PVC Ductwork Model. Installation and Maintenance for

Similar documents
Installation and Maintenance for FlexValue Cleanroom Ceiling Model

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

568X, 587X, 588X Series

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

TECHNICAL DATA. Wet 26a. February 22, 2009

INSTALLATION INSTRUCTIONS

569, 570, 571, 572 Series

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

IB 835. Installation Manual. Integrated Bidet Toilet TABLE OF CONTENTS

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

Silverware Pre-washing System INSTALLATION

569, 570, 571, 572 Series

Models , Equinox, and Sirens Clutch Replacement Service Manual

Heater Core Replacement

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

Heat Exchanger Block Replacement Instructions

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

WARNING. Flexible Hose AH2 With AB6 With AB6. AH2-CC With AB6 With AB6

#PSBTWE1000 INSTALLATION GUIDE

Installation Instructions

STONE TROUGH CONSOLE SINK

Clean Water Made Easy

INSTALLATION INSTRUCTIONS

SWIVEL HEAD WASTE AND OVERFLOW INSTALL

Service Bulletin No.: DAC Rev 0 Date Issued: November 9, 1999 Title: Powerplant Cooling Page: 1 of 10

Air Conditioner. user installation & manual manual. imagine the possibilities

NSSI Packaging Instructions

Installation Manual PS-225 & PS-275

Installation Instructions

SEALED ENCLOSURE COOLING

REACH ORDERING INFORMATION NOTES T01-B

Things you might need for the installation: vessel sink, plumber's putty(home depot), liquid nails(home depot), Bucket silicone caulk(home depot),

ARCHERTM ORDERING INFORMATION NOTES T01-C INSTALLATION INSTRUCTIONS VITREOUS CHINA ONE-PIECE TOILET K-3639T/K-3639T-C

Norminal Sprinkler Temperature Rating

BlueHeat AirTop 2000 Heater

Instructions for Installing the MMD Rear Window Louvers

Detailed Cleaning Instructions

Fleck 2510 SXT Catalox Installation & Start Up Guide

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

Acrylic Claw Foot Tub

Things you might need for the installation: vessel sink, plumber's putty(home depot), liquid nails(home depot), Bucket silicone caulk(home depot),

Parts & Material Included

Installation Instructions for SHD Series Drawers

Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330*

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

INVERTER SPLIT - TYPE

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

STAINLESS STEEL UNITS

INSTALLATION INSTRUCTIONS

SPRINKLER HEAD. Vertical Sidewall Sprinkler MODEL: SD2133, SD2121 DESCRIPTION MAXIMUM COVERAGE TECHNICAL SPECIFICATION SPRINKLER OPERATION RATINGS

ADAIR ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS 4.0L EXPOSED CLASS FIVE ONE-PIECE TOILET 4.0 K-5306T/K-5306T-S

MEMOIRS VITREOUS CHINA TOILETS

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate

ESS. Environmental. Shield System. Instruction Manual. Environmental Shield System - ESS

DESCRIPTION MAINTENANCE INSTALLATION OF NEW SEAL REMOVAL OF OLD SHAFT SEAL

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

GRANITE COMPOSITE SINK

SAN RAPHAEL GRANDE ORDERING INFORMATION NOTES T01-B INSTALLATION INSTRUCTIOINS 4.8L SKIRTED CLASS FIVE ONE-PIECE TOILET 4.

REVE ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS 现代型分体座便器 CONTEMPORARY TWO-PIECE TOILET K-17178T-S/K-17178T-SP

Cased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Installation Manual. Breeder Control Installation Manual Patented U.S. Patent No. 7,980,129 and Patents Pending

TECHNICAL INSTRUCTIONS

REVIVAL LITE VITREOUS CHINA REVERSE TRAP TOILET

OPERATOR S MANUAL STANDARD BALL BEARING CHESTS & ROLLER CABINETS

Qualification Procedures for making PE 3408 Extra High Molecular Weight Polyethylene Heat Fusion Joints

LUDGATE SINGLE HOLE FAUCET INSTALLATION

Socket Heat Fusion Techniques. A Guide for Instruction and Training in Vanguard Socket Heat Fusion

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

0RGHOV,QGRRU 8QLW MWM36Y3J 2XWGRRU 8QLW MRM36Y3J 11

FPU SYSTEMS OPERATION MANUAL (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH CONTAINERIZED LATRINES BOH FPU Field Pack-up Units

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS

Installation Instructions

Clean Water Made Easy

Installation Instruction

Karess ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS

PROFESSIONAL S2 SAFE USER GUIDE ELECTRONIC LOCK USER GUIDE.

Acrylic Claw Foot Tub

PORTRAIT LITE VITREOUS CHINA REVERSE TRAP TOILET

OWNER S MANUAL WISTERIA

REVE ORDERING INFORMATION NOTES T01-E INSTALLATION INSTRUCTIONS ELONGATED TWO-PIECE TOILET K-17178T-S2/K-17178T-SBG2/K-17178T-SP2

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

IRON/TONES TM REQUIRED 2T1A TOOLS AND 1 MATERIALS T01-A INSTALLATION INSTRUCTIONS / SELF-RIMMING OR UNDERCOUNTER KITCHEN SINK K-6625

VSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold

W / E / W / E / $10.00

3/4.8 AERODYNE 3/4.8L CLASS FIVE+

NELSON HEAT TRACING SYSTEMS

ACRYLIC PEDESTAL TUB

Installation Manual PS-200 & PS-201

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS

Teflon Rotary Drum Pump

CUSTOMER SERVICE. Toll-free:

Transcription:

Installation and Maintenance for PVC Ductwork Model WARNING! These installation instructions are for qualified and experienced technicians in the H.V.A.C. and Fire Protection field only. Failure to follow these specific instructions may cause personal injury. Installation or maintenance technicians must read the entire manual prior to attempting installation or maintenance of product. Installation should take approximately 10-20 minutes per head. (Not Including cure time.) Retain these instructions for future use. Tools Required Right Angle Drill 2 Metal Holesaw 3/8 Drill 3/16 Metal Drill Bit Torque Wrench (1-50 inch-lb.) Safety Glasses Particle Mask Vinyl Gloves Duct Tape Clean Rags Safety Face Shield Materials Required PVC Primer PVC Cement PVC Ductwork Model Installation and Maintenance Manual 41

Safety glasses, vinyl gloves and particle mask must be worn by installing technician during FLEXHEAD PVC Ductwork Model installation. PART I INSTALLATION OF BOTTOM MOUNTING BLOCK 1FlexHead Location Determine desirable location for FLEXHEAD unit in ductwork. FLEXHEAD unit must be accessible for periodic inspection. For recommended guidelines and standards for protection systems in industrial exhaust systems see Factory Mutual loss prevention data sheets 7-78, article 2-4. Once desired location is determined drill a two-(2) inch hole in duct with holesaw. 2Mounting Bottom Block Method #1 A. Remove any ragged edges or burrs from 2 hole in duct. Clean 6 by 6 square area around hole in duct of dirt, grease, and moisture. B. Apply PVC primer evenly and freely to 6 by 6 area around 2 hole in duct, using supplied dauber applicator. C. Apply PVC primer to bottom of FlexHead PVC mounting block evenly and freely using supplied dauber applicator. D. Apply a full even layer of cement on the 6 x 6 prepared area on duct with supplied dauber applicator. Apply a full even layer of cement on bottom curvature of FlexHead mounting block. Cement layers must be without voids and sufficient to fill any gap between duct and mounting block. Place PVC mounting block on prepared area on ductwork, immediately, making sure 2 hole in duct and 2 hole in mounting block are aligned. Assemble without delay while cement is still wet. Hold mounting block on duct firmly for about 30 seconds or until cement has begun to cure. With a rag, wipe away any excess cement from four sides of mounting block. Avoid disturbing the joint. E. Allow 15 minutes for good handling strength. Cure times will vary depending on size, temperature, etc. Consult PVC cement manufacturers directions for additional details. If any problems exists with industrial strength PVC cement during the installation, use air weld method of installation method #2 on following page. PVC Ductwork Model Installation and Maintenance Manual 42

2Mounting Bottom Block Method #2 Place FlexHead bottom mounting block on duct. Align 2 hole in ductwork with 2 hole on FLEXHEAD bottom block. With plastic welding torch tack FlexHead bottom mounting block on to ductwork on all four sides of block. Air weld FlexHead bottom mounting block on to ductwork on all four sides following welding manufacturer s guidelines and recommendations. (A minimum of three welds on each side of FLEXHEAD block is required.) For additional information call (800) 829-6975 or (978) 264-0822. 43

During installation of FLEXHEAD product fire protection system must be fully drained and the exhaust system shut down. Do not attempt FLEXHEAD installation when either system is operational. Consult NFPA Guidelines for details. PART II INSTALLATION OF TOP MOUNTING BLOCK 1Connect FlexHead to Sprinkler System Connect one-(1) inch stainless steel flexible hose of FLEXHEAD to one-(1) inch black iron pipe union of fire protection system in accordance to NFPA standards, state and local codes. 2Connect Top Mounting Block Place top FLEXHEAD mounting block onto previously installed bottom mounting block with gasket. Make sure that sprinkler head section of the FLEXHEAD unit is inserted into two-(2) inch hole in duct, and that the four-(4) stainless steel bolts of bottom mounting block align with corresponding bolt holes in top mounting block. Angle of flexible hose should not exceed 90. Place one-(1) stainless steel washer and one-(1) stainless steel nut onto each of the four-(4) stainless steel bolts. Tighten each of the nuts hand tight onto the block. Tightening process of nuts onto the mounting block should be done in a diagonal process to ensure equal distribution of pressure throughout the mounting block. Nuts should be tightened to 15 in.-lb. using a torque wrench. DO NOT OVER TIGHTEN NUTS ONTO BLOCK. Installation of FLEXHEAD is complete. PVC Ductwork Model Installation and Maintenance Manual 44

Safety face shield, vinyl gloves and particle mask must be worn by maintenance technicians during FLEXHEAD maintenance. WARNING! During installation of FLEXHEAD product fire protection system must be fully drained and the exhaust system shut down. Do not attempt FLEXHEAD installation when either system is operational. Consult NFPA Guidelines for details. INSPECTION OF PVC DUCTWORK MODEL SPRINKLER HEAD 1Once fire protection and exhaust system are inactive, proceed with inspection of FLEXHEAD unit. 2Remove the four-(4) stainless steel nuts and washers from top mounting block. 3Now lift top mounting block from bottom mounting block and bolts, by holding onto base of stainless steel hose. 4Inspect sprinkler head and polybag section of FLEXHEAD. IF DAMAGE EXISTS IN OUTER POLYBAG ONLY, REPLACE BOTH BAGS AT THIS TIME. If damage exists through both polybags remove remainders of polybags and inspect wax coated sprinkler head. IF ANY DAMAGE EXISTS IN SPRINKLER HEAD REPLACE HEAD AND BOTH POLYBAGS AT THIS TIME in accordance to NFPA regulations and guidelines. To order additional gasket/dual polybag assemblies call (800) 829-6975 or (978) 264-0822. 5Once inspection and maintenance of FLEXHEAD has been completed, reinsert top mounting block onto bottom block aligning corresponding sprinkler head and bolt holes. 6Replace the four-(4) stainless steel washers and nuts onto the four-(4) stainless steel bolts accordingly. Hand tighten each of the four-(4) nuts onto the block. The tightening sequence of nuts onto the mounting block should be done in a diagonal manner to ensure equal distribution of pressure throughout the mounting block. Nuts should be tightened to 15 in.-lb. using a torque wrench. DO NOT OVER TIGHTEN NUTS ONTO BLOCK. MAINTENANCE OF FLEXHEAD IS COMPLETE. PVC Ductwork Model Installation and Maintenance Manual 45