START-UP TRAINING AND INSTRUCTIONS HURRICHILL BLAST CHILLERS

Similar documents
MODULAR SERIES BLAST CHILLERS & SHOCK FREEZERS. Installation & User s Manual

MODULAR SERIES BLAST CHILLERS & SHOCK FREEZERS. Installation & User s Manual

BLAST CHILLER / SHOCK FREEZER MODEL AP3BCF30-1

BLAST CHILLER / SHOCK FREEZER MODELS AP20BC200-2 AND AP20BCF200-2

BLAST CHILLER / SHOCK FREEZER MODEL AP20BCF200-3 (with 1 heated food probe)

Why use Blast Chiller or Freezer?

Blast Chiller and Shock Freezer Systems

BLAST CHILLER / SHOCK FREEZER MODEL AP10BCF100-2

Installation and Operation Guide For

SUPERIOR COLD TEMPERATURE SOLUTIONS REFRIGERATION

TRAULSEN BLAST CHILLERS Models: TBC5, TBC13, TBC1H & TBC1HR. training guide

User Manual

Blast Chillers & Blast Freezers. From the world of Comcater!

CHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX

BLAST CHILLERS & BLAST CHILLER/FREEZERS

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

BLAST CHILLERS BENEFITS

HIGH QUALITY REFRIGERATION AT ATTRACTIVE PRICES

Blast chillers. After this quick introduction, a detailed description of blast-chilling and freezing adavantages is provided. WHY USE A BLAST CHILLER?

IMPORTANT PLEASE RETAIN FOR YOUR RECORDS

Blast Chillers / Freezers. EasyChill T3 E5 E10 E15 E15.2 E20 T20-R T20-C+ T30 T40 T50

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

Installation and Operation Guide For MCF-49FD, MCF-23FD MCR-49FD, MCR-23FD

User Manual. Commercial Chest Freezer User s Manual 360CF5, 360CF8, 360CF14, 360CF18

UNDERCOUNTER LABORATORY FRONT BREATHING REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

COMMERCIAL REFRIGERATOR AND FREEZER USER S MANUAL

Instruction Manual. Chest Freezer. Model: ACFM050ADB INSTALLATION INSTRUCTIONS. Before Using Your Freezer Remove the exterior and interior packing.

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

MANUAL. Instructions for installation use & general maintenance of your HORIZONTAL FREEZER HFF, FLORENCIA and MILAN Product Lines MAN-017-R

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

MASTER-CHILL ROLL-IN & PASS-THRU BLAST CHILLERS/FREEZERS

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

Owner s Manual. Walk-in Monitoring System 100B. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies

Blast Freezers and Chillers for Ice Cream Parlors, Confectioners, Bakeries, Delicatessens and Restaurants

BOTTOM MOUNT REFRIGERATORS & FREEZERS Installation, Operation and Maintenance Instructions

The next level to boost your sales.

Operator s Manual. Frozen Beverage Granita Machines

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

MCR & MCR SERIES Roll-in & Pass-Thru Blast Chillers

BUILT-IN OVEN MODEL: EBO-E7081D(SS) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference.

BOHEC. Fast & Plus. Series. Blast chillers and freezers for bread-, pastry- and ice cream-making BAKING

PERFORM Operating Document. General maintenance of Stoves, Fridges and Pots and Pans in the Nutrition Suite

Blast Chiller/Shock Freezers

Operators and Service Manual

AACH50 1/2 HP GALLONS (200 TO 1200L) INSTRUCTION MANUAL

Installation & Operations Manual. Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800) REV: LN PN

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

OPERATING INSTRUCTIONS:!

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

Korean Side-by-Side Refrigerator Use and Care Manual

User Manual. Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D. Commercial Reach-In Freezers: FZ-1D, FZ-2D

HR6BMFF320 HR6BMFF320S

Beverage Air IMPORTANT

HOUSEHOLD FREEZER 048-GM-48303/048-GM-48304/048-GM-48305

BUILT-IN OVEN MODEL: EBO-D7080D(SS) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference.

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

User Manual. Commercial Refrigerator And Freezer User s Manual

BOTTLE COOLERS SLIDE TOP INSTALLATION AND OPERATION INSTRUCTION MANUAL MODEL SERIES BC24- BC36- BC48- BC72- BC96-

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

Use and maintenance manual BLAST CHILLERS/SHOCK FREEZERS KING TROLLEY. Rev.7-7

AG2TEMP PRESTIGE SPECIAL REFRIGERATOR Model: AG2TEMP SPECIAL

Upright Freezer 048-GM-48307

HA SERIES. CVap Holding Cabinet Owner s Manual

GS-1. Instruction Manual. G-Series Cooler. Manual is for the following models: GS-1-N14NF GS-1-N14NG GS-1-N14NI COUNTERTOP COOLER

1.7 CU.FT. REFRIGERATOR INSTRUCTION MANUAL MCBR170BMD

INSTRUCTION MANUAL (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Owner's Manual TABLE OF CONTENTS

user s information manual

Porkka Inventus. Ultra Energy Efficient Commercial Refrigerators and Freezers. HOTEL, RESTAURANT & CATERING Commercial Upright Cabinets

Installation & Operations Manual Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800)

KITCHEN REFRIGERATION

FX Series FCSI. replace all your refrigeration needs with the most energy-efficient, flexible, food-safe system...ever!

Compact Refrigerator Refrigerador compacto Réfrigérateur compact

2.4 Cu. Ft. Compact Refrigerator

BLOOD PLASMA Walk-in Freezers

Contents Safety Warnings... 4 Unpacking... 6 Installation... 7 Product Overview Operation Cleaning Maintenance...

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

RCM-77. Instruction Manual. G-Series Cooler. Manual is for the following model: RCM-77-N23EB. U.S. Patent No. 8,215,125 RECHARGEABLE COLD MERCHANDISER

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

ULTRA LOW TEMPERATURE FREEZER. User Manual

Refrigerators. Technical Manual and Replacement Parts List FORM NO REV H MODEL SKTTR7FW MODEL SKC1220W

Instruction Manual. Bottle Cooler. Models HBC-50 (-S) HBC-65 (-S) HBC-80 (-S) HBC-95 (-S) hoshizakiamerica.com. Issued: Revised:

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Service Manual. Commercial Series Refrigerated Kitchen Equipment Models Undercounter Worktop Prep Table. hoshizakiamerica.com

SERIES NAV S Display Merchandisers

RPI Industries, Inc.

SERIES NIM. Low Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT

NOVA Products. Quality Refrigeration Since Reach-in, Roll-in & Pass-Thru Cabinets. Heated Cabinets. Blast Chillers. Blast Chillers/ Freezers

ICE CREAM DISPLAY MANUAL OF INSTRUCTIONS FOR USE AND INSTALLATION

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2

Instruction Manual. Refrigerator. Model: HS-65L

INSTALLATION AND OPERATION MANUAL

TCW 2000 Ice liner refrigerator and freezer PIJ

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS REFRIGERATORS OPERATING INSTRUCTIONS

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

User manual PRO range display chillers and display freezers

SAFETY QUALITY SUSTAINABILITY

Transcription:

START-UP TRAINING AND INSTRUCTIONS HURRICHILL BLAST CHILLERS AMERICAN PANEL CORPORATION, 5800 S.E. 78 TH Street, Ocala, Florida 34472, Tel. (800) 327-3015, Fax. (352) 245-0726

INDEX 1. CHECK FOR PROPER INSTALLATION...1 2. SPECIFICATIONS AND PERFORMANCE...3 2.1 Specifications...3 2.2 Performance...4 3. DESCRIPTION OF CYCLES AND OPERATION MODES...4 3.1 Automatic Mode...4 3.2 Manual Mode...4 3.3 Soft Cycle...4 3.4 Hard Cycle...4 3.5 Shock Freeze Cycle...5 3.6 Defrost Cycle...5 3.7 Thaw Cycle (if so equipped)...5 3.8 UV Cycle (if so equipped)...5 3.9 Heated Probe (shock freezer models only)...6 4. CONTROLLER OPERATION...7 4.1 Turn the Unit On....7 4.2 Engage the Soft Cycle in Automatic Mode...7 4.3 Engage the Hard Cycle in Automatic Mode...7 4.4 Engage the Shock Freeze Cycle in Automatic Mode (shock freezer models only)...7 4.5 Engage the Soft Cycle in Manual Mode...7 4.6 Engage the Hard Cycle in Manual Mode...8 4.7 Engage the Shock Freeze Cycle in Manual Mode (shock freezer models only)...8 4.8 Engage the UV Light Cycle (if so equipped)...8 4.9 Engage the Defrost Cycle (air type defrost models only, see 3.6)...8 4.10 Engage the Defrost Cycle (electric heater type defrost)...8 4.11 Engage the Heated Probe (if so equipped)...8 4.12 Print the HACCP Data (if so equipped)...9 4.13 Engage the Thaw Cycle in Automatic Mode (if so equipped)...9 4.14 Engage the Thaw Cycle in Manual Mode (if so equipped)...9 5. CUSTOMIZING THE CYCLES...9 6. PANNING, LOADING AND PROBING...10 6.1 Panning and Loading...10 6.2 Probing (for chilling / freezing cycles)...10 6.3 Probing (for thaw cycle)...10 7. MAINTENANCE...10 7.1 Daily Maintenance...10 7.2 Quarterly Maintenance...11 7.3 Annual Maintenance...11 8. START-UP COMPLETION FORM...11 Rev. A

1. CHECK FOR PROPER INSTALLATION Perform the checks below to ensure optimal operating conditions and to maximize the service life of the equipment. Check the integrity of the unit. Check for proper location. Ambient temperature no greater than 90 o F (to ensure rated performance) Must not be installed near heat source Must not be installed near grease source Must not be installed near vapor source Must not be installed in direct sun light Must not be installed in closed areas with insufficient air change Check for proper clearances (reach-in models) 1 clearance on the door handle side of the unit 2 ½ clearance on the door hinge side of the unit 3 clearance on the back of the unit Provide enough space in front to allow door opening Check for unobstructed air flow at the condensing unit Check for proper clearances (roll-in models) 6 clearance on the door handle side of the unit 6 clearance on the door hinge side of the unit 6 clearance on the back of the unit 15 clearance above the unit for service Provide enough space in front to allow door opening Check for unobstructed air flow at the condensing unit (self-contained models) Check to ensure the unit is level. Rev. A 1 of 12

Ask the customer to confirm that the electrical service is in accordance with the manufacturer nameplate located on unit, see figures below for nameplate locations. Ask the customer to confirm that the installation of the refrigeration lines was done in accordance with the installation instructions provided by the condensing unit manufacturer (remote refrigeration models only). Check the installation of the drain pan (reach-in units only) and check for proper drainage (reachin and roll-in models). Check the integrity of the wire shelves (if so equipped). Operate the unit in Hard Chill / Manual Mode for a few minutes to verify temperature pull down. Verify proper airflow direction. Evaporator front to back Condenser front to back Note: American Panel Corporation blast chillers are equipped with a short cycle protection. If the unit is stopped or the door is opened and closed during a chilling cycle more than once, the compressor will not start for 3 to 5 minutes. Engage, operate and verify effectiveness of manual defrost cycle. Verify UV light (if so equipped) is functional. Verify printer (if so equipped) functions with adequate paper and ribbon. Verify PC connection (if so equipped) is functional. Inform the factory if any functional and performance issues were found following the completion of the above tests (see Hurrichill Start-Up Completion Form at the end of these instructions). Rev. A 2 of 12

2. SPECIFICATIONS AND PERFORMANCE 2.1 Specifications Familiarize the customer with the specifications of his particular unit, see the chart below. MODEL NUMBER TYPE NUMBER OF PANS PAN SIZE MOBILE RACK MAXIMUM SIZE (W X D X H) CHILLING CAPACITY [LBS] FREEZING CAPACITY [LBS] AP3BC30-1 BLAST CHILLER 3 12"X20"X2.5" N/A 30 N/A AP3BCF30-1 AP5BCF45-2 AP7BCF70-2-C AP7BCF70-2 AP10BCF100-2 AP12BCF110-3 AP20BCF200-3 3 12"X20"X2.5" N/A 30 18 5 12"X20"X2.5" N/A 45 27 7 \ 7 14 \ 7 N/A 70 42 N/A 70 / 100* 10 12"X20"X2.5" N/A 100 60 24 \ 12 20 \ 10 AP20BC200-2 BLAST CHILLER 20 \ 10 AP20BCF200-2 20 \ 10 AP24BC250-3 BLAST CHILLER 24 \ 12 AP24BC250-3-R AP24BCF300-3 AP24BCF300-3-R BLAST CHILLER (1) 202 RATIONAL RACK 24 \ 12 (1) 202 RATIONAL RACK AP40BC350-3 BLAST CHILLER 40 \ 20 AP40BCF450-3 40 \ 20 AP80BC700-3 BLAST CHILLER 80 \ 40 AP80BCF900-3 80 \ 40 AP120BC1000-3 BLAST CHILLER 120 \ 60 AP120BCF1300-3 120 \ 60 AP40BC250-12 BLAST CHILLER 40 \ 20 AP40BC250-2-12 BLAST CHILLER 80 \ 40 BCIP BLAST CHILLER 80 \ 40 BCCP-1 BLAST CHILLER 40 \ 20 BCCP-2 BLAST CHILLER 80 \ 40 12"X20"X2.5" 12"X20"X2.5" N/A 110 / 160* 60 90 26 x31 x72 200 120 26 x31 x72 200 N/A 26 x31 x72 200 120 29 x35 x72 250 N/A (1) 202 RATIONAL RACK 250 N/A 29 x35 x72 300 180 (1) 202 RATIONAL RACK 300 180 29 x39 x72 350 N/A 29 x39 x72 450 270 2 EA 29 x39 x72 2 EA 29 x39 x72 3 EA 29 x39 x72 3 EA 29 x39 x72 700 N/A 900 540 1000 N/A 1300 780 34 x36 x76 250 N/A 2 EA 34 x36 x76 2 EA 34 x36 x76 34 x36 x76 (CHECK DOOR CLEARANCE) 2 EA 34 x36 x76 (CHECK DOOR CLEARANCE) *- the lower number will surpass the FDA requirements, the higher number will meet the FDA requirements. 500 N/A 500 N/A 250 N/A 500 N/A Rev. A 3 of 12

2.2 Performance Familiarize the customer with the rated performance and product capacity in Lbs. of the unit. Hurrichill blast chiller models are capable of lowering the core temperature of the product (see above chart for chilling capacity in Lbs.) from 160 o F to 38 o F within 90 minutes. Hurrichill shock freezers are capable of lowering the core temperature of the product (see above chart for freezing capacity in Lbs.) from 160 o F to 0 o F within 240 minutes. Note: Each Hurrichill model was designed for a specific product capacity in Lbs. Overloading the unit could significantly reduce the service life of the unit. 3. DESCRIPTION OF CYCLES AND OPERATION MODES 3.1 Automatic Mode In Automatic Mode, the blast chiller will read the food temperature via the food probe and adjust the air temperature accordingly. Note: When using Automatic Mode it is very important to insert the food probe in the product. The food probe must read the core temperature of the product in order for the unit to work as intended. 3.2 Manual Mode In Manual Mode, the air will be held at a preset temperature for a preset amount of time according to the selected operating cycle (see the explanation for the cycles below). 3.3 Soft Cycle Use for delicate items such as vegetables, deli items and salad items. Also, use for low fat and low moisture content products such as bakery goods. Soft Cycle Auto Mode, Factory Presets The air temperature will cycle between 28 o F and 35 o F until the food core temperature will reach 40 o F, at this point the blast chiller will switch into holding mode where the air temperature will cycle between 35 o F and 42 o F until the food is removed from the cabinet and/or cycle is stopped by the operator. Soft Cycle Manual Mode, Factory Presets The air temperature will cycle between 28 o F and 35 o F for 1.5 hours. After 1.5 hours the unit will switch into holding mode where the air temperature will cycle between 35 o F and 42 o F until the food is removed from the cabinet and/or cycle is stopped by the operator. 3.4 Hard Cycle Use for all foods. Some freezing on the food surface may occur, especially with thicker products; if this is not acceptable use Soft Cycle (see 3.3) Hard Cycle Auto Mode, Factory Presets The air temperature will cycle between 0 o F and 10 o F until the food core temperature will reach 60 o F (first part of the cycle). After the food core temperature reaches 60 o F the air temperature inside the unit will cycle between 28 o F and 35 o F (second part of the cycle) until the food core temperature will reach 40 o F. At this point the blast chiller will switch into holding mode where the air temperature will cycle between 35 o F and 42 o F until the food is removed from the cabinet and/or cycle is stopped by the operator. Hard Cycle Manual Mode, Factory Presets The air temperature will cycle between 0 o F and 10 o F for one hour (first part of the cycle). After one hour the air temperature inside the unit will cycle between 28 o F and 35 o F for another hour (second part of the cycle). At this point the blast chiller will switch into holding mode where the air temperature will cycle between 35 o F and 42 o F until the food is removed from the cabinet and/or cycle is stopped by the operator. Rev. A 4 of 12

3.5 Shock Freeze Cycle Use for all freezing needs. When using the Hurrichill Shock Freezing Cycle the ice crystals that form within the product are very small, the quality and the texture of the product is preserved. For that reason, the Shock Freeze Cycle is suitable even for delicate products such as sushi meat and prime meat cuts. Shock Freeze Cycle will give excellent results when used in the process of Ice Cream and Gelato hardening, it will give a smooth texture to the product. Shock Freeze Cycle Auto Mode, Factory Presets The air temperature will cycle between -25 o F and -15 o F until the food core temperature will reach 0 o F, at this point the blast chiller will switch into holding mode where the air temperature will cycle between -4 o F and 3 o F until the food is removed from the cabinet and/or cycle is stopped by the operator. Shock Freeze Cycle Manual Mode, Factory Presets The air temperature will cycle between -25 o F and -15 o F for 4 hours. After 4 hours the unit will switch into holding mode where the air temperature will cycle between -4 o F and 3 o F until the food is removed from the cabinet and/or cycle is stopped by the operator. Important! At the end of each blast chilling cycle the unit will switch into holding mode to maintain the food at a specific temperature; however, the blast chiller was not designed to be a refrigerator/holding cabinet. Do not allow the blast chiller to function in holding mode for extended periods of time. Occasional overnight holding is allowed. 3.6 Defrost Cycle Use to defrost the evaporator coil. The defrost cycle must be manually engaged (see controller operation below). Defrost the unit once a day or as needed. Ice build-up can be observed as looking thru the fan grill at the evaporator coil. The factory preset for Defrost Cycle is 15 minutes on models with air type defrost (most models). AP40BC250(-2)-12, BCCP-1, BCCP-2, and BCIP models have electric heater defrost and the factory preset for the Defrost Cycle on these models is 30 minutes. 3.7 Thaw Cycle (if so equipped) Use to thaw frozen products. Units equipped with the Thaw feature will be delivered with a special thaw probe, a cordless drill and a sanitary drill bit. Use the cordless drill and sanitary drill bit to probe the frozen product. Thaw Cycle Automatic Mode, Factory Presets The air temperature will cycle between 42 o F and 50 o F until the food temperature, as recorded by the thaw probe, will reach 32 o F; at this point the blast chiller will switch into holding mode where the air temperature will cycle between 35 o F and 42 o F until the food is removed from the cabinet and/or cycle is stopped by the operator. Thaw Cycle Manual Mode, Factory Presets The air temperature will cycle between 42 o F and 50 o F for a preset amount of time, set by the operator at the time of starting the cycle. After the cycle time expires, the unit will switch into holding mode where the air temperature will cycle between 35 o F and 42 o F until the food is removed from the cabinet and/or cycle is stopped by the operator. Note: When probing for thaw cycle, use the drill bit to provide a hole in the frozen product. Make sure the thaw probe is fully inserted into the product but not more than 1 from the surface. 3.8 UV Cycle (if so equipped) The UV light (germicidal light) inhibits the bacterial formation and multiplication. Use the UV Cycle to sterilize the cabinet after the daily cleaning. UV light must not be used as a substitute for cleaning. The factory preset time for the UV light is 30 minutes. Rev. A 5 of 12

3.9 Heated Probe (shock freezer models only) Use the Heated Probe feature prior to extracting the temperature probe from the frozen product. Gentle heat will be applied to the food probe for 5 seconds to facilitate the extraction of the probe. The Heated Probe will run only if the temperature at the food probe is below 30 o F. Repeat the heated probe cycle if needed. FACTORY PRESETS AUTOMATIC MODE QUICK REFERENCE CHART SETTING CYCLE LOW AIR PART 1 HIGH AIR PART 1 BREAKING TEMP. LOW AIR PART 2 HIGH AIR PART 2 END FOOD TEMP. LOW AIR HOLDING HIGH AIR HOLDING SOFT 28 o F 35 o F NA NA NA 40 o F 35 o F 42 o F HARD (CHILLERS ONLY) 10 o F 20 o F 60 o F 28 o F 35 o F 40 o F 35 o F 42 o F HARD (CHILLERS / FREEZERS) 0 o F 10 o F 60 o F 28 o F 35 o F 40 o F 35 o F 42 o F SHOCK FREEZE -25 o F -15 o F NA NA NA 0 o F -4 o F 3 o F THAW 42 o F 50 o F NA NA NA 32 o F 35 o F 42 o F SETTING CYCLE FACTORY PRESETS MANUAL MODE QUICK REFERENCE CHART LOW AIR PART 1 HIGH AIR PART 1 TIME PART 1 LOW AIR PART 2 HIGH AIR PART 2 TIME PART 2 LOW AIR HOLDING HIGH AIR HOLDING SOFT 28 o F 35 o F NA NA NA 90 MIN 35 o F 42 o F HARD (CHILLERS ONLY) 10 o F 20 o F 60 MIN 28 o F 35 o F 60 MIN 35 o F 42 o F HARD (CHILLERS / FREEZERS) 0 o F 10 o F 60 MIN 28 o F 35 o F 60 MIN 35 o F 42 o F SHOCK FREEZE -25 o F -15 o F NA NA NA 240 MIN -4 o F 3 o F THAW 42 o F 50 o F NA NA NA SET AT START 35 o F 42 o F Rev. A 6 of 12

4. CONTROLLER OPERATION 4.1 Turn the Unit On. From off mode (display is reading OFF ) press operator to choose an operating cycle.. The unit is on and the display is prompting the 4.2 Engage the Soft Cycle in Automatic Mode press to choose the Soft Cycle, the display will prompt the operator to choose the operating mode. press to choose the Automatic Mode, the display will prompt the operator to press start. press to start the cycle. 4.3 Engage the Hard Cycle in Automatic Mode press to choose the Hard Cycle, the display will prompt the operator to choose the operating mode. press to choose the Automatic Mode, the display will prompt the operator to press start. press to start the cycle. 4.4 Engage the Shock Freeze Cycle in Automatic Mode (shock freezer models only) press to choose the Shock Freeze Cycle, the display will prompt the operator to choose the operating mode. press to choose the Automatic Mode, the display will prompt the operator to press start. press to start the cycle. 4.5 Engage the Soft Cycle in Manual Mode press to choose the Soft Cycle, the display will prompt the operator to choose the operating mode. press to choose the Manual Mode, the display will prompt the operator to press start. Rev. A 7 of 12

press to start the cycle. 4.6 Engage the Hard Cycle in Manual Mode press to choose the Hard Cycle, the display will prompt the operator to choose the operating mode. press to choose the Manual Mode, the display will prompt the operator to press start. press to start the cycle. 4.7 Engage the Shock Freeze Cycle in Manual Mode (shock freezer models only) press to choose the Shock Freeze Cycle, the display will prompt the operator to choose the operating mode. press to choose the Manual Mode, the display will prompt the operator to press start. press to start the cycle. 4.8 Engage the UV Light Cycle (if so equipped) press to choose the UV Light Cycle, the display will read READY TO START. press to start the cycle. 4.9 Engage the Defrost Cycle (air type defrost models only, see 3.6) Press to choose the Defrost Cycle, the display will read OPEN DOOR!. Open the door and press to start the cycle. 4.10 Engage the Defrost Cycle (electric heater type defrost) Press to choose the Defrost Cycle. Press to start the cycle. 4.11 Engage the Heated Probe (if so equipped) Press to heat the food probe Rev. A 8 of 12

Carefully extract the food probe from the frozen product. 4.12 Print the HACCP Data (if so equipped) From the OFF mode: Press to print the HACCP data. The display will read the remaining storage capacity in number of events. Examples: The display reads READINGS LEFT 120-120 additional events could be recorded on the internal memory. The display reads READINGS LEFT recordings will overwrite the old ones. 0 there is no available internal memory; the new Press to print the events. 4.13 Engage the Thaw Cycle in Automatic Mode (if so equipped) Press to choose the Thaw Cycle. press to choose the Automatic Mode, the display will prompt the operator to press start. Press to start the cycle. 4.14 Engage the Thaw Cycle in Manual Mode (if so equipped) Press to choose the Thaw Cycle. Press to choose the Manual Mode, the display will prompt the operator to set the cycle time. Scroll up or down to set the desired cycle time. Press to start the cycle. 5. CUSTOMIZING THE CYCLES Hurrichill blast chilling / shock freezing cycles have been designed to deliver optimum chilling / freezing performance for most food products. If need be, all the cycles can be customized. Consult the User s Manual and contact American Panel Corporation before attempting to customize any cycle. Note: Serious damages could occur to the unit due to faulty settings. Rev. A 9 of 12

6. PANNING, LOADING AND PROBING 6.1 Panning and Loading Follow the methods below for faster cooling, freezing and thawing: Place the food in shallow pans. Do not use food pans deeper than 2 ½ and do not fill the pan with more than 2 of product. Separate the food in smaller or thinner portions. Do not cover the containers unless danger of overhead contamination. Loosely cover the containers if necessary. Allow the cover material (aluminum foil ) to touch the surface of the food. Arrange the pans for optimum air circulation within the cabinet. Know the capacity of the unit. Do not overload the unit. 6.2 Probing (for chilling / freezing cycles) Follow the methods below to ensure correct probing of the product: Insert the food probe into the thickest part of the product. The tip of the food probe will have to be located at the core of the food. Always place the available food probe in the hardest to cool product. It is a good practice to restart the cycle every time food is added. Clean and sanitize the food probe after each use. 6.3 Probing (for thaw cycle) Follow the methods below to ensure correct probing of the product: Use the provided drill and drill bit to drill a hole into the frozen product. Fully insert the thaw probe into the frozen product. Do not insert the thaw probe more than 1 from the surface of the product. 7. MAINTENANCE 7.1 Daily Maintenance Defrost the unit daily or as needed (see instructions 3.6, 4.9 and 4.10). Wipe clean the interior and the exterior of the unit using a solution of mild soap and water. Wipe clean the door gasket. Engage the UV light cycle. Empty and clean the drain pan. Completely dry the cabinet every night. Leave the door slightly open overnight or when not in use. Important! Do not use any corrosive chemicals to clean the unit! Do not use any abrasive materials to clean the unit! Do not spray water on the unit! Rev. A 10 of 12

7.2 Quarterly Maintenance The quarterly maintenance should be done by a service technician or by trained maintenance personnel. Inspect door hinge for proper operation. Inspect door gasket for proper seal. Inspect the drain line for proper flow. Use vacuum and brush to clean the condenser coil. Clean the evaporator coil. Important! Do not use water jet to clean the condenser coil! Do not use any sharp or abrasive materials to clean the coils! When cleaning the evaporator use only the cleaning agent listed below and follow the directions on the container for proper mixing and cleaning. Cleaning Agent Vendor Part Number Enviro-Coil Concentrate Enviro-Coil Concentrate Home Depot Supply http://hdsupplysolutions.com Hydro-Balance Corporation Tel. 972 394-9422 H-ECO1 H-ECO1 7.3 Annual Maintenance A comprehensive annual maintenance schedule is highly recommended. A Preventive Maintenance Checklist is provided with the unit; follow the instructions in the list. 8. START-UP COMPLETION FORM Fill the Start-Up Completion Form attached to these instructions and Fax or Mail to American Panel Corporation. Rev. A 11 of 12

AMERICAN PANEL CORPORATION 5800 S.E. 78 TH Street Ocala, Florida 34472 Tel. (800) 327-3015 Fax. (352) 245-0726 HURRICHILL START-UP COMPLETION FORM START-UP DATE: START-UP LOCATION: HURRICHILL MODEL: HURRICHILL SERIAL NUMBER: HURRICHILL REPRESENTATIVE: CUSTOMER REPRESENTATIVE: FACILITY TYPE: RESTAURANT SCHOOL KITCHEN HOSPITAL KITCHEN FOOD PROCESSING FACILITY RETAIL - DELI KITCHEN CATERING CASINO CONVENTION CENTER MILITARY CANTINA CORRECTIONAL CANTINA OTHER MARK BELOW THE DISCUSSED TOPICS: CHECK FOR PROPER INSTALLATION SPECIFICATIONS AND PERFORMANCE DESCRIPTION OF CYCLES AND OPERATION MODES CONTROLLER OPERATION CUSTOMIZING THE CYCLES PANNING, LOADING AND PROBING MAINTENANCE COMMENTS: