Thermal Mass Flowmeter Sensyflow FMT500-IG

Similar documents
ProcessMaster FEP300, FEP500 HygienicMaster FEH300, FEH500 Electromagnetic Flowmeter

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

Introduction. Additional information. Additional instructions for IEC compliant devices. Measurement made easy

Pressure Transmitter cerabar M PMC 41/45 cerabar M PMP 41/45/46/48 with Output Signal ma/hart

Functional Safety Manual June pointek CLS500/LC500

Proservo NMS5- / NMS7-

Pressure Transmitter cerabar S PMC 731/631 cerabar S PMP 731/635 with ma output signal

Differential Pressure Transmitter deltabar S PMD 230/235 deltabar S FMD 230/630/633 with ma output signal

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

United Electric Controls One Series Safety Transmitter Safety Manual

100 & 120 Series Pressure and Temperature Switches Safety Manual

User s Manual. YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters. Manual Change No

SIPART. Electropneumatic positioner Functional safety for SIPART PS2. Introduction. General safety instructions 2. Device-specific safety instructions

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

FUNCTIONAL SAFETY CERTIFICATE

SIL Safety Guide Series MS Single-Acting Spring-Return Hydraulic Linear Actuators

430128A. B-Series Flow Meter SIL Safety Manual

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

Digital EPIC 2 Safety manual

Soliphant M with electronic insert FEM52

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

Safety in the process industry

Failure Modes, Effects and Diagnostic Analysis

Overfill Prevention Control Unit with Ground Verification & Vehicle Identification Options. TÜVRheinland

Deltapilot S FMB70. Functional Safety Manual. Level and Pressure Measurement with Output Signal ma

FMEDA Report. Failure Modes, Effects and Diagnostic Analysis. KFD0-CS-Ex*.54* and KFD0-CS-Ex*.56* Project: X7300

Technical Report Proven In Use SITRANS P500

Cerabar S PMC71, PMP71, PMP75

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

Failure Modes, Effects and Diagnostic Analysis. PR electronics A/S Rønde Denmark

Certification Report of the ST3000 Pressure Transmitter

Technical Manual for the Manual Alarm Call Point BG

STT850 and STT750 SmartLine Temperature Transmitter HART Communications Options Safety Manual 34-TT Revision 4 September 2017

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, Minnesota USA

FUNCTIONAL SAFETY MANUAL

Thermocouples and Resistance Thermometers

Certification Report of the ST 3000 Pressure Transmitter with HART 6

Safety Manual. XNX TM Universal Transmitter. Table of Contents SIL 2 Certificates Overview Safety Parameters

PPA Michaël GROSSI - FSCE PR electronics

Liquiphant S, Nivotester FDL60/61, FTL670

FUNCTIONAL SAFETY MANUAL

Measurement of Safety Integrity of E/E/PES according to IEC61508

Guidelines. Safety Integrity Level - SIL - Valves and valve actuators. February Valves

FMEDA and Proven-in-use Assessment. Pepperl+Fuchs GmbH Mannheim Germany

Failure Modes, Effects and Diagnostic Analysis

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

Operating Manual MS220DA

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update

Rosemount 2140:SIS Level Detector

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

Safety Manual. XNXTM Universal Transmitter. Fault Diagnostic Time Interval Proof Test Proof Testing Procedure

IEC Functional Safety Assessment

FUNCTIONAL SAFETY CERTIFICATE. BG Break Glass Unit

Functional Safety Manual Oil Leak Detector NAR300 System

Functional Safety Solutions

Operating Guide Safe Torque Off

Failure Modes, Effects and Diagnostic Analysis

Operating Manual MS220KA and MSR220KA

Operating Instruction OI/TSC400-EN. SensyTemp TSC400 Industrial thermometer. For plug-in connection For screw-in connection For surface measurement

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, MN USA

FUNCTIONAL SAFETY OF ELECTRICAL INSTALLATIONS IN INDUSTRIAL PLANTS BY OTTO WALCH

Functional safety manual Liquiphant M/S with FEL57 and Nivotester FTL325P

Failure Modes, Effects and Diagnostic Analysis

GMA200-MW4. User Manual. Gas detection controller for wall mounting

HAWK Measurement Systems Pty. Ltd. Centurion CGR Series Safety Manual

Rosemount Functional Safety Manual. Manual Supplement , Rev AF March 2015

SLG 700 SmartLine Level Transmitters Guided Wave Radar Safety Manual 34-SL Revision 4.0 December 2017

Failure Modes, Effects and Diagnostic Analysis

Safety instrumented systems

Automation, Software und Informationstechnologie

Failure Modes, Effects and Diagnostic Analysis

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express

Failure Modes, Effects and Diagnostic Analysis

Gammapilot M FMG60. Functional safety manual. Radiometric measurement technology Maximum point level detection

Integrated but separate

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Failure Modes, Effects and Diagnostic Analysis

Technical Manual for the Horn - DB1PUL DB1HP UL

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Failure Modes, Effects and Diagnostic Analysis

Siemens Process Automation End-user Summit- 2011

Gas Controller Module GC-06

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

Proof Testing Level Instruments

Assessment of the Safety Integrity of Electrical Protection Systems in the Petrochemical Industry

Functional Safety SIL Safety Integrity Level

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

HIPPS High Integrity Pressure Protection System

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Process Safety - Market Requirements. V.P.Raman Mott MacDonald Pvt. Ltd.

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

For Complete Fire and Gas Solutions

Transcription:

Pos: 1 /Titelblätter / Copyright/SIL/Durchfluss/SIL-Handbuch Sensyflow FMT500-iG Analog / HART @ 22\mod_1222423613156_3101.doc @ 218417 @ Pos: 2 /Titelblätter / Copyright/Copyright-Seite @ 32\mod_1247732119296_3101.doc @ 288410 @ SIL-Safety Instructions 37/14-40-EN Thermal Mass Flowmeter Sensyflow FMT500-IG Analog / HART Information regarding functional safety

Pos: 3 /Inhaltsverzeichnis/Inhaltsverzeichnis für alle Dokumente @ 0\mod_1138710310890_3101.doc @ 3129 @ Contents Blinder Text Thermal Mass Flowmeter Sensyflow FMT500-IG SIL-Safety Instructions 37/14-40-EN 09.2009 Rev. A Manufacturer: ABB Automation Products GmbH Borsigstraße 2 63755 Alzenau Germany Tel.: +49 551 905-534 Fax: +49 551 905-555 CCC-support.deapr@de.abb.com Customer service center Phone: +49 180 5 222 580 Fax: +49 621 381 931-29031 automation.service@de.abb.com Copyright 2009 by ABB Automation Products GmbH Subject to changes without notice This document is protected by copyright. It assists the user in safe and efficient operation of the device. The contents of this document, whether whole or in part, may not be copied or reproduced without prior approval by the copyright holder. 2 Sensyflow FMT500-IG 37/14-40-EN

Contents 1 Field of Application...4 2 Acronyms and abbreviations...4 3 Relevant standards...5 4 Other applicable documents and papers...5 5 Terms and definitions...6 6 Safety function...7 7 Periodic checks...9 7.1 Returning devices...10 8 Configuration...10 9 Characteristics for functional safety...11 10 Appendix...13 11 Management Summary FMEDA...14 37/14-40-EN Sensyflow FMT500-IG 3

Pos: 4 /Überschriften/1/A - C/Anwendungsbereich @ 1\mod_1146730389234_3101.doc @ 8296 @ 1 Pos: 5 /SIL-Sicherheitshinweise/Durchfluss/FMT500-IG/Anwendungsbereich Masse-Durchflussmesser FMT500-iG @ 22\mod_1222423937546_3101.doc @ 218474 @ Pos: 6 /Überschriften/1/A - C/Akronyme und Abkürzungen @ 1\mod_1146731222953_3101.doc @ 8338 @ 1 Pos: 7 /SIL-Sicherheitshinweise/Durchfluss/FMT500-IG/Akronyme und Abkürzungen @ 22\mod_1222424064562_3101.doc @ 218500 @ Field of Application 1 Field of Application Mass flow measurement of gases and gas mixtures in closed pipelines that meet the safety engineering requirements of IEC 61508 / IEC 61511. The operating limits are defined in the data sheets and operating instructions for the separate models. In case of questions, please contact your ABB partner. 2 Acronyms and abbreviations Acronym/ Abbreviati on HFT MTBF MTTR PFD PFDAVG SIL SFF Low demand mode DCS English Hardware Fault Tolerance Mean Time Between Failures Mean Time To Repair Probability of Failure on Demand Average Probability of Failure on Demand Safety Integrity Level Safe Failure Fraction Low demand mode of operation Distributed Control System Description Hardware error tolerance of the unit. Ability of a functional unit (hardware) to continue to perform a required function in the presence of faults or errors. Mean Time Between Failures Mean time between occurrence of an error in a unit or system and its repair. Probability of hazardous failures for a safety function on demand Average probability of hazardous failures for a safety function on demand The international standard IED 61508 defines four discrete Safety Integrity Levels (SIL 1 to SIL 4). Each level corresponds to a range of probability for the failure of a safety function. The higher the Safety Integrity Level of the safety-related systems, the lower the probability that they will perform the requested safety function. Fraction or percentage of failures that do not have the potential to put the safety-related system in a hazardous or fail-to-function state. Measurement type with low request rate. Measurement type for which the request rate for the safety-related system is not more than once a year and not greater than twice the frequency of the retest. Control systems used in industrial applications to monitor and control decentralized units. 4 Sensyflow FMT500-IG 37/14-40-EN

Pos: 8 /Überschriften/1/G - I/Geltende Normen @ 1\mod_1146731568625_3101.doc @ 8352 @ 1 Pos: 9 /SIL-Sicherheitshinweise/Durchfluss/FMT500-IG/Geltende Normen @ 22\mod_1222424111062_3101.doc @ 218526 @ Pos: 10 /Überschriften/1/M - O/Mitgeltende Dokumente und Unterlagen @ 7\mod_1174319109531_3101.doc @ 73216 @ 11 Pos: 11 /SIL-Sicherheitshinweise/Durchfluss/FMT500-IG/Mitgeltende Dokumente und Unterlagen @ 22\mod_1222424178531_3101.doc @ 218571 @ Pos: 12 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830 @ Relevant standards Acronym/ Abbreviati on HMI DTM English Human Machine Interface Device Type Manager Description In this case, the HMI is a combined module consisting of LCD display and local keyboard. A DTM is a software module that provides specific functions for accessing device parameters, setup and operation of devices, and diagnostics of problems. The DTM is not an executable software. It requires an FDT container program to be activated. MBA Lower Range Value Start of measurement range MBE Upper Range Value End of measurement range 3 Relevant standards Standard IEC 61508, Part 1 to 7 IEC 61511 Description Functional safety of electrical / electronic / programmable electronic safety-related systems. Functional safety Safety Instrumented Systems for the process industry sector 4 Other applicable documents and papers Observe the following documents in addition to the safety information: Product name Document name Designation and application Sensyflow FMT500-IG 10/14-6.41-DE OI/FMT500-IG COM/FMT500-IG/HART Data Sheet Operating Instructions Interface Description HART These are also available on the ABB internet at www.abb.com/flow. In addition, the user of this device is responsible for ensuring compliance with the respective legal regulations and standards. 37/14-40-EN Sensyflow FMT500-IG 5

Pos: 13 /Überschriften/1/A - C/Begriffe und Definitionen @ 1\mod_1146731780265_3101.doc @ 8366 @ 1 Pos: 14 /SIL-Sicherheitshinweise/Allgemein/Begriffe und Definitionen/Begriffe und Definitionen @ 15\mod_1195466362140_3101.doc @ 141114 @ Pos: 15 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830 @ Terms and definitions 5 Terms and definitions Terms Dangerous failure Safety-related system Safety function Explanation A failure that has the potential to place the safety-related system in a dangerous state or render the system inoperative. A safety-related system performs the safety functions that are required to achieve or maintain a safe condition, e.g., in a plant. Example: pressure meter, logics unit (e.g., limit signal generator) and valve form a safety-related system. A specified function that is performed by a safety-related system with the goal, under consideration of a defined hazardous incident, of achieving or maintaining a safe condition for the plant. Example: limit pressure monitoring 6 Sensyflow FMT500-IG 37/14-40-EN

Pos: 16 /Überschriften/1/S - U/Sicherheitsfunktion @ 1\mod_1146732234250_3101.doc @ 8380 @ 1 Pos: 17 /SIL-Sicherheitshinweise/Durchfluss/FMT500-IG/Sicherheitsfunktion FMT500-IG @ 22\mod_1222424411953_3101.doc @ 218622 @ Safety function 6 Safety function The thermal mass flowmeter FMT500-IG Analog / HART generates a signal proportional to the (4 20 ma) mass flowrate. All safety functions refer strictly to the analog output signal. The entire valid range for the output signal must be configured between min. 3.8 ma and max. 20.5 ma (factory setting). Warning! In safety mode, HART communication cannot occur. Alarm behavior and current output When a critical error is detected, the configured alarm is generated and fed to a downstream logics unit, e.g., a DCS. The alarm current is checked for overshoot of a defined maximum value. There are two selectable modes for the alarm current: HIGH ALARM (high alarm, max. alarm current); this is the factory setting LOW ALARM (low alarm, min. alarm current) The low alarm current is 3.5 ma. The high alarm current is 22.5 ma. Default configuration for high alarm max. current output 22.5 ma. In the following cases, a detected error is displayed independently of the configured alarm current within the low alarm range: Runtime errors Power supply errors, storage errors Warning! To ensure accurate error monitoring, the following conditions must be fulfilled: The low alarm must be configured to a value 3.6 ma. The high alarm must be configured to a value 21 ma. The DCS must identify the configured high and low alarms as malfunctions, and the alarm must be configured according to the desired setup. 37/14-40-EN Sensyflow FMT500-IG 7

Pos: 18 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830 @ Safety function The device does not meet safety requirements under the following conditions: During setup With write protection off During a simulation During an inspection of the safety function The percentage of failures that do not place the device in a hazardous functional state is provided by the SFF value. Total safety accuracy The value defined for the overall accuracy of the safety function for this device is ± 2 % of the measuring range. The basic accuracy depends on the gas, pressure and temperature and can be found in the appropriate data sheets. 8 Sensyflow FMT500-IG 37/14-40-EN

Pos: 19 /Überschriften/1/V - Z/Wiederkehrende Prüfungen @ 1\mod_1146733339140_3101.doc @ 8408 @ 1 Pos: 20 /SIL-Sicherheitshinweise/Durchfluss/FMT500-IG/Wiederkehrende Prüfungen @ 22\mod_1222424520156_3101.doc @ 218647 @ Pos: 21 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830 @ Periodic checks 7 Periodic checks Safety inspections The safety function for the entire safety loop must be checked regularly in accordance with IEC 61508. The inspection intervals are defined when calculating the individual safety loops for a system. Users are responsible for selecting the type of check and the intervals within the specified period. The PFD AV value depends on the selected inspection interval. For the PFD AV values in the SIL declaration of conformity, the inspection interval T[Proof] for checking the safety function is 1 year. For additional inspection intervals with corresponding PFDAV values, refer to the chapter Management Summary FMEDA. Inspections must be conducted in a manner that enables users to verify proper function of the safety equipment in combination with all components. One possible procedure for recurring tests to detect hazardous and unidentified device errors is described in the following section. Some 99 % of the Du errors in the flowmeter are detected by this test. Without step 7 approximately 50 % of the Du errors in the flowmeter are detected by this test. Checking the safety function To check the safety function of the device, proceed as follows: 1. Bridge the safety DCS or take other appropriate measures to ensure the alarm is not triggered unintentionally. 2. Set the current output of the transmitter to a high alarm value by using a HART command or the DTM simulation command (Diagnosis/Simulation/Current Output). 3. Check whether the current output signal reaches this value. 4. Set the current output of the transmitter to a low alarm value by using a HART command or the DTM simulation command. 5. Check whether the current output signal reaches this value. 6. Restart by switching off the device. 7. Performing a 2-point flowmeter calibration. 8. Remove the bridge from the safety DCS or use another method to restore the standard operating mode. 9. After performing the test, the events must be documented and archived properly. 37/14-40-EN Sensyflow FMT500-IG 9

Pos: 22 /Sicherheit/Durchfluss/FMT500-IG/Rücksendung von Geräten (Therm. Masse-Durchflussmesser) @ 27\mod_1240227589937_3101.doc @ 260031 @ 2 Pos: 23 /Sicherheit/Allgemein/Adresse für Rücksendung (Temperatur und TM-Durchflussmesser) @ 32\mod_1247737276859_3101.doc @ 288547 @ Please Pos: 24 /==== Leeres Modul mit einer Absatzmarke, IM, 1-spaltig ==== @ 14\mod_1194422545687_0.doc @ 136717 @ Pos: 25 /==== Leeres Modul mit einer Absatzmarke, IM, 1-spaltig ==== @ 14\mod_1194422545687_0.doc @ 136717 @ Pos: 26 /Überschriften/1/J - L/Konfiguration @ 0\mod_1140688219031_3101.doc @ 3154 @ 1 K Pos: 27 /SIL-Sicherheitshinweise/Durchfluss/FMT500-IG/Konfiguration @ 22\mod_1222424675265_3101.doc @ 218672 @ Pos: 28 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830 @ Configuration 7.1 Returning devices Use the original packaging or a secure transport container of an appropriate type if you need to return the device for repair or recalibration purposes. Fill out the return form (see the Appendix) and include this with the device. The EU Directive governing hazardous materials dictates that the owners of any hazardous waste are also responsible for disposing of it. All devices delivered to the manufacturer must be free from any hazardous materials (acids, alkalis, solvents, etc.). Pipe components and flowmeter sensors contain hollow spaces. If they have been used in conjunction with hazardous materials, they must therefore be rinsed out in order to neutralize any such substances. The owner will be charged for any costs incurred as a result of the device not having been adequately cleaned or of any failure to dispose of hazardous materials. The manufacturer reserves the right to return a contaminated device. Please contact Customer Center Service acc. to page 2 for nearest service location. 8 Configuration The device was parameterized and tested according to customer order. The device can be additionally configured with the local display or DTM using the HART interface. Other parameterization or configuration tools such as mobile handheld terminals are not described. During parameterization, proper operation of the device is not ensured. Refer to the operating instructions for proper procedure for configuration. Warning! In safety mode, configure the current output to high alarm current or low alarm current. The parameterization 0 20 ma is not approved; for safety mode only 4... 20 ma is permitted. 10 Sensyflow FMT500-IG 37/14-40-EN

Pos: 29 /Überschriften/1/M - O/Merkmale der Funktionssicherheit @ 1\mod_1146735463078_3101.doc @ 8429 @ 1 Pos: 30 /SIL-Sicherheitshinweise/Durchfluss/FMT500-IG/SIL-Konformitätserklärung @ 22\mod_1222424768937_3101.doc @ 218698 @ Characteristics for functional safety 9 Characteristics for functional safety For the safety-relevant technical parameters, refer to the following SIL declaration of conformity. 37/14-40-EN Sensyflow FMT500-IG 11

Pos: 31 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830 @ Characteristics for functional safety 12 Sensyflow FMT500-IG 37/14-40-EN

Pos: 32 /Überschriften/1/A - C/Anhang @ 0\mod_1132904773022_3101.doc @ 3134 @ 11 Pos: 34 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830 @ Appendix 10 Appendix Pos: 33 /Anhang/Allgemein/Rücksendeformular @ 0\mod_1132757486454_3101.doc @ 3820 @ Statement on the contamination of devices and components Repair and/or maintenance work will only be performed on devices and components if a statement form has been completed and submitted. Otherwise, the device/component returned may be rejected. This statement form may only be completed and signed by authorized specialist personnel employed by the operator. Customer details: Company: Address: Contact person: Fax: Telephone: E-mail: Device details: Type: Reason for the return/description of the defect: Serial no.: Was this device used in conjunction with substances which pose a threat or risk to health? Yes No If yes, which type of contamination (please place an X next to the applicable items)? Biological Corrosive/irritating Combustible (highly/extremely combustible) Toxic Explosive Other toxic substances Radioactive Which substances have come into contact with the device? 1. 2. 3. We hereby state that the devices/components shipped have been cleaned and are free from any dangerous or poisonous substances. Town/city, date Signature and company stamp 37/14-40-EN Sensyflow FMT500-IG 13

Pos: 35 /Überschriften/1/M - O/Management Summary FMEDA @ 8\mod_1174319301890_3101.doc @ 73237 @ 11 Pos: 36 /SIL-Sicherheitshinweise/Durchfluss/FMT500-IG/PDF-Seiten der EXIDA FMEDA-Report @ 23\mod_1223550923921_0.doc @ 220833 @ Management Summary FMEDA 11 Management Summary FMEDA 14 Sensyflow FMT500-IG 37/14-40-EN

Management Summary FMEDA 37/14-40-EN Sensyflow FMT500-IG 15

Management Summary FMEDA 16 Sensyflow FMT500-IG 37/14-40-EN

Management Summary FMEDA 37/14-40-EN Sensyflow FMT500-IG 17

Management Summary FMEDA 18 Sensyflow FMT500-IG 37/14-40-EN

Management Summary FMEDA 37/14-40-EN Sensyflow FMT500-IG 19

Management Summary FMEDA 20 Sensyflow FMT500-IG 37/14-40-EN

Management Summary FMEDA 37/14-40-EN Sensyflow FMT500-IG 21

Management Summary FMEDA 22 Sensyflow FMT500-IG 37/14-40-EN

Pos: 37 /Rückseiten/Alzenau_Durchfluss @ 32\mod_1247737211578_3101.doc @ 288520 @ === Ende der Liste für Textmarke Inhalt === Management Summary FMEDA 37/14-40-EN Sensyflow FMT500-IG 23

ABB has Sales & Customer Support expertise in over 100 countries worldwide. www.abb.com/flow The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in the Fed. Rep. of Germany (09.2009) ABB 2009 3KXF421000R4801 37/14-40-EN Rev. A ABB Limited Salterbeck Trading Estate Workington, Cumbria CA14 5DS UK Tel: +44 (0)1946 830 611 Fax: +44 (0)1946 832 661 ABB Inc. 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 ABB Automation Products GmbH Borsigstr. 2 63755 Alzenau Germany Tel: +49 551 905-534 Fax: +49 551 905-555 CCC-support.deapr@de.abb.com