CATTURA TM DOWNDRAFT MODELS D49M30SB, D49M36SB, D49M48SB

Similar documents
MODELS D49M30SB, D49M36SB, D49M48SB DOWNDRAFT

CAUTION signals a situation where minor injury or product damage may occur if you do not follow instructions.

READ AND SAVE THESE INSTRUCTIONS

VIPR Professional Downdraft w/remote

Downdraft Ventilation

ducted / recirculating separately 2.1 WS / 11.8 HS 3-stage Rear Yes (600 CFM options sold separately) 29 3/8" x 31" x 2 3/4" 6" or 8"

USE / INSTALLATION GUIDE

Cooktop Chimney Ventilation Hoods

USE / INSTALLATION GUIDE

gas cooktops EW30GC55P S / B

Installation Instructions

UCVM36RS 36-INCH DOWNDRAFT VENTILATION MASTERPIECE SERIES. GENERAL PROPERTIES Operating Mode Convertible: Ducted / Recirculating

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

UseandCare & Installation Guide

ERV3015, ERV3615. Renaissance 30, 36 Wide, High Extension Slim Raised Vents. Top cap with vent down

READ AND SAVE THESE INSTRUCTIONS

VCI248DS 48-INCH CUSTOM INSERT MASTERPIECE SERIES

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

! INTENDED FOR DOMESTIC COOKING ONLY!

ERV3015, ERV3615, ERV36-ER, ERV48, ERV48-ER, PRV30, PRV36, PRV48

UCVM30FS 30-INCH DOWNDRAFT VENTILATION MASTERPIECE SERIES

Installation Instructions

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

PH36HWS 24-INCH DEPTH WALL HOOD (36-INCH WIDTH) PROFESSIONAL SERIES

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330*

HPCN48WS 48-INCH CHIMNEY WALL HOOD PROFESSIONAL SERIES

GE Appliances. Vent Systems. Downdraft. Owner s Manual JVB36 JVB66

Product Dimensions Page 1 of 7. DA Downdraft Ventilation Hood

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Installation Instructions

JP380BVBB - GE 30" Patio Grill with Downdraft Venting System

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View

PH48HWS 24-INCH DEPTH WALL HOOD (48-INCH WIDTH) PROFESSIONAL SERIES

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Featuring Bake & Brown Convection Product Dimensions. Bake & Microwave Option

MODELS SHOWN: HPCB48NS 48-INCH PROFESSIONAL SERIES CHIMNEY WALL HOOD AND PRD486JDGU 48-INCH PROFESSIONAL SERIES PRO GRAND DUAL-FUEL RANGE

Installation Instructions

RANGE HOODS RANGE HOOD INSTALLATION & OPERATIONS MANUAL

RANGE HOODS RANGE HOOD INSTALLATION & OPERATIONS MANUAL

VCIN48JP 48-INCH CUSTOM INSERT PROFESSIONAL SERIES

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

VCIN48GWS 48-INCH CUSTOM INSERT PROFESSIONAL SERIES

Over the Range Convection Microwave Oven. Installation Instructions. Model: OTR111SU TINSEB399WRRZ

Installation Instructions

GAS COOKTOP INSTALLATION INSTRUCTIONS

Featuring Bake & Brown Convection Product Dimensions. Bake & Microwave Option

READ AND SAVE THESE INSTRUCTIONS Page 1

MODELS SHOWN: HPCB48NS 48-INCH PROFESSIONAL SERIES CHIMNEY WALL HOOD AND PRD486JDGU 48-INCH PROFESSIONAL SERIES PRO GRAND DUAL-FUEL RANGE

Professional Performance for the Home TM

PH60GWS 27-INCH DEPTH WALL HOOD (60-INCH WIDTH) PROFESSIONAL SERIES

Fits-More Capacity. Extra-large microwave provides 1.6 Cu. Ft. of cooking space and will hold almost any dish even a 13" x 9" baking dish.

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

Fits-More Capacity. Extra-large microwave provides 1.6 Cu. Ft. of cooking space and will hold almost any dish even a 13" x 9" baking dish.

Glass Canopy Wall-Mount Hood

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

Viking Installation Guide

Integrated Ventilation System

Professional Ventilators

SpaceWise Rack Our SpaceWise Rack creates more room so you can cook multiple dishes at once.

READ AND SAVE THESE INSTRUCTIONS

Over-the-Range Microwave professional series

PH48GS 27-INCH DEPTH WALL HOOD (48-INCH WIDTH) PROFESSIONAL SERIES

RANGETOPS. Features and specifications are subject to change at any time without notice. Throughout this guide, dimensions may vary by ± 3 mm.

Over-the-Range Microwave

Installation. Use & Care

Microwave Oven. IMPORTANT SAFETY INSTRUCTION Never operate the oven when it is empty or without the glass turntable.

INSTALLATION INSTRUCTIONS

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

SpaceWise Rack Our SpaceWise Rack creates more room so you can cook multiple dishes at once.

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

PML SD Ventilators. Professional Mesh Liners Technical Features: Dimmer controlled halogen lighting

APPUZO RANGE HOOD INSTALLATION

GE Monogram. Installation. Instructions. Professional Gas Cooktops 48" Natural Gas Models ZGU48N4GWSS ZGU48N6RWSS ZGU48N6DWSS

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

Downdraft Raised Vent

Section 1 - Safety Information Section 2 - Installation: Wall Mount Hoods Section 3 - Installation: Island Mount Hoods

READ AND SAVE THESE INSTRUCTIONS

HPCN36NS 36-INCH CHIMNEY WALL HOOD PROFESSIONAL SERIES

WP29M SERIES INTENDED FOR DOMESTIC COOKING ONLY

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

Installation Instructions Preference Wall Mount Range Hood

64000 SERIES RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS

Notable Changes in the Mechanical Codes

Combination. IMPORTANT: Read and save. these instructions. Par-t No W / Rev. A

I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS

CLEANING & MAINTENANCE For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild d

Installation. Professional Built-in Hoods

Features and specifications are subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information.

Use, Care, and Installation Guide

Please Read and Save These Instructions Safety Information

RANGE HOODS RANGE HOOD INSTALLATION & OPERATIONS MANUAL

If you want to offer a more professional look to your

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

Installation Instructions

Range Hoods. Owner s Manual Pour version française, visitez notre site à l adresse Page 2 - Safety Information

Range Hoods. Owner s Manual. Page 2 - Safety and Installation Guide

Use, Care, and Installation Guide

Use, Care, and Installation Guide READ AND SAVE THESE INSTRUCTIONS

Transcription:

SPECIFICATIONS CATTURA TM DOWNDRAFT MODELS D49M30SB, D49M36SB, D49M48SB Page 1 Powerful VERTEX TM Complete Capture Design rivals the finest island hoods. Compact design allows the choice of many cooktop styles, free-standing and built-in ranges for island or wall applications. FEATURES HOUSING: Galvanized steel construction Left, right, front, or rear discharge Flexible installation - can be used with cooktops, rangetops, slide-in, and free-standing ranges 30", 36", or 48" widths - Fits standard-size cabinets (Some blower configurations may require deeper cabinets.) For indoor domestic use only CHIMNEY ASSEMBLY: Quiet actuation linear drive system Chimney rises 18" when activated - ideal for tall pots Aluminum mesh filters - easy to remove, dishwasher-safe 304 stainless steel chimney - makes cleanup quick and easy 4-speed capacitive-touch control, with delay off and filter clean reminder Heat Sentry TM adjusts speed of blower in case of excess heat 2-level LED task light. 7W (30"), 14W (36"), 18W (48") Up to 100% capture - equal to comparable island hoods TRIM / DOOR: Low profile 304 stainless steel construction Articulating door to hide chimney when retracted Integrated, capacitive-touch UP button BLOWER : Compatible with quiet and efficient 600 cfm Flex Blower - Model PF6 Permanently lubricated, thermally-protected motor Neoprene, resilient anti-vibration mounts Can be mounted directly to downdraft or mounted remotely Uses standard 8" round duct Can be rotated on housing to exhaust left, right or down Compatible with in-line/exterior blower models: EB6, EB9*, EB12*, EB15*, ILB3, ILB6, ILB9, ILB11* *Recommended models TYPICAL SPECIFICATION Downdraft blower system shall be Best Model D49M30SB, (D49M36SB), (D49M48SB). Unit to have stainless steel housing. Chimney to rise 18" and have 304 stainless steel contruction for ease of cleaning. Filters to be aluminum mesh, easy to remove and dishwashersafe. Blower will connect directly to 8" round duct. Remote application uses 1-7/8" x 19" to 8" round transition (1-7/8" x 19" to 10" round transition), (8"/10" round plate). Blower to discharge left, (right), (front), (rear). Motor shall be mounted to blower assembly with grease resistant anti-vibration mounts, be removable, and lifetime lubricated. Unit to include Heat Sentry TM, to adjust blower speed in case of excess heat. Unit to include trim / door to hide chimney when retracted. Downdraft system shall operate on 120 VAC and be able to be plugged into a standard grounded outlet. It will have a 4-speed blower control, with delay off, and filter clean reminder. Downdraft shall include 2-level LED task lighting. Downdraft blower system to be culus listed. SPECIFICATIONS Volts: 120 Hz: 60 Amps: 3.2 Duct: 8" Round NOTE: Dimensions shown are for reference only. Before cutting out countertop, refer to instructions packed with downdraft and cooktop. BEST Hartford, Wisconsin www.bestrangehoods.com 800-558-1711 REFERENCE QTY. REMARKS Project Location Architect Engineer Contractor Submitted by Date 61D 99045243D

PLANNING CABINET CUTOUTS DOWNDRAFT Page 2! CAUTION: BEFORE CUTTING HOLE IN CABINET FOR DUCTWORK, check for interference with floor joists, wall studs, electrical wiring, or plumbing. A COUNTER TOP 2-1/2" 2-3/4" 7 5 / 8 21 REAR CORNER OF COOKTOP CUT-OUT 4 INSIDE CABINET FLOOR INSTALLATION CENTER LINE HOLE 2 FOR INSIDE 17/ 8 X 19 CABINET BACK DUCT & TRANSITIONS 24¾ 21 centered 1½ Hole in Cabinet Floor Dimension A Dimension B Using Flex Blower (Model PF6 & 8" round duct straight down through cabinet floor.) (1½" left of installation center line) 5-5/8 inches Use the dimensions in the above illustration to help plan how and where to provide duct access through your cabinet. Generally, 1-7/8" x 19" rectangular duct will be used through left, right, and back of cabinet - while 8" round duct will be used through cabinet floor. For left, right, or rear exhaust: Allow at least 18" for transition and elbow or blower. For left / right exhaust: A 30" deep cabinet is recommended to align properly with flex blower. Flex blower can be mounted to rear cabinet wall or to a platform / frame (not provided) on the base of the cabinet floor. (See flex blower instructions). Cabinet depths of 24" to 30" are required - depending on the type of cooking appliance. ELECTRICAL PANEL The unit has a 30-in. power cord with a 3-pronged plug. Plan to provide a grounded outlet within reach of this cord. 4 B A Using Exterior or In-Line Blower & 90 0 Duct (on installation center line) 7-5/8 inches (Model 432-8" round elbow) 8-5/8 inches (Model 418-10" round elbow) DUCTWORK * Remote blowers use 8" or D 10" round remote discharge plate instead of flex blower. COOKTOP DOWNDRAFT FRONT TO BACK INSIDE CABINET DEPTH Refer to the cooktop installation instructions for dimensions of cooktop, countertop cut-out, and cabinet requirements. However, it is recommended that oversized cabinets be used for easier installation. Custom island designs need to account for deeper cabinets - especially when installed with a range in front of the downdraft or when mounting the blower behind the downdraft. You must also plan for an access door. Cooktop depth can vary greatly from one to another. This may cause the fit of these two appliances to be rather tight. Pay special attention to the areas of potential interference highlighted above. A countertop with (A) a raised lip and/or (B) a backsplash may not allow enough flat countertop for a proper installation. Note that 2-3/4" of flat countertop is required behind cooktop and that 2-1/2" is necessary between the back edge of the cooktop and the inside of cabinet back. A HOUSING FLEX BLOWER * The downdraft blower system is designed for use with 8" round ductwork using a Flex Blower or 10" round ductwork using a remote blower. (Purchase blowers separately.) Six (6) different discharge connections are available - with side-toside adjustment for accurate alignment of ductwork: A = 8" Round, Left Discharge out of Flex Blower B = 8" Round, Right Discharge out of Flex Blower C = 8" Round, Down Discharge out of Flex Blower ( to be mounted remotely) D = 1-7/8" x 19", Left Discharge out of Housing to Remote Blower or Flex Blower in remote location. Use 1-7/8" x 19" to 8" round transition, 1-7/8" x 19" to 10" round transition, or 1-7/8" x 19" ductwork as appropriate. E = 1-7/8" x 19", Right Discharge out of Housing to Remote Blower or Flex Blower in remote location. Use 1-7/8" x 19" to 8" round transition, 1-7/8" x 19" to 10" round transition, or 1-7/8" x 19" ductwork as appropriate. F = 1-7/8" x 19", Rear Discharge out of Housing to Remote Blower or Flex Blower in remote location. Use 1-7/8" x 19" to 8" round transition, 1-7/8" x 19" to 10" round transition, or 1-7/8" x 19" ductwork as appropriate. For best performance: Choose the ducting option which allows the shortest length of ductwork and a minimum number of elbows and transitions. Check location of floor joists, wall studs, electrical wiring or plumbing for possible interference. F C B ELECTRICAL PANEL B E

OPTIONAL ACCESSORIES Page 3 OPTIONAL ACCESSORY DESCRIPTION / APPLICATION OPTIONAL ACCESSORY DESCRIPTION / APPLICATION MODEL ACRD MODELS ATSKD30 ATSKD36 ATSKD48 MODELS MD6T MD8T MD10T REMOTEUP/DOWN CONTROL Use when you cannot reach the UP/ DOWN Button on the downdraft chimney. Can be located on counter top, face of cabinetry or on the side cabinet of an island. Cut-out size: 2¼" H x 2" W. Cannot be used where remote control will interfere with cooking, where hot pans could be set, or where hot liquids could be spilled on the control. Remote wiring connects with 6-pin connector on control box. GAS COOKTOP SEAL KIT Recommended for use with all gas cooktops. Includes trim bracket and trim seal. 30", 36" & 48" widths. MAKE-UP AIR DAMPER Use to provide make-up air when called for to keep the home comfortable by allowing the downdraft to operate at optimum levels. Directwire design works with select BEST downdrafts to balance indoor air pressure by providing interlocked make-up air; damper opens automatically when the range hood is activated 8" round & 10" round diameters. Connects to 2 CONTACTS on ELECTRICAL PANEL. MODEL ANKD MODEL AFCD MODEL AVDKD8 EXTENSION CABLE - 5-FT. Use where electrical panel is remotely mounted. Extends electrical panel cable an additional 5-feet. NON-DUCT RECIRCULATING KIT Use where ducting is not feasible or available. Mount to toe kick or base of a cabinet and attach directly to Model PF6 Flex Blower using 8" round duct. Kit can be rotated so that the exhaust is not directly at your feet. Includes recirculation filter and decorative cover plate. RECIRCULATION FILTER REPLACEMENT Replacement filter for ANKD Non-Duct Recirculating Kit. Use to effectively capture cooking contaminants. 1-7/8" X 19" TO 8" ROUND TRANSITION Rectangular to 8" round transition for left, right, or rear exhaust - using Model PF6 Flex Blower. Can be attached to downdraft unit or rectangular duct (AEDD2). MAKE-UP AIR DAMPER CONTACTS 1-7/8" X 19" TO 10" ROUND TRANSITION Rectangular to 10" round transition for left, right, or rear exhaust - using Model PF6 Flex Blower. Can be attached to downdraft unit or rectangular duct (AEDD2). MODEL AVDKD10 MODELS ATKD30SB ATKD36SB ATKD48SB RANGE TRIM KIT Use with free-standing range - where a gap is present between back of range and downdraft. 30", 36" & 48" widths. MODEL AVDKD219 RECTANGULAR ADAPTOR FOR 1-7/8" X 19" Use to connect 1-7/8" x 19" rectangular duct directly to downdraft when using side or rear exhaust.

OPTIONAL ACCESSORIES Page 4 OPTIONAL ACCESSORY DESCRIPTION / APPLICATION OPTIONAL ACCESSORY DESCRIPTION / APPLICATION END CAP TRIM EXTENSION +1" WIDTH - LH & RH Use left and right to increase the overall trim width by 1" - to 31", 37" and 49". Y-DUCT CONNECTOR 10" round to dual 8" round. Galvanized steel construction. MODEL ATTD1 FRONT PANEL ROUGH-IN PLATE - 8" ROUND Use where 8" round duct or elbow attaches to front of airbox (Model PF6 remote blower installation). MODEL AVDKD8810 MODEL ACVPD8 FRONT PANEL ROUGH-IN PLATE - 10" ROUND Use where 10" round duct or elbow attaches to front of airbox (exterior or in-line blower installation). MODEL ACVPD10 90 0 DUCTWORK ELBOW Adjustable from straight to 90 0. Galvanized steel construction. MODEL 432-8" RD. MODEL 418-10" RD. STRAIGHT ROUND DUCT - 2-FT. Galvanized steel construction. MODEL 408-8" RD. MODEL 410-10" RD. RECTANGULAR DUCT - 2-FT. SECTIONS (1-7/8" X 19") Galvanized steel construction. MODEL AEDD2

OPTIONAL ACCESSORIES Page 5 MODEL ATTD1 End Cap Trim Extensions (Increases trim width 1-inch to 31, 37, or 49 inches.) MODEL ATKD30SB, 36, 48 Range Trim Kit (Option to fill gap between range and downdraft.) MODEL ATSKD30, 36, 48 Gas Cooktop Seal Kit (Recommended for use with gas cooktops.) MODEL ACRD Remote Up/Down Control

SYSTEM DIMENSIONS Page 6 7.500 5.750 PF6 FLEX BLOWER 12.750 11.560 30.000 36.000 48.000 SIDE DUCTING 24.000 7.500 6.000 AVDKD10 1-7/8 X 19 TO 10 RD. TRANSITION PF6 FLEX BLOWER 12.750 11.586 FRONT OUTLET 4.240 7.320 FRONT 27.152 33.152 45.152 AEDD2 1-7/8 X 19 RECTANGULAR DUCT 24.000 19.000 12.750 AVDKD8 1-7/8 X 19 TO 8 RD. TRANSITION 5.000 SIDE INLET OUTLET 5.272 10.310 15.952 14.048 7.976 11.586 D49M30SB D49M36SB D49M48SB DOWNDRAFT 408 (8 ) OR 410 (10 ) ROUND DUCT FRONT ANKD NON-DUCT RECIRCULATION KIT 16.000 17.478 6.478 11.000 3.750 SIDE REAR DUCTING FRONT REAR AEDD2 1-7/8 X 19 RECTANGULAR DUCT 2.410 24.000 AVDKD10 1-7/8 X 19 TO 10 RD. TRANSITION 1.875 5.750 7.500 6.000 7.500 AVDKD8 1-7/8 X 19 TO 8 RD. TRANSITION 10.000 12.063 13.813 8.250 9.517 8.000 10.984 5.528 8.250 13.000 7.000 11.000 418 10 RD. ELBOW 423 8 RD. ELBOW

INTERNAL BLOWER (PF6) - FRONT MOUNTED TO DOWNDRAFT Flex Blower (PF6) attached to front of Downdraft in cabinet Page 7 Ducted to Wall Cap or Non-Duct Recirculation Kit MODEL PF6 Flex Blower ( Down discharge shown. Blower can also be rotated for Left or Right discharge.) (Mount in 5-foot Extension Cable (Only required if is more than 2-feet away from downdraft. Use up to 2 Extension Cables connected together.) MODEL 432 * MODEL 643 * MODEL ANKD Non-Duct Recirculation Kit * As required - sold separately. with kickspace grille (Only required for Non-Duct applications. Front discharge shown. Kit can also be rotated for Left, Right or Rear discharge.)

INTERNAL BLOWER (PF6) - REMOTE MOUNTED - FRONT OUTLET Ducting connected to front of Downdraft Page 8 Flex Blower in cabinet - or - in remote, in-line location Ducted to MODEL ACVPD8 Front Rough-in Plate MODEL 432 * (Can be mounted in 5-foot Extension Cable (Only required if is mounted in a remote location - more than 2-feet away from downdraft. Use up to 2 Extension Cables connected together.) * As required - sold separately. MODEL PF6 Flex Blower MODEL 643 *

INTERNAL BLOWER (PF6) - REMOTE MOUNTED - SIDE OR REAR OUTLET Ducting connected to right side of Downdraft (Ducting connects to left side or rear of downdraft in same manner.) Flex Blower mounted in a side cabinet or other remote, in-line location Ducted to or Non-Duct Recirculation Kit Page 9 MODEL AVDKD219 * Rectangular Transition (Only required to extend duct along back of cabinet.) MODEL AEDD2 * Rectangular Duct (Only required to extend duct along back of cabinet.) MODEL AVDKD8 1-7/8-inch to 8-inch Round Transition MODEL PF6 Flex Blower (Mounted in side cabinet.) (Can be mounted in 5-foot Extension Cable (Only required if Electrical Panel is mounted in a remote location - more than 2-feet away from downdraft. Use up to 2 Extension Cables connected together.) MODEL 643 * MODEL 423 * MODEL 408 * 8-inch Round Straight Duct MODEL PF6 Flex Blower (Mounted in * As required - sold separately. MODEL ANKD Non-Duct Recirculation Kit with kickspace grille (Only required for Non-Duct applications. Front discharge shown. Kit can also be rotated for Left, Right or Rear discharge.)

INTERNAL BLOWER (PF6) - REMOTE MOUNTED - REAR OUTLET Ducting connected to rear of Downdraft Page 10 Flex Blower in side cabinet or other remote, in-line location Ducted to or Non-Duct Recirculation Kit MODEL AEDD2 * Rectangular Duct MODEL AVDKD8 1-7/8-inch to 8-inch Round Transition MODEL AVDKD219 * Rectangular Transition MODEL PF6 Flex Blower (Mounted in adjacent cabinet.) MODEL 432 * MODEL 643 * MODEL PF6 Flex Blower (Mounted in * As required - sold separately. MODEL ANKD Non-Duct Recirculation Kit with kickspace grille (Only required for Non-Duct applications. Front discharge shown. Kit can also be rotated for Left, Right or Rear discharge.)

EXTERIOR OR IN-LINE BLOWER - FRONT OUTLET EB15 is recommended for all rangetops or cooktops with grill & any 48-inch wide rangetop or cooktop Ducting connected to front of Downdraft 10-inch round duct connected to In-Line or MODEL ACVPD10 Front Rough-in Plate Page 11 (Can be mounted in (Standard 120VAC wiring rated for 6A minimum - sold separately.) 5-foot Extension Cable (Only required if Electrical Panel is mounted in a remote location - more than 2-feet away from downdraft. Use up to 2 Extension Cables connected together.) MODEL 418 * MODEL 410 * MODEL EB9 ** 900 cfm MODEL 418 * MODEL 441 * MODEL 410 * MODEL ILB11 ** 1100 cfm In-Line Blower * As required - sold separately. ** Choose 1 exterior or in-line blower - sold separately. MODEL EB12 ** MODEL EB15 ** 1200 cfm -- OR -- 1500 cfm

EXTERIOR OR IN-LINE BLOWER - SIDE OR REAR OUTLET EB15 with dual duct (see next page) is recommended for all rangetops or cooktops with grill & any 48-inch wide rangetop or cooktop Ducting connected to side or rear of Downdraft 10-inch round duct connected to In-Line or Page 12 MODEL AVDKD219 * Rectangular Transition (Only required to extend duct along back of cabinet.) MODEL AEDD2 * Rectangular Duct (Only required to extend duct along back of cabinet.) MODEL AVDKD10 1-7/8-inch to 10-inch Round Transition MODEL 418 * (Can be mounted in (Standard 120VAC wiring rated for 6A minimum - sold separately.) 5-foot Extension Cable (Only required if Electrical Panel is mounted in a remote location - more than 2-feet away from downdraft. Use up to 2 Extension Cables connected together.) MODEL 410 * MODEL EB9 ** 900 cfm MODEL 418 * MODEL 441 * MODEL 410 * MODEL ILB11 ** 1100 cfm In-Line Blower * As required - sold separately. ** Choose 1 exterior or in-line blower - sold separately. MODEL EB12 ** MODEL EB15 ** 1200 cfm -- OR -- 1500 cfm

EXTERIOR OR IN-LINE BLOWER - DUAL DUCT - SIDE OUTLETS EB15 is recommended for all rangetops or cooktops with grill & any 48- inch wide rangetop or cooktop Ducting connected to right and left sides of Downdraft (Ducting may be connected to either side & rear of downdraft in same manner.) 8-inch round duct connected to Dual 8-inch to 10-inch round Transition 10-inch round duct connected to Exterior or In-Line Blower MODEL AVDKD219 * Rectangular Transition (Only required to extend duct along back of cabinet.) MODEL AEDD2 * Rectangular Duct (Only required to extend duct along back of cabinet.) MODEL AVDKD8 1-7/8-inch to 8-inch Round Transition MODEL 423 * 8-inch Round Page 13 (Left-side duct sytem. Similar to Right-side.) (Standard 120VAC wiring rated for 6A minimum - sold separately.) (Can be mounted in 5-foot Extension Cable (Only required if Electrical Panel is mounted in a remote location - more than 2-feet away from downdraft. Use up to 2 Extension Cables connected together.) MODEL AVDKD8810 Dual to Transition MODEL EB9 ** 900 cfm MODEL 418 * MODEL 441 * MODEL 410 * MODEL ILB11 ** 1100 cfm In-Line Blower MODEL EB12 ** MODEL EB15 ** 1200 cfm -- OR -- 1500 cfm * As required - sold separately. ** Choose 1 exterior or in-line blower - sold separately.