INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Certificate No.: lecex BVS X issue No.:1 Certificate history: Issue No. 1 ( ) Status:

IECEx Certificate of Conformity

IECEx Certificate of Conformity


IECEx Certificate of Conformity

Ex-d luminaire type dklk 23 (V-CG-S) GHG W. Flameproof enclosure 'd', Equipment dust ignition protection by enclosure 't' Dr. F.

IECEx Certificate of Conformity

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

INTERNATIONAL ELECTROTECHNICAL COMMISSlON IEC Certification Scheme for Explosive Atmospheres

slra IEC of Gonformity IECEx Cert f cate ü* t4

srra, of Conformity IECEx Gert f cate ?-ot,b

FLASHLIGHT ANSI STANDARDS

Explosion-protected actuator Page 259 of 292

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

VERSAFLOW VORTEX Supplementary instructions


FLASHLIGHT ANSI STANDARDS

Certificate of Conformity

INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME)

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

Technical Data. Dimensions

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

INSTRUCTION MANUAL (ATEX / IECEx)

Inductive slot sensor

User s Manual YTA610 and YTA710 NEPSI Certification

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

INTERNATIONAL STANDARD

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 1: General requirements. Australian/New Zealand Standard

Technical Data. Dimensions

Drive systems for the chemical, oil and gas industry. Electric drives and systems

Certification Supplement Manual

Survey of electrical equipment installed in hazardous areas on tankers

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Technical Data. Dimensions

TYPE APPROVAL CERTIFICATE

PEPPERL+FUCHS GmbH

OPTIBAR DP 7060 Supplementary Instructions

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

End of Life -Discussion on Ex Luminaires for Fluorescent Lamps in Zone 1? Not a Problem for Us! EVG 05

Exp, pressurized systems

Technical Data. Dimensions

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION & SERVICE MANUAL

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

INSTRUCTION MANUAL (ATEX / IECEx)

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

INSTRUCTION MANUAL (ATEX / IECEx)

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

Certificate of Compliance

An Introduction to the IECEx System and IECEx Scheme Certification Processes IECEx Secretariat January 2018

National Standard of the People's Republic of China

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

This document is a preview generated by EVS

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Certificate of Compliance

Certificate of Compliance

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Electrical Installations Design, Selection, Erection and Inspection

Australian/New Zealand EXPLOSION-PROTECTED ELECTRICAL EQUIPMENT ANZ. Cerc1ficace ofconfor1221t:y. Issue No.: 6 Date oflssue:

Physikalisch-Technische Bundesanstalt

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

Explosion-proof Immersion Heater Type D-8660

Hazardous Location Heaters. Thermostat INSTRUCTION MANUAL

INTERNATIONAL STANDARD

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

INSTRUCTION MANUAL (ATEX / IECEx)

Certificate of Compliance

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Explosive atmospheres. IECEx. International Electrotechnical Commission

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Dust Explosion Protection Consistent with North American Practice

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Immersion heating type FL65.. PTB 97 ATEX 1027 X. March thuba Ltd. CH-4015 Basle Telefon Telefax

Easy installation Certified for zones 1 and 21 High IP degree of protection

Transcription:

Page 1 of 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:1 Status: Current Certificate history: Issue No. 1 (2008-5-21) Issue No. 0 (2004-11- 17) Date of Issue: 2008-05-21 Page 1 of 5 Applicant: UNI-Geraete E. Mangelmann Elektrotechnische Fabrik GmbH Holtumsweg 13 47652 Weeze Electrical Apparatus: Solenoid actuator type MG 0..-.. Optional accessory: Type of Protection: Flameproof Enclosure "d", Protection by Enclosures "td" Marking: Ex de IIC T5 Ex td A21 IP65 T 95 C Tamb - 20 C to + 60 C Approved for issue on behalf of the IECEx Certification Body: Position: Dr.-Ing Uwe Klausmeyer Head of Section "Flameproof Enclosure" Signature: (for printed version) Date: 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website. Certificate issued by: Physikalisch-Technische Bundesanstalt (PTB) Bundesallee 100 38116 Braunschweig Page 2 of 5 Manufacturer: UNI-Geraete E. Mangelmann Elektrotechnische Fabrik GmbH Holtumsweg 13 47652 Weeze Manufacturing location(s): This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0 : 2004 Edition: 4.0 IEC 60079-1 : 2003 Edition: 5 IEC 60079-7 : 2006-07 Edition: 4 IEC 61241-0 : 2004 Edition: 1 IEC 61241-1 : 2004 Edition: 1 Electrical apparatus for explosive gas atmospheres - Part 0: General requirements Electrical apparatus for explosive gas atmospheres - Part 1: Flameproof enclosure 'd' Explosive atmospheres - Part 7: Equipment protection by increased safety "e" Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "td" This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. TEST & ASSESSMENT REPORTS: A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in IECEx ATR: DE/PTB/ExTR08.0021/00 File Reference:

Page 2 of 5 'QAR: DE/PTB/QAR07.0006/01

Page 3 of 5 Page 3 of 5 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: Description of equipment Solenoid actuator type MG 0..-.. of different rating classes for the control of valves, alternatively with pickupand holding winding. Technical data Rated voltage max. 420 V Ambient temperature -20 C up to +60 C Protection against contact, foreign bodies and water IP65 according to EN 60529 CONDITIONS OF CERTIFICATION: YES as shown below: 1. The connecting line has to be chosen according to the maximum temperature for nominal operation (including max. permissible ambient temperature, max. current load and possibly heat conduction). 2. The formation of explosive atmosphere shall be avoided in the area of the magnet core and the guide conduit. 3. The maximum constructional gaps (i c ) are less than the maximum allowed gap as specified in Table 2 of IEC 60079-1 standard. Repair and overhaul of the flameproof gaps are only allowed according constructive information given from the original manufacturer. A repair according the values given in Table 2 of IEC 60079-1 is not permitted. These notes shall be added to each apparatus in suitable form. Page 4 of 5 EQUIPMENT(continued): Key of type designation MG 0.. x - 1 2 3 4 1: Abbreviation: Magnetgehäuse (Enclosure of the magnet) 2: Dimension of the magnet or the solenoid 3: Explosionprotected type 4: Solenoid with pickup- and holding winding Possible types MG 008x MG 010x MG 012x MG 012x-A5 MG 014x MG 014x-A5 MG 016x MG 016x-A MG 016x-A5 MG 018x MG 018x-A1 MG 018x-A2 MG 018x-A5 MG 019x MG 019x-A1 MG 019x-A2 MG 019x-A3 MG 019x-A5

Page 4 of 5

Page 5 of 5 Page 5 of 5 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): New test according to the new revision of IEC 60079-0 (Ed. 4.0), IEC 60079-1(Ed. 5), IEC 60079-7(Ed.4), IEC 61241-0 (Ed.1) and IEC 61241-1(Ed.1). Addition of an X to the certificate number, because the gaps are less than the maximum allowed gap as specified in Table 2 of IEC 60079-1.