Excel 10 Q7750A ZONE MANAGER

Similar documents
4100U City and Relay Cards Installation Instructions

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

/9308 External Battery Chargers Installation Instructions

INSTALLATION INSTRUCTIONS

KT-100 Door Controller

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

Booster Power Supply Manual

Model 17A00 Expansion Enclosure

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

Public Safety DAS Annunciator Panel

MODEL B2 INSTALLATION MANUAL

Long Range Radio Alarm Transmitter

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

Addressable NAC Output Module D327A

ANNUNCIATOR FIXED MODULE

SC-6 Six Supervised Control Module

7800 SERIES RM7888A Relay Module

UNC100 Integra Manual

Installation Guide for models:

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

Installation Guide for models:

Control Relay Modules

MANUAL RESET ALARM RELEASE

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

21-light Remote Annunciator. Owner s Manual

7800 SERIES RM7888A Relay Module

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

HRX Technical Manual. Version 1.2

IDP-Zone-6 Six Zone Interface Module

Long Range Radio Alarm Transmitter

7800 SERIES EC7885A/RM7885A Relay Module

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

5000 INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Greentrol Automation, Inc.

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

Remote NAC Power Supply D7038

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

/ XPS Interconnection Diagrams

DOOR MONITORING/DURESS SYSTEM

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

InBio X60 Series Access Control Panel User Manual

/5121/5122 TrueAlert Power Supply Installation Instructions

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

MANUAL RESET ALARM RELEASE

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

MMF Six Zone Interface Module

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

RELEASE DEVICE CONTROLS

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

Sensor Interface Module Installation/Operation Instructions

RS485 MODBUS Module 8AI

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

20 Light Remote Annunciator

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

HRX3000. Technical Manual

INSTALLATION GUIDE XTLN-WIFI PANEL

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

FireNET Plus Wiring Instructions

CR Series Command Relays

AL800ULADA. NAC Power Extender. Installation Guide

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

AL600ULADA. NAC Power Extender. Installation Guide

7800 SERIES EC7823/RM7823 Relay Module

SAFETY INFORMATION AND WARNINGS

Metasys System Extended Architecture Smoke Control UL 864 UUKL Compliance

Installation and Maintenance Manual IM 1038

Fire Control/Communicator

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

Series. Access Power Controllers. Installation Guide

Remote Booster Power Supplies

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Transcription:

Excel 0 Q7750A ZONE MANAGER INSTALLATION INSTRUCTIONS WARNING Warning: This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the Instructions Manual, may cause interference with radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 5 or FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case, users at their own expense will be required to take whatever measures may be required to correct the interference. Any unauthorized modification of this equipment may result in the revocation of the owner s authority to continue its operation. GENERAL The Q7750A Zone Manager is a controller that provides all Excel 5000 controller functions and also provides communication interface between an Excel 0 controller Echelon LONWORKS (E-Bus) subsystem and an Excel 5000 C-Bus system. The Q7750A Zone Manager can also be used as part of a smoke control system monitoring and control for monitor and control of fire (UL 864) and general purpose signaling (UL 07). In UL 07 applications, the product can be used as a type SM (Self-Monitored) system. This controller can be used for smoke control applications when used in conjunction with a UL listed fire alarm control panel (FACP) and UL listed fire fighters smoke control station (FSCS). BEFORE INSTALLATION These Installation Instructions are applicable for the Q7750A Excel 0 Zone Manager000-series-Free Topology E-Bus transceiver, including revision software. Only trained technicians are allowed to work on the installation of the Q7750A hardware and to change the EPROMs or the Submodule within the hardware. The Q7750A Excel 0 Zone Manager is fully assembled and tested at the Honeywell Factory Parts Checklist Q7750A Excel 0 Zone Manager with mounting base. (The operating system EPROMs are installed internally.) Ferrite ring (supplied with 000-series devices). Form no. 95-7509, Excel 0 Q7750A Installation Instructions. Options: XD505A (standard) or XD508 ( megabit baud rate) C-Bus communications submodule or XDM506 modem submodule. Not included with the Excel 0 Q7750A order, but needed for every Excel 0 Q7750A application: 4 Vac power source for the Q7750A Excel 0 Zone Manager. PC with Microsoft Windows, CARE software (for 000-series) or E-Vision software (for 000-series) and Protection Block. Communications cable for the PC to Q7750A Excel 0 Zone Manager; the XW565 6 ft 6 in. (5 m); the XW566 49 ft 6 in. (5 m); or the XW567 8 ft 3 in. (.5 m). NOTES: Each Q7750A Excel 0 Zone Manager requires 4 Vac power. The following information is given for US applications: For a standalone interface device, use the 4 Vac power from a 5/4 Vac A, 50 VA, UL listed, Class II Transformer (450787-007). When conditioned power is required, use a 4 Vac 450787-00 Power Module (5 Vac). For multiple interface devices, use the 4 Vac power from a 5/4 Vac 6A, 50 VA, UL listed, Transformer (see NOTES in WIRING Section when using a transformer greater than 00 VA). When conditioned power is required, use a 4 Vac 450787-00, or -003 Power Module (5 Vac). (When using any of the 450787 Power Modules, use 4507063-003 Cable Assembly to connect the 4 Vac power to the mounting base of the interface device.) 95-7509 9

Power can be provided optionally by installing a fuse and an On/Off switch on the primary side of the 4 Vac transformer. 9-/6 (46) Fig.. Excel 0 Zone Manager Dimensions. INSTALLATION 7-9/6 (9) -/3 (66) M007 Unpack the Q7750A Excel 0 Zone Manager. Report any damage to a Honeywell Representative. General Mounting The cabinet/enclosure must be attached to a solid surface (masonry or concrete slab) or to the wall framing members. The cabinet attachment must be securely anchored to the wall and be designed to hold at least four times the weight of a full-loaded cabinet. Enclosure mounting must be in accordance with all applicable codes. The maximum weight of the enclosure and its contents must not exceed 5 lbs (.7 kg). Unless otherwise noted, the top of the cabinet is positioned at the top of the drawings in this document. The cabinet must be mounted in the position shown. Drywall. Use at least four mounting points; at least two of the enclosure mounting holes must be aligned over the center of the stud.. Use a No. 8 x -/ in. (3 mm) minimum length sheet metal screw with flat washer and lock washer into the center of the stub. 3. Use /8 in. (3 mm) diameter (minimum) toggle bolt to secure the other side into the drywall for the mounting holes not centered over a stud. NOTES: Wall surface material must be a minimum of 5/8 in. (6 mm) thick. If not, the area between the studs must be reinforced with 3/4 in. (9 mm) minimum thickness wood board or material of equal or greater strength. /8 in. (3 mm) diameter toggle bolts are used for all mounting locations not centered into a stud. Concrete/Masonry. Establish four mounting points (minimum) in the masonry aligned with the cabinet mounting holes at the four corners of the enclosure.. Screw the cabinet to the wall using 3/6 in. (5 mm) diameter x -/4 in. (3 mm) long (minimum) hex washer head masonry anchors (ITW Ramset/Red Head Tapcon or equal) per manufacturer s recommendations. IMPORTANT Alternative mounting methods of equal or greater strength are allowed, provided they also meet or exceed all local code requirements. Install Mounting Base To install the mounting base:. Remove the base from the Q7750A Excel 0 Zone Manager housing.. Remove the front cover of the Q7750A Excel 0 Zone Manager by pressing in and down on the plastic ridges located on the front and center of the device (See Fig. ). Q7750A EXCEL 0 ZONE MANAGER M8549 FRONT COVER Fig.. Open Cover. 3. Remove the special metal tool located near the bottom of the housing (Refer to Fig. 3). 4. Separate the housing from the mounting base (Refer to Fig. 4). 95-7509 9

M8555 Fig. 3. Take Out Tool. M494 Fig. 4. Remove Brass Screw, Loosen, remove Q7750A Excel 0 Zone Manager Housing from Mounting Base. NOTES: There is a rubber grommet under the device housing that holds the brass screw in place. Where Electro-Magnetic Interference (noise) emissions must be considered, install the Q7750A Excel 0 Zone Manager in a ring cabinet that is earth grounded. There are two ways to install the mounting base: On standard EN 50 0 DIN rail, -3/8 by 9/3 in. (35 by 7.5 mm), which is fastened with screws to a vertical surface. (Type of screws used such as sheet metal, self-tapping or thread forming and the screw lengths are determined by the type of mounting material at the job site.) By fastening the mounting base, with screws, directly to a vertical surface. DIN RAIL MINIMUM OF 6 IN. (55 MM) 4-7/8 (4) M8556 Fig. 5. Attach DIN Rails. 3 95-7509 9

DIN Rail. Attach two DIN rails, 6 in. (55 mm) minimum in length, with appropriate screws for the mounting surface.. Space the two DIN rails 4-7/8 in. (4 mm) apart, measured from the top of each DIN Rail, while keeping them both horizontal and parallel (Refer to Fig. 5). 3. Loosen the metal screw on the bottom of the mounting base and hang the mounting base on the DIN rails using the plastic flanges located on the back of the mounting base (Refer to Fig. 6) To mount the base using screws:. Orient the mounting base vertically on the mounting surface.. Use the three screw holes (two located at the bottom corners of the base and one at the top center) and mark the positions for the three No. 8 (4.0 mm) mounting screws. 3. Attach the base to the surface with the appropriate mounting screws (See Fig. 8). M8568 Fig. 6. Hang Mounting Base. M853 4. Slide the metal screw up against the lower flange of the bottom DIN rail and tighten the screw (See Fig. 7). NOTE: Fig. 8. Attach Mounting Base with Screws. Wiring must enter the mounting base from the bottom. To prepare wire access holes:. Break off one or two of the plastic tabs just left of the metal screw on the mounting base for wiring access and routing to the lower left terminal block (See Fig. 9). M8567A M857A Fig. 7. Position and Secure Mounting Base. Fig. 9. Break off Plastic Tabs for Wiring Access to Lower Left Terminal Block. 95-7509 9 4

WIRING NOTES: All wiring must comply with applicable electrical codes and ordinances. Refer to job drawings or manufacturer s drawings for details. All wiring terminals are located on the inside of the front cover. Pass all wires through the appropriate holes from the broken plastic tabs (Refer to Fig. 9). Break off plastic tabs for wiring access to lower left terminal block. Route wires and tie-wrap (Refer to Fig. ). All wiring to the Q7750A is supervised, except as noted. All circuits are power limited except for AC power circuits, relay contacts and other circuits as noted. All field wiring terminals accept 4 AWG to 4 AWG (0.5 sq mm to sq mm) conductors, except as noted. C-Bus Wiring. Wire the C-Bus using cable (See Table ).. Connect the C-Bus cable by attaching the shield to terminal 8, the positive lead to terminal 6 and the negative lead to terminal 7 according to job drawings (Refer to Fig. 0). Power Wiring Input Power: 4 Vac, 50/60 Hz.. Wire 4 Vac power using the heaviest gauge UL level IV or plenum rated UL level IV wire available, up to 4 AWG ( sq mm) with a minimum of 8 AWG ( sq mm) wire. For nonplenum, open areas, run cables exposed (or in conduit if required; see the following NOTES). NOTES: The Q7750A Excel 0 Zone Manager must have a dedicated transformer/power source. Do not power any accessories with the Q7750A Excel 0 Zone Manager transformer/power source. Keep the transformer/power source as close as possible to the Q7750A Excel 0 Zone Manager so the power wiring will be as short as possible; the maximum length is 6 ft. 6 in. ( m). (US only) When using a 4 Vac transformer larger than 00 VA, Class II power requirements will be exceeded and the power wiring must be enclosed in conduit. CAUTION Electrical Shock Hazard. Power Supply can shock. Make certain no line power is applied to the transformer/power source to prevent device from being attached with power on. Mounting base power must remain off until installation and wiring is checked by a control system representative.. Connect 4 Vac secondary side of the transformer/ power source to terminals and on the mounting base according to job drawings (Refer to Fig. 0). E-Bus Wiring. Wire the E-Bus using Level IV AWG (Belden part number 9D050) or plenum-rated level IV AWG (Belden part number 9H0504) nonshielded, twisted pair, solid conductor wire, as the recommended wire. NOTE: When possible, use Honeywell AK378, AK378, AK379, or AK379 cable (US part numbers).. Connect the E-Bus wire by attaching one lead to terminal 5 and the other lead to terminal 6 according to job drawings (Refer to Fig. 9). IMPORTANT For 000-series devices the E-Bus must be wound one turn through a ferrite cylinder (supplied with the device) a maximum of 7/8 in. (0 mm) from the housing (See Fig. 0). NOTES: The E-Bus is insensitive to polarity, eliminating installation errors due to miswiring. Table. C-Bus Cable Types. Maximum Baud Rate Cable Type Description Remarks 76.8K JY (St) Y xx0.8 Shielded, twisted pair AK370 Unshielded, twisted pair U.S. only AK3740A Shielded U.S. only 9.6K Belden 984 Twisted pair Belden 984 Shielded U.S. only AK370 Unshielded, twisted pair U.S. only AK3740A Shielded U.S. only To minimize EMI noise, do not run Triac output wires in the same conduit as the input wires or the E-Bus communications loop. Unswitched 4 Vac power wiring can be run in the same conduit as the E-Bus cable. 3. For a 000-series device there are internal termination circuits for both a singly-terminated network topology (jumper between terminals 4 and 5 and between terminals 6 and 7) and for a doubly-terminated bus topology (jumper between terminals 3 and 5 and between terminals 6 and 8) (See Fig. ). 5 95-7509 9

4 VAC 4 VAC 4 VAC INTERNAL TERMINATION NETWORK INTERNAL TERMINATION NETWORK 3 4 5 6 7 8 9 0 3 4 5 6 7 8 EOL E-BUS E-BUS EOL C-BUS + C-BUS 9 0 3 4 5 6 7 8 RTS CTS DSR SIGNAL GROUND DTR DCD RI RXD TXD MODEM SHIELD DOUBLY-TERMINATED EOL SINGLY-TERMINATED EOL DOUBLY-TERMINATED EOL SINGLY-TERMINATED EOL 3 4 5 6 7 8 9 0 3 4 5 6 7 8 E-BUS E-BUS SHIELD FAST BLOW AMP FUSE C-BUS E-BUS FIELD INSTALLED JUMPERS 5/4 VAC 50 VA TRANSFORMER 450787 POWER MODULE POWER MODULE SOWN FOR U.S. APPLICATIONS ONLY. ON/OFF POWER SWITCH (OPTIONAL) 5 VAC 3 E-BUS FIELD INSTALLED JUMPERS SHOWN FOR SINGLY-TERMINATED NETWORKS. JUMPERS FOR DEVICES WITH DOUBLY-TERMINATED NETWORKS ARE PLACED BETWEEN TERMINALS 3 AND 5 AND BETWEEN TERMINALS 6 AND 8 (SHOWN DOTTED IN SCHEMATIC). FERRIT RING LOCATED 7/8 IN. (0 MM) MAXIMUM FROM HOUSING. M009 3 NOT SUPERVISED. M5577 Fig. 0. Wiring Connections (000-Series E-Bus Details). 4. If a XDM506 modem submodule is being used, attach the modem wiring to the appropriate terminals (9 through 8) on the mounting base (See Figures 0 and ). Fig.. 000-Series E-Bus Details. After wiring is routed, insert the tie-wraps into the holes located near the center of the mounting base (Refer to Fig. ). Route wire and tie-wrap. 95-7509 9 6

a SIG=Signal, DC=Direct Current. b All voltages are FWR. Table. Connector Terminal Specifications. Maximum Connector Signal Voltage Maximum Maximum Maximum Line Terminal Type Input/Output Type a Voltage b Current Frequency Impedance B-Port B Output TXD ±V ±8 ma 9600 baud 00 ohms B Input RXD ±0 ma GND C-Bus C+ Input/Output SIG ±5V ma/80 ma 9.6 baud 00 ohms C- 3S Shield E-Bus E+ Input/Output SIG ±5V ma.5 mbs E- 3S Shield Modem 9 RTS Output DC ±V ±8 ma 00 ohms 0 CTS Input ± ma DSR 00 ohms GND 3 DTR ±V ± ma 00 ohms 4 DCD 5 RI 6 RXD SIG 7 TXD 8 M Shield Install Electronic Components CAUTION Equipment Damage Hazard Excessive static can burn out equipment. Observe proper anti-static material handling practices when installing or servicing PC parts and related components. Observe proper equipment and body grounding practices. Complete the Installation. Before mounting the Q7750A Zone Manager, turn over the device housing and remove the Phillips screw located at the bottom (remove brass screw/grommet, battery and shipping tab).. Separate the two parts of the device housing (Refer to Fig. 3). NOTE: There is a brass standoff located on the bottom between the circuit board and the top of the device housing. (This connects the shielding between the two parts of the device housing.) Discharge static electricity from your body before handling parts. 7 95-7509 9

TIE-WRAP M8573A Fig.. Route Wire and Tie-Wrap. CIRCUIT BOARD DIP SWITCH LOCATION BRASS STANDOFF M8569 Fig. 3. Separate Two Parts of Device Housing (DIP Switch for Future use). 95-7509 9 8

3. Attach the XD505A or the XD508 C-Bus communications submodule or the XDM506 modem submodule, (ordered with the Q7750A) to the male and female connectors on the device circuit board. CAUTION Equipment Damage Hazard. Connection misalignment can cause damage to the C-Bus submodule. C-Bus submodule connectors are not keyed; make sure that the male and female connections are not misaligned. 4. Press firmly down on the submodule (See Fig. 4). 5. Reassemble the device housing by connecting the two parts of the device housing and replacing the brass screw/grommet, battery and shipping tab. 6. Verify the integrity of all the mounting base wiring. M8570 Fig. 5. Attach Device Housing to Mounting Base. Install Battery Included with the device is a 3V Lithium battery, CR / AA, VARTA number 67 or equivalent. This battery, when new, provides one month backup of RAM and the Real Time Clock. NOTES: When shipped from the factory, the battery has a shipping tab between the battery positive (+) terminal and the device terminal. Remove the shipping tab during commissioning of the device. (Check and observe the polarity marked on the housing and the battery; reverse if necessary) (See Fig. 6). When the battery is removed during a loss of input power, RAM data is lost and the device must be re-downloaded. SUBMODULE M8574 Fig. 4. Attach Submodule, Reassemble Device Housing. Secure Housing Assembly to Mounting Base. After all mounting base wiring is checked, carefully align the device housing over the mounting base.. Push firmly on the housing device to secure it to the mounting base. 3. Tighten the brass screw (See Fig. 5). M8565 Fig. 6. Remove Battery Shipping Tab During Device Commissioning. 9 95-7509 9

CHECKOUT Step. Wiring Connections Inspect all wiring connections at the Q7750A terminals and verify compliance with job drawings. If any wiring changes are required, first be sure to remove power from the controller before starting work. Pay particular attention to: 4 Vac power connections. Verify that when there are multiple Q7750A Excel 0 Zone Managers, each one has a dedicated transformer/power source, with the transformer secondary connected to terminals and on the mounting base, according to job drawings (Refer to Figures 0 and ). E-Bus wires. Be sure that the E-Bus wires are attached to terminals 5 and 6 according to job drawings. If the Q7750A device is located at one end of the E-Bus network, check to determine if the termination network was activated by placing two wires (optional jumpers) between the following terminal pairs (Refer to Fig. ): 4,5 and 6,7 (singly-terminated network) 3,5 and 6,8 (doubly-terminated network) C-Bus shield. Be sure that the C-Bus shield is attached to terminal 8, the positive lead to terminal 6, and the negative lead to terminal 7 according to job drawings (Refer to Figures 0 and ). Check to see that the ferrite ring is in place on the E-Bus (Refer to Fig. ). All wiring must comply with applicable electrical codes and ordinances. Refer to job or manufacturer drawings for details.. MOUNTING BASE 5V CONTR. B-PORT SEND B-PORT RECEIVE B-PORT CONNECTION RESET BUTTON ERROR E-BUS OPERATION C-BUS RECEIVE C-BUS SEND BATTERY EXCEL 0 ZONE MANAGER ASSEMBLY (SHOWN WITHOUT FRONT COVER) M8560 Fig. 7. Q7750A Excel 0 Zone Manager LED Locations. Table 3. Q7750A Excel 0 Zone Manager LED Status Information. LED Explanation Color LED Function if On LED Function if Off 5V (POWER) Green Power O.n Power Off. Contr. (RUN) Green Software is running, Watchdog locked, software not working. watchdog is triggered. 3 B-PORT (send) Yellow Q7750A sends data No communication. on RS3 port a. 4 B-PORT (receive) Yellow Data is sent to No communication. Q7750A on the RS3 port a. 5 C-Bus (send) Yellow Q7750A sends data No data sent on the C-Bus. on the C-Bus a. 6 C-Bus (receive) Yellow Q7750A receives No data received from the C-Bus. data on the C-Bus a. 7 E-Bus Yellow E-Bus network No E-Bus network activity. activity a (see NOTE). 8 Error Red Blinking: not Valid configuration. configured, application loaded. On: no configured, no application. a LEDs 3 through 7 flicker with the frequency of data being transmitted or received (See NOTE). 95-7509 9 0

Step. Initial Power Up Apply power to the Q7750A. When the Q7750A receives power, the LEDs should appear in normal (uncommissioned and not downloaded) condition (Refer to Table ). NOTE: LED 7 is used to display E-Bus network activity. In 000-series devices it flickers with data being transmitted or received, but in 000-series devices it flickers only with data being received. If the status is not correct, push the reset button. Verify that the LED status is correct before proceeding. IMPORTANT The CPU reset button deletes the application program in the CPU (stored in RAM). If the reset button is pushed when the CPU contains an application, the device must be re-downloaded. Step 3. Commissioning The Zone Manager CPU can be commissioned (given a C-Bus address) using an operator terminal such as the XI58 (on the PC that has the XI584 software and/or CARE installed). This operation is performed the same as for other C-Bus controllers. The following steps describe the most common procedure using the PC to commission the CPU just before downloading from the XI584. As for other C-Bus controllers, commissioning is required only after an initial power-up or if the CPU reset button was pushed. The following steps assume the Zone Manager Plant and Controller are configured in CARE (see Data File Setup section):. Connect the PC COM port to the Zone Manager B-port using the XW565 (or XW566) prefabricated cable.. Start XI584. Sign on and run XI58. Assign the controller number using the procedure for C-Bus devices (see the XI584 User's Guide, form 74-3555). 3. Select Continue again, and select Request Download. The operator terminal should then display. Please Execute Download. 4. Select Utilities and drop down to the item File Transfer/Download. Click on All and initiate the Download. Commissioning is complete. The B-port Transmit and B-port Receive LEDs on the Zone Manager should start blinking rapidly, indicating communication between the PC and the Zone Manager. Any Download errors or connecting problems appear in the Download Results list box. A loss of communication with the B-port during downloading generates an alarm after three minutes. Press Enter and try again to download. If there is trouble establishing communication between the PC and the Zone Manager, check the following items: XW565 cable connections. XW565 cable connection is to the same PC COM port as selected in the CARE Download System Settings menu. IMPORTANT Carefully watch all C-Bus alarm activity following a download. Follow up as necessary on all problem alarms. Fig. 8. Connect Operating Device. Close Cover Put the device cover back on (See Fig. 9). DATA FILE SETUP Fig. 9. Close Cover. M8558 M8559 Generate the CARE data file for the Zone Manager/RIO/Excel 0 VAV controllers. This data file has a mix of hardware points for the necessary inputs and outputs to control fans, dampers and other equipment. In addition to the inputs and outputs, a custom control program is written to control the outputs per the sequence. It also resets the program once the data from the operator interface indicates a normal condition for the new dedicated smoke control equipment. Wire conditions must be programmed to provide annunciation of trouble conditions. Also required for a dedicated application is a weekly time program to test control points, fans and dampers by exercising the equipment and verifying feedback automatically during low building activity periods. 95-7509 9

PANEL RESET When in Smoke Control Mode, panel reset is accomplished by resetting the initiating panel contact circuit or by the separate initiating/reset switch on the FSCS panel. Field Parameters Minimum/Maximum Rating W775B,D,F,H,RIO Triac Outputs: 4 Vac at 550 ma, steady state, pilot duty. Device:.4A maximum at 5V. Digital Inputs: 4.8± 0.8 Vdc, 9 ma ± ma. E-Bus: Not readable. A max. of 5 triac outputs may be on at one time. 95-7509 9

SMOKE CONTROL CONFIGURATION 6 6 SMOKE CONTROL CONFIURATION 9 UL LISTED FIRE ALARM CONTROL UNIT ALARM INPUT DI RIO W776 8 5 LON BUS Q7750A XL 0 DO 4 SUPPLY LON VAV FAN BUS 5 ZONE MANAGER 4 W775 B,D,F,H DO AIRFLOW SENSOR SUPPLY FAN 4 5 STATUS DO AO DAMPER 3 4505068 AUDIBLE ANNUNCIATOR FIREFIGHTERS SMOKE CONTROL PANEL (FSCS) STATUS CONTROL XL 0 VAV Q7750A RIO 7 0 3 3 4 5 6 7 8 9 0 3 4 5 LOCATE AND CONFIGURE PER NFPA 9A. UL LISTED ANNUNCIATOR/FSCS PANEL SWITCHES HAVE A MIN RATING OF 4V, /0 AMP AND LAMPS/LEDS HAVE A RATING OF 4V, LIMITED TO 50 ma. LOCATE WITHIN SAME ROOM AND WITHIN 0 FT IN CONDUIT OF RIO. LOCATE TO MINIMIZE CONTROL WIRING AND PIPING. AVOID RUNNING WIRES OR PIPING THROUGH AREAS THAT HAVE A HIGH FIRE RISK. LOCATE PER UL 555S. LOCATE SEPARATE FROM AND BELOW ALL BUILDING EXHAUST FANS AND UPSTREAM FROM ANY PREVAILING WINDS. EXHAUST TO OUTSIDE OF BUILDING. FREEZE CONTROL SENSING LIMIT MUST BE SET LESS THAN 3 F (0 C) WHEN IN SMOKE CONTROL MODE. SMOKE CONFIGURATION IS ONLY VALID WITH THE EXCEL 0 VAV AND EXCEL 0 REMOTE I/O THAT HAVE UUKL LISTING. UUKL LISTED EXCEL 0 CONTROLLERS ARE W775B00, W775D06, W775F0, W775H05 AND W776A00. LOCATE UL LISTED DAMPER PRESSURE/POSITION INDICATOR PER DAMPER INSTALLATION INSTRUCTIONS. SMOKE CONTROL MUST BE INITIATED BY A LISTED FIRE ALARM CONTROL UNIT OR IN ZONE AUTOMATIC ALARM DEVICES AND NOT DEVICES LOCATED OUTSIDE OF THE SMOKE CONTROL ZONE. INTERCONNECTING WIRING MUST BE WITHIN 0 FT (6M) AND IN CONDUIT. REFER TO NFPA 9A AND UL 864. VERIFY AC VOLTAGE SOURCE CONNECTED TO INSIDE OF MAIN LINE VOLTAGE TERMINAL BLOCK IS FROM A UL 48 LISTED UNINTERRUPTIBLE POWER SUPPLY. THE MAIN LINE VOLTAGE TERMINAL BLOCK MAXIMUM CURRENT DRAW IS 0.5 AMPS. USE 4504-0 AC TRANSIENT PROTECTION. ALL EXTERNAL FIELD WIRING MUST BE LIMITED TO 377 FT (999M) AND BE TERMINATED TO 4506944-00 TRANSIENT PROTECTOR (35V, 90 ma MAX.) EXCEPT C-BUS FIELD WIRING COMMUNICATING AT MHZ WHICH USES 4504-00 TRANSIENT PROTECTOR (9V, 500 ma) WHEN FIELD WIRING LEAVES THE ZONE. REFER TO JOB DRAWING FOR DEVICE INSTALLATION. USE 450787-00 AND -007 CLASS II POWER SUPPLIES, MAX. LOADING 00 VA. INSTALL IN SIGNAL SYSTEM ENCLOSURE CABINET. REFER TO ZONE MANAGER INSTALLATION SECTION FOR LON BUS (E-BUS) CONNECTIONS AND DEVICE INSTALLATION. 6 PER NFPA 9A THIS EQUIPMENT IS UTILIZED AS NON-DEDICATED SMOKE CONTROL EQUIPMENT. STATUS OF AIRFLOW CONTROL MUST BE PROVIDED VIA THE AIRFLOW SENSOR INPUT. M5400 Fig. 0. Smoke Control Configuration. 3 95-7509 9

POWER LIMITED POWER LIMITED 450787-00 THROUGH -003 POWER MODULE ACCESSORY 4V AC OUTPUT (RATED A) MUST BE WIRED IN ACCORDANCE WITH NFPA 70, ARTICLE 75 WHEN ROUTED WITHIN THE CABINET OR ADJACENT CABINETS AND ALSO FOR EXTERNAL FIELD WIRING. 4 ZM, R0 OR EXCEL 0 450787-00 OR -007 CONTROL POWER MODULE 4VAC OUTPUT IS INHERENTLY POWER LIMITED. THUS, ALL SOURCED POWER FROM THE EXCEL ZONE MANAGER, RI0, EXCEL 0 PANEL MOUNTED DEVICES ARE POWER LIMITED. ALL FIELD WIRING FROM THESE CONTROLLERS MEET NFPA 70, ARTICLE 75 POWER LIMITED CLASS II REQUIREMENTS. 0 VAC ZM, R0 OR EXCEL 0 6944 6944 6944 CONTROL 4VAC 450787-00 OR -007 DIGITAL OUTPUT RELAY POWER LIMITED ACCESSORY 4VAC 450787-007 6944 NON POWER LIMITED NON POWER LIMITED 3 4 IF A SEPARATE AUXILIARY "POWER LIMITED" 4V AC POWER SOURCE IS REQUIRED, USE A CONTROL POWER MODULE (450787-00 OR -007). DEVICES MUST BE INSTALLED IN AREAS AS SHOWN. ALL CABLE MUST BE ROUTED AS SHOWN. ALL INTERNAL POWER LIMITED WIRING MUST BE SEPARATED BY /4 IN. (6MM) OR BARRIER FROM NON-POWER LIMITED WIRE. EXCESS WIRING MUST BE CUT, TRIMMED AND DRESSED PROPERLY TO ENSURE PROPER CLEARENCES ARE MAINTAINED. NON POWER LIMITED M5578 Fig.. Typical Power Limited Circuit for Excel ZM, RIO, or Excel 0 Panel Mounted Devices. 95-7509 9 4

Step 4. Troubleshooting. Problem Description Solution 5V (Power) LED not on. No power to the Zone Manager. Apply power or verify the power wiring (voltage must be 0-30V), check fuses and output from power module or transformer number. Run LED is on. Zone Manager not operating. Software failure, do the following: Power the Zone Manager down, then up. Push the CPU reset button. If the motherboard EPROM has been removed, it may have been incorrectly re-installed. Commission the Zone Manager. C-Bus Transmit LED not flashing, C-Bus Receive LED not flashing. C-Bus Transmit LED not flashing, C-Bus Receive LED not flashing. C-Bus Transmit LED not flashing, C-Bus Receive LED not flashing. B-port Transmit LED not flashing, B-port Receive LED not flashing. E-Bus LED not flashing. E-Bus LED flashing. No C-Bus connection or no other C-Bus devices active on the bus. Zone Manager transmitting on the C-Bus, but not receiving. Zone Manager receiving on the C-Bus, but not transmitting. These only flash when an operator interface is communicating with the B-port. No E-Bus connection or no devices active on the E-Bus. Zone Manager transmitting or receiving on the E-Bus, but other devices on the E-Bus not receiving. Disassemble the Zone Manager and check the C-Bus communication daughterboard (XD 505, XD 508) mounted on the Zone Manager motherboard and reseat it. Verify the C-Bus wiring terminations, polarity. Disassemble the Zone Manager and check the C-Bus communication daughterboard (XD 505, XD 508) mounted on the Zone Manager motherboard and reseat it. Verify the C-Bus wiring terminations, polarity. Commission the Zone Manager. Verify C-Bus wiring terminations, polarity. Cycle power. Reconnect the operator interface. Try the operator interface on another controller. Disassemble the Zone Manager and verify the E-Bus wiring. Verify E-Bus wiring. Commission the Zone Manager. Error LED on. CPU hardware/firmware failure. Do the following: Power the Zone Manager down, then up. Push the CPU reset button. If the motherboard EPROM has been removed, it may have been incorrectly re-installed. Commission the Zone Manager. Batter Low message on an XBS, XI58, or XI584 Operator Terminal. Internal test of 3V lithium battery shows low power, possible failure. Remove and test the battery by putting a 5K ohm (0.4 watt, 5%) resistor across the positive and negative poles. If the voltage is less than.5v, replace the battery. Replace with a lithium 3V 00 ma hour, CR / AA, VARTA 67 or equivalent. OPERATION The Q7750A controllers have LED indicators that are used to show controller activity. Their function is identified on the controller nomenclature. Maintenance Procedures The system must be maintained in accordance with the system documentation and procedures and practices contained in applicable NFPA and UL standards. The internal memory in this series of controllers is supported by a Varta 67 CR / AA 3V lithium battery (not rechargeable). When the battery requires replacement, a low battery condition is indicated on the controller and sent to the MMI and central monitoring station. Replace when needed with the same battery type. For service, contact your local Honeywell Home & Building Control office as listed in the phone book, or contact a regional office as shown at the end of this document. 5 95-7509 9

Echelon and LONWORKS are registered trademark of Echelon Corporation. Excel 5000 is a trademark of Honeywell International Inc. Microsoft Windows is a trademark of Microsoft Corporation. Tapcon is a trademark of Illinois Tools Works Inc. Corporation. Varta is a trademark of VARTA AKTEINGESELLSCHAFT CORPORATION. Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 554 Toronto, Ontario MV 4Z9 www.honeywell.com/buildingsolutions U.S. Registered Trademark 00 Honeywell International Inc. 95-7509 9 J.I. Rev. 07-0