MAXLITE RKT LED Retrofit Kit

Similar documents
Lumination TM Volumetric Retrofit Kit

USER MANUAL INSTALLATION GUIDE FOR: 2X2: MLFP22DS4035 MLFP22DS4041 MLFP22DS4050


Dioluce Products Installation Instructions

IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician.

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

PH:

Installation Instructions

PH:

1 x4 Dimmable LED RetroFits

Innovative Lighting Smooth Light Recessed Luminaires

ETG-LRP Series. 4 LED Remote Phosphor Linear Low Bay and High Bay Lighting. Figure 1-2 tube LRP with reflector shown

Honeywell Durafit LED Retrofit Kit

1 General Description

LED Flat Panel Retrofit

Lumination TM Controls Accessory LPL Series Controller Box

Tetra MAX. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

Lunera Smart T8 4ft. Installation Guide. Installation Description

MaxLite LED Round Pendant Highbay Series

Cold Door 2 LED Retrofit Kit Lighting System

INSTALLATION INSTRUCTION In-Ground

Installation Instructions

Dimmable LED Retrofit Kit

LED FLAT PANEL EDGE LIT MLFP SERIES G2

INSTALLATION INSTRUCTION In-Ground Color Changing

Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended

Cold Deck Canopy and Shelf Lights and Retrofit Kit

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

CDL8 LED Architectural

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits

Innovative Lighting R-Series Overhead LED Conversion Kits

LED Emergency Battery Backup

LED Ceilencio. Specifically designed for

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

Installation guide. Philips EvoKit LED 2x4 and 2x2

TROFFER RETROFIT KIT (TRK)

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

LED Seamless VaporProof Fixture

FES - Series Portable Electric Heaters

SERVICE BY QUALIFIED PERSONNEL ONLY

LED Dusk to Down Fixture

Innovative Lighting R-Series Vertical Refrigeration

Warmup DS-2C RAIN/SNOW SENSOR CONTROLLER INSTALLATION MANUAL AUTOMATED SYSTEMS ENGINEERING ENCLOSURE TYPE 3R

BAYMAX TM LED LINEAR HIGHBAY FIXTURE BLHT SERIES

Escape Series Walk-in Bathtub Models 5128 and 5332 (soaker, water, air and microbubble jet models)

DESIGNED SPECIFICALLY FOR QUICK AND EASY WATERPROOF INSTALLATION.

APPLICATIONS SPECIFICATION FEATURES ORDERING. Project: Notes: Catalog #: Large Outdoor Spaces. Swimming Pools. Shopping Malls. Large Indoor Spaces

INSTALLATION INSTRUCTIONS

LED Shoplight fixture

Installation Instructions

DHL-LP-LED Low Profile LED Linear High/Low Bay

HIGH LUMINOUS EFFICIENCY

LED Lighting: Technology Selection and System Commissioning Course Number: CXENERGY1519

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

Catalog Number. Notes

with motion sensor ITM. / ART Model: LM55811 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY

ESRB and ESRN Installation & Safety Instructions

EMERGENCY POWERHUBB NODE INSTALLATION AND OPERATION GUIDE

WARRANTY LED ECO PANEL.

Sylproof Superia LED G2

Douglas Lighting Controls. Bluetooth Fixture Controller & Sensor. Installation Manual BT-FMS-A. *Patent Pending. Installation Guide BT-FMS-A v7

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

HIGH BAY APPLICATIONS

INSTALLATION INSTRUCTIONS

PEDESTAL INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DU PIÉDESTAL

SOLA SM II Light Engine Instruction Manual

Classix 6" 6" Round Adjustable C3

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400

Installation Instructions If you have questions, call or visit our website at:

CHALICE RECESSED LED DOWNLIGHT 70 Watt LED

Installation Instructions

LED ROUND MINI PANELS

THINTEK G2 PANEL.

THINTEK G2 PANEL.

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Canadian Model Number Designations. Models ending in... LED-8030M42 C-A = 347V LED-8030M42 -A = 120/277V LED-8030M42 C = 120/347V

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

Classix 6" 6" Round Lens Wall Wash

New LED Product Offerings

Classix 6" 6" Round Lens Wall Wash

Premium. Universal LED Vapor Tight T20G. Commercial lighting Industrial lighting Vapor tight light Linear High Bay Canopy

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Classix 6" 6" Round Adjustable C3

Product Specifications

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

Project Name. Date. Cat. Number. Type

AB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document

MODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions

LED FIXTURE CATALOG. Shining light into the future

PRELIMINARY 2000K PERFORMANCE. CRI Lumen Maintenance Binning Tolerance Warranty

Classix 6" 6" Round Adjustable C3M

Hi-lume 3D Overview. Fluorescent Dimming Ballasts Hi-lume 3D Architectural Dimming

LED ECO PANEL.

LED RETROFIT SOLUTIONS

LED ECO PANEL.

Transcription:

Operating Instructions MAXLITE RKT LED Retrofit Kit Description and Intended Use The RKT LED Retrofit Kit is a high performance LED Fixture upgrade kit designed to replace the original components inside 2 x2 and 2 x4 fluorescent fixtures. The RKT LED Retrofit Kit is suitable for office, school, hospital and medical facility applications. The panels are fully dimmable and compatible with building controls, motion sensors, timers, and daylight harvesting systems. The design of the panels produces an even, consistent shadowless light. The LEDs enable long life, high lumen maintenance, high CRI, and low maintenance, and are constructed without hazardous materials. Construction The LED carriage is constructed of sheet steel, providing heat sink and thermal control capabilities. Attached are four LED strips, constructed from FR4 resin boards, which are mounted onto the carriage with fasteners and added contact via plastic hold down clips. Provisions are also provided to mount the kit to existing fluorescent ceiling panels. Control With a standard integrated driver, the panels operate with a standard 0-10V wall control, (not included) for wall control dimming. Up to 20 panels can be linked to each master panel. Specifications Model Watts Lumen Volts CCT Weight Dimensions(in) L W D RKT4514U5535DV 55W 4,570 120-277V 3500K 8 lb 45 13-5/8 2 RKT4514U5541DV 55W 4,570 120-277V 4100K 8 lb 45 13-5/8 2 RKT4514U5550DV 55W 4,570 120-277V 5500K 8 lb 45 13-5/8 2 RKT2014U4527DV 45W 3,500 120-277V 2700K 6 lb 20 14 2 RKT2014U4535DV 45W 3,590 120-277V 3500K 6 lb 20 14 2 RKT2014U4541DV 45W 4,570 120-277V 4100K 6 lb 20 14 2

Maxlite RKT LED Retrofit Kit 2

General Safety Information 1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 2. Review the diagrams thoroughly before beginning. If you feel you do not have electrical wiring experience, have your fixture installed by a qualified licensed electrician. 3. All electrical connections must be in accordance with local codes, ordinance, and the National Electric Code. If you are unfamiliar with methods of installing electrical wiring, secure the services of a qualified licensed electrician. 4. Before starting the installation, disconnect the power by turning off the circuit breaker or by removing the appropriate fuse at the fuse box. Turning the power off using the light switch is not sufficient to prevent electrical shock. 5. Do not use outdoors. 6. Equipment should be mounted in location and at heights where it will not readily be subject to tampering by unauthorized personnel. 7. Do not use this equipment for other than intended use. 8. All servicing should be performed by qualified personnel only. 1. WARNING - Risk of fire or electric shock. Install this kit only in the luminaires that has the construction features and dimensions shown in the photographs and/or drawings. 2. WARNING - Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation 3. WARNING - Risk of fire or electric shock. Reflector kit installation requires knowledge of fluorescent lighting luminaires electrical systems. If not qualified, do not attempt installation. Contact qualified electrician. 3

Fluorescent Wiring Diagram Rapid Start: Instant Start: 1. REMOVE WIRING, LAMPHOLDERS, BALLASTS, OR ANY OTHER ELECTRICAL COMPONENTS ENLEVEY TOUTES LES CONNECTIONS, CABLES, DOUILLE DE LAMPE, BALLAST ET COMPOSANT ELECTRIQUE 2. MIN LAMP COMPARTMENT DIMENSIONS (SEE PG.1 FOR KIT DIMENSIONS). DIMENSIONS DE COMPARTEMENTS DE LAMPE MINIMUM (VOIRE PG.1 POUR DIMENSIONS) 4

Retrofit Kit Wiring Diagram Connecting panels to AC source supply: 1. All units must be individually connected to the AC supply (120-277 VAC): Black = Line White = Neutral 2. Line connection to be made to switch lead from source. 5

INSTALLATION OF THIS RETROFIT ASSEMBLY REQUIRES A PERSON FAMILIAR THE CONSTRUCTION AND OPERATION OF FLUORESCENT LUMINAIRE ELECTRICAL SYSTEMS AND THE HAZARD INVOLVED CONIFIER L INSTALLATION DE CE NECESSAIRE DE MODERISATION A UNE PERSONNE CONNAISSANT LA CONSTRUCTION ET LE FONCTIONNEMENT DES INSTALLATIONS D ECLAIRAGE FLUORESCENT ET CONSCIENTE DES RISQUES QU ELLES COMPORTENT UNLESS OTHERWISE INDICATED, DO NOT MAKE OR ALTER ANY OPENINGS IN THE COMPARTMENT OF WIRING OR ELECTRICAL COMPONENTS DURING INSTALLATION OF THIS RETROFIT ASSEMBLY. PLUG ALL UNUSED OPENINGS IN THE COMPARTMENT OF WIRING OR ELECTRICAL COMPONENTS A MOINS D INDICATION CONTRAIRE, NE PAS PRATIQUER NI MODIFIER DES OUVERTURES DANS LES COMPARTIMENTS CONTENANT DES CABLES OU DES COMPOSANTS ELECTRIQUES LORS DE L INSTLLATION DE CE NECESSAIRE DE MODERISATION. BOUCHER TOUTES LES OUVERTURES COMPOSANTS ELECTRIQUES TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR OTHER SHARP OBJECTS POUR PREVENIR TOUT DOMMAGE ET USURE, NE PAS EXPOSER LES CIRCUITS AUX BORDS DEL TOLE OU D AUTTRES OBJET POINTUS. DISCONNECT THE POWER BY TURNING OFF THE CIRCUIT BREAKER OR BY REMOVING THE APPROPRIATE FUSE AT THE FUSE BOX. TURNING THE POWER OFF USING THE LIGHT SWITCH IS NOT SUFFICIENT TO PREVENT ELECTRICAL SHOCK. DEBRANCHEZ L ALIMENTATION EN ETEIGNANT LE DISJONCTEUR OU PAR ENLEVER LE CORRECT FUSIBLE DE LA BOITE A FUSIBLES. ETEIGNER L ALIMENTATION EN UTILISANT L INTERRUPTEUR N EST PAS SUFFISANT OUR PREVENIR TOUT DANGER ELECTRIQUE THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A FLUORESCENT LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR AUTHORITIES HAVING JURISDICTION LE NECESSAIRE DE MODERNISATION EST ACCEPTE EN TANT QUE COMPOSANT D UN LUMINAIRE FLUORESCENT, SOUS RESERVE D APPROBATION DE L ENSEMBLE PAR LA CSA OU PAR LES POUVOIRSDE REGLEMENTATION 6

Mounting 1. Remove diffuser, fluorescent tubes and all other internal components. Disconnect fluorescent ballast from power wires. 2. Use safety S hook provided to hang Retrofit Kit to the edge of existing fixture. Once secure, attach existing power wires to Retrofit Kit power wires (Black to Black and White to White). 7

3. Install the fasteners or self-tapping screws provided with the kit to secure the Retrofit kit to the bottom of existing fixture. The self-tapping screws should have a sleeve provided that helps retain them when put through the panel. They also hold the screw in place for one man operation of installing. 4. Reinstall fixture diffuser. 8

Installation & Operation Disconnect the power before installing or serving. Set-up for 0-10V ballast dimmer or building controls: 1. Open access cover 2. Follow connection power on page 5. 3. Connect non relay wires violet/grey from central system to violet/grey wires of driver. 4. Connect relay wires from central system red/blue to red/blue of relay. 5. Connect remaining power wires black from driver to relay line, white wire from driver to relay neutral connect to neutral. 6. Mount panel and operate. 9

Set-up for wall dimming (0-10V): 1. Follow connection power on page 5 2. Connect violet and grey wires from wall dimmer to violet and grey wires on driver. 3. Connect appropriate relay pack if necessary. Follow wire diagram provided. 10

Set-up for linking panels: 1. Follow connection power on page 5. 2. Select one of the panels to be the master panel. 3. Connect dimmer/central system to this panel. 4. Daisy chain remaining panels in zone by connecting violet/grey wires from panel to panel. 5. Up to 20 panels can be linked together with 20 control wiring between each panel. *Lutron PP-20 power pack relay not included. 6. Use 18/20 AWG for control wires. 11