panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Similar documents
Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes

Adjustable Range Reflective Photoelectric Sensor. panasonic.net/id/pidsx/global

Adjustable Range Reflective Photoelectric Sensor. General terms and conditions... F-17 Glossary of terms / General precautions...p.1359~ / P.

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

ER-TF SERIES. Wide-area Ionizer Steady-state DC Method. Slim in shape, Wide in charge removal area, An evolutionary form in expression.

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

Emitter. Emitting circuit. Control circuit. Check. Monitoring section (CPU) Emitting element failure. Emitting circuit failure

Laser Collimated Beam Sensor

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

APS-S/M Series. Polycarbonate Resin Square Type, 2-wire/3-wire DC System. Type. Proximity Sensor. Features

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

E3M-V. Mark Sensor. Applications

Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning. Sensor. Ensure productivity. Emergency stop.

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

Improved productivity Two-stage detection

Flameproof Type Light Curtain Type 4

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Improved productivity Two-stage detection

Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P

SensaGuard TM Integrated Latch Installation Instructions

E3FA PHOTOELECTRIC SENSORS

Ultrasonic Proximity Sensor

Datasheet: K-22 LO Sensor

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

IR FLAME DETECTOR RIV-601/F

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

PHOTOELECTRIC AMPLIFIER SERIES

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

onlinecomponents.com

E3FA PHOTOELECTRIC SENSORS

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

Retro-reflective Sensing range: 0mm to 2000mm

E3FA PHOTOELECTRIC SENSORS

Retroreflective sensor with polarization filter

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

E3FA/E3RA/E3FB/E3RB. Application specific models. Limited-reflective types suitable for detecting transparant film to shiny, mirror film.

Retroreflective sensor with polarization filter

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

M7100 Pressure Transducer

F3UV. Monitoring output state of UV (ultraviolet light)/illumination light source. Ultraviolet power monitor/illumination monitor.

SPACEMOTION SERIES SMM 01

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

Technical Data. Dimensions

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Safety Light Curtains Area Access Control

Ultrasonic Proximity Sensor

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

/ / 2018

TLS 500. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.1.

ISIS SAFETY SYSTEM Installation guide

culus and CE Marked for all applicable directives Operating Environment Operating Temperature [C (F)]

TLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.

Compact, Photoelectric Sensor with Built-in Amplifier and Teaching Function. Mark Sensor with Stainless Steel Housing

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

BES M30EP-PFC12F-S04G-D12 BES Q40ZU-PFC15B-S04G-D12 BES Q40ZU-PFC20F-S04G-D12 Inductive Safety Sensors User's Manual

Reliable Detection of Transparent Objects

Original instructions Sense7-series Non-contact coded safety switch

Laser retro-reflective photoelectric sensor with polarization filter. Dimensioned drawing

Digital Heater Element Burnout Detector K8AC-H

Throughbeam photoelectric sensor for the detection of aqueous liquids. Dimensioned drawing

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Magnetically Coded Non-contact Switch (MC2)

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

Background suppression photo sensors

Selectable 2sec., 7sec., 15sec. (selectable by holding time setting switch)

Contents. Photoelectric Sensors / Standard Sensors...4. Safety Sensors Photoelectric Sensors / Miniature Sensors... 12

Danfoss gas detection units

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

Operating Manual MS220DA

AnyWireASLINK System Products Guide

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

IM 77J01A07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0. Output-2 signal

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

DIGITAL INDICATOR JIR-301-M

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

CARLO GAVAZZI Automation Components. CA18/30 CAN/CAF - Capacitive Sensors

Danfoss gas detection units

16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

Plug-in Base, Long Range Sensor E3B2

Transcription:

687 Optical Touch Switch SW-1 SERIES Related Information General terms and conditions... F-3 General precautions... P.1595 PHOTO PHOTO Conforming to OSHA / ANSI Listing MEASURE panasonic.net/id/pidsx/global This product is used to start up the machinery. Do not use this product as a device for emergency stop. Gentle start-up switches in accordance with ergonomics Greater convenience with less stress on the hands. Inventive start-up switches in accordance with ergonomics. Operate the switch simply by touching it This is an optical-type switch (two beam axes) which allows you to start equipment simply by touching the sensing surface to interrupt the light beams. SW-11 Sensing surface Beam axes Light SW-1 To Touch From Push Reduces load on hands and fingers Provides a zero force, low impact, machine control solution. Prevents medical issues The switch reduces the possibility of medical problems that are associated with high impact push buttons, such as tendonitis or carpal tunnel syndrome. Reduction in false operation from dropped objects SW-11 The response time is set for a slight delay so that the switch will not respond a falling object, such as a dropped tool. The switch is designed so that it will operate when touched by hand, but false operation will rarely occur when something is dropped onto it. Dropped item Not detected Hand Detected

Optical Touch Switch SW-1 SERIES 688 A switch that pursues the prevention requirement for malfunctioning as required by ISO 13851 (JIS B 9712) two-hand control devices To Grip From Push Intended startup is possible s detection does not operate when a hand is just placed onto the unit. With a design that only detects when fingers are bent in and lightly grip onto the unit, an intended startup is possible. Safeguard prevents false operation saves the hassle of making an additional safeguard. In addition, with its ISO 13851 complying shape, even a knock on the elbow will not cause a false operation (light interruption). No false operation by wrist Experimental cone (ISO 13851) does not produce false operation on the experimental cone specified by ISO 13851. No false operation by elbow ø66 mm ø2.598 in 35 mm 1.378 in 15 mm 5.96 in No false operation by plastic sheet PHOTO PHOTO MEASURE Detection does not operate when a hand is only placed onto the unit. Equipped with external input indicators Two sets of external input indicators (two colors) are provided, so that they can be used as operation indicators for a variety of purposes. Detection only operates when fingers are bent in and lightly grip onto the unit. Application example When used as two-hand control devices Prevents false operation caused by dirt If the light is continuously interrupted for more than 1 sec. by dust, etc., the switch is disabled and the fault indicator (yellow) illuminates. Uses a long-life Photo-MOS relay Because a Photo-MOS relay is used for the output, a single unit can be configured without a specific output polarity. In addition, there is no need for periodic replacement of parts such as contact-type relays. Light SW-1 Application example SW-11: Turns off Setting object SW-11: Lights green Starting preparation complete SW-11: Lights orange Processing

689 Optical Touch Switch SW-1 SERIES ORDER GUIDE Light SW-1 Designation Appearance Model No. Power supply Output Optical touch switch With safeguard SW-11 Designation Model No. Description Mounting tool Sensing surface protective sheet for SW-11 SW-MT1 SW-PS1 SPECIFICATIONS 12 to 24V DC ±1 % Tool for tightening mounting nuts with a commercially-available wrench. (Refer to p.691) A transparent stick-on sheet that protects the sensing surface of SW-11 from dirt and scratches. 5 sheets per set Semiconductor Photo-MOS relay output 3 Sensing surface protective sheet for SW-11 Optical touch switch Designation With safeguard Item Model No. SW-11 Sensing method Thru-beam type photoelectric sensor (2 beam axes) Applicable standards CSA 22.2 No.14, CSA 22.2 No..8, ANSI/NFPA 79, UL 58, EN 6947-5-2 (EMC only) CE marking directive compliance EMC Directive, RoHS Directive Power supply 12 to 24 V DC ±1 % Ripple P-P 1 % or less Current consumption 1 ma or less (excluding external connection load) Semiconductor Photo-MOS relay output 3 Outputs Maximum load current: 1 ma Applied voltage: 3 V DC or less (between output and +V) Residual voltage: 1.5 V or less (at 1 ma of load current) Output operation SW-PS1 Output 1 : When an object is detected (beam is interrupted): OFF / When an object is not detected (beam is received): ON Output 2, 3 : When an object is detected (beam is interrupted): ON / When an object is not detected (beam is received): OFF Short-circuit protection Incorporated Response time 1 ms or less when an object is detected, 5 ms or less when an object is not detected Time-out function Switchable either effective or ineffective by short-circuiting terminals (disabled when short-circuited) to 1 V or 1 V to +V: Valid ( indicator lights up), 4 to 6 V or Open: Invalid ( indicator lights off) Power indicator (POWER) Green LED (lights up when the power is ON) Operation indicator (OPE.) Green LED (lights up when an object is detected) indicator 1 Green LED (lights up when external input 1 is valid) indicator 2 Orange LED (lights up when external input 2 is valid) Fault indicator (ULT) Yellow LED (blinks or lights up when fault occurs) Protection IP65 (IEC), TYPE 1 (UL 5) (excluding terminal part) Ambient temperature 25 to +5 C 13 to +122 F (No dew condensation or icing allowed), Storage: 3 to +7 C 22 to +158 F Ambient humidity 3 to 85 % RH, Storage: 3 to 85 % RH Ambient illuminance Incandescent light: 3, lx or less at the light-receiving face Voltage withstandability 1, V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 2 MΩ, or more, with 5 V DC megger between all supply terminals connected together and enclosure Vibration resistance 1 to 5 Hz frequency, 3 mm.118 in double amplitude in X, Y and Z directions for two hours each 1 to 15 Hz frequency,.75 mm.3 in double amplitude in X, Y and Z directions for two hours each Shock resistance 5 m/s 2 acceleration (5 G approx.) in X, Y and Z directions three times each Removable-type Connector 3.5 mm.138 in pitch, 2-level socket: 12 pins terminals Terminal part 3.5 mm.138 in pitch spring-cage terminals: 6 pins 2 (FMC1,5/6-ST-3,5GS manufactured by Phoenix Contact) Cable.2 to 1.5 mm 2 [including single wire or ferrule (sleeve)] Maximum cable length Up to 2 m 65.617 ft (for cable from.2 to.3 mm 2 ), Up to 1 m 328.84 ft (for cable from.3 to 1.5 mm 2 ) Material Enclosure: Polycarbonate, Polyester, O-ring: Silicone rubber, Mounting nut: PBT, Mounting packing: Silicone rubber Weight Net weight: 13 g approx., Gross weight: 2 g approx. Net weight: 15 g approx., Gross weight: 22 g approx. Indicators Environmental resistance Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 C +73.4 F.

Optical Touch Switch SW-1 SERIES 69 I/O CIRCUIT DIAGRAMS I/O circuit diagram If case of connecting output to Minus common Main circuit indicator 1 indicator 2 circuit 1 circuit 2 Internal circuit Terminal No. +V Switching terminal of time-out function (+V) Input of time-out function (IN) Output 1_1 Output 1_2 Output 2_1 Output 2_2 Output 3_1 Output 3_2 V 1 2 Users circuit Non-voltage contact or PNP open-collector transistor or + 12 to 24 V DC ±1 % Contact closed or transistor ON : Valid ( indicator lights up) Contact open or transistor OFF : Invalid ( indicator lights off) Terminal arrangement diagram If case of connecting output to Plus common Main circuit indicator 1 indicator 2 circuit 1 circuit 2 Internal circuit Terminal No. +V Switching terminal of time-out function (+V) Input of time-out function (IN) Output 1_1 Output 1_2 Output 2_1 Output 2_2 Output 3_1 Output 3_2 V 1 2 Users circuit Non-voltage contact or NPN open-collector transistor or + 12 to 24 V DC ±1 % Contact closed or transistor ON : Valid ( indicator lights up) Contact open or transistor OFF : Invalid ( indicator lights off) 1 2 3 4 5 6 7 8 9 1 11 12 Terminal No. Light SW-1

691 Optical Touch Switch SW-1 SERIES PRECAUTIONS FOR PROPER Refer to p.1595 for general precautions. Light Never use this product in a device for personnel protection. In case of using devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. Do not use this product as a device for emergency stop. This product is used to start up the machinery. Securing safety for the startup of machinery should be performed separately. When using the products for two-hand control, comply with the following contents. Select a model of a control device for two-hand control, based on results of risk assessment. Make sure to use a controller for two-hand control which complies with ISO 13851 (EN 574, JIS B 9712) For another requirements such as mounting of this product, or prevention of accidental actuation and of defeat etc., comply with ISO 13851 (EN 574, JIS B 9712) and ANSI B11.1, B11.9. Furthermore, comply with the regulations established by national or regional security committees (Occupational and Health Administration: OSHA, the European Standardization Committee, etc.) Mounting Fasten a mounting nut (accessory) from the reverse side of the mounting plate. (Note 1) The tightening torque should be 2 to 3 N m. Notes: 1) A mounting tool (SW-MT1) for fastening the mounting nut is available separately. The shape of fastening part of SW-MT1 is M1 nut. 2) Make sure to use the attached mounting packing, or waterproof property will be invalid. SW-11 Main body Mounting packing (Accessory) (Note 2) Mounting plate (Purchase separately.) Mounting nut (Accessory) Mounting tool SW-MT1 (Optional) Time-out function Unintended beam interrupted status caused by dirt on the sensing surface, etc. can be monitored. When beam interrupted status (sensing status) continues for 1 sec. or more, output 1 turns ON and output 2 and 3 turn OFF (output status is the same as non-sensing status.) This function can be invalid by short-circuiting between switching terminals of time-out function (terminal No. 7 and No. 8) as described below. Note: When time-out function is operated, the fault indicator (yellow) lights up. In this case, once beam is received, the fault indicator lights off and the sensor returns to normal operation. <Time chart (In case time-out function works)> Nonsensing 1 sec. Sensing status or more Sensing ON OUT 1 OFF 7 8 ON OUT 2 OFF ON OUT 3 OFF Short-circuit between time-out Lights up function switching terminals Fault indicator Lights off Others This device has been developed / produced for industrial use only. When the power of the thru-beam type photoelectric sensor inside the main body turns on in beam interrupted status, output 1 turns ON and output 2 and 3 turn OFF, then the fault indicator (yellow) lights up. In this case, once beam is received, the fault indicator lights off and the sensor returns to normal operation. Use a power supply unit conforming to the EMC Directive and the Low Voltage Directive. (Only for use in Europe) Use a power supply unit conforming to Class 2. (Only for use in the North America) Use a power supply unit with an output holding time of 2 ms or more. Do not use during the initial transient time (3 ms approx.) after the power supply is switched on. SW-1

Optical Touch Switch SW-1 SERIES 692 DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. SW-11 indicator 1 indicator 2 69.3 2.728 64.8 2.551 52.4 2.63 15.591 indicator 2 3.118 max. 1 (.39) Mounting nut Panel cut-out dimensions <When mounting with a resin plate> +.5 ø3.5 ø1.21 +.2 +.2 4.8.189 +.8 +.5 33 1.299 +.2 ø4 ø1.575 16.1 ( ) Fault indicator (Yellow) Operation indicator indicator 2 indicator 1 11.8 ( ).465 58.4 2.299 8 3.15 55 2.165 52.4 2.63 Power indicator 7.276 8 3.15 18.2.717 Operation indicator indicator 2 indicator 1 2.6 75 4.5.12 2.953 ( 1.594) 64.8 55.8 2.551 2.197 (15.6.614) 1.394 (29.3 1.154).634 <When mounting with a metal plate> +.2 4.8.189+.8 ø3.5+.5 ø1.21+.2 R4 ±.1 R.157 ±.4 +.5 18.4.724+.2 +.5 33 +.5 1.2 1.299+.2.42 +.2 R4 ±.1 R.157 ±.4 (21.7.854) Diagram without mounting nuts installed M3 1.5.59 Note: The panel thickness should be 3 mm.118 in or less. Optical touch switch 14.551 indicator 2 indicator 1 indicator 2 3.118 max. 1 (.39) Mounting nut indicator 2 indicator 1 Fault indicator (Yellow) ø4 ø1.575 Operation indicator 1.394 16.1 (.634) Panel cut-out dimensions <When mounting with a resin plate> +.2 4.8.189 +.8 33.5 ( 1.319) 18.4 (.724) 8 3.15 11.8 (.465) 6 ( 2.362) 8 3.15 indicator 2 indicator 1 4.9 75 1.61 2.953 14.3 16.1 4.16.634 (29.3 1.154) 21.7 (.854) ( ) <When mounting with a metal plate> +.2 4.8.189+.8 Power indicator Operation indicator Optical touch switch Diagram without mounting nuts installed 14 M3 1.5.59.551 Light SW-1 +.5 ø3.5 ø1.21 +.2 +.5 33 1.299 +.2 ø3.5+.5 ø1.21+.2 R4 ±.1 R.157 ±.4 +.5 18.4.724+.2 +.5 33 +.5 1.2 1.299+.2.42 +.2 R4 ±.1 R.157 ±.4 Note: The panel thickness should be 3 mm.118 in or less.