EXHAUSTO Inc in North America In Atlanta since ,000 sq.ft. office and warehouse 86 authorized sales and service offices in USA and Canada.

Similar documents
on-demand Minimizing Energy Loss through order to meet Sustainable Design Standards

MDVS Tag: DF-1, DF-2. Architect/Engineer: Contractor: EXHAUSTO Job File: Use. Sizes. Listings. Description. CSI Specifications.

Designing Thoughtful Green Performance - On-Demand Venting and Exhaust Systems

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

Fundamentals of Making Energy-Saving and Cost-Efficient Boiler Exhaust Systems Design Solutions and Applications

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

RSIB Power Venter

ENERVEX RSV CHIMNEY FAN

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

NEW. Demand-Controlled Exhaust Systems for Commercial and Industrial Bakeries. For Commercial and industrial Baking Oven Systems

EBC 12 Modulating Fan Control

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...

ENERVEX IPVB INLINE POWER VENTER

IPVB EC inline power venter

MEC 18 Mechanical Exhaust Control

Boiler Venting. Definitions, Theory and Applications. Presented by: Jason Geagan, National Sales Manager US Draft Co Fort Worth, TX

Venting Modern Heating Appliances

CONDENSING HIGH EFFICIENCY BOILERS

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

AHRI Certified up to. 95% efficiency P-K MACH HIGH EFFICIENCY, COMMERCIAL BOILERS

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

Forced Draft Boiler Flue Gas Venting: Problems & Solutions. Presented by Steve Connor and Patrice Gouin January 27, 2016

Multistory Fireplace & Exhaust System

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

Draft Control D R A F T C O N T R O L G U I D E w w w. f i e l d c o n t r o l s. c o m August 2007

2012 INTERNATIONAL FUEL GAS CODE VENTS

Tjernlund Side Wall Venting Products

THE ULTIMATE VENTING SYSTEM

Draft Controls. When to use a Draft Control

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

FINNED WATER-TUBE POOL HEATERS

SECTION HEATING BOILERS

TRIAD Boiler Systems, Inc Atlantic Drive, Unit 2 West Chicago, IL

90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer

Multistory Fireplace & Exhaust System

FIELD DRAFT CONTROLS

P-K MACH HIGH EFFICIENCY, COMMERCIAL BOILERS

ENERVEX VHX VORTEX HEAT RECOVERY CENTER

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

DIVISION FINNED WATER-TUBE WATER HEATERS

BEST DRAFT CONTROL: MANUAL DAMPERS IN MULTIPLE BOILER SYSTEMS

Suggested Specifications Prestige Excellence 110

A. Product Data: Include rated capacities, furnished specialties and accessories.

fans & heaters SIMPLE, ROBUST AND RELIABLE

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*

ENERVEX GSV GREASE FAN

ADC150 Automatic Draft Control

Boiler Technical Specifications (2013)

R-Series Oil Burners. Riello Burners a world of experience in every burner we sell. Reliable Combustion Solutions

Technical data Chimney fans, controllers & accessories in systems for multiple heating appliances

KIC Air Curtains. Technical Guide

DIVISION FINNED WATER-TUBE WATER HEATERS

FINNED WATER-TUBE POOL HEATERS

LARGE CAPACITY HEATERS

ENERVEX ADC100 DRAFT CONTROL

GQVC-12 HVAC EQUIPMENT. GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces.

INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

TABLE OF CONTENTS BRADFORD WHITE BOILERS

DOM-5. Domestic Hot Water Heaters & Boilers

Revitalize Building Mechanical Systems (4619)

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Power Flame Incorporated

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

WATER-TUBE POOL HEATERS

GB Condensing Gas Boiler

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

Air and technology System solutions with a perspective... System solu

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

Direct Fired Heater Model AD Specification

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

RTC. Stainless Steel Condensing Floor Standing Boilers Technical data sheet. High efficiency commercial heating

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

DIVISION FINNED WATER-TUBE BOILERS

RS Chimney Fan for Solid Fuel Applications

Indirect Gas-Fired Make-Up Air

WATER-TUBE POOL HEATERS

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Gas-Fired Indoor and Outdoor Duct Furnaces

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

DACC Health Sciences Building Air Handler Assessment/Study

CHAPTER 8 CHIMNEYS AND VENTS

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

Adopting Agency BSC SFM. Adopt Entire Chapter X X X X X X X X X X Adopt Entire Chapter as amended (amended sections listed below)

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

DIRECT FIRED HOT WATER BOILER Atmospheric Gas Fired T Models 300,000 to 6,800,000 BTU Gas Fired

Concrete Applications

Transcription:

EXHAUSTO Inc in North America In Atlanta since 1990 25,000 sq.ft. office and warehouse 86 authorized sales and service offices in USA and Canada.

The First Fan - 1957 The first chimney fan - a first worldwide and the foundation of EXHAUSTO s existence

A 50-year Old Company Founded in 1957 300,000+ sq.ft. of manufacturing and administration High-tech ISO 9001 certified manufacturing facilities

Certifications

Mechanical Draft Systems

Products RSV Fan Capacity: 6,000 MBH on CAT I Appliances 10,000 MBH on CAT IV Appliances 3/16 Cast aluminum housing Hinged for easy service and cleaning Direct drive Class H insulated motor Maintenance free 482 ºF Continuous Duty 575 ºF Intermittent Duty UL 378 Draft Equipment

Products RSV Fan The RSV fan can vent all appliance categories with or without barometric dampers Up to 6,000-10,000 MBH High temperature motor eliminates the need for secondary fan cooling Simple design with few components reduces the risk of failure and simplifies service

CASI Chimney Automation System

RSIB Power Venter Capacity: 8,000 MBH on CAT I Appliances 15,000 MBH on CAT IV Appliances SS316 construction Removable access door Direct drive Class A insulated motor - eliminates the need for secondary fan cooling Maintenance free Up to 575 ºF Duty The RSIB fan can vent category I, II, III & IV appliances Simple design with few components reduces the risk of failure and simplifies service RSIB is of Type B, Spark Resistant Construction UL 378 Draft Equipment

RSIF Power Venter Capacity: 1,800 MBH on CAT I Appliances Rated to 400 F non-condensing applications Forward inclined impeller. Statically and dynamically balanced. Insulated housing in galvanized steel Hinged fan housing easily opens to provide easy access to duct and impeller Direct drive, variable speed, TEFC motor located outside housing for easy access.

Modulating Overdraft Damper System

Controls EBC30 Modulating Pressure Control

Controls EBC30 Features 100% microprocessor based control Plug-and-Play initialization process Integrated PDS function with adjustable time delay Intermittent or continuous operation for all fans Field-adjustable PID loop Priority Operation function Bearing Cycle function Rotation Check for three-phase fans

Controls PDS Proven Draft Switch Differential pressure transducer Ensures proper draft before and during appliance operation Probe included Range: 0.04 to 0.60 W.C.

Controls VFD Variable Frequency Drive Pre-programmed from the factory 1 5 HP in 200 Volt Class input 1 7. All wiring is done externally conduits and wires are pre-installed Quick-menu for field adjustable Parameters NEMA 1 rating

Products Accessories SCA Steel Chimney Adapter Steel chimney adapter Used as transition between a round stack and the fan Made of 304 stainless steel

Products Accessories BBF Balancing Baffle Balancing baffle with flange connections For positive pressure stacks For balancing pressure drops on systems with multiple appliances

CASV Applications Stack Downsizing Hazen High School Renton, WA Soldier Field - Chicago, IL

CASV Applications - Aesthetics Getty Center Los Angeles Rigel San Francisco

MCAS Mechanical Combustion Air Supply Systems

MCAS Modulating Combustion Air Supply System

MCAS Components SFTA Fan Seven Models 1,500 30,000 cfm Fan can be mounted indoors Impeller cast aluminum. Housing in steel Direct drive, variable speed, TEFC motor located outside housing for easy access. Variable Frequency Drive is used on three phase models (VFD should be located inside the building).

MCAS Components BESF/BESB Fan Seven Models 450 5500 cfm Fan can be mounted indoors or outdoors. Impeller - statically and dynamically balanced. Insulated housing in galvanized steel Hinged fan housing easily opens to provide easy access to duct and impeller Direct drive, variable speed, TEFC motor located outside housing for easy access. Variable Frequency Drive is used on three phase models In-door or out-door installations (VFD should be located inside the building).

EBC30 Modulating Control Modulating Combustion Air Supply System Chimney Automation System

SBC Center San Antonio, TX Two 16 inch ducted combustion air inlets Instead of Two 10 foot high by 15 foot long Louvers

Lifetime Fitness Savage, MN

Marriott Waterfront Annapolis, MD One 24 inch ducted combustion air inlet Instead of One 90 ft.² louver

MDVS Mechanical Dryer Venting Systems

MDVS Mechanical Dryer Venting System

MDVS Components - BESB Fan Four Models 1200 5500 cfm ETL Listed to UL705 :"The product (BESB/MDVS) covered by this report is a modulating air exhaust system. The product consists of a box ventilator and a modulating control for permanent installation. Its intended use is exhausting of lint-laden air from single or multiple type I and type II residential and commercial clothes dryers whether electric or gasfired, exhausting commercial hoods, or for providing make-up air for laundries or mechanical rooms. The box ventilator can be installed indoors or outdoors."

MEC 18 Control Monitor draft in multi-story building exhaust applications Controls RSV, EFH, BESF and BESB EBC12 functions UL 508 and CSA C22.2 Standard for Industrial Control Equipment

Kitchen and Dryer Exhaust Madigral Lofts, MD

Applications Sports Arenas Hotels Hospitals Schools Fitness Facilities Apartments / Condominiums

Appliance Categorization Atmospheric Fan Assisted Forced Draft Scotch Marine Draft Hood Draft Diverter I III Negative Fan Assisted (high efficiency) II IV Condensing Positive

Z223.1-54 (Venting of equipment) 12.1 Minimum Safe Performance A venting system shall be designed and constructed so as to develop a positive flow adequate to remove flue or vent gases to the outside atmosphere. 12.4.1 Equipment Draft Requirement A venting system shall satisfy the draft requirement of the equipment in accordance with the manufacturer s instructions.

Common Code Violations (NFPA 54) Z223.1-2006 12.11.9.2 (Venting of Equipment) (NFPA 54) Z223.1-2006 13.2 (Sizing of Venting Systems)

Common Code Violations 3" 4" 5" 6" 7" 8" 9" 10" 12" 14" 16" 7" 10" 12" 14" 18" 22" 22" 26" 30" 36" 42" (NFPA 54) Z223 Sizing Tables (NFPA 54) Z223.1-2006 13.2.18 (Sizing of Venting Systems)

Mechanical Draft Systems Defined Z223.1-2006 Standard for Venting of Equipment 12.4.3.1 Mechanical draft systems shall be listed and shall be installed in accordance with the terms of their listing and both the appliance and the mechanical draft system manufacturer s instructions. 12.4.3.2 Appliances requiring venting shall be permitted to be vented by means of mechanical draft systems of either forced or induced draft design. Exception: Incinerators 12.4.3.5 Where a mechanical draft system is employed, provision shall be made to prevent flow of gas to the main burners when the draft system is not performing so as to satisfy the operating requirements of the equipment for safe performance

Commercial Laundry Radisson, Orlando, FL

Responsibility Reduce Emissions Environmentally friendly Low Energy Recyclable Materials Demand-Controlled

And Still Going Strong... Reliable 1990 1992 2001 2007 Disney Allstar Resorts Orlando, Florida 60 RSV installed 2 RSV replaced The White House Washington D.C 12 RSV installed Sample 3 xx RSV installed

Eliminates Potential Risks Seismological Safe

Eliminates Potential Risks Seismological Safe

Case: CBS Studio, Hollywood, CA Boiler replacement. Must meet air quality requirements and eliminate need for substantial stack work. Solution: Four condensing boilers installed in a modular system using a single common stack and a CASV system for venting. Benefits: Simple and Aesthetically pleasing Limited stack work using existing chase