MODELS D49M30SB, D49M36SB, D49M48SB DOWNDRAFT

Similar documents
CATTURA TM DOWNDRAFT MODELS D49M30SB, D49M36SB, D49M48SB

CAUTION signals a situation where minor injury or product damage may occur if you do not follow instructions.

READ AND SAVE THESE INSTRUCTIONS

VIPR Professional Downdraft w/remote

ducted / recirculating separately 2.1 WS / 11.8 HS 3-stage Rear Yes (600 CFM options sold separately) 29 3/8" x 31" x 2 3/4" 6" or 8"

Downdraft Ventilation

UCVM36RS 36-INCH DOWNDRAFT VENTILATION MASTERPIECE SERIES. GENERAL PROPERTIES Operating Mode Convertible: Ducted / Recirculating

USE / INSTALLATION GUIDE

ERV3015, ERV3615, ERV36-ER, ERV48, ERV48-ER, PRV30, PRV36, PRV48

Cooktop Chimney Ventilation Hoods

USE / INSTALLATION GUIDE

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

gas cooktops EW30GC55P S / B

VCI248DS 48-INCH CUSTOM INSERT MASTERPIECE SERIES

Installation Instructions

UCVM30FS 30-INCH DOWNDRAFT VENTILATION MASTERPIECE SERIES

UseandCare & Installation Guide

READ AND SAVE THESE INSTRUCTIONS

ERV3015, ERV3615. Renaissance 30, 36 Wide, High Extension Slim Raised Vents. Top cap with vent down

Installation Instructions

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

! INTENDED FOR DOMESTIC COOKING ONLY!

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

E60000 SERIES INTENDED FOR DOMESTIC COOKING ONLY

PH36HWS 24-INCH DEPTH WALL HOOD (36-INCH WIDTH) PROFESSIONAL SERIES

Featuring Bake & Brown Convection Product Dimensions. Bake & Microwave Option

PH48HWS 24-INCH DEPTH WALL HOOD (48-INCH WIDTH) PROFESSIONAL SERIES

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

HPCN48WS 48-INCH CHIMNEY WALL HOOD PROFESSIONAL SERIES

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

RANGE HOODS RANGE HOOD INSTALLATION & OPERATIONS MANUAL

RANGE HOODS RANGE HOOD INSTALLATION & OPERATIONS MANUAL

MODELS SHOWN: HPCB48NS 48-INCH PROFESSIONAL SERIES CHIMNEY WALL HOOD AND PRD486JDGU 48-INCH PROFESSIONAL SERIES PRO GRAND DUAL-FUEL RANGE

VCIN48JP 48-INCH CUSTOM INSERT PROFESSIONAL SERIES

GE Appliances. Vent Systems. Downdraft. Owner s Manual JVB36 JVB66

Featuring Bake & Brown Convection Product Dimensions. Bake & Microwave Option

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

MODELS SHOWN: HPCB48NS 48-INCH PROFESSIONAL SERIES CHIMNEY WALL HOOD AND PRD486JDGU 48-INCH PROFESSIONAL SERIES PRO GRAND DUAL-FUEL RANGE

INSTALLATION INSTRUCTIONS ELECTRIC COOKTOP MODELS: CTE36P, CTE48P

E64000 SERIES INTENDED FOR DOMESTIC COOKING ONLY

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Fits-More Capacity. Extra-large microwave provides 1.6 Cu. Ft. of cooking space and will hold almost any dish even a 13" x 9" baking dish.

Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330*

GAS COOKTOP INSTALLATION INSTRUCTIONS

Fits-More Capacity. Extra-large microwave provides 1.6 Cu. Ft. of cooking space and will hold almost any dish even a 13" x 9" baking dish.

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View

VCIN48GWS 48-INCH CUSTOM INSERT PROFESSIONAL SERIES

Product Dimensions Page 1 of 7. DA Downdraft Ventilation Hood

JP380BVBB - GE 30" Patio Grill with Downdraft Venting System

Professional Performance for the Home TM

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

SpaceWise Rack Our SpaceWise Rack creates more room so you can cook multiple dishes at once.

Over-the-Range Microwave

Over-the-Range Microwave professional series

READ AND SAVE THESE INSTRUCTIONS Page 1

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

PH48GS 27-INCH DEPTH WALL HOOD (48-INCH WIDTH) PROFESSIONAL SERIES

PH60GWS 27-INCH DEPTH WALL HOOD (60-INCH WIDTH) PROFESSIONAL SERIES

Installation. Use & Care

Installation Instructions

Installation Instructions

E64000LC SERIES ! INTENDED FOR DOMESTIC COOKING ONLY! READ AND SAVE THESE INSTRUCTIONS

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

Over the Range Convection Microwave Oven. Installation Instructions. Model: OTR111SU TINSEB399WRRZ

HPCN36NS 36-INCH CHIMNEY WALL HOOD PROFESSIONAL SERIES

SpaceWise Rack Our SpaceWise Rack creates more room so you can cook multiple dishes at once.

Installation Instructions

Glass Canopy Wall-Mount Hood

READ AND SAVE THESE INSTRUCTIONS

Consider using this two drawer unit in conjunction

One of the more popular models of the Integrated

Duo-Aire. VAC-1 Vertical Air Curtain Wall Hood Single Plenum

Section 1 - Safety Information Section 2 - Installation: Wall Mount Hoods Section 3 - Installation: Island Mount Hoods

Features and specifications are subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information.

Viking Installation Guide

IMPORTANT SAFETY INSTRUCTIONS

Combination. IMPORTANT: Read and save. these instructions. Par-t No W / Rev. A

INSTALLATION INSTRUCTIONS

Professional Ventilators

Features and specifications are subject to change at any time without notice. Visit subzero.com/specs for the most up-to-date information.

Microwave Oven Hood Combination

Integrated Ventilation System

Direct Vent System. for PELLET STOVES FEATURES. Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system

36 Downdraft Hood Proud Mounting

RANGE HOODS RANGE HOOD INSTALLATION & OPERATIONS MANUAL

E60000LC SERIES ! INTENDED FOR DOMESTIC COOKING ONLY! READ AND SAVE THESE INSTRUCTIONS

Installation Instructions

For those very small galley kitchens where you

The Integrated line of refrigeration is growing literally

E64000 SERIES INTENDED FOR DOMESTIC COOKING ONLY

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

Notable Changes in the Mechanical Codes

64000 SERIES RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

Cooktop Low-Profile Ventilation Hoods

INSTALLATION INSTRUCTIONS

Microwave Oven. IMPORTANT SAFETY INSTRUCTION Never operate the oven when it is empty or without the glass turntable.

BUILT-IN MICROWAVE OVEN INSTALLATION INSTRUCTIONS 24" (61.0 cm), 27" (68.6 cm), 30" (76.2 cm)

Range Hoods Blowers Accessories

Transcription:

REVI SEDVERI SI ON-Noti npr i nt edcat al og

SPECIFICTION SHEET D49M30S, D49M36S, D49M48S DOWNDRFT Powerful VERTEX TM Complete Capture Design rivals the finest island hoods. Compact design allows the choice of many cooktop styles, free-standing and built-in ranges for island or wall applications. FETURES HOUSING: Galvanized steel construction Left, right, front, or rear discharge Flexible installation - can be used with cooktops, rangetops, slide-in, and free-standing ranges 30", 36", or 48" widths - Fits standard-size cabinets (Some blower configurations may require deeper cabinets.) For indoor use only CHIMNEY SSEMLY: Quiet actuation linear drive system Chimney rises 18" when activated - ideal for tall pots luminum mesh filters - easy to remove, dishwasher-safe 304 stainless steel chimney - makes cleanup quick and easy 4-speed capacitive-touch control, with delay off and filter clean reminder Heat Sentry TM adjusts speed of blower in case of excess heat 2-level LED task light. 7W (30"), 14W (36"), 18W (48") Up to 100% capture - equal to comparable island hoods TRIM / DOOR: Low profile 304 stainless steel construction rticulating door to hide chimney when retracted Integrated, capacitive-touch UP button LOWER (sold separately): Compatible with quiet and efficient 600 cfm Flex lower - Model PF6 Permanently lubricated, thermally-protected motor Neoprene, resilient anti-vibration mounts Can be mounted directly to downdraft or mounted remotely Uses standard 8" round duct Can be rotated on housing to exhaust left, right or down Compatible with in-line/exterior blower models: E6, E9, E12, E15, IL3, IL6, IL9, IL11 TYPICL SPECIFICTION Downdraft blower system shall be est Model D49M30S, (D49M36S), (D49M48S). Unit to have stainless steel housing. Chimney to rise 18" and have 304 stainless steel contruction for ease of cleaning. Filters to be aluminum mesh, easy to remove and dishwashersafe. lower will connect directly to 8" round duct. Remote application uses 1-7/8" x 19" to 8" round transition (1-7/8" x 19" to 10" round transition), (8"/10" round plate). lower to discharge left, (right), (front), (rear). Motor shall be mounted to blower assembly with grease resistant anti-vibration mounts, be removable, and lifetime lubricated. Unit to include Heat Sentry TM, to adjust blower speed in case of excess heat. Unit to include trim / door to hide chimney when retracted. Downdraft system shall operate on 120 VC and be able to be plugged into a standard grounded outlet. It will have a 4-speed blower control, with delay off, and filter clean reminder. Downdraft shall include 2-level LED task lighting. Downdraft blower system to be culus listed. SPECIFICTIONS Volts: 120 Hz: 60 mps: 3.2 Duct: 8" Round NOTE: Dimensions shown are for reference only. efore cutting out countertop, refer to instructions packed with downdraft and cooktop. EST Hartford, Wisconsin www.estrangehoods.com 800-558-1711 REFERENCE QTY. REMRKS Project Location rchitect Engineer Contractor Submitted by Date 61 99045243C

INSTLLTION PLNNING D49M30S, D49M36S, D49M48S CINET CUTOUTS! CUTION: EFORE CUTTING HOLE IN CINET FOR DUCTWORK, check for interference with floor joists, wall studs, electrical wiring, or plumbing. RER CORNER OF COOKTOP CUT-OUT INSTLLTION CENTER LINE DOWNDRFT COUNTER TOP COOKTOP 2-1/2" 2-3/4" DOWNDRFT 7 5 / 8 21 4 HOLE 2 FOR 17/ 8 X 19 DUCT & TRNSITIONS 21 centered INSIDE CINET FLOOR 1½ Use the dimensions in the above illustration to help plan how and where to provide duct access through your cabinet. Generally, 1-7/8" x 19" rectangular duct will be used through left, right, and back of cabinet - while 8" round duct will be used through cabinet floor. For left, right, or rear exhaust: llow at least 18" for transition and elbow or blower. For left / right exhaust: 30" deep cabinet is recommended to align properly with flex blower. Flex blower can be mounted to rear cabinet wall or to a platform / frame (not provided) on the base of the cabinet floor. (See flex blower instructions). Cabinet depths of 24" to 30" are required - depending on the type of cooking appliance. ELECTRICL PNEL 24¾ INSIDE CINET CK Hole in Cabinet Floor Dimension Dimension Using Flex lower (Model PF6 & 8" round duct straight down through cabinet floor.) (1½" left of installation center line) 5-5/8 inches The unit has an 30-in. power cord with a 3-pronged plug. Plan to provide a grounded outlet within reach of this cord. 4 Using Exterior or In-Line lower & 90 0 Duct Elbow (on installation center line) 7-5/8 inches (Model 432-8" round elbow) 8-5/8 inches (Model 418-10" round elbow) DUCTWORK * Remote blowers use 8" or D 10" round remote discharge plate instead of flex blower. FRONT TO CK INSIDE CINET DEPTH Refer to the cooktop installation instructions for dimensions of cooktop, countertop cut-out, and cabinet requirements. However, it is recommended that oversized cabinets be used for easier installation. Custom island designs need to account for deeper cabinets - especially when installed with a range in front of the downdraft or when mounting the blower behind the downdraft. You must also plan for an access door. Cooktop depth can vary greatly from one to another. This may cause the fit of these two appliances to be rather tight. Pay special attention to the areas of potential interference highlighted above. countertop with () a raised lip and/or () a backsplash may not allow enough flat countertop for a proper installation. Note that 2-3/4" of flat countertop is required behind cooktop and that 2-1/2" is necessary between the back edge of the cooktop and the inside of cabinet back. HOUSING FLEX LOWER * The downdraft blower system is designed for use with 8" round ductwork using a Flex lower or 10" round ductwork using a remote blower. (Purchase blowers separately.) Six (6) different discharge connections are available - with side-to-side adjustment for accurate alignment of ductwork: = 8" Round, Left Discharge out of Flex lower = 8" Round, Right Discharge out of Flex lower C = 8" Round, Down Discharge out of Flex lower (Electrical Panel to be mounted remotely) D = 1-7/8" x 19", Left Discharge out of Housing to Remote lower or Flex lower in remote location. Use 1-7/8" x 19" to 8" round transition, 1-7/8" x 19" to 10" round transition, or 1-7/8" x 19" ductwork as appropriate. E = 1-7/8" x 19", Right Discharge out of Housing to Remote lower or Flex lower in remote location. Use 1-7/8" x 19" to 8" round transition, 1-7/8" x 19" to 10" round transition, or 1-7/8" x 19" ductwork as appropriate. F = 1-7/8" x 19", Rear Discharge out of Housing to Remote lower or Flex lower in remote location. Use 1-7/8" x 19" to 8" round transition, 1-7/8" x 19" to 10" round transition, or 1-7/8" x 19" ductwork as appropriate. For best performance: Choose the ducting option which allows the shortest length of ductwork and a minimum number of elbows and transitions. Check location of floor joists, wall studs, electrical wiring or plumbing for possible interference. F C ELECTRICL PNEL E

OPTIONL CCESSORIES D49M30S, D49M36S, D49M48S OPTIONL CCESSORY PPLICTION OPTIONL CCESSORY PPLICTION MODEL CRD TSKD30 TSKD36 TSKD48 MD6T MD8T MD10T REMOTEUP/DOWN CONTROL Use when you cannot reach the UP/ DOWN utton on the downdraft chimney. Can be located on counter top, face of cabinetry or on the side cabinet of an island. Cut-out size: 2¼" H x 2" W. Cannot be used where remote control will interfere with cooking, where hot pans could be set, or where hot liquids could be spilled on the control. Remote wiring connects with 6-pin connector on control box. GS COOKTOP SEL KIT Recommended for use with all gas cooktops. Includes trim bracket and trim seal. 30", 36" & 48" widths. MKE-UP IR DMPER Use to provide make-up air when called for to keep the home comfortable by allowing the downdraft to operate at optimum levels. Directwire design works with select EST downdrafts to balance indoor air pressure by providing interlocked make-up air; damper opens automatically when the range hood is activated 8" round & 10" round diameters. Connects to 2 CONTCTS on ELECTRICL PNEL. MODEL EWD5 MODEL NKD MODEL FCD MODEL VDKD8 EXTENSION CLE - 5-FT. Use where electrical panel is remotely mounted. Extends electrical panel cable an additional 5-feet. NON-DUCT RECIRCULTING KIT Use where ducting is not feasible or available. Mount to toe kick or base of a cabinet and attach directly to Model PF6 Flex lower using 8" round duct. Kit can be rotated so that the exhaust is not directly at your feet. Includes recirculation filter and decorative cover plate. RECIRCULTION FILTER REPLCEMENT Replacement filter for NKD Non-Duct Recirculating Kit. Use to effectively capture cooking contaminants. 1-7/8" X 19" TO 8" ROUND TRNSITION Rectangular to 8" round transition for left, right, or rear exhaust - using Model PF6 Flex lower. Can be attached to downdraft unit or rectangular duct (EDD2). Includes S-clips for easy, secure attachment. MKE-UP IR DMPER CONTCTS 1-7/8" X 19" TO 10" ROUND TRNSITION Rectangular to 10" round transition for left, right, or rear exhaust - using Model PF6 Flex lower. Can be attached to downdraft unit or rectangular duct (EDD2). Includes S-clips for easy, secure attachment. MODEL VDKD10 TKD30S TKD36S TKD48S RNGE TRIM KIT Use with free-standing range - where a gap is present between back of range and downdraft. 30", 36" & 48" widths. MODEL VDKD219 RECTNGULR DPTOR FOR 1-7/8" X 19" Use to connect 1-7/8" x 19" rectangular duct directly to downdraft when using side or rear exhaust.

OPTIONL CCESSORIES D49M30S, D49M36S, D49M48S (CONTINUED) OPTIONL CCESSORY PPLICTION END CP TRIM EXTENSION +1" WIDTH - LH & RH Use left and right to increase the overall trim width by 1" - to 31", 37" and 49". MODEL TTD1 FRONT PNEL ROUGH-IN PLTE - 8" ROUND Use where 8" round duct or elbow attaches to front of airbox (Model PF6 remote blower installation). MODEL CVPD8 FRONT PNEL ROUGH-IN PLTE - 10" ROUND Use where 10" round duct or elbow attaches to front of airbox (exterior or in-line blower installation). MODEL CVPD10 90 0 DUCTWORK ELOW djustable from straight to 90 0. MODEL 432-8" RD. MODEL 418-10" RD. STRIGHT ROUND DUCT - 2-FT. MODEL 408-8" RD. MODEL 410-10" RD. RECTNGULR DUCT - 2-FT. SECTIONS (1-7/8" X 19") MODEL EDD2