Light oil burners. One stage operation

Similar documents
Oil burners Brûleurs fioul Stookoliebranders

Light oil - kerosene burner

Parts Available from

Light oil / kerosene burner

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

Forced draught gas burner

Single stage operation oil burner

TWO STAGE HEAVY OIL BURNERS

Forced draught gas burner

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Single stage operation oil burner

15 20 kw kw kw

Installation & Maintenance Manual

Gas-Gebläsebrenner Brûleur gaz à air soufflé Forced draught gas burner Gasventilatorbrander Quemador de gas de aire soplado

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

RETROFIT APPLICATIONS ONLY

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 10 E R

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Installation, use and maintenance instructions. Kerosene burner. One stage operation CODE MODEL TYPE RDB2.2 FIREBIRD C20 70K DGT 744LD2X

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction MOL1650 T3N 323 2FH.

Installation and operating instructions B1FUV Classic

Infrared Diesel Heater

ST 40 Oil Burner. Installation & Maintenance Manual

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A

RIELLO 40 GS/M SERIES

Single stage operation oil burners

INSTALLATION AND MANINTENANCE INSTRUCTIONS

Installation and operating instructions B2KSV Classic

Forced draught natural gas/propane burner

Installation & Maintenance Manual

Oil TRIANCO. EuroStar Range BURNER DETAILS TRIANCO - OIL BURNER. To be retained by householder

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

BIX B-One 100 kw INSTALLATION GUIDE

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 45A

DOMESTIC WATER HEATER OIL FIRED

Single stage operation forced draught natural gas/propane burner

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

RETROFIT APPLICATIONS ONLY

CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50

Grant UK VortexBlue. 21, 26 and 36kW Blue Flame Oil Boiler Range. Supplementary Installation, Servicing and User Instructions

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 45 A2.2

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION AND OPERATION MANUAL

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

OPERATING & MAINTENANCE MANUAL INDUSTRIAL DIRECT FIRED DIESEL/KEROSENE HEATERS IC 25

Installation, use and maintenance instructions. Light oil burner. Two stage operation CODE MODEL TYPE RL X (1) - 08/2012

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

Technical information. Remeha P200. Pressurized boiler. Heat output: kw

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Heating Equipment. gas boilers RX GB. installation and servicing instructions

IDEA SERIES LIGHT OIL BURNERS LO280 LO400

RL 28/2-38/2-50/2 Low - High Operation

DH-Direct Fired Poultry Farm Diesel Heater

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

1. GENERAL SAFETY RULES

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

INSTALLATION AND OPERATING INSTRUCTIONS JAKA HFD JAKA HFS

Capri B Cast iron combination oil-fired boiler with water tank

PEGASUS F2 N 2S. CAST IRON GAS BOILER for heating with electronic ignition and flame control INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE

Capri R CH only, oil-fired, cast iron boiler

Propane Heater REMKO PGM 30 REMKO PGM 60

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

EURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR..

Utility and Utility System Floor Standing Condensing Oil Boiler Range ADDENDUM ATTENTION INSTALLERS - UPDATED INFORMATION!

IST 03 C ELBA DUAL INSTALLATION, USE AND MAINTENANCE

en Direct oil-fired space heaters HD... Operator's manual

Forced draught gas burners

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

Columbia Boiler Company

BC Series II OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR US AND CANADIAN SALES

External Module Floor Standing Condensing Oil Boiler Range ADDENDUM ATTENTION INSTALLERS - UPDATED INFORMATION!

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-400TRLT INDIRECT FIRED HEATER TRAILER

MANUAL OF - INSTALLATION - OPERATION - MAINTENANCE HEAVY OIL BURNERS

UV Flame Supervision System

Dual fuel gas oil/ gas burners

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

Indirect gas-fired air heater

Weishaupt WG10 and WG20 gas burners LN (Low NO x ) version 2/2002 CA

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

USERS MANUAL FOR GAS BOILERS

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

INSTALLATION & SERVICING MANUAL FOR WARMFLOW OIL FIRED WARM AIR HEATERS MODELS WAH 100/150 WAH 200/300 WAH 500/600

INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A

RL 70/2-100/2-130/2 Low - High Operation

40 SERIES GAS BURNER MODEL 400 NATURAL GAS/PROPANE INSTALLATION INSTRUCTIONS AND OWNER S HANDBOOK

CONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Installation & Maintenance Manual

- Instruction for ligth oil burner models BTS /05. Edition

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

Transcription:

Installation, use and maintenance instructions Light oil burners One stage operation CODE MODEL TYPE 3505 RDB CF 38 50 T3 350050 RDBR CF 6 50 TR 35050 RDBR CF 33 50 TR 35050 RDBR CF 38 50 T3R 350650 RDBR CF 38 50 T3R 350750 RDBR CF 46 50 T5R 90 (3) - 06/009

CONTENTS. BURNER DESCRIPTION............. Burner equipment.................. TECHNICAL DATA................. Technical data..................... Working fields.....................3 Overall dimensions................ 3 3. INSTALLATION................... 3 3. Boiler fixing...................... 3 3. Hydraulic systems................. 4 3.3 Electrical wiring................... 5 4. WORKING....................... 6 4. Combustion adjustment.............. 6 4. Nozzles recommended.............. 6 4.3 Electrodes setting.................. 7 4.4 Pump pressure.................... 7 4.5 Air damper adjustment.............. 7 4.6 Fuel heating...................... 7 4.7 Burner start-up cycle................ 7 5. MAINTENANCE................... 8 6. FAULTS / SOLUTIONS............. 9. BURNER DESCRIPTION One stage gas oil burner. The burner meets protection level of IP 40, EN 6059. Burner with CE marking in conformity with EEC Directives: EMC 89/336/EEC - 004/08/CE, Low Voltage 73/3/EEC - 006/95/CE, Machines 98/37/EEC and Efficiency 9/4/EEC. CE Certification No.: 0036 036/0 as 9/4/EEC. 4 5 Fig. 6 7 8 3 D4044 Pump Flange with insulating gasket 3 Air damper adjustment screw 4 Reset button with lock-out lamp 5 Photoresistance 6 Control-box 7 Pump pressure adjustment screw 8 Pressure gauge port. BURNER EQUIPMENT Flange with insulating gasket.... No. Screws for flange to be fixed to boiler........ No. 4 Screw and nuts for flange...... No. Flexible oil pipes with nipples.............. No.

. TECHNICAL DATA. TECHNICAL DATA TYPE 50T3 50TR 50TR 50T3R 50T3R 50T5R Output kg/h 3..4..8.8 3. 3..8 3.9 Thermal power kw 3.8-37.9 6.6-6.4-33. 3.8-37.9 3.8-37.9 33. - 46. (with air at 0 C) (H i =.86 kwh/kg) Fuel Gas oil, viscosity 4 6 mm /s at 0 C Electrical supply Single phase, ~ 50Hz 30V ± 0% Motor Run current 0.7A 850 rpm 98 rad/s Capacitor 4.5 µf Ignition transformer Secondary 8 kv 6 ma Pump Pressure: 8 5 bar Absorbed electrical power 0.5 kw 0.70 kw 0.80 kw. WORKING FIELDS (as EN 67) Pressure in the combustion chamber mbar..0 0.8 0.6 0.4 0. 0. 50TR 50TR 50T3 50T3R.4.6.8..4.6.8 3 3. Fuel output - kg/h D670 6 8 0 4 6 8 30 3 34 36 38 Thermal power - kw.4 Pressure in the combustion chamber mbar..0 0.8 0.6 0.4 0. 50T3R 50T5R 0.8..4.6.8 3 3. 3.4 3.6 3.8 4 Fuel output - kg/h D67 4 6 8 30 3 34 36 38 40 4 44 46 48 Thermal power - kw

.3 OVERALL DIMENSIONS Flange 80 36 Burner 40 86 0 45 45 7 7 3.5 68 ø 89 30 D4049 50 0 D4085 3. INSTALLATION THE BURNER MUST BE INSTALLED IN CONFORMITY WITH LEGISLATION AND LOCAL STANDARDS. 3. BOILER FIXING Put on the flange () the screw and two nuts, (see fig. ). Fix the flange () to the boiler door (4) using screws () and (if necessary) the nuts (3) interposing the insulating gasket (5), (see fig. 3). Fig. 5 3 E948 Fig. 3 4 E949 3

3. HYDRAULIC SYSTEMS The pump is designed to allow working with two pipes. In order to obtain one pipe working it is necessary to unscrew the return plug () (fig. 4), remove the by-pass screw (3) and then screw again the plug (). WARNING The suction plug () is made of plastic. Once removed, it must not be used again. In single-pipe installations, the plug in the return line () must be totally in steel. In the two pipes systems, before starting the burner make sure that the return pipe-line is not clogged. An excessive back pressure would cause the damage of the pump seal. A metal bowl filter with replaceable micronic filter must be fitted in the oil supply pipe. Check periodically the flexible pipes conditions. PRIMING PUMP On the system in fig. 5 it is sufficient to loosen the suction gauge connection (6) (fig. 4) and wait until oil flows out. Fig. 4 8 7 6 5 4 3 min. 0. m H max. 4 m Fig. 5 H meters 0.5.5 L meters I.D. 8 mm I.D. 0 mm 0 0 0 40 40 80 60 00 D9630 Suction line Return line 3 By-pass screw 4 Gauge connection 5 Pressure adjuster 6 Suction gauge connection 7 Valve 8 Auxiliary pressure test point D574 On the systems in fig. 6 and 7 start the burner and wait for the priming. Should lock-out occur prior to the arrival of the fuel, await at least 0 seconds before repeating the operation. WARNING The pump suction should not exceed a maximum of 0.4 bar (30 cm Hg). Beyond this limit gas is released from the oil. Oil pipes must be completely tight. In the vacuum systems (fig. 7) the return line should terminate within the oil tank at the same level as the suction line. In this case a non-return valve is not required. Should however the return line arrive over the fuel level, a non-return valve is required. This solution however is less safe than previous one, due to the possibility of leakage of the valve. H D84 max. 4 m Fig. 6 Fig. 7 H meters H max. 4 m D5740 0 0.5.5 3 3.5 I.D. 8 mm 35 30 5 0 5 8 6 L meters I.D. 0 mm 00 00 00 90 70 30 0 H H H = difference of level; L = max. lenght of the suction line; I.D. = interminal diameter of the oil pipes 4

3.3 ELECTRICAL WIRING WARNING DO NOT EXCHANGE NEUTRAL WITH PHASE ~ 50Hz - 30V ~ 50Hz - 30V PE N L 50T3 PE N L 50TR-R-3R - 50T3R-5R Main switch Main switch T6A T6A Neutral Safety thermostat Limit thermostat Remote lock-out signal (30V - 0.5A max.) Ignition electrodes Neutral Safety thermostat Limit thermostat Remote lock-out signal (30V - 0.5A max.) Ignition electrodes CONTROL BOX 535SE/LD CONTROL BOX 535RSE/LD M M D604 Photoresistance Photoresistance NOTES: Blue White Black Motor M Oil valve Capacitor Start thermostat Resistance White Wires of min. mm section. (Unless requested otherwise by local standards and legislation). The electrical wiring carried out by the installer must be in compliance with the rules in force in the Country. D607 Black Blue White Black Motor M Oil valve Capacitor TESTING: Check the shut-down of the burner by opening the thermostats and the lock-out by darkening the photoresistance. Fig. 8 4 CONTROL BOX (see fig. 8) To remove the control box from the burner follow of the istruction: Loosen the screw (), open the protection () and remove all components. Remove the coil (3). Loosen the two screws (4). Move a little the control box and remove the high voltage leads. 3 4 E950 5

4. WORKING 4. COMBUSTION ADJUSTMENT In conformity with Efficiency Directive 9/4/EEC the application of the burner on the boiler, adjustment and testing must be carried out observing the instruction manual of the boiler, including verification of the CO and CO concentration in the flue gases, their temperatures and the average temperature of the water in the boiler. To suit the required appliance output, fit the proper nozzle, then adjust the pump pressure and the air damper opening in accordance with the following schedule. The values shown in the table are measured on a CEN boiler (as per EN 67). They refer to.5% CO at sea level and with gas oil and room temperature of 0 C. 50T5R 50T3R 50T3R 50TR 50TR 50T3 TYPE Nozzle Pump pressure Burner output Air damper adjustment GPH Angle bar kg/h ± 4% Set-point 0.50 60.0 3.3 0.55 60. 4.5 0.60 60.4 4.8 0.65 60.6 5.5 0.75 60 3.0 6.5 0.75 60 3.5 3. 7.5 0.40 60 0.5.4 0.8 0.50 60.9.8 0.55 60. 3.8 0.55 60 3. 5 0.50 60.8 3.3 0.50 60.9 3.5 0.55 60. 4.3 0.60 60.3 4.7 0.65 60.5 5. 0.75 60.8 6 0.55 60.0 3. 0.60 60.3 4. 0.65 60.5 4.8 0.75 60.9 6.3 0.85 60.5 3. 7.5 0.55 60.0 3.4 0.60 60.3 4 0.65 60.5 4.6 0.75 60.9 5.4 0.85 60.5 3. 6.5 0.75 80.8.5 0.85 60 3.3..00 60 3.8 3.6.00 60.5 3.9 3.8 4. NOZZLES RECOMMENDED : Delavan type W - E ; Monarch type R - NS Steinen type Q - H ; Danfoss type S - H. 6

4.3 ELECTRODES SETTING ATTENTION Before removing or assembling the nozzle, loosen the screw (A, fig. 9) and move the electrodes ahead. Fig. 9 4 ± 0.3 mm IMPORTANT: THESE DIMENSIONS MUST BE OBSERVED D530 A.5 mm 4.4 PUMP PRESSURE: bar: The pump leaves the factory set at this value. 4 bar: (Only for type 50T3). Improves flame retention; it is therefore suitable for ignitions at low temperatures. 4.5 AIR DAMPER ADJUSTMENT The settings indicated in the schedule are purely indicative. Each installation however, has its own unpredictable working conditions: actual nozzle output; positive or negative pressure in the combustionchamber, the need of excess air, etc. All these conditions may require a different air-damper setting. 4.6 FUEL HEATING (for type 50TR-R-3R - 50T3R-5R) In order to assure regular ignition and working also at low temperatures the burner has an oil pre-heater fitted in combustion head. The pre-heater starts when thermostats close and it is indicated by the ignition of an orange led placed on the control box. When the required temperature for ignition is reached the thermostat fitted on the nozzle holder starts the burner the orange led switches off, the green led switches on and the motor starts. The pre heater remains energised during working and cuts out when burner shuts-down. 4.7 BURNER START-UP CYCLE Thermostat Motor Ignition transformer Oil valve Flame Lock-out lamp Normal 50T3 Lock-out due to failure to light B ~ s ~ s ~ 5s D59 Thermostat Resistance Motor Ignition transformer Valve Flame Lock-out lamp Normal 0 50s 50TR-R-3R - 50T3R-5R Lock-out due to failure to light B ~s 0 50s ~s ~5s D539 B Lock out is indicated by a lamp on the control box (3, fig., page ) 7

5. MAINTENANCE The burner requires periodic maintenance carried out by a qualified and authorised technician in conformity with legislation and local standards. Maintenance is essential for the reliability of the burner, avoiding the excessive consumption of fuel and consequent pollution. Before carrying out any cleaning or control always first switch off the electrical supply to the burner acting on the main switch of the system. THE BASIC CHECK ARE: Check that there are not obstructions or dents in the supply or return oil pipes. Clean the filter in the oil suction line and in the pump. Clean the photoresistance, (5, fig., page ). Check for correct fuel consumption. Replace the nozzle and check the correct position of electrodes (fig. 9, page 7). Clean the combustion head in the fuel exit area, on the diffuser disc. Leave the burner working without interruptions for 0 min. and set rightly all the components stated in this manual. Then carry out a combustion check verifying: Smoke temperature at the chimney; Content of CO (%); Content of CO (ppm); Smoke value according to opacity smokes index according to Bacharach scale. 8

6. FAULTS / SOLUTIONS Here below you can find some causes and the possible solutions for some problems that could cause a failure to start or a bad working of the burner. A fault usually makes the lock-out lamp light which is situated inside the reset button of the control box (3, fig., page ). When lock out lamp lights the burner will attempt to light only after pushing the reset button. After this if the burner functions correctly, the lock-out can be attributed to a temporary fault. If however the lock out continues the cause must be determined and the solution found. FAULTS POSSIBLE CAUSES SOLUTION Check presence of voltage in the clamps of the plug. The burner will not start when the adjustment thermostat closes. Burner runs normally in the prepurge and ignition cycle and locks out after 5 seconds ca. Burner starts with an ignition delay. Lack of electrical supply. The photoresistance sees false light. Resistance or start thermostats are faulty. The connections in the control box are wrongly inserted. The photoresistance is dirty. The photoresistance is defective. Flame moves away or fails. The ignition electrodes are wrongly positioned. Air output is too high. Nozzle dirty or worn. Check the conditions of the fuses. Check that thermostat limit is not lock out. Eliminate the light. Replace them. Check and connect completely all the plugs. Clear it. Change it. Check pressure and output of the fuel. Check air output. Change nozzle. Check the coil of solenoid valve. Adjust them according to the instructions of this manual. Set the air output. Replace it. WARNING The manufacturer cannot accept responsibility for any damage to persons, animals or property due to error in installation or in the burner adjustment, or due to improper or unreasonable use or non observance of the technical instruction enclosed with the burner, or due to the intervention of unqualified personnel. 9

RIELLO S.p.A. I-37045 Legnago (VR) Tel.: +39.044.630 http:// www.rielloburners.com Subject to modifications