excellent test results regarding hot water comfort. Low energy losses Thanks to very low energy losses from the hot water tank (efficient isolation), the cost for water heating is minimized. High temperature in the hot water tank Atec has the second highest hot water temperature in the test. The advantage with this is a larger amount of 40 C hot water out from the tank. The drawback is a slightly lower COP for the water production. Large quantities of 40 C hot water Of all tested models, Atec has the largest amount of 40 C hot water in relation to volume of the hot water tank. This ensures an excellent hot water comfort without requiring a large space for the water heater. A 300 litre hot water tank can provide up to 500 liters of 40 C hot water when needed. Appendix Hot water comfort 2013-07-29 5

Additional results Atec has many other important benefits that appear in the test. Works efficiently down to -20 C Several of the manufacturers brag about how low outdoor temperatures they can handle, even as low as -20 C. The test however reveals that, in most cases, this is not true they can t. When it comes to Atec, the test result shows great savings down to -20 C. Built-in cooling function Atec is one of only two heat pums in the test with built-in cooling. The test result shows that Atec delivers top performance also for cooling. Appendix cooling Easy-to-understand User manual Only five of the User manuals in the test were approved. Atec was one of the five which recieved the rating "good". 2013-07-29 6

Other observations A few other things in the test that are worth noting. CTC provides only 81 liters of hot water, Daikin only 113 liters The way that CTC has chosen to produce hot water, means that you only get 81 liters of 40 C hot water out of a 223 liter hot water tank. To get more hot water, the electrical heater cartridge must be turned on. Also Daikin shows a remarkable low value on this measure; only 113 liters out of a 200 liter hot water tank. CTC, Nibe, Toshiba and Daikin never reached 55 C out to the radiators CTC, Nibe, Toshiba and Daikin could not reach 55 C outgoing temperature to the radiators a temperature that was required for the test. CTC were unable to run at the low level temperature, stated by them selves CTC state that their heat pump can run down to -15 C. However, the heat pump sent to the test was factory set for -10 C. 2013-07-29 7

Information about the Swedish Energy Agency The Swedish Energy Agency is a government agency for national energy policy issues. The Agency s headquarters are in Eskilstuna and it has around 300 employees. Their mission is to promote the development of Sweden s energy system so that it will become ecologically and economically sustainable. Strategic objectives: - The Agency works to ensure that energy matters are automatically taken into account in relevant social sectors. - The Agency supports the achievement of the national climate targets. - The Agency promotes an energy system that is economical on resources and energy efficient, and that uses an increasing proportion of renewable energy sources. - The Agency works to ensure that there is a safe and reliable energy supply. - The Agency works for efficient energy markets in which customers have a strong position. - The Agency is a modern and efficient public authority in all respects. - The Agency is an attractive employer whose employees are given good development opportunities in a sound working environment. For more information: www.energimyndigheten.se 2013-07-29 8

Information about the test The test includes 12 different air/water heat pumps. Nine of the heat pumps are tested in 2011 and three are tested during 2006-2009. The test has been conducted by SP (Technical Research Institute of Sweden) on the initiative of the Swedish Energy Agency. The test is objective and done according to standard methods. Following methods are included in the test: Space heating performance, according to EN 14511 Sanitary hot water heating, according to EN 255-3 Sound power level, according to EN ISO 3747, EN 12102 Calculation of annual energy savings, according to SP-method 0033 Review of heat pump and documentation Read more about the test (Swedish language): www.energimyndigheten.se/sv/hushall/testresultat/testresultat/luftvattenvärmepumpar1 2013-07-29 9

Appendix SPF (Seasonal Performance Factor) Bosch EHP 8 AW CTC Eco Air 107 Euronom Exo Air Nibe F-2025 Carrier Toshiba Aqua Snap Plus Estia HWS-802H-E IVT Prem.Line A Plus Atec Daikin ERLQ011CAW1 Viessmann Vitocal-300 AW-O Sirius S2-7 Luft Atria Optimum House: 15 000 kwh/year SPF 2,5 2,7 2,8 2,6 2,8 2,9 2,7 3,0 2,7 2,7 2,4 2,6 House: 25 000 kwh/year SPF 2,4 2,4 2,6 2,5 2,3 2,6 2,7 2,9 2,7 2,8 2,2 2,4 House: 35 000 kwh/year SPF 2,1 2,1 2,3 2,3 2,0 2,3 2,6 2,7 2,6 2,6 1,9 2,4 2013-07-29 11

SPF (Seasonal Performance Factor) 3,0 2,8 2,6 2,4 2,2 2,0 1,8 Atec 15 000 25 000 35 000 House size (kwh/year) Bosch CTC Euronom Nibe Carrier Toshiba IVT Atec Daikin Viessman Sirius Atria 2013-07-29 12

Appendix Energy savings Bosch EHP 8 AW CTC Eco Air 107 Euronom Exo Air Nibe F-2025 Carrier Toshiba Aqua Snap Plus Estia HWS-802H-E IVT Prem.Line A Plus Atec Daikin ERLQ011CAW1 Viessmann Vitocal-300 AW-O Sirius S2-7 Luft Atria Optimum House: 15 000 kwh/year Energy savings 9 000 9 400 9 600 9 300 9 600 9 700 9 500 10 000 9 500 9 500 8 600 9 200 (kwh/year) House: 25 000 kwh/yesr Energy savings 14 600 14 800 15 400 15 100 14 300 15 300 15 800 16 500 15 700 16 000 13 500 14 800 (kwh/year) House: 35 000 kwh/year Energy savings 18 600 18 500 19 600 19 700 17 600 19 500 21 300 22 200 21 400 21 400 17 100 19 100 (kwh/year) 2013-07-29 13

Energy savings (kwh/year) 22 500 20 500 18 500 16 500 14 500 12 500 10 500 8 500 Atec 15000 25000 35000 House size (kwh/year) Bosch CTC Euronom Nibe Carrier Toshiba IVT Atec Daikin Viessman Sirius Atria 2013-07-29 14

Appendix COP (Coefficient Of Performance) Bosch EHP 8 AW CTC Eco Air 107 Euronom Exo Air Nibe F-2025 Carrier Toshiba Aqua Snap Plus Estia HWS-802H-E IVT Prem.Line A Plus Atec Daikin ERLQ011CAW1 Viessmann Vitocal-300 AW-O Sirius S2-7 Luft Atria Optimum 35 C to radiators Out door temp: +7 3,5 3,8 4,2 3,5 3,6 4,1 3,9 4,7 4,6 4,2 3,5 3,5 Out door temp: +2 2,9 3,2 3,6 3,2 2,9 3,3 3,5 3,9 3,5 3,6 3,1 3,1 Out door temp: -20 2,3 45 C to radiators Out door temp: +7 2,9 3,2 3,3 3,0 2,9 3,3 3,2 3,8 3,5 3,3 2,9 3,0 Out door temp: +2 2,4 2,7 3,0 2,8 2,4 2,7 2,9 3,1 2,7 3,1 2,6 2,6 Out door temp: -7 2,2 2,3 2,4 2,3 2,2 2,3 2,5 2,7 2,3 2,4 2,1 2,3 Out door temp: -15 1,8 1,9 2,0 1,9 1,5-2,1 2,2 1,9 2,0 1,7 1,9 55 C to radiators Out door temp: +7 2,5 did not 2,8 did not 2,7 did not 2,8 3,1 did not 2,9 2,4 2,5 Out door temp: -7 1,8 reach 55 C 2,0 reach 55 C 1,9 reach 55 C 2,0 2,2 reach 55 C 2,0 1,7 1,9 2013-07-29 15

COP (Coefficient Of Performance) 4,6 4,2 3,8 3,4 3,0 2,6 2,2 1,8 1,4 Atec +7/35 +2/35 +7/45 +2/45-7/45-15/45 +7/55-7/55 Measuring point Bosch CTC Euronom Nibe Carrier Toshiba IVT Atec Daikin Viessman Sirius Atria 2013-07-29 16

Appendix Sound level Bosch EHP 8 AW CTC Eco Air 107 Euronom Exo Air Nibe F-2025 Carrier Toshiba Aqua Snap Plus Estia HWS-802H-E IVT Prem.Line A Plus Atec Daikin ERLQ011CAW1 Viessmann Vitocal-300 AW-O Sirius S2-7 Luft Atria Optimum Sound power level 64 69 69 65 67 65 56 61 63 61 71 67 db(a) 2013-07-29 17

Appendix Hot water comfort Bosch EHP 8 AW CTC Eco Air 107 Euronom Exo Air Nibe F-2025 Carrier Toshiba Aqua Snap Plus Estia HWS-802H-E IVT Prem.Line A Plus Atec Daikin ERLQ011CAW1 Viessmann Vitocal-300 AW-O Sirius S2-7 Luft Atria Optimum Volume hot water tank 145 223 278 155 200 210 280 180 200 390-480 (litre) Amount hot water 40 C 210 81 316 196 255 250 337 300 113 590 495 740 (litre) Volume ratio 1,4 0,4 1,1 1,3 1,3 1,2 1,2 1,7 0,6 1,5-1,5 (=amount 40 C/tank volume) Energy losses 1900 1300 1200 1000 1400 760 900 600 650 500 1000 1000 (kwh/year) Temperature in tank 53 C 49 C 53 C 47 C 56 C 46 C 50 C 61 C 47 C 56 C 67 C 58 C COP 2,3 3,0 3,3 3,3 2,8 3,3 3,3 2,6 2,4 2,7 2,6 2,6 (hot water production) 2013-07-29 18

Appendix EER (Cooling factor) Bosch EHP 8 AW CTC Eco Air 107 Euronom Exo Air Nibe F-2025 Carrier Toshiba Aqua Snap Plus Estia HWS-802H-E IVT Prem.Line A Plus Atec Daikin ERLQ011CAW1 Viessmann Vitocal-300 AW-O Sirius S2-7 Luft Atria Optimum 7 C to radiators Out door temp: +35 C - - - - - - - 2,3 - - - - 18 C to radiators Out door temp: +35 C - - - - - - - 2,5 - - - - 2013-07-29 19

Glossary SPF (Seasonal Performance Factor) A value describing how efficient a heat pump is over a full year, where both warm and cold periods are counted, and the hot water production is included. The most accurate value to see how efficient a heat pump is in real operation. COP (Coefficient of Performance) A value describing the heat pump's efficiency in one unique operating condition. The relation ratio between consumed and supplied energy. 2013-07-29 20