Operating Instructions

Similar documents
Super Elite Watch cleaning machine

Operating Instructions

Operating Instructions RM 90. Watch Cleaning Machine. english

Operating Instruction

Operating Instructions

Operating Instructions

Operating Instructions

Operating Instructions

Elmasonic S Ultrasonic cleaning units. The sum of all possibilities

+ English + 1. Safety warnings

Vmusbtpojd!dmfbojoh!xjui!tubuf.pg.uif.bsu!ufdiopmphz

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

Operating Instructions

Operating Instructions!

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

- website: Vax Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire WR9 0QH, UK

MHE001 electric hob. Manual for Installation, Use and Maintenance

Get Cleaning... What s your Vax s model number? User Guide. Carpet Washer Vax Careline: AU: NZ:

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

English CNA-CNB. Centrifugal fans Installation and maintenance

User manual. Fjordblink Birth Pool and Water Supply Unit.

Operating Instructions

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

On/off button with booster (max) function* Fine filter Prefilter. Dust container Release button Charging indicator light. Vacuum cleaning cover

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

Carpet washer. vax.co.uk. W91-RS-B Series W90-RS-B Series. Vax Careline: (UK) (ROI) Vax model number: Version 1.

SK110, SK210 & SK310 Single Ovens Installation, Use and Maintenance

Virtu 60 and 80 series. Coffee machine

Carpet washer. Vax careline V-135B. Vax model number:

TECHNOSKLO Ltd. Držkov

Owner s Manual STAINLESS CONICAL CHIMNEY HOOD CONTENTS

WARNING: Warns of health hazards and identifies possible risks of injury. CAUTION: Indicates possible dangers to the machine or other objects.

1ZSE en, Rev. 4. On-load tap-changers, type UZ User s manual

VETO CLEANER 500 FLUE GAS CLEANER

Flameproof Manual Call Points

Z-800II / Z-1000II / Z-1020 Fog Machine User Manual

Instruction Manual Suppository Penetration Tester. Type PM 30

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

Ropox Bathtub. Keep this manual with the product at all times! User Manual & Mounting Instructions PDF 6128 /

FW821 extra large integrated larder fridge Manual for Installation, Use and Maintenance

MINI FOOD CHOPPER INSTRUCTIONS FOR USE. Thank you for purchasing this product. Please read these instructions carefully before use

Mastro GmbH Hüserstraße Hamm / Germany +49 (0)2381/ (0)2381/

3. Before switching the equipment on, make sure that the model plate data conforms to that of the electrical and water distribution network.

Dual Tank Deep Fryer. Use and Care Instructions. Double Capacity Twice the Power Easy Cleanup

OPERATING INSTRUCTIONS

Get Cleaning... What s your Vax s model number? User Guide. Carpet Washer. Vax Careline: AU: NZ: VCWRS700

VH60SS 60CM VISOR HOOD STAINLESS STEEL

Washing Machine OWNER S MANUAL TRWTL-70. Before using your washing machine, please read this manual carefully and keep it for future reference.

AS 50 operating manual, 2013

ELMA STEAM Medicine Special Accessory

EVG Extractors. Manual for Installation, Use and Maintenance

Virtu 40 series. Coffee machine

COOKER HOOD USER MANUAL

Align holes in retainer plate with the bolt holes on the legs. Start the threading the bolts only partially. You may need to pick up

ENGLISH INSTALLATION AND USER S MANUAL FRENCH NOTICE D INSTALLATION ET D UTILISATION ITALIAN MANUALE D ISTRUZIONE

INSTRUCTIONS AND ADVICE FOR THE USE, INSTALLATION AND MAINTENANCE OF BUILT-IN ELECTRIC HOBS

Pet. Easy Guide. VAX Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK - website:

INSTRUCTIONS FOR USE. To make the most of your new oven, read the user's instructions carefully and keep them on hand for consultation in the future.

VAPORETTINO LUX A B C E. Fig.1 Fig.2 Fig.3 Fig.4. Fig.5 Fig.6 Fig.7 Fig.8. Fig.9 Fig.10 Fig.11. Vaporettino Lux 1R02

TH100 Three in One Instant Hot Water Tap

FW422 Integrated In Column Larder Fridge Manual for Installation, Use and Maintenance

IMPORTANT SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS. WARNING To guard against injury, basic safety precautions USA

Installation Instructions & Operating Manual IMPORTANT

Coffee Machine Zia series

Sip Vacuum Cleaner 1400/35 Wet & Dry

Water Distiller Service Manual

3L STAINLESS STEEL. Features:

INSTRUCTIONS FOR USE

TK 806 Z. Bedienungs- und Wartungshandbuch. Livret d instructions et d entretien. Manuale uso e manutenzione. User instructions and maintenance

Product Manual Glue Applicators MS 80 and MS 200

Vax Careline: Instruction Manual. Vax Model Number V-029 Vax Model Number V-029Q

FLEXIT S4 X/TT - A4 X/TT S7 X/TT - A7 X/TT

Pro6 Duo. Stampa Novaprint - Tel cod USER MANUAL

COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL

WELCOME IMPORTANT SAFEGUARDS

HOT 4000 USER MANUAL. Version 2.1. This manual shall be read in its entirety before using the machine.

PERSONAL COOL MIST ULTRASONIC HUMIDIFIER

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

READ AND SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

REFRIGERAT A OR USE DF1-15 F ridge

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Stoves Cooker Hood User Manual

OPERATING INSTRUCTIONS

Strip-Cut Shredder S5

PC87 American Style Double Door Fridge Freezer Manual for Installation, Use and Maintenance

Kitchen Appliance Lift INSTRUCTION MANUAL

FORMATIC Instruction Manual

ANTIBACTERIAL HAND VAC WITH UV LIGHT

Vacuum cleaner Instruction manual

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

EDD61 & EDD91 Extractors

QTFX-900 mkii Fog Machine. Item ref: UK User Manual

Operating Instructions

FF820 freestanding full height larder fridge Manual for Installation, Use and Maintenance

Bagless upright. Vax Careline (UK) (ROI) vax.co.uk VS-19EC. Vax model number:

Antari Low Fog Machine

Operating Instructions

Operating Instruction Centrifugal fans without scroll (Translation of the Original) BA-RLE-AC /2014 RLE RLA

Transcription:

ENGLISH Operating Instructions Super Elite Watch Cleaning Machine Elma GmbH & Co KG Kolpingstr. 1-7 D-78224 Singen Tel. +49 (0) 7731 / 882-0 Fax +49 (0) 7731 / 882-266 info@elma-germany.com www.elma-germany.com

Contents Contents 1 General... 2 2 Important safety warnings... 3 3 Product description... 3 3.1 CE conformity...3 3.2 Designation of the elements...4 3.3 Technical details...4 4 Putting into Operations... 4 5 Working with the Elma Super Elite... 5 5.1 Placing the watch parts to the cleaned...5 5.2 Cleaning Procedure...6 6 Upkeep of the Machine... 7 7 Putting out of action and waste disposal... 7 8 Manufacturer's contact address... 8 1 General The present Operating Instructions are part of the delivered equipment. They must be ready for use at any time and remain with the unit in case of resale. Reprints, translations and copying of any kind, including of parts of the document, must be authorized by the editor. The copy right remains with the editor. These Operating Instructions are not automatically revised. For the latest revised issue please contact the manufacturer and editor of these Operating Instructions. The manufacturer's address is indicated on the last page of the Operating Instructions. 2 BA/Super-Elite/GB/0104 Elma GmbH & Co KG

ENGLISH Important safety warnings 2 Important safety warnings To be read before initial operation! Intended use Transport damages Mains connection Placement Hot surface Prevention of electrical accidents The Elma Super Elite has been designed for the cleaning of metal items only, e.g. watch pieces. Check the unit and mains cable for transport damages. In case of visible damages do not put the unit into operation. For safety reasons, this electrical appliance must be connected to a correctly grounded socket only. the technical details indicated on the nameplate must correspond with the available mains connection details, in particular those of the mains voltage. Place the unit onto a stable surface. Keep the unit dry! Caution! The surfaces of the heating chamber heat up considerably during operation. Touch the cover at the plastic handle only. The bottom of the drying chamber can reach temperatures exceeding 90 C depending on the period of operation. In order to prevent electrical accidents keep the working surface, the unit and the mains plug dry! Do not put the unit under water! In case of damages on the Super Elite or the mains cable do not connect the unit to the mains! The unit must be opened by authorized and specialized personnel only! Unplug the mains cable before opening the unit! 3 Product description A low-price alternative for the cleaning of disassembled watch works. Charging of the 3 cleaning chambers by hand; drying chamber for the spotless drying of the cleaning items. 3.1 CE conformity The present Elma Super Elite complies with the CE criteria regard to the low-voltage-directive 73 / 23 / EWG (EEC) the EMC directive 89 / 336 / EWG (EEC) the machine-directive 98 / 37 / EWG (EEC). The declaration of conformity is available from the manufacturer. Elma GmbH & Co KG BA/Super-Elite/GB/0104 3

Product description 3.2 Designation of the elements 20 18 12 16 15 17 14 13 7 5 6 11 10 4 19 8 9 3 2 1 3.3 Technical details Mains voltage (as per version) (Vac) 100-120 or 240-240 Mains frequency (Hz) 50 / 60 Power consumption of motor (Watt) 18 Power consumption of heating (Watt) 200 Outer dimensions of unit D / H (mm) 330 / 500 Weight (Kg) 8,7 Material of housing Steel sheet painted 4 BA/Super-Elite/GB/0104 Elma GmbH & Co KG

ENGLISH Putting into Operations 4 Putting into Operations Preparation Filling the jars 1. Compare voltage on type-plate (1) at the machine-hood (2) with the voltage in your workshop. 2. Place the unit onto a stable and dry surface 3. Set up the Machine with the heating tube (3) facing toward you and unscrew the transport safety (5) in the bracket (6). 4. Turn the black turning handle (7) to the front, move the bracket (6) upward till stop is reached. By turning the handle (7) to the back the bracket (6) is fixed. 5. Fill the glass jars (8) in the following order: Fill glass jars (8) to the left of the heating tube (3) with elma cleaning concentrate 1:9 till the first level mark. Dilute up to the end of the hammered mark with ordinary tap-water. Fill the second glass jar with distilled water and the remaining third one with elma suprol spezial. After 50-60 cleanings the solution should be renewed at all events. The rinsing-solution in the last glass jar must always be kept clean. 5 Working with the Elma Super Elite 5.1 Placing the watch parts to the cleaned 1. Put your right hand round the cleaning basket (10) whilst detaching with your left hand by a light turn to the left, the basket flange (11) with suction blades (11) form the cleaning basket. 2. Push out the 3 basket insets in the body with your right forefinger into the hollow of your left hand. Then place the watch parts which must be kept separate according to size and degree of sensitiveness into the various insets. Place these inset again in a body into the basket with the help of your left forefinger. The small round box with cover in the middle of the inset is for the smallest parts. 3. Attach the basket by slightly turning the flange to the right, and lock the basket with the lock decide provided on the flange plate. 4. Plug in the mains cable to a earth protective mains socket. Elma GmbH & Co KG BA/Super-Elite/GB/0104 5

Working with the Elma Super Elite 5.2 Cleaning Procedure Important Proceeding CAUTION All the three glass jars should always be filled up 1 the mark (9). The level of the liquid shall in any case be 1 cm above the suction blade (11). The speed shall be regulated in all three liquids in such manner only that a small suction is formed in the centre above the basket, but the suction blades of the basket flange must not in any case become visible. Otherwise excessive foam formation would occur, and the basket would not be rinsed sufficiently 1. At the every start of each cleaning job switch on the heating chamber (3) by means of the switch (12) separately provided so as to have heating chamber (3) preheated for drying as soon as cleaning in finished. 2. Bring the raised basket (10) into the glass jar (8) filled up with ELMA Solution i.e. at the left of the heating tube (3). Fix the bracket (6) by turning the knob (7) to the left and dip in the basket in the liquid. Switch on the check-clock (17) for controlling the time of cleaning. The cleaning process in the first glass jar takes about 3 to 5 minutes depending on the extent to which the parts are soiled. 3. Start the motor (13) by means of the switch (14) separately provided. 4. Set the speed regulator to slow with the aid of the black knob (15). 5. Before transferring the basket to the first jar to the next then for centrifuging surplus solution raise the basket till the stop is reached by means of the displaceable motor shaft (16) (patent DBP. Nr. 869 025). Thereupon centrifuge for about 30 seconds at full speed. 6. After centrifuging in number 1 glass jar release the bracket (6), move it upward und swing it on to the next jar No. 2 which contains distilled water Repeat the same process i. e. turn the basket in the distilled water for one to two minutes and then again raise up the basket till stop is reached and spin it for one to two minutes. Thereafter place the basket in the third jar, which contains the rinsing-solution. Lift the basket afterwards and go to the heating tube. 7. Place the basket in the heating chamber (3) and dry for 1-2 minutes with raised basket at high speed. Built- in red inspection lamp (20) for controlling the heating. The surface of the heating chamber heat up considerably during operation. The bottom of the heating chamber can reach temperatures exceeding 90 C depending on the period of operation. 6 BA/Super-Elite/GB/0104 Elma GmbH & Co KG

ENGLISH Upkeep of the Machine 6 Upkeep of the Machine Basket insets Grease Motor Mains cable and mains connection Repair Opening by authorized specialized personnel only DANGER lf the cleaning solution is being used over and over again for an excessively long period, the fibres washed out from the soiled watch mechanism, and other dirt such as to bacco particles and the like, will settle down firmly on the tress-work of the bosket. From time to time the basket must, therefore, be cleared of these dirt particle deposit and fibres, which become red by the Elma Solution, be means of a brush and petrol. All the sliding parts of the machine should be cleaned from time to time, and slightly greased (19) and (16). The AC-motor does not require any maintenance. For your own safety, we recommend that you check the mains cable and the mains connection jack at the unit for damage at regular intervals. In case of technical faults please contact your supplier or the manufacturer of the unit. When corresponding in regard to your machine, please give motor serial number. Repair and maintenance works which require the unit to be connected and opened must be carried out by authorized and specialized personnel only. Separate the unit from the mains before opening up the housing. The manufacturer cannot be held responsible for any damage caused by unauthorized repair works. In case of damage please contact the manufacturer or your supplier. 7 Putting out of action and waste disposal The unit can be taken to metal and electronics recycling stations or returned to the manufacturer. Elma GmbH & Co KG BA/Super-Elite/GB/0104 7

Manufacturer's contact address 8 Manufacturer's contact address Elma Hans Schmidbauer GmbH & Co. KG Kolpingstr. 1-7, D-78224 Singen Phone +49 (0) 7731 / 882-0 Fax +49 (0) 7731 / 882-266 e-mail: info@elma-germany.com Homepage: www.elma-germany.com Technical support Phone +49 (0) 7731 / 882-280 Fax +49 (0) 7731 / 882-253 e-mail: support@elma-germany.com Technical and optical changes reserved_elma_ch_01/04 8 BA/Super-Elite/GB/0104 Elma GmbH & Co KG