Installation Manual RINS1211-4

Similar documents
STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

SECURIT 700L PLUS ENGINEERING MANUAL

THIS GUIDE SUPPORTS MATRIX 424 & 832 CONTROL PANELS

INSTALLATION MANUAL SECURIT 802 CONTROL PANEL

Matrix Installation Manual. Software Version 4. EN Security Grade 2 Environmental Class 2 RINS918-1

Intruder - Fire - Water Combined Alarm

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Gen4 Domestic Intruder Panels RELIABLE AND FLEXIBLE INTRUDER PANELS. Domestic applications

Contents. Introduction... 2 Mains Safety... 2 Good Working Practice... 2

Engineer Reference. EN :2006+A1:2009 EN :2009 EN :2008 EN :2005+A1:2008 Security Grade 2 Environmental Class II

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

Input Type: 42: Medical: This is a 24 Hr type input it will activate the external sounder and report a CID event 100.

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Installation Manual Premier 412/816/832. Issue 10

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Contents. Introduction... 2 Mains Safety... 2 Good Working Practice... 2

TS5160. Installation & User Guide. Compatible Equipment. CPA6 0M - Output Module Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only)

EC-P Zone Intruder Alarm System

Installation Guide for models:

Installation, Operating and Maintenance Manual

FEC400 Series. Installation Manual

Installation Guide for models:

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

CONTENTS. 1 INTRODUCTION 2 Planning the installation 2 Nexus 8 installation example 3

0$; Installation Instructions. Computerized Control Panel '(6&5,37,21 63(&,),&$7,216 DE5011 1

AP10LED 10 Zone onboard LED Alarm Panel. Engineering Manual

Sentry 4 Zone Alarm Panel User Manual

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

M550 and M600. Installation Instructions

KT-100 Door Controller

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

INSTALLATION MANUAL PC56O. Version 1.OA

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

CC408. Quick Reference Guide Solution 880

EVO192 v3.0 Fire and Burglary What s New

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panel with Communicator Interface

Control Panel Engineering and Commissioning Instructions

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. External Sounder & Strobe Unit

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Door Release Power Supply

NESS D24 CONTROL PANEL AND DIALLER INSTALLATION & PROGRAMMING MANUAL

Addendum RINS HONEYWELL. SCANTRONIC / COOPER Input (Programmed as Fault) SCANTRONIC 9600 SCANTRONIC 9651

NESS D8 CONTROL PANEL AND DIALLER

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

ZM1 User Manual JVA TECHNOLOGIES.

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

INSTALLATION GUIDE. For products. Gardtec 370 & 581

PYRONIX LIMITED, Pyronix House, Braithwell Way, Hellaby Rotherham South Yorkshire S66 8QY England

OPERATION AND INSTALLATION MANUAL

SP-1000X. Panic Device Power Controller Installation Guide. Rev

ACP10 & ACP50 Security Systems

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

SDR-WEXT Wired Siren Installation Guide

Power Wave Zone Alarm Panel V8.5. Installation Manual

ZLM4 OEM Technical Manual

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

(Updated Defaults) (Covers Ver: 8.64 and above)

PTE0705 Electric Fence Monitor

Flair 500 Series Annunciators

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

CA60Plus. Installation manual

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

USER MANUAL CEF AP28 CONTROL PANEL

30.45 Electric Release PDRP-2001

Series. Access Power Controllers. Installation Guide

GARDTEC 580. Installation Instructions

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

Version 1.03 January-2002 USER S MANUAL

Model 17A00 Expansion Enclosure

ARROWHEAD ALARM PRODUCTS Ltd. 344b Rosedale Rd, Albany, Auckland. Ph Fax v1.0

M2500 Engine Controller Installation Manual

System Introduction. 1.1 Specifications S E C T I O N 1

HARDWIRED CONTROL PANELS

Fire Control Panel FS4000

AL800ULADA. NAC Power Extender. Installation Guide

System Manual W A R N I N G. PC6O1O Software Version 2.1

SAFETY WARNINGS. Power cable to the alarm system. Automatic two-pole circuit breaker. Cable from power distribution board

Intelligent Security & Fire Ltd

TECHNICAL DATA OBSOLETE

Training Manual with Bi-directional Wireless

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

Access Power Controllers with Power Supplies

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Intelligent Security & Fire Ltd

Quick Programmer s Manual

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

System 800 Addressable Fire Detection & Alarm System

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

4-PGM Expansion Module

5000 SERIES 8 ZONE INSTRUCTION MANUAL

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Transcription:

Installation Manual 2x 2x RINS1211-

Contents Page System Overview Technical Specification 5 Overview 6 The Control Panel 6 The Printed Circuit Board The Tamper Spring and Connections 8 Connections 9 Transformer / Battery Connection 9 Keypad Connection 10 Reader Connection 11 Double Pole - Alarm Connections 12 Double Pole - Tamper Connections 12 DEOL: K Alarm, 2K2 Tamper 13 DEOL: K Alarm, K Tamper 13 Siren Connection 1 Speaker Connection 1 Output Connection/Example 15 Compliance Statement and Warranty 16 Compliance Statement 16 Warranty 16 Input Table Appendix 1 Page:3

System Overview Inputs on main control panel 10 fully programmable inputs Input configuration Input Types Programmable Outputs Output Types Keypad Double end of line (K Alarm, 2K2 Tamper) Double end of line (K Alarm, K Tamper) Double Pole Unused, Fire, Hold Up, 2 Hour, Intruder, Final Exit, Entry Route, ER (FX in part), FX (ER in part), Keyswitch Latched, Keyswitch Pulsed PGM, Bell, Strobe + Outputs on Inputs,8,9 and 10 (programmed either as an input or output) Not Used, Fire, Hold Up Any, Intruder Any, Tamper Any, Set Fail, Entry Deviation, Siren Any, Strobe Any, Exit Starts Any, Final Set Any, Strobe Set Fail, Keyswitch Unset, Entry/Exit, Lights, Restore 1, Restore 2, PIR Latch 1, PIR Latch 2, Mains Good, Detr Indn Enable, Follow Test, Off During Test, Detr Walk Test, Mains Fail, Battery Fault, Low Volts, Global Fault 1, Global Fault 2, Engineer Access Contemporary LCD Keypad 32 Character Number of Keypads Arming Options User Codes Logs Fuses Tampers Timed, Final Door, Timed/Final 30 user codes, 1 Master Manager, 1 Engineer 500 Mandatory, 200 Optional, Bell, RS85 Bus, Battery Case Tamper and Siren Tamper Page:

Technical Specification Electrical Specification Supply Voltage (A.C.) 18VAC Nominal (+-20%), 50Hz (+-10%) Supply Voltage (D.C.) 12VDC Nominal (10-15 Volt DC Range) Power Supply 1A Regulated Supply Current <80mA Quiescent (DC supply, no active outputs) 800mA continous, 13.68V nominal (fold-back Internal battery charger current limited) Battery supply protection Reverse polarity protected Battery final disconnect voltage 10.5V 0-20V, normally closed, normally open, double Zone inputs balanced circuits PGM/SAB outputs Switched negative 1Ah (max) Shared PGM outputs Switched negative 50mA (max) SAB/ supply fuses 800mA quick-blow Battery reverse 1.6A slow-blow protection fuse Mains Fuse Mains Fuse - Anti-Surge 315mA Physical/Mechanical Specification Dimensions 250 x 29 x 82mm Weight 3.0 kilos Environmental Specification Operational temperature -20 C to +60 C range Storage temperature -20 C to +60 C range Electrical Rating: 1A. EN50131-6:199 rating: 85mA when used in Grade 1 system, 65mA when used in Grade 2 system Battery recommend 3Ah or Ah (Max) Page:5

O verview Control Panel The EURO mini is already fully assembled in a metal case. The diagram below shows a basic overview of the different components. The Control Panel Wall Fixing Holes PGM + SPK STB TR B- B+ Z1 GND Z2 GND +12V Z3 GND Z Z5 GND Z6 GND +12V Z GND Z8 Z9 GND Z10 D1- D2+ D3 D - BAT + GND Cable Entry Holes Battery Holder 3Ah or Ah Battery Mains Transformer Fuse carrier handle To Mains Supply Main Cable Entry Hole Mains Fuse Anti-Surge: 315mA Live Earth Neutral Page:6

O verview The EURO mini printed circuit board is as follows: Printed Circuit Board The Printed Circuit Board Power LED (flashes) Fuses PGM + SPK STB TR B- B+ Fuses Double Pole Link The Z1 and Z2 GND terminal cannot be used as 0V PGM Output 1 Z6 Input 6 + +12V Supply COM 0V/Common SPK Speaker Output +12V +12V Supply STB Output 2 Z Input / Output Output 3 COM 0V/Common TR Siren Tamper Return Z8 Input 8 / Output 5 B- 0V Z9 Input 9 / Output 6 B+ +12V Supply COM 0V/Common Z1 Input 1 Z10 Input 10 / Output COM Common Only D1- RS85 Bus: 0V Z2 Input 2 D2+ RS85 Bus: +12V COM 0V/Common D3 RS85 Bus: Data A +12V +12V Supply D RS85 Bus: Data B Z3 Input 3 -BAT Battery Negative COM 0V/Common BAT+ Battery Positive Z Input GND Earth Z5 Input 5 ~ 1V Input COM 0V/Common ~ 1V Input Page:

O verview Tamper Connections The EURO mini printed circuit board is protected by a metal casing. The lid is tampered by a spring that is connected to the printed circuit board. To disable the tamper spring, simply link out the tamper connections shown below. The Tamper Spring and Connections Tamper Connection Tamper Spring PGM + SPK STB TR B- B+ Page:8

C onnections Transformer Battery The transformer will be factory fitted to the connections shown below on the EURO mini. It is recommended that a 3Ah or Ah battery should be used on the EURO mini. This connects to the Battery positive and negative terminals. Transformer / Battery Connection PGM + SPK STB TR B- B+ Battery 12V Transformer To Earth terminal of mains block Page:9

C onnections Contemporary Keypad A maximum of keypads may be installed to the EURO mini. Each keypad (EUR-068 or EUR-069) connects to the RS85 terminal: D1-, D2+, D3 and D. Each keypad must be individually addressed, starting with 00. To do this, press and hold the D key, until KEYPAD CODE is displayed. Enter 2000 and select the appropriate address. Press the YES key to change any other required options, and the A key to save the data. Keypad Connection PGM + SPK STB TR B- B+ 0 0 0ohm Resistor connected to the control panel and to the device which is furthest away D1- D2+ D3 D Page:10

C onnections Internal Tag Reader A maximum of 3 readers may be installed to the EURO mini if the EUR-068 is installed. Each connect to the RS85 terminal: D1-, D2+, D3 and D. Each reader must be individually addressed, starting with 01. To do this, there are dip switches on the back of the reader. Address 32 16 8 2 1 ON 1 2 3 5 6 Reader Connection To address the reader as 02 for example, dip switch 2 must be selected to the right (towards the address number) To address the reader as 01 for example, dip switch 1 must be selected to the right (towards the address number) PGM + SPK STB TR B- B+ 0 0 0ohm Resistor connected to the control panel and to the device which is furthest away D1- D2+ D3 D Page:11

M + SPK STB TR B- B+ C onnections + Double Pole Input Wiring If double pole is used, the link above input 1 (shown below) needs to be open. Double pole requires no resistors, but it requires a dedicated tamper circuit (When a clean start 2002 is performed, input 1 is defaulted as tamper). The first diagram below shows the connection of door contacts/detectors to the EURO mini, the second diagram shows how the tamper circuits of each detector should be connected. The diagrams are split for clearer wiring connections. Please note that any terminal blocks used should be located inside the control panel. Double Pole - Alarm Connections Spare N/C Contact Input 2 This link Door Contact should be OFF +12V GND +12V GND +12V GND Y G R B Y G R B Y G R B Y G Example cable wiring R = Red B = Black Y = Yellow G = Green PGM + SPK STB TR B- B+ Spare N/C Contact Input 2 Door Contact ALARM TAMPER Input 3 Detector Double Pole - Tamper Connections ALARM TAMPER Input Detector ALARM TAMPER Input 5 Detector This link should be OFF Terminal Block (inside control panel) Terminal Block (inside control panel) W Blu W Blu W Blu Example cable wiring W = White Blu = Blue ALARM TAMPER ALARM TAMPER +- +- +- +- +- +- ALARM TAMPER Input 3 Detector Input Detector Input 5 Detector Page:12

C onnections PGM + SPK STB TR B- B+ Resistor Input Wiring If double end of line is used, the link above input 1 (shown below) needs to be closed, and specific resistors need to be used depending on which mode is selected (see Choose Mode in the programming manual). There are 2 choices: DEOL: K Alarm, 2K2 Tamper This link should be ON K 2 K 2 +12V GND K 2 K 2 Spare N/C Contact +- +- ALARM TAMPER Input 1 Door Contact Input 2 Detector DEOL: K Alarm, K Tamper B+ This link should be ON K K +12V GND K K Spare N/C Contact ALARM TAMPER Input 1 Door Contact Input 2 Detector Page:13

C onnections Siren Connection Speaker Connection The connections for a +12V Siren are described below, at default all outputs are negative applied and this cannot be altered. There is also a connection for 1 or 2 16ohm speakers, which will follow the keypad sounds. Siren Connection PGM + SPK STB TR B- B+ +12V Supply 0V Bell Tamper Bell Trigger Strobe Trigger Speaker Connection Siren PGM + SPK STB TR B- B+ 1 or 2 16ohm speakers may be wired in parallel Page:1

C onnections Output Connections The EURO mini supports up to outputs. of the outputs are shared with inputs on the system, therefore if the outputs are used (see Change Outputs in the programming manual), inputs to 10 become disabled. All outputs on the system are negative applied and cannot be altered. The example below shows how to connect a typical 12V dialler. Output Connection/Example PGM + SPK STB TR B- B+ All outputs are negative applied In this example the inputs are programmed as outputs See Change Outputs section in the Programming manual. GND +12V 1 2 3 5 0v +12V Inputs Auxillary Example Auto Dialler Page:15

Compliance Statement and Warranty Compliance Statement The EURO mini complies with the requirements of the EMC Directive (200/108/ EC) and the Low Voltage Directive (2006/95/EC). The EURO mini complies with TS50131-3:2003 Suitable for use in systems installed to PD6662 (AMD2) at security grade 1 or 2X and environmental class 2. 2x TS50131-3:2003 EN50131-1 PD6662:200 Security Grade 2x Environmental Class 2 Warranty This product is sold subject to our standard warranty conditions and is warranted against defects in workmanship for a period of 18 months. In the interest of continuing improvement of quality, customer care and design, Castle Care Tech Ltd reserves the right to amend specifications without giving prior notice. Page:16

Input Table Appendix Input Number Input Type Input Areas Description 1 2 3 5 6 8 9 10 Page:1

Page:18

Page:19

Contact Details Ltd First Floor 6 Bracknell Beeches Old Bracknell Lane West Bracknell Berkshire RG12 BW Helpdesk: 013 6999 Opening Hours:.00am -.30pm Monday to Friday E-mail: support@castle-caretech.com Website: www.castle-caretech.com