EXPRESS BOOM ASSEMBLY

Similar documents
1. CONDITIONS FOR USE 2. SAFETY

Wogaard Coolant Saver TM

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

A Green Solutions Company

Sprayer Equipment. Sprayer Equipment. Sprayers SUPERSPRAYER LT SERIES / XLT SERIES. Spray Fill Xpress

Daikin Water Cooling, Heating, and High Capacity Booster Coils

CHEMICAL MIXER. watch video

INSTALLATION INSTRUCTIONS

Progress in the Devlopment of an In-Canopy Fixed Spraying System for High-Density Apple Orchards

DECONTAMINATING AND WINTERIZING AIRBLAST SPRAYERS

Scale Stopper Plus Installation & Start-Up Guide

Installation, Operation and Maintenance Manual. Model: SSC ScaleSolver Systems. Chemical Free, Salt Free, Scale Prevention

Assembly, Installation & Watering Guide VERTICAL GARDEN SYSTEM. Version 4. Product Version. Gro-Wall 4.0.

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Parts and Equipment Washing, Rinsing and Drying Using Spray Technology

POWERFUL CUSTOMIZED SOLUTIONS UNMATCHED QUALITY

REDUCING THE COST OF WEED MANAGEMENT FOR CONTAINER GROWN ORNAMENTALS SALI BAROLLI PLANT HEALTH MANAGER IMPERIAL NURSERIES, INC.

SPRINKLER SYSTEMS DESIGN GUIDE AUTOMATED WATERING SYSTEMS FOR GREENHOUSE AND NURSERY

Sprinkler Systems Design Guide

Welcome! Today s topic: Small Home Repairs. November 14, 2015

J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide

J-PRO-24 Pump Chlorinator. Installation & Start-Up Guide

Application Instructions

A GUIDE TO FOOD SAFETY & SANITATION USING SPRAY TECHNOLOGY SOLUTIONS FOR MEAT & POULTRY, BAKERY, CHEESE, TANK CLEANING & MORE

Solutions at every turn.

AIC Brazed Plate Heat Exchanger Operating and Instruction Manual

Installation Instructions AS-WH Whole House Water Filter

Weeds in Ornamental Plantings:

SENSEI Series Features

Basic Repairs and Maintenance for Home Landscape Irrigation Systems 1

The Intelligent Use of Water: Water Efficient System Overview

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Sprayer Tank Clean Out: Issues in the Field (Avoiding that Once in A Lifetime Learning Opportunity)

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

Carrefour. Fresh in-store communication at Carrefour Belgium QUICK FACTS:

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

Fertilizing Systems. Fertilize Responsibly INSTALLATION AND OPERATING GUIDE

Sprayers. Sprayers. Sprayers LT SUPERSPRAYER / XLT SUPERSPRAYER

Install Configurations

BASCO TYPE ES EXTENDED SURFACE PLATE FIN HEAT EXCHANGERS. ...world leaders in heat transfer technology

Steele Extrusion Machinery

J-PRO V 230V Dual Voltage Chlorinator Installation & Start-Up Guide

Survey Says: Clean for Safety and Profitability

SOLAR HOT WATER HEATERS

Operating Room Diffuser System with Integrated LED Lighting

Installation, Operation, and Maintenance Manual

Distributed By: M&M Control Service, Inc Building Technologies

SENJU SPRINKLER CO., LTD.

SAFETY INFORMATION GO TO VAPAMORE.COM TO SEE THE MR-75 AMICO INSTRUCTIONAL VIDEO

PolyMax H2-24 Dutch Bucket System

Index. + Kleen Kote 200 Concentrate. + Kleen Krete. + Real Pump Power Spraying System. + Real Pump EXPRESS Portable Power Spraying System

Ariel PlAtinum AnnA tb222m installation guide

E njoy... Quality Solar Heaters

Brazed Plate Heat Exchanger Operations Manual

L24TWS. Beverage Tower Kit Components. L24TWD Lynx Beverage Kits Model L24TWS Single Tower and L24TWD Double Tower

PIONEERS IN AIR VACUUMS

Fleck 2510 SXT Catalox Installation & Start Up Guide

REDUCING THE COST OF WEED MANAGEMENT IN CONTAINER NURSERY PRODUCTION SALI BAROLLI PLANT HEALTH MANAGER IMPERIAL NURSERIES, INC.

J-PRO-24 Soda Ash Injection Installation & Start-Up Guide

plumbing for greywater

The 7 attributes of highly effective quick disconnect couplings for liquid cooling of computers and servers

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

Qualification Procedures for making PE 3408 Extra High Molecular Weight Polyethylene Heat Fusion Joints

J-PRO V 230V Dual Voltage Hydrogen Peroxide Pump Installation & Start-Up Guide

...WHY WAIT? IT S TIME TO SWITCH TO A NORITZ TANKLESS

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

ORCHARD SPRAYERS. silvan.com.au. The Spraying Specialists

FIRE SUPPRESSION SPRINKLER SYSTEM

Flow-Rite Original Ink Dispensing Cartridge

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Clean Water Made Easy

Data Sheet 4.16 Issue D

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

Rotary Screw Vacuum Systems

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

providing the perfect mix

INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE

UL/FM Fire Protection Products Setting the Standard

FLUID COIL INSTALLATION OPERATION AND MAINTENANCE

Heat Exchanger Block Replacement Instructions

Installation Instructions EQ-AST-WH & EQ-AST-WH-C. Whole House Water Filter

TANKER & STORAGE TANK PRODUCTS

CWS Plus Sediment Filter Installation & Start Up Guide

PARTS OVERVIEW GO TO VAPAMORE.COM TO SEE THE MR-75 AMICO INSTRUCTIONAL VIDEO

Commercial Flat Concealed Sprinkler, Pendent, Quick Response, Extended Coverage (Light Hazard) Model: RC-QR-EC, K-Factor: 5.

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager

COMMERCIAL POOL HEATING SYSTEMS AND COVERS:

The Sterling Series. Pressing Excellence. Pre Pressing Full Pressing Rendering

CLOSE SPACING LEPA BUBBLERS

INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE

Industrial Heaters for Packaging Applications

INSTALLATION INSTRUCTIONS

Alkaline RO System INSTALLATION MANUAL

Threaded. Flanged. Model PSH. Primary Secondary Header A-451

Farm Food Safety: Building an Easy Clean Produce Wash Table

Transcription:

EXPRESS BOOM ASSEMBLY POCKETBOOK 06 HYPRO ACCESSORIES W W W.H Y PROSPR AY TIP S.COM

Why Express Boom Assembly? UPDATE OLD STYLE POLY BOOM TO ENHANCED STAINLESS BOOM Eliminate warping with a stainless steel pipe: Many of today s sprayers are equipped with Black Poly Pipe on the spray booms. Exposure to long periods of summer sun and chemicals can cause damage. Over time, soft poly pipes will sag and allow pooling inside of the boom pipe. Low spots in the boom pipe can inhibit efficient flow through the boom pipe and make a boom harder to flush. The Express Boom Assembly features a Schedule Stainless Steel pipe that eliminates the ability to warp. New nozzle bodies and express fittings: The refreshed boom plumbing includes all new nozzle bodies and Express Fittings. The Express fittings and the optimized design allow for improved sprayer performance. Improve shutoff times with Express End Caps and eliminate chemical contamination: Upgrading to Stainless Steel Express Booms will dramatically improve nozzle shut-off times by eliminating trapped air. With the Express End Caps on each end of the boom, the shut off delay can be reduced up to 0- seconds. EASY-TO-USE CONFIGURATOR Express Boom Configurator is an Easy-to-Use Tool that will step you through the process of selecting the right layout for each boom pipe section on your sprayer. (Technical Assistance is available a -800--860) CONVERTING FROM A DRY BOOM SPRAYER Many of the older Trailer Sprayers in the field have the DRY BOOM set-ups. Upgrading to the Express Booms converts the sprayer to a WET BOOM set-up. This will improve sprayer performance as it includes Express End Caps for air elimination and boom pipe flush. LOW COST OPTION TO UPDATE YOUR SPRAYER The Express Boom Assembly simplifies the manufacturing process and supply chain by reducing labor, assembly time and product numbers.it eliminates the need to stock component parts such as pipes, fittings, or nozzle bodies, by providing package options that make it convenient for standard shipping methods. (i.e FedEx, UPS, etc.) The Pre-Assembled Boom Pipe sections are Factory Pressure Tested. They can be mounted on boom sections with confidence and go to the field ready to spray. Page

Old Style Poly Boom vs. Express Boom Express Boom 6 Poly Boom (Old Style) POLY BOOM - OLD STYLE Warping of the boom causes inefficient and ineffective spray applications. Chemistry, sunlight, and hot summer temperatures will cause the black poly pipe to swell, sag and distort. The spray nozzles attached to the pipe are distorted or Torqued out of specification. Air can also be trapped in the low spots. (Similar to a plumbers P-Trap). This can cause slow shut-off times and delayed start up times when spraying. (Item ) Leak points from threaded fittings. Warped poly pipes can increase the chance of leaks at threaded connections. The Express Booms are equipped with the NEW Flanged Fittings that provide leak-proof connections. (Item ) Torqued nozzle bodies give off-target applications. As the poly pipe distorts and twists, the torqued nozzle bodies can shift and direct away from the specific target. The result of this is improper spray coverage and overlap. (Item ) EXPRESS BOOM - INNOVATIVE SOLUTION The Express Boom features Express End Caps to provide adequate boom hygiene and allow for easy boom cleanout. (Item ) (See also page ) Durable grade with Schedule Lightweight Stainless Steel pipe complete with Express Fittings, UF Clamp, and Gaskets. These upgrades provide a higher pressure rating, do not allow chemical absorption and will not sag over time. (Item 6) -way ProFlo nozzle bodies with polymer EPDM 8PSI Diaphragm Check Valve. Express Booms are ready for the NEW ProStop-E Individual Nozzle Shut-Offs. Consult Hypro Technical Services at 800--860 for more information. or 0 spacing configurations are available for your specific spraying needs. Many new spray techniques are being adopted and changes to the boom spacing is key to these new spray techniques. Dead End spaces allow chemical residue to build up at the ends of the boom pipe. Poly pipes absorb spray chemistry that make it difficult to completely clean out, which increases the chance of cross contamination when changing chemicals. (Item ) Page

Express End Cap - Improved Shut-off Time ISSUE WITH CONVENTIONAL BOOMS Trapped air in the boom will cause shut off lag. Every time you empty the spray tank, change products or flush the system, then refill the sprayer, air gets trapped in the boom lines. This trapped air causes a delayed response in nozzle shut off (up to seconds in some cases). Shut-off lag can cause overspray on unintended areas such as: grassy waterways, overlaps, end rows and boundary areas. The operator must allow for shut off lag time when turning on field ends or crossing grass waterways. SOLUTION - EXPRESS END CAP Passive feature eliminates the trapped air by allowing the air to escape through the nozzle body. Trapped air rises to the top of the boom pipes. Express End Cap vents the air out through the nozzle body when the boom is pressurized. Page

Express End Cap - Boom Hygiene and Removal of Dead Ends In traditional booms, there is a section of pipe at the end of the boom, Dead End Zones (Fig.), that allow chemical contaminate to build up (Fig. ). Express Booms with Express End Caps removes these Dead End Zones by putting the last nozzle body at the end of the pipe. A removable plug (Fig. ) is also placed at the end to allow better flow and flushing through the nozzle bodies, and eliminates the risk of chemical build up in the boom pipe. In result of this, when you go from one type of herbicide to another, there will be a lower risk of field streaking due to chemical contamination (Fig. ). CHEMICAL CONTAMINANT IN DEAD END BOOM PIPE CHEMICAL CONTAMINATION REMOVE PLUG FIELD STREAKING Page

Easy-to-Use Express Boom Configurator Opportunity With Express Booms, you can specify nozzle spacing to take advantage of new spray techniques. Over the years, 0 spacing has been very common on sprayers. Changing to spacing enables more spray pattern overlap which increases coverage. It also enables spraying over and between 0 rows when using drops. Solution: Whether its or 0 spacing, the express boom assembly can meet the needs of the grower. You can create varied configurations with the Hypro Express Boom Configurator. Spray Booms are laid out by the manufacturers to optimize folding and storage. The Boom Configuration Tool allows you to re-create the exact layout of your old boom to the NEW Express Boom System. Choose Left Branch Tee Choose Right Branch 6* 6* There are many boom plumbing configurations because of boom structure length fold and breakaway points, etc. Below is an example of a X configuration. This configuration has nozzle bodies to the left of the inlet tee and to the right. EXPRESS BOOM CONFIGURATOR TOOL The Express Boom Configurator helps you find the correct part numbers for ordering. To use the configurator tool, you will simply enter the plumbing configuration and it will select boom pipe part numbers for you to order. The tool will also designate boom pipe position on your spray boom. www.hypropumps.com/express Page 6

Frequently Asked Questions What is the pricing for the Express Boom Assembly? - Please see the price sheet for pricing of standard boom configuration. Tailored configurations will be priced separately. How does this product provide value? - It reduces labor and simplifies the manufacturing process. It allows OEM s to focus on machine assembly, and minimizes the assembly for the customer. What are the standard replacement parts for the boom assembly? - Express End Cap, Express Tee, ProFlo Nozzle Body Series. Do the boom assembly sections fit into existing boom structures on the sprayer? The boom assembly concept was designed to be a modular product. Boom sections can -vary in length and configuration to meet any existing boom structure. It is common that replacement of aged boom plumbing will be required and the ability to purchase tested and pre-fabricated boom sections will eliminate many concerns. Standard products will be available for tailored configurations and off-the-shelf applications. Spec products will be tailored to meet a specific boom design; part numbers and prints will be generated for these configurations and provided to the customer. Common Terms On-Center: Boom space alignment starting with the nozzle body at the center of the sprayer. Generally with Spacing. Off-Center: Boom space alignment starting with nozzle bodies that are equally offset from the center of the sprayer. Generally with 0 Spacing. Over the Row: Current practice is to plant 0 rows, therefore spacing aligns spray patterns on and in between each row. This is why growers use Express Boom to change from 0 to spacing. Between the Row: Spraying between crop rows. Also refers to nozzle position on the boom to spray between rows. Schedule tubing: Thin walled tubing or boom pipe. Lighter weight and allows slightly more flow. (The New Standard in Wet Boom Sprayer Applications) Used with Hypro Express Boom Assembly. Boom Hygiene: This is Hypro s slogan (not trademarked) used to promote cleanout, and mitigate crop injury. Images of clogged booms, and field stripping are well paired with Boom Hygiene. Page 7

Additional Resources WEBSITE VIDEOS-YOUTUBE CONFIGURATOR TOOLS Tee Choose Left Branch Choose Right Branch 6* 6* OIPM PRESS RELEASE BROCHURE FOR IMMEDIATE RELEASE PENTAIR LAUNCHES HYPRO EXPRESS BOOM ASSEMBLY BOOM-IN-A-BOX DESIGNED TO SAVE TIME, MONEY NEW BRIGHTON, MIN. February, 0 Pentair Ltd. (NYSE: PNR) announced today the launch of the Hypro Express Boom, a pre-assembled wet boom designed to eliminate complexity and minimize labor costs. Hypro s Express Boom Assembly saves hours of expensive labor for Distributors and OEMs by delivering a fully-assembled, performance-tested boom. The Hypro Express Boom Assembly consists of many components needed for a wet boom, and is pre-assembled in many standard configurations. The standard assembly is complete with stainless steel piping, -way ProFlo nozzle bodies and Express end-caps and fittings. Custom options are also available. BOOM-IN-A-BOX SAVES TIME, MONEY According to Gene Schellhorn, Pentair Product Manager, The Express Boom Assembly is as turn-key as it gets for wet booms. We ship a plumbed, performance-tested assembly that can be mounted in about an hour. It s essentially a boom-in-a-box, specified for a customer s precise needs. Schellhorn says the benefits to OEMs and Distributors are obvious, No drilling, no cutting, no threading. No custom tools or fixtures needed. No need to stock component parts such as pipes, fittings, or nozzle bodies. The Express Boom Assembly is a significant time and labor saver saving our customers valuable time and money. The Hypro Express Boom Assembly utilizes the award-winning Hypro Express Nozzle Body End Cap, which eliminates trapped air from the boom by allowing air to escape through the nozzle body. This reduces nozzle turn-off time by 8%, eliminates dead-ends from each pipe, and eliminates potential chemical contamination. The Express Boom also utilizes O-ring sealed joints for all wet boom fittings, eliminating the need for leakprone threaded joints and welded fittings. This also allows for lighter schedule stainless steel pipe in place of heavy schedule 0 pipe. In addition to the standard configurations offered, the Hypro Express Boom can be ordered from the factory with custom tips, piping, gaskets, nozzle bodies and spacing. More information on the Hypro Express Boom Assembly, including where to buy, can be found at www.hypropumps.com. About Pentair Ltd. Pentair (www.pentair.com) delivers industry-leading products, services and solutions for its customers diverse needs in water and other fluids, thermal management and equipment protection. With pro forma revenues of approximately $8 billion, Pentair employs more than 0,000 people worldwide. ### Pentair Media Contact: Tegan Moehn, Marketing Specialist Tel.: 6-766-677 E-mail: tegan.moehn@pentair.com SOURCE Pentair Ltd. 0 Pentair Ltd. All Rights Reserved. HSPR (0/0/) Printed in USA For more information visit: www.hyprospraytips.com/express www.youtube.com/hyprospraygroup 7 TH AVE NW, NEW BRIGHTON, MN WWW.HYPROSPRAYTIPS.COM PH: 800--9776 ORDERS FAX: 800--696 Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair Ltd. All Rights Reserved. FORM 06 (/) Printed in USA