LTG High Pressure Humidifier and Airwasher

Similar documents
Für Compacting alle Einsatzgebiete. Raumlufttechnik. High Pressure Humidifier and Airwasher Type HPH. Power Screw Type CPS. der dischargeoffinedust

Compact Filter Unit Type CFU

INTELLIGENT HUMIDIFICATION. Two adiabatic humidification methods intelligently combined Condair DL. Humidification and evaporative cooling

LTG Air-Water Systems

Double Intelligence Two adiabatic humidification methods intelligently combined. Humidification and Evaporative Cooling. humidity.

LTG Air-Water Systems

LTG Air-Water Systems

ADVANCE TECHNOLOGIES FOR ADIABATIC COOLING AND HUMIDIFICATION Nortec Humidity, Inc. Fred Valentini Direct Room Systems Regional Manager Randall

CAIRplus ECOTWINcool SUPPLEMENT TO OPERATION MANUAL

Article Energy Saving Benefits of Adiabatic Humidification in the Air Conditioning Systems of Semiconductor Cleanrooms

WATER WITH QUALITY. Hygienic Water Treatment for Humidification Systems. Humidification and evaporative cooling

Product Brochure Air Handling Units with Double-Plate Heat Exchanger CAIRplus SX ECOTWIN cool. Energy efficiency through adiabatic cooling

Atomizing Nozzle Humidifiers. Designed for Air Handling Systems, and Manufacturers, Processors and Distributors of Humidity Sensitive Products.

FUNCTION DESCRIPTION. Air - Humidifier / Air - Washer

PAD. Adiabatic cooler. PAD series

EvaPack SERIES EVAPORATIVE PAD ADIABATIC HUMIDIFIERS

HIGH-PRESSURE ATOMIZING SYSTEM. Humidification and adiabatic cooling. Energy efficient Reduces cooling load Multiple zone capabilities

Direct Room Humidifiers. Humidification and Evaporative Cooling. humidity.com

SUPPLEMENT TO OPERATION MANUAL Modular Air Handling Units CAIRplus ECOTWINcool

EVAPORATIVE COOLING AND HUMIDIFICATION. High-Pressure System Wetted Media System

LTG Air-Water Systems

Development of a Psychrometric Test Chamber. Michael J. Swedish. Associate Professor Mechanical Engineering Department Milwaukee School of Engineering

EVAPACK SERIES EVAPORATIVE PAD ADIABATIC HUMIDIFIERS

Getting Rid of Scale. Nortec RS Series Steam humidifier with patented scale management. Humidification and Evaporative Cooling

ORBIT WING THE BENEFITS SUMMARISED A COMPARISON. MICRO DROP duct humidifier Additional standards:

High-Pressure Atomizing System

Steam Injection Humidifiers for use with steam boilers PR0DUCT CATALOG

Cool, Clean and Comfortable Nortec HP-Series. Adiabatic In-Duct High Pressure Humidification System... Simply Awesome

How about Savings in Time, Money, Energy and Longer Life?

Air Handling Units. Real HVACR people who understand your needs.

OPTIMIZING PERFORMANCE IN SPRAY OPERATIONS

Oil-Less Rotary Screw Compressors

EVAPORATIVE COOLING AND HUMIDIFICATION. High-Pressure System Wetted Media System

GFD. GVD V-shape coil condenser. Güntner Info. 8 additional basic models for container transport!w. V-shape coil drycooler

Humidification Systems Product Guide

CONDAIR ESCO. Live steam humidifier with 100% steam tight rotary valve. Humidification and Evaporative Cooling

CONDAIR ME. In-duct evaporative humidifier and cooler Very low energy operation. Humidification and Evaporative Cooling

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

High-efficiency Turbo Chiller (NART Series)

Midea VFD Centrifugal Chiller Technology

Oil-Less Rotary Screw Compressors Variable Speed. Engineered to Save

Water mist nozzles With anti-drip

H U M I D I F I C AT I O N

LTG Air-Water Systems

Up to 10 zones. Spray directly into the space for high ceiling applications (approximately 30ft/9m)

R07. Answer any FIVE Questions All Questions carry equal marks *****

AL-KO HYGRO-OPT MEMBRANE HUMIDIFIER THE NATURAL ROUTE TO AMBIENT HUMIDITY

humifog Pressurized water humidifi ers

FORMULA. Rotary screw compressors. kw 5,5-7, , bar

Optimizing Electric Humidifier Operation with an Air Side Economizer

PFS Single stage axial fan The axial fan for modern boiler plants

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

Performance Rating of Commercial and Industrial Humidifiers

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

Steam Injection Humidifiers for use with steam boilers PRODUCT CATALOG

TEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

Maintain. a TOWER of POWER. Part One How to. Don t let out of site, out of mind prevent you from keeping cooling towers running efficiently

LOW STATIC HYDRONIC DUCTED UNIT

Armstrong Cool-Fog Systems

Recirculated air ceiling for operating rooms made by Krantz Components

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

AIR HANDLING UNITS MANDÍK

MODEL SW-2. Sample specifications for SW-2 SPECIFICATIONS

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

VARIO eco Dust Collector. For the highly effective, energy efficient collection of dust from industrial processes. Standard for clean air

MELA dem Everything you need for water treatment

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

TOPAZ ADIABATIC COOLER

Rotary screw compressors

Fans Air handling units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Air Humidifiers For DV Air Handling Units

INTELLIGENT SOLUTIONS FOR ADIABATIC COOLING IN DATA CENTERS

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

JETSPRAY. Compressed air and water spray humidifier Guaranteed drip free. Humidification and Evaporative Cooling

Supplying Clean Air to Industry

THE SIX STEPS OF HUMIDIFICATION DESIGN

Key benefits. Why Condair Dual2?

Filtering Ideas, Making Innovations

Air-Handling System Cooling Options

Products 2017 / 2018

Facade Fan Coil Unit Type FVD/FVDplus

Wet ElectroStatic Precipitator

Proven features for humidification in ventilating and air-conditioning systems

Masters in energy efficiency

[1] Lecture 2 Particulate emission control by mechanical separation & wet gas scrubbing

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

EN aquatech.piovan.com

Softcool evaporative cooling

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

Rotary screw compressors

INNOVATIVE HVAC SOLUTIONS FOR AN AUTOMOTIVE PLANT IN SOUTHERN ITALY

Venturi wet scrubber VDN Separation of combustible, explosive, humid and adhesive dusts

Dhulapally, Secunderabad Subject: REFRIGERATION AND AIR CONDITIONING QUESTION BANK

Modular Supply Make-Up Air Unit

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Desiccant Cooling with Solar Energy

Centeral Station Air Handling Unit

100% NON-WETTING jumbo non-clogging orifce. PRECISE HUMIDITY CONTROL Evaporative cooling LOW MAINTENANCE

Transcription:

LTG Compacting Luftauslässe Power Screw Type CPS Für Compacting alle Einsatzgebiete dischargeoffinedust der Raumluft- and technik and short fibres Technical Documentation

Function The LTG High Pressure Humidifier works with fresh water that is sprayed and atomized at a high pressure. This atomization is so intensive that a mist is created. The fine water droplets evaporate very quickly and have an adiabatic cooling effect. The excess droplets (on average about 25% of the sprayed water quantity) are separated from the air by a special drop eliminator. For this reason, very little water is recirculated. The humidification requirement determines the amount of water that has to be atomized. The water quantity can be controlled with the speed of the high-pressure plunger pump by using a frequency inverter. The LTG high-pressure atomizing nozzles build up a resistance depending on the water quantity. This resistance permits efficient atomization in the first place. The high-pressure atomizing nozzles are operated between 10 and 120 bars (145-1700 psi). To prevent fouling of the humidifier and the air ducts, clogging of the high pressure atomizing nozzles and to prevent minerals from depositing in the room, it is important to have adequate water quality. LTG has the benefit of a long experience with many installations, and also works closely with water treatment companies. This gives LTG the competence to propose the optimum water treatment process. Water quality also has a bearing on hygiene, fouling of the systems, air purity, humidification efficiency and water consumption. Advantages - Energy savings Compared with the conventional recirculating spray humidifier/air washer, there is an 85% pump energy savings (with x of 4.5 g/kg of dry air). Compared with a steam humidifier, there is a 99% energy savings when taking steam generation into account, plus a saving of up to 50% of chiller energy due to adiabatic cooling. - Hygiene Only fresh water is atomized, and not recirculated water, which prevents the accumulation of germs. The housing is sloped to dry it, which in turn eliminates lengthy downtimes. - No touch system Thanks to the strict water quality requirements, there are no problems caused by lime scale in the humidifier. All maintenance can be performed completely outside the humidifier (oil change, filter cartridge change), and therefore almost no downtime is required. - Efficient Control Thanks to the inverter-controlled high-pressure pump, the humidification capacity can be controlled quickly and accurately. - Reduced water requirement High bleed-in factors that are required for the recirculating spray humidifier are not necessary, since the water used has been treated. Overall, the extra cost for water treatment pays off. housing with pump-and filter unit High-pressure nozzles Grenzstraße 7 70435 Stuttgart Germany HPH-eng-TP (06/13) Printed in Germany Former editions are invalid Subject to technical modifications page 2 of 8

Applications - Building air conditioning For office buildings, the hygienic alternative to the recirculating spray humidifier. Also suitable for use in hospitals, as a substitute for steam humidifiers. - Hygiene industry Where hygiene is important for the production process, germs and minerals cannot be tolerated. The treated water is risk free, and eliminating the water tank of the air washer also has a positive effect. - Chemical industry Maintaining specified air conditions within a narrow range is essential for best production results here, and since the materials used are impervious to aggressive components in the air, this is an ideal field of application. - Tobacco industry In this industry too, the hygiene regulations are being tightened. Without recirculating water, there is no accumulation of organic particles in the water. - Textile industry Heat loads from the production process have to be reduced here, and a constant relative humidity is required. High degrees of air saturation reduce the air quantity needed to do so. - Surface treatment For an optimum and even drying of sheet metal parts, conditioning of the supply air has to be absolutely constant. Furthermore, no minerals should migrate into the drying process. - Printing Industry To avoid electrostatic charge of the paper, a constant relative humidity of the production process is necessary. Components - Enclosure of reinforced fiberglass or stainless steel Used for years in conventional recirculating spray humidifiers; baffles and eliminator blades made of PPTV with a stainless steel holding structure. - Nozzle bank Made of stainless steel, with stainless steel atomizing nozzles, generating a fine mist (SMD 20 m at 70 bars). operated between 10 and 120 bars (145-1700 psi). - High pressure pump Brass or stainless steel version depending on the water quality, but in either case with ceramic plunger with dry running prevention, supply stop and pressure monitoring, operating up to 120 bars (1700 psi). - Water treatment Depending on the supply water quality, fine filter, softening and reverse osmosis is required. - Control panel Equipment control panel with frequency inverter and safety functions. Sizes Air quantities 20 000 to 500 000 m 3 /h 12,000 to 300,000 cfm Housing dimensions: Width 1500 to 5000 mm 5' to 16' Height 1500 to 5000 mm 5' to 16' Length 1750 or 3000 mm 10' or 5'-9 Airflowvelocity: 3to6m/s 600 to 1200 fpm For high humidification ratios in addition to tight control accuracies, two nozzle banks are used. Grenzstraße 7 70435 Stuttgart Germany HPH-eng-TP (06/13) Printed in Germany Former editions are invalid Subject to technical modifications page 3 of 8

Water consumption/energy consumption 200 Comparison of the water consumption of different humidification systems 180 175 160 Water consumption in % 140 120 100 80 60 100 71 96 67 67 40 20 0 air washer, flush rate 1:1, set to maximal demand air washer, flush rate 1:1, conductivity control High Pressure Humidifier, 4 m/s, 100 % humidification, 30 % loss, High Pressure Humidifier, 4 m/s, 100 % humidification, 30 % loss, 25 % loss by reversed osmosis humidifier with compressed air nozzles,, 25 % loss by reversed osmosis steam humidifier, 25 % loss by reversed osmosis Comparison of the energy consumption of different humidification systems 2000 1990 1800 1600 Energy consumption in % 1400 1200 1000 800 600 400 200 0 100 air washer, 4 m/s, 4,5 bar, 100 % humidification, yearly mean 2g/kg 13 19 High Pressure Humidifier, 4 m/s, 100 % humidification, 30 % loss High Pressure Humidifier, 4 m/s, 100 % humidification, 30 % loss, additional water treatment 25 % loss 129 humidifier with compressed air nozzles steam humidifier Grenzstraße 7 70435 Stuttgart Germany HPH-eng-TP (06/13) Printed in Germany Former editions are invalid Subject to technical modifications page 4 of 8

Water treatment The LTG High Pressure Humidifier requires a certain water quality, to increase the intervals between necessary maintenance, to eliminate nutrients for germ growth, and to achieve best atomization. If the results of the water analysis are outside the required limits, the water needs additional treatment besides ultrafine filtration. Above a hardness of 5 degrees, a softening device must be provided. Above a certain total mineral content, a demineralization unit, working on the reverse osmosis principle, must be installed in addition. It is however sufficient to mix the water to bring it below the limit. Water requirements for recirculating water as used by standard air washers An important and easily measured value is the electrical conductivity of the water. This conductivity is an indicator for the overall mineral content of water. The limit value for the electrical conductivity is 1000 S/cm for standard air conditioning. Requirements, 300 S/cm for data processing rooms and 120 S/cm for clean rooms. This means that the water in the supply tank must not exceed these limit values. To minimize the water quantity that has to be replaced through bleed-in, the supplied water must be considerably below these limits regarding conductivity. To avoid having to bleed in more than the quantity that evaporates, the electrical conductivity must be less than 500 S/cm. Nevertheless, the possibility of accumulation of germs in the recirculating spray humidifier remains. Different possibilities of water treatment fine filter softener and fine filter softener, fine filter and reversed osmosis Grenzstraße 7 70435 Stuttgart Germany HPH-eng-TP (06/13) Printed in Germany Former editions are invalid Subject to technical modifications page 5 of 8

Pump-, filter- and control-unit 1.5 to 7.5 kw 11 kw, 15 kw 2to10hp 15hp,20hp Dimensions: Dimensions: Height:1880 mm (74 inch) Height: 1880 mm (74 inch) Width: 725 mm (28.5 inch) Width: 1170 mm (46 inch) Depth: 500 mm (19.7 inch) Depth: 625 mm (24.6 inch) Grenzstraße 7 70435 Stuttgart Germany HPH-eng-TP (06/13) Printed in Germany Former editions are invalid Subject to technical modifications page 6 of 8

Sanitation Certificate Grenzstraße 7 70435 Stuttgart Germany HPH-eng-TP (06/13) Printed in Germany Former editions are invalid Subject to technical modifications page 7 of 8

Comfort Air Technology Air Conditioning Systems Decentralized Facade Ventilation Units Fan Coil Units Induction Units, Active Chilled Beams Air Diffusers Linear Air Diffusers Wall and Floor Mounted Air Diffusers Swirl Diffusers Industrial and Special Air Diffusers Air Distribution Flow Rate and Pressure Controllers Shut-off and Balancing Dampers Silencers 1.Dient zur Identifizierung der letzten Seite Process Air Technology Fans Tangential Fans Axial Fans Centrifugal Fans Fahrtwind-Simulators Filtration Technology Suction Nozzles Dampers Filters, Dust Collectors Separators, Compactors Humidification Technology Air Humidifiers Product Humidifiers Engineering Services Fluid Engineering Flow analysis Flow visualization CFD-simulations Flow optimization Air conditioning concepts Thermodynamics Calorimetric performance measurement Thermal, dynamic, unsteady, system simulations Acoustics Sound level measuring Vibration analysis Echo chamber measurement Acoustic optimization Comfort Evaluation Optimization Customer-specific Solutions Product development Process optimization Installation analysis Grenzstraße 7 70435 Stuttgart Germany Tel.: +49 (711) 8201-0 Fax: +49 (711) 8201-696 E-Mail: info@ltg-ag.com www.ltg-ag.com LTG Incorporated 105 Corporate Drive, Suite E Spartanburg, SC 29303 USA Tel.: +1 (864) 599-6340 Fax: +1 (864) 599-6344 E-Mail: info@ltg-inc.net www.ltg-inc.net HPH-eng-TP (06/13) 451-10