Operator s Manual CHILLER ( CH SERIES) Models: CH750, CH751, and CH951

Similar documents
Operator s Manual CHILLER ( CH SERIES) Models: CH750, CH751, and CH951

Operator s Manual CHILLER ( CHILLER SERIES) Models: CH550 and CH 551

CHILLERS. Operator s & Installation Manual

CH750, CH751 & CH951 CHILLERS

Telephone (800) Facsimile (800)

Installation Manual VA 13 CARBONATOR IMPORTANT: Manual Part No

CHILLER. Operator s & Installation Manual

CH250 AND CH251 CHILLERS

ICE/BEVERAGE DISPENSER

ICE/DISPENSER Model D3030

CHILLER. Operator s & Installation Manual

CHILLER MODEL: CH1500, 2000 AND 3000

ICE/BEVERAGE DISPENSER

ICE/BEVERAGE DISPENSERS

CMP ICE MAKER DISPENSER. Installation and Service Manual

ICE/BEVERAGE DISPENSER

CHILLER. Model CH3000. Operator s & Installation Manual

CFF-500 CHILLER. Operator s & Installation Manual. Release Date: November 3, 1996 Publication Number: Revision Date: March 25, 2014 Revision: F

Owner / Operator Manual Commercial Refrigeration Service, Inc. (866)

PM R34,35,38 Issue 5 7/02 PRODUCT MANUAL

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

IMI CORNELIUS CHILLER

CRYOCOOL Systems Product Manual. Water cooled floor standing units (WC)

Surna 25-Ton Chiller Operating & Maintenance Manual

MACH N-407 Heat Pump Air-Cooled Chiller

PDF Created with deskpdf PDF Writer - Trial ::

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

INSTALLATION MANUAL. Series 322 Ice Cube Machine SPECIFICATIONS UNPACKING. Series 322 Ice Cube Machine Installation Instructions

Installation, Operation and Maintenance Manual

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

INSTALLATION & OPERATION MANUAL

Installation Manual CARBONATOR With Plain-Water Booster

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

Glass Door Merchandiser. Model RM-49

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

MAC N-407 Air-Cooled Chiller

HX-1000 & HX-2000 Recirculating Chiller. NESLAB Manual P/N Rev 03/19/97. Instruction and Site Preparation Manual

Operation and Maintenance Haskris LX-Series, R-Series, WW-Series, OPC-Series

Trouble Shooting Guide FAA, 3-phase (D3631)

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

T-Series Air Conditioner T20 Model

MODELS B1PA024, 030 AND 036

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Power Pack Service Manual

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Power Pack Service Manual

Trouble Shooting Guide RAA, 1-phase (D3627)

Rev B, 9/2/2009. Kodiak Chiller Overview

T-Series Air Conditioner T15 Model

Trouble Shooting Guide PAA, 1-phase (D3731)

SCE170 SERVICE PARTS

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

Trouble Shooting Guide PWA, 3-phase (D10571)

Glass Door Merchandiser

SUPER ASTRA PRODUCT MANUAL. PM R20 Issue 3 1/00

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

How to Select and Size a Chiller

KODIAK RECIRCULATING CHILLERS TECHNICAL MANUAL RC006, RC009, RC011, RC022, RC030 and RC045 G03, H03 and J03 Series

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

AIR COOLED PACKAGED CHILLER

Power Pack Service Manual

AQUA LOGIC S MULTI-TEMP Water-Cooled Marine Duty Series chiller

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

POWER PACK SERVICE MANUAL

POWER PACK SERVICE MANUAL

InstructIon Manual KrEs EQuIPMEnt stands

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

Bulletin (Jan 2011) And User s Guide

Glass Door Merchandiser. Model RM-45-SD

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

I.O.M. #075 11/05 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE. with CF-1 Instrument

Covering Air-Cooled Models from 1 to 10 tons with M1 Chiller Control Instrument

INSTALLATION and OPERATION INSTRUCTIONS

HX-900 Recirculating Chiller

SELF-CONTAINED FLAKER

Models Series Series

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Models Series Series

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

T-Series Air Conditioner T53 Model

OACS Outdoor Air-Cooled Central Chillers

A B A B4

Owner / Operator Use and Care Guide I SERIES 224 ICE CUBE MACHINE

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

ABS HOPPER LID SWITCH KIT ASSEMBLY

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

Transcription:

IMI CORNELIUS REMCOR INC 500 REGENCY DRIVE GLENDALE HEIGHTS, IL 60139 2268 Telephone (800) 551 4423 Facsimile (800) 519 4423 Operator s Manual CHILLER ( CH SERIES) Models: CH750, CH751, and CH951 Part No. 91256 Revision Date: August 9, 2002 Revision: C THIS DOCUMENT CONTAINS IMPORTANT INFORMATION This Manual must be read and understood before installing or operating this equipment IMI CORNELIUS INC; 2002 PRINTED IN U.S.A

TABLE OF CONTENTS INSTALLATION INSTRUCTIONS............................ 2 Location........................................................... 2 Plumbing.......................................................... 2 Electrical.......................................................... 2 START UP/OPERATION................................... 2 MAINTENANCE........................................... 3 SERVICE................................................. 3 Removing Wrapper................................................. 3 Replacing Switch................................................... 3 Replacing Standard Thermostat...................................... 3 Replacing Electronic Differential Thermostat........................... 4 Replacing Fan Blade and/or Motor.................................... 4 Replacing Pump................................................... 4 FLUID RECOMMENDATION................................ 5 TROUBLESHOOTING GUIDE............................... 6 Chiller Does Not Operate............................................ 6 No Circulation of Chilled Water....................................... 6 Inadequate Cooling................................................. 6 PARTS LIST.............................................. 7 WARRANTY.............................................. 8 LIST OF FIGURES FIGURE 1. CH750, CH751 AND CH951 EXPLODED VIEW..... 7

INTRODUCTION The REMCOR CH Series Water Chillers (Models CH750 A, CH751 A, and CH951 A) are specifically designed to cool clean liquid before it is circulated to the cooling application. The Unit includes a complete refrigeration system and associated controls housed in a sturdy sheet metal enclosure with perforated panels for air circulation. Options include a reservoir and a choice of pumps and temperature controls to provide a self contained liquid cooling/circulation system tailored to a particular closed loop or tank cooling application. On closed loop systems, the Unit is provided with a pump and reservoir for recirculation of water from the chiller to the process. On tank cooling systems, the Unit is provided without the reservoir and the pump is optional for recirculation of water from the chiller to the tank. Control temperature is sensed on the outlet of the chiller for closed loop systems and it is sensed on the inlet of the chiller for tank cooling systems. The temperature control options consist of a general purpose digital thermostat and an electronic differential thermostat to satisfy the temperature control requirements. Both options include a digital thermometer for monitoring system temperature. The pump options consist of a small magnetic drive pump as standard with a variety of magnetic drive and positive displacement pumps available for particular flow and pressure requirements. An optional bypass valve is available for the pump circulation system. (This valve is standard on Units utilizing the positive displacement pumps). This can be used to adjust pump flow and pressure to match process requirements. This valve also allows internal recirculation within the chiller in the event the chiller outlet is obstructed. SPECIFICATIONS CH750 A CH751 A CH951 A Condensing Unit Horse Power 3/4 3/4 1 Electrical (Volts/Phase/Hz) 115/1/60 230/1/60 230/1/60 F.L.A. (Amps) 17 8.5 10 Reservoir Capacity (Gal) 5 5 5 Refrigerant 134 A Charge (Lbs) 3.5 3.5 4.0 Stainless Steel Connections 3/4 inch FPT 3/4 inch FPT 3/4 inch FPT Operating Water Temperature 40 F-100 F 40 F-100 F 40 F-100 F Range Net Weight (Lbs) 175 175 175 Dimensions Depth (inches) 24 1/2 24 1/2 24 1/2 Width (inches) 18 1/8 18 1/8 18 1/8 Height (inches) 30 1/2 30 1/2 30 1/2 1 91256

INSTALLATION INSTRUCTIONS LOCATION Locate the chiller indoors in a well ventilated area with ambient temperatures in the range of 65 F to 100 F. Allow a minimum of six inches of clearance around the chiller for proper air circulation. Avoid hot air discharge from other equipment or enclosed areas where heat could build up and cause a rise in ambient temperature. PLUMBING Follow standard plumbing practices and local codes in making water connections. Piping that is exposed to high ambient temperatures may need to be insulated to prevent condensation and/or significant liquid heat gain. ELECTRICAL All wiring must conform to the National Electric Code and any applicable local codes. The chiller must be: 1) Permanently wired by means of conduit from the junction box on the rear of the chiller cabinet to a properly fused disconnect of proper amperage or: 2) Wired to a properly rated power cord and plugged into an outlet with appropriate disconnect and amperage rating. START UP/OPERATION Before the Unit can be operated, it is important that the circulating system be filled with water (See Fluid Recommendations page). On systems with a reservoir, ensure that the drain plug is in place and the plug is secure. Fill the reservoir through the fill port with clean water. The water level sight glass on the front panel will indicate Full when enough water has been added. Once full, make the final connection to the inlet and outlet of the chiller. On system without a reservoir, the pump should be primed before operation. Attach a water source to the inlet of the chiller and fill the Unit with clean water. The system is filled when the water can be seen flowing at the chiller outlet. Once full, make the final connection to the inlet of the chiller. Turn the power switch to the On position. The switch will light indicating power to the Unit and the pump will operate, the thermostat can be adjusted to the proper setpoint. Set the standard digital thermostat to the desired setpoint as follows: 1) Push the Set button located to the right of the digital display. The current setpoint will show on the display. 2) While the current setpoint is displayed, push the Up or Down buttons until the desired setpoint shows on the display. 3) Release all buttons. The display will show the system water temperature after a few seconds. The setpoint can be viewed at any time by merely pushing the Set button. If the Unit is provided with the electronic differential thermostat, the air probe will need to be located where ambient temperature is to be monitored. The setpoint will then be the temperature of the air probe. If this thermostat is provided with a digital display, the setpoint can be checked by pushing the Setpoint button located on the display. Releasing this button will display the system water temperature. When the flow rate to the process is critical, a flow meter and valve should be installed in the line in order to obtain the proper flow rate. 91256 2

Once these start up procedures are complete, the chiller is ready for standard operation. NOTE: 1) Never operate the chiller with enclosure panels removed. 2) Always use the illuminated switch to turn off the chiller when it is not being used. 3) Always ensure that all air inlets and outlets are free of obstructions. MAINTENANCE WARNING: Disconnect electrical power from the Unit before performing any of the following maintenance procedures. The chiller requires very little normal maintenance. The condenser fins should be cleaned by blowing compressed air through the condenser. from the fan side as required to prevent blockage of air flow by dirt and debris that may accumulate over time. The condenser fan motor should be lubricated every six months with a few drops of SAE 10 oil. The positive displacement pump motor should be lubricated with ten drops of SAE 20 oil once each year. The circulation system should be drained and flushed periodically to avoid build up and possible restriction of flow by contaminants. Following these simple procedures will ensure many trouble free hours of chiller operation. SERVICE Service of the chiller is limited to replacing the switch, the thermostat, the fan motor, and the pump. Charging and other refrigeration problems must be performed by a qualified refrigeration technician. REMOVING WRAPPER 1. Disconnect electrical power from the Unit. 2. Remove the seven screws from each side of the wrapper and the two screws that secure the wrapper to the front and back panels. Retain all hardware and lift the wrapper off the Unit. REPLACING SWITCH 1. Remove the wrapper as specified in REMOVING WRAPPER. 2. Remove the spade lugs from the existing switch and note connection points. 3. Remove the switch from the front panel. 4. Install the new switch in the front panel and connect the leads to the new switch. 5. Install the wrapper. REPLACING STANDARD THERMOSTAT 1. Remove the wrapper as specified in REMOVING WRAPPER. 2. Loosen the screw terminals securing the wires at the rear of the thermostat. Note connection points and remove the wires. 3. Remove the screw securing the mounting bracket to the back of the thermostat. 4. Remove the thermostat from the front panel. 3 91256

5. Install the new thermostat in the front panel and secure it with the mounting bracket. 6. Reconnect the wires at back of the thermostat. 7. Install the wrapper. REPLACING ELECTRONIC DIFFERENTIAL THERMOSTAT 1. Remove the wrapper as specified in REMOVING WRAPPER. 2. Remove the two screws securing the thermostat cover and remove the cover. 3. Loosen the screw terminals securing all wires to the thermostat. Note connection points and remove the wires. 4. If the Unit is provided with a digital display, the ribbon cable should be removed from the thermostat. The display can be replaced by depressing the plastic clips and removing it from the front panel. 5. Remove the two screws securing the thermostat to the fan shroud and remove the thermostat. 6. Secure new thermostat to the fan shroud, then re connect all wires and ribbon cable. Replace cover. 7. Install the wrapper. REPLACING FAN BLADE AND/OR MOTOR 1. Remove the wrapper as specified in REMOVING WRAPPER. 2. Remove the screws securing the fan guard to the fan shroud. 3. Remove the conduit connection at the back of the motor and disconnect the wire leads. 4. Remove the bolts securing the fan mounting bracket to the base and remove the fan/motor assembly. 5. Separate the fan blade from the motor and install the new blade or motor. 6. Re install the fan mounting bracket and fan guard. Re connect the wire leads and conduit connection. 7. Install the wrapper. REPLACING PUMP 1. Remove the wrapper as specified in REMOVING WRAPPER. 2. Remove the clamps and hoses from the suction and discharge of the pump. 3. Remove the screws securing the pump to the base. 4. Disconnect the wire leads from the pump motor and remove the pump. 5. Remove all fittings from the pump and install them on the new pump. 6. Install the pump and re connect wire leads and hoses. 7. Install the wrapper. 91256 4

FLUID RECOMMENDATION Remcor Chillers are designed to operate with water to provide maximum performance for temperatures of 40 F 100 F. Distilled Water De Ionized Water (1 5 MEG/OHMS) De Ionized Water (5+MEG/OHMS) Propylene Glycol (Lab & Industrial Grade) Lab & Industrial Grade Ethylene Glycol Mineral/Hydraulic Oils (Viscosity<50 Centistrokes) Ethylene Glycol (Commercial/Automotive Antifreeze) Acceptable Acceptable Acceptable with Stainless Steel & PVC only *No Copper or Brass Acceptable 30% Glycol/70% Water *For Applications with Temperatures below 40 F Acceptable 30% Glycol/70% Water *For Applications with Temperatures below 40 F Acceptable NOT Acceptable *Silicate Rust Inhibitors in Automotive/Commercial Antifreeze will damage pump seals and housing which lead to failure. Acidic/Basic Solutions Not Acceptable (Above 8/Below 6 PH) Mineral/Hydraulic Oils Not Acceptable (Viscosity>50 Centistrokes) For questions regarding special or other fluids contact IMI Cornelius Remcor at 800 551 4423. To Purchase Lab or Industrial Glycol contact: Hubbard Hall IMI Cornelius (800) 648 3412 Dow Therm SR1 available in 5 gallon (800) 551 4423 Part# 111521000 5 gallons 5 91256

TROUBLESHOOTING GUIDE CHILLER DOES NOT OPERATE NO CIRCULATION OF CHILLED WATER Trouble Probable Cause Remedy A. No power. A. Check fuse or circuit breaker. B. Loose or poor wire connection. B. Check wiring. Correct for loose or poor wire connection. C. Inoperable ON OFF switch. C. Replace ON OFF switch. D. Overload device open. D. Allow compressor to cool, then install new overload device; replace compressor if necessary. E. Inoperable relay. E. Replace relay. F. Low input voltage. F. Nominal voltage ± 10% is required. A. Vinyl tubing kinked. A. Check tubing and remove kinks. B. Low water level. B. Ensure that tank is full. C. Inoperable pump. C. Check for obstruction or binding impeller, replace pump and/or motor if necessary. INADEQUATE COOLING A. Condenser fins dirty. A. Blow dirt out of fins. B. Fan motor not operating freely. B. Lubricate and hand spin until fan rotates freely; replace fan blade and/or motor if necessary. C. Water not circulating C. See NO CIRCULATION OF CHILLED WATER. D. Low refrigerant level. D. Charge system with refrigerant. E. Inoperative temperature control. E. Replace thermostat. 6 91272

PARTS LIST FIGURE 1. CH750, CH751 AND CH951 EXPLODED VIEW Item No. Part No. Name 8 620603705 * Compressor (CH951) Relay 1 31934 Switch, Illuminated 9 * Capacitor 31935 Switch, Illuminated 2 32386 Thermostat, Eliwell No. EWPC902 3 620603708 Blade, Fan 4 620603711 Motor, Fan (CH550) 620603712 Motor, Fan (CH750) 620603713 Motor, Fan (CH551) 5 * Condenser 6 Not Used 7 620603701 Compressor (CH550) 620603702 Compressor (CH551) 620603703 Compressor (CH750) 620603704 Compressor (CH751) 10 61058, 61001 TXV CH750, CH751 61003 TXV CH951 11 60514 Sight Glass 12 60502 Control, Low Pressure 13 61002 Filter Drier 14 * Receiver 15 Not Used 16 * Pump, Circulating 17 32378 Transformer, Thermostat 18 * Evaporator Assembly *CONTACT THE SERVICE DEPARTMENT FOR THE APPROPRI- ATE PART NUMBERS 7 620909701

WARRANTY IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship under normal use and service. For a copy of the warranty applicable to your Cornelius, Remcor or Wilshire product, in your country, please write, fax or telephone the IMI Cornelius office nearest you. Please provide the equipment model number, serial number and the date of purchase. IMI Cornelius Offices AUSTRALIA P.O. 210, RIVERWOOD, NSW 2210, AUSTRALIA (61) 2 533 3122 FAX (61) 2 534 2166 AUSTRIA AM LANGEN FELDE 32 A-1222 VIENNA, AUSTRIA (43) 1 233 520 FAX (43) 1-2335-2930 BELGIUM BOSKAPELLEI 122 B-2930 BRAASCHAAT, BELGIUM (32) 3 664 0552 FAX (32) 3 665 2307 BRAZIL RUA ITAOCARA 97 TOMAS COELHO RIO DE JANEIRO, BRAZIL (55) 21 591 7150 FAX (55) 21 593 1829 ENGLAND TYTHING ROAD ALCESTER WARWICKSHIRE, B49 6 EU, ENGLAND (44) 789 763 101 FAX (44) 789 763 644 FRANCE 71 ROUTE DE ST. DENIS F-95170 DEUIL LA BARRE PARIS, FRANCE (33) 1 34 28 6200 FAX (33) 1 34 28 6201 GERMANY CARL LEVERKUS STRASSE 15 D-4018 LANGENFELD, GERMANY (49) 2173 7930 FAX (49) 2173 77 438 GREECE 488 MESSOGION AVENUE AGIA PARASKEVI 153 42 ATHENS, GREECE (30) 1 600 1073 FAX (30) 1 601 2491 HONG KONG 1104 TAIKOTSUI CENTRE 11-15 KOK CHEUNG ST TAIKOKTSUE, HONG KONG (852) 789 9882 FAX (852) 391 6222 ITALY VIA PELLIZZARI 11 1-20059 VIMARCATE, ITALY (39) 39 608 0817 FAX (39) 39 608 0814 NEW ZEALAND 20 LANSFORD CRES. P.O. BOX 19-044 AVONDALE AUCKLAND 7, NEW ZEALAND (64) 9 8200 357 FAX (64) 9 8200 361 SINGAPORE 16 TUAS STREET SINGAPORE 2263 (65) 862 5542 FAX (65) 862 5604 SPAIN POLIGONO INDUSTRAIL RIERA DEL FONOLLAR E-08830 SANT BOI DE LLOBREGAT BARCELONA, SPAIN (34) 3 640 2839 FAX (34) 3 654 3379 USA ONE CORNELIUS PLACE ANOKA, MINNESOTA (763) 421-6120 FAX (763) 422-3255 LD004 4/21/98 91272 8

CORPORATE HEADQUARTERS: Remcor Incorporated 500 Regency Drive Glendale Heights, IL 60139