CH750, CH751 & CH951 CHILLERS

Similar documents
CHILLERS. Operator s & Installation Manual

CH250 AND CH251 CHILLERS

CFF-500 CHILLER. Operator s & Installation Manual. Release Date: November 3, 1996 Publication Number: Revision Date: March 25, 2014 Revision: F

CHILLER. Model CH3000. Operator s & Installation Manual

CHILLER MODEL: CH1500, 2000 AND 3000

Operator s Manual CHILLER ( CH SERIES) Models: CH750, CH751, and CH951

CHILLER. Operator s & Installation Manual

Operator s Manual CHILLER ( CH SERIES) Models: CH750, CH751, and CH951

Operator s Manual CHILLER ( CHILLER SERIES) Models: CH550 and CH 551

CHILLER. Operator s & Installation Manual

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250

ABS HOPPER LID SWITCH KIT ASSEMBLY

ICE DISPENSER. D45 and D90 Installation Manual. Release Date: August, 1995 Publication Number: Revision Date: March 27, 2014 Revision: D

VISUAL DISPLAY DISPENSER OWNERS MANUAL

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO VALVE

COMPRESSOR SERVICE REPLACEMENT KIT P/N (WCC 500A, 115/60, AIR COOLED)

VANTAGE. Installation Manual. Release Date: April 16, 2003 Publication Number: INS Revision Date: January 22, 2015 Revision: E

ICE COOLED DISPENSER ALTA 1522 DROP-IN DISPENSER

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

ED200/250 KSTYLE LID KITS

ICE/BEVERAGE DISPENSER MODELS: ENDURO-150 (SIX VALVE) INSTALLATION MANUAL

IMI CORNELIUS CHILLER

STARBUCKS UC100 PROGATE

CONTINUOUS FLOW ICEMAKER

ICE/BEVERAGE DISPENSER

ICE/BEVERAGE DISPENSER

OPERATOR S MANUAL ICE/BEVERAGE DISPENSER. Model: Enduro Valve

Surna 25-Ton Chiller Operating & Maintenance Manual

Owner / Operator Use and Care Guide I SERIES 224 ICE CUBE MACHINE

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Installation, Operation and Maintenance Manual

Henny Penny Blast Chiller/Freezer Models BCC/BCR-140 Models BCC/BCR-175 Models BFR/BCR-350

QUANTUM SERIES Installation and Service Manual

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

ILLUSTRATED PARTS LIST ENDURO VALVE

Power Pack Service Manual

Power Pack Service Manual

JetSpray Visual Display Dispenser JT20C

MACH N-407 Heat Pump Air-Cooled Chiller

REMOTE COOLER AIR COOLED & WATER COOLED

INSTALLATION MANUAL. Series 322 Ice Cube Machine SPECIFICATIONS UNPACKING. Series 322 Ice Cube Machine Installation Instructions

Installation Manual CARBONATOR With Plain-Water Booster

HX-1000 & HX-2000 Recirculating Chiller. NESLAB Manual P/N Rev 03/19/97. Instruction and Site Preparation Manual

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

Installation Operation Maintenance

COLMAC COIL. Installation, Operation, and Maintenance ENG Rev A. Air Cooled Fluid Coolers. Contents. When you want Quality, specify COLMAC!

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

MAC N-407 Air-Cooled Chiller

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

PDF Created with deskpdf PDF Writer - Trial ::

Power Pack Service Manual

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

POWER PACK SERVICE MANUAL

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual

POWER PACK SERVICE MANUAL

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

OPERATING AND INSTALLATION MANUAL

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

Bulletin (Jan 2011) And User s Guide

FTC-350A. ual. Instruction and Operation Manual. Thermo NESLAB Manual P/N Rev. 11/08/00

KODIAK RECIRCULATING CHILLERS TECHNICAL MANUAL RC006, RC009, RC011, RC022, RC030 and RC045 G03, H03 and J03 Series

Introduction... 1 System Overview... 1 System Diagram... 2

Glass Door Merchandiser. Model RM-49

INSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

HT650 TM FAN DRIVE SERVICE INSTRUCTIONS

Hoshizaki America, Inc.

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

FCB PINNACLE. Operator s Manual. 2 and 4 Flavor

Prime Chiller Mini-Chillers

Prime Chiller 1/10th HP Chiller

Prime chiller. Inline Chiller. Instructions for Models #2645,2646

T-Series Air Conditioner T15 Model

OPERATING AND INSTALLATION MANUAL

T-Series Air Conditioner T20 Model

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

STEAMPRO. Steam Generator Troubleshooting and Service Guide

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

Rev B, 9/2/2009. Kodiak Chiller Overview

EXC-450 User s Manual

LC Series - Light Commercial Pump Station Installation and Operation Manual

Panel Fan Series Operators Manual (Galvanized and Polymer)

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Prime Chiller Modular Upgradable Chiller

XD-125 OWNER S MANUAL COMMERCIAL DEHUMIDIFIER

Next Generation Corona Discharge Installation & Operation Manual

VIPER. Operator s Manual. Release Date: October 11, 2008 Publication Number: OPR Revision Date: May 19, 2009 Revision: Preliminary B

MODELS B1PA024, 030 AND 036

DR Series. Installation & Operations Manual. Model: DR-10 HIGH OUTPUT SHOCK TREATMENT OZONE GENERATOR

Transcription:

CH750, CH751 & CH951 CHILLERS Operator s & Installation Manual Release Date: April 19, 2002 Publication Number: 91256 Revision Date: March 25, 2014 Revision: F Visit the Cornelius web site at www.cornelius.com for all your Literature needs.

The products, technical information, and instructions contained in this manual are subject to change without notice. These instructions are not intended to cover all details or variations of the equipment, nor to provide for every possible contingency in the installation, operation or maintenance of this equipment. This manual assumes that the person(s) working on the equipment have been trained and are skilled in working with electrical, plumbing, pneumatic, and mechanical equipment. It is assumed that appropriate safety precautions are taken and that all local safety and construction requirements are being met, in addition to the information contained in this manual. This Product is warranted only as provided in Cornelius Commercial Warrant applicable to this Product and is subject to all of the restrictions and limitations contained in the Commercial Warranty. Cornelius will not be responsible for any repair, replacement or other service required by or loss or damage resulting from any of the following occurrences, including but not limited to, (1) other than normal and proper use and normal service conditions with respect to the Product, (2) improper voltage, (3) inadequate wiring, (4) abuse, (5) accident, (6) alteration, (7) misuse, (8) neglect, (9) unauthorized repair or the failure to utilize suitably qualified and trained persons to perform service and/or repair of the Product, (10) improper cleaning, (11) failure to follow installation, operating, cleaning or maintenance instructions, (12) use of non-authorized parts (i.e., parts that are not 100% compatible with the Product) which use voids the entire warranty, (13) Product parts in contact with water or the product dispensed which are adversely impacted by changes in liquid scale or chemical composition. Contact Information: To inquire about current revisions of this and other documentation or for assistance with any Cornelius product contact: www.cornelius-usa.com 800-238-3600 Trademarks and Copyrights: This document contains proprietary information and it may not be reproduced in any way without permission from Cornelius. This document contains the original instructions for the unit described. CORNELIUS INC 101 Regency Drive Glendale Heights, IL Tel: + 1 800-238-3600 Printed in U.S.A.

TABLE OF CONTENTS Safety Instructions................................................................. 1 Read and Follow ALL Safety Instructions............................................. 1 Safety Overview.............................................................. 1 Recognition................................................................. 1 Different Types of Alerts.......................................................... 1 Safety Tips..................................................................... 1 Qualified Service Personnel........................................................ 1 Safety Precautions............................................................... 2 Shipping And Storage............................................................ 2 Introduction...................................................................... 3 Specifications................................................................... 3 Installation Instructions............................................................ 4 Location....................................................................... 4 Plumbing...................................................................... 4 Electrical...................................................................... 4 Start-Up/Operation................................................................. 5 Standard Thermostat Eliwell IC902.................................................. 5 Maintenance...................................................................... 6 Service.......................................................................... 7 Removing Wrapper.............................................................. 7 Replacing Switch................................................................ 7 Replacing Fan Blade and/or Motor.................................................. 7 Replacing Pump................................................................. 7 Fluid Recommendations............................................................ 8 Troubleshooting................................................................... 9 Parts List........................................................................ 10

SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS Safety Overview Read and follow ALL SAFETY INSTRUCTIONS in this manual and any warning/caution labels on the unit (decals, labels or laminated cards). Read and understand ALL applicable OSHA (Occupational Safety and Health Administration) safety regulations before operating this unit. Recognition DIFFERENT TYPES OF ALERTS Recognize Safety Alerts! DANGER: Indicates an immediate hazardous situation which if not avoided WILL result in serious injury, death or equipment damage.! This is the safety alert symbol. When you see it in this manual or on the unit, be alert to the potential of personal injury or damage to the unit.! WARNING: Indicates a potentially hazardous situation which, if not avoided, COULD result in serious injury, death, or equipment damage.! CAUTION: Indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury or equipment damage. SAFETY TIPS Carefully read and follow all safety messages in this manual and safety signs on the unit. Keep safety signs in good condition and replace missing or damaged items. Learn how to operate the unit and how to use the controls properly. Do not let anyone operate the unit without proper training. This appliance is not intended for use by very young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the appliance. Keep your unit in proper working condition and do not allow unauthorized modifications to the unit. QUALIFIED SERVICE PERSONNEL! WARNING: Only trained and certified electrical, plumbing and refrigeration technicians should service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL CODES. FAILURE TO COMPLY COULD RESULT IN SERIOUS INJURY, DEATH OR EQUIPMENT DAMAGE. 2002-2014, Cornelius Inc. - 1 - Publication Number: 91256

SAFETY PRECAUTIONS This unit has been specifically designed to provide protection against personal injury. To ensure continued protection observe the following:! WARNING: Disconnect power to the unit before servicing following all lock out/tag out procedures established by the user. Verify all of the power is off to the unit before any work is performed. Failure to disconnect the power could result in serious injury, death or equipment damage.! CAUTION: Always be sure to keep area around the unit clean and free of clutter. Failure to keep this area clean may result in injury or equipment damage. SHIPPING AND STORAGE! CAUTION: Before shipping, storing, or relocating the unit, the unit must be sanitized and all sanitizing solution must be drained from the system. A freezing ambient environment will cause residual sanitizing solution or water remaining inside the unit to freeze resulting in damage to internal components. Publication Number: 91256-2 - 2002-2014, Cornelius Inc.

INTRODUCTION The Cornelius CH Series Water Chillers (Models CH750-A, CH751-A, and CH951-A) are specifically designed to cool clean liquid before it is circulated to the cooling application. The Unit includes a complete refrigeration system and associated controls housed in a sturdy sheet metal enclosure with perforated panels for air circulation. Options include a reservoir and a choice of pumps and temperature controls to provide a self-contained liquid cooling/circulation system tailored to a particular closed loop or tank cooling application. On closed loop systems, the Unit is provided with a pump and reservoir for recirculation of water from the chiller to the process. On tank cooling systems, the Unit is provided without the reservoir and the pump is optional for recirculation of water from the chiller to the tank. Control temperature is sensed on the outlet of the chiller for closed loop systems and it is sensed on the inlet of the chiller for tank cooling systems. The pump options consist of a small magnetic drive pump as standard with a variety of magnetic drive and positive displacement pumps available for particular flow and pressure requirements. An optional bypass valve is available for the pump circulation system. (This valve is standard on Units utilizing the positive displacement pumps). This can be used to adjust pump flow and pressure to match process requirements. This valve also allows internal recirculation within the chiller in the event the chiller outlet is obstructed. SPECIFICATIONS CH750-A CH751-A CH951-A Condensing Unit Horse Power 3/4 3/4 1 Electrical (Volts/Phase/Hz) 115/1/60 230/1/60 230/1/60 F. L. A. (Amps) 19 9.5 10 Reservoir Capacity (Gal) 5 5 5 Refrigerant 134-A Charge (Lbs) 3.5 3.5 4.0 Stainless Steel Connections 3/4-inch FPT 3/4-inch FPT 3/4-inch FPT Operating Water Temp. Range 40-100 o F 40-100 o F 40-100 o F Net Weight (Lbs.) 250 250 250 Dimensions:Depth (inches) Width (inches) Height (inches) 24-1/2 18-1/8 30-1/2 24-1/2 18-1/8 30-1/2 24-1/2 18-1/8 30-1/2 2002-2014, Cornelius Inc. - 3 - Publication Number: 91256

LOCATION INSTALLATION INSTRUCTIONS Locate the chiller indoors in a well ventilated area with ambient temperatures in the range of 65 F to 100 F. Allow a minimum of six inches of clearance around the chiller for proper air circulation. Avoid hot air discharge from other equipment or enclosed areas where heat could build up and cause a rise in ambient temperature. PLUMBING Follow standard plumbing practices and local codes in making water connections. Piping that is exposed to high ambient temperatures may need to be insulated to prevent condensation and/or significant liquid heat gain. ELECTRICAL All wiring must conform to the National Electric Code and any applicable local codes. The chiller must be: 1. Permanently wired by means of conduit from the junction box on the rear of the chiller cabinet to a properly fused disconnect of proper amperage or; 2. Wired to a properly rated power cord and plugged into an outlet with appropriate disconnect and amperage rating. Publication Number: 91256-4 - 2002-2014, Cornelius Inc.

START-UP/OPERATION Before the Unit can be operated, it is important that the circulating system be filled with water (See Fluid Recommendations page). On systems with a reservoir, ensure that the drain plug is in place and the plug is secure. Fill the reservoir through the fill port with clean water. The water level sight glass on the front panel will indicate Full when enough water has been added. Once full, make the final connection to the inlet and outlet of the chiller. On system without a reservoir, the pump should be primed before operation. Attach a water source to the inlet of the chiller and fill the Unit with clean water. The system is filled when the water can be seen flowing at the chiller outlet. Once full, make the final connection to the inlet of the chiller. Turn the power switch to the On position. The switch will light indicating power to the Unit and the pump operates, the thermostat can be adjusted to the proper setpoint. STANDARD THERMOSTAT ELIWELL IC902 The following procedure should be followed to adjust the Eliwell IC902 thermostat temperature setting: 1. To set the SET POINT, press and release the SET button. SET displays. 2. Press the SET button again, the current SET POINT is displayed. Press the UP or DOWN button to change the SET POINT to the desired temperature. 3. Press the fnc button twice to exit the program. The current liquid temperature is displayed. The thermostat has a range that is pre-set at the factory. The range is 40 F (5 C) to 100 F (38 C). If operation outside of this range is required, please contact the Cornelius Technical Service Department. out1 o F fnc set Figure 1. Control Panel When the flow rate to the process is critical, a flow meter and valve should be installed in the line in order to obtain the proper flow rate. Once these start-up procedures are complete, the chiller is ready for standard operation. NOTE: Never operate the chiller with enclosure panels removed. Always use the illuminated switch to turn off the chiller when it is not being used. Always ensure that all air inlets and outlets are free of obstructions. 2002-2014, Cornelius Inc. - 5 - Publication Number: 91256

MAINTENANCE! WARNING: Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all power is off to the unit before performing any work. Failure to comply could result in serious injury, death or damage to the equipment. The chiller requires very little normal maintenance. The condenser fins should be cleaned by blowing compressed air through the condenser. from the fan side as required to prevent blockage of air flow by dirt and debris that may accumulate over time. The positive displacement pump motor should be lubricated with ten drops of SAE 10 oil once each year. The circulation system should be drained and flushed periodically to avoid build up and possible restriction of flow by contaminants. Following these simple procedures will ensure many trouble free hours of chiller operation. Publication Number: 91256-6 - 2002-2014, Cornelius Inc.

SERVICE! WARNING: Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all power is off to the unit before performing any work. Failure to comply could result in serious injury, death or damage to the equipment. Service of the chiller is limited to replacing the switch, the thermostat, the fan motor, and the pump. Charging and other refrigeration problems must be performed by a qualified refrigeration technician. REMOVING WRAPPER 1. Disconnect electrical power from the Unit. 2. Remove the seven screws from each side of the wrapper and the two screws that secure the wrapper to the front and back panels. Retain all hardware and lift the wrapper off the Unit. REPLACING SWITCH 1. Remove the wrapper as described above. 2. Remove the spade lugs from the existing switch and note connection points. 3. Remove the switch from the front panel. 4. Install the new switch in the front panel and connect the leads to the new switch. 5. Install the wrapper. REPLACING FAN BLADE AND/OR MOTOR 1. Remove the wrapper as described above. 2. Remove the screws securing the fan guard to the fan shroud. 3. Remove the conduit connection at the back of the motor and disconnect the wire leads. 4. Remove the bolts securing the fan mounting bracket to the base and remove the fan/motor assembly. 5. Separate the fan blade from the motor and install the new blade or motor. 6. Re-install the fan mounting bracket and fan guard. Re-connect the wire leads and conduit connection. 7. Install the wrapper. REPLACING PUMP 1. Remove the wrapper as described above. 2. Remove the clamps and hoses from the suction and discharge of the pump. 3. Remove the screws securing the pump to the base. 4. Disconnect the wire leads from the pump motor and remove the pump. 5. Remove all fittings from the pump and install them on the new pump. 6. Install the pump and re-connect wire leads and hoses. 7. Install the wrapper. 2002-2014, Cornelius Inc. - 7 - Publication Number: 91256

FLUID RECOMMENDATIONS Cornelius chillers are designed to operate with water to provide maximum performance for temperatures of 40 F (4.4 C) to 100 F (37.8 C). Distilled Water De-Ionized Water (1-5 Meg ohms) De-Ionized Water (5+ Meg ohms) Propylene Glycol (Lab & Industrial Grade) Lab & Industrial Grade Ethylene Glycol Mineral/Hydraulic Oils (Commercial/Automotive Antifreeze) Acidic/Basic Solutions (Above 8 or below 6 PH) Mineral/Hydraulic Oils (Viscosity > 50 Centistrokes) Acceptable Acceptable Acceptable with Stainless Steel & PVC only (No Copper or Brass) Acceptable - 30% Glycol/70% Water (For Applications with Temperatures below 40 F) Acceptable - 30% Glycol/70% Water (For Applications with Temperatures below 40 F) For questions regarding special or other fluids contact Cornelius at 1-800-551-4423. To purchase Lab or Industrial Glycol contact: Cornelius, 1-800-551-4423 - Part No. 111521000, 5 Gal. NOT Acceptable (Silicate Rust Inhibitors in Automotive/Commercial antifreeze damages pump seals and housing which lead to failure.) Not Acceptable Not Acceptable Publication Number: 91256-8 - 2002-2014, Cornelius Inc.

TROUBLESHOOTING! WARNING: Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all power is off to the unit before performing any work. Failure to comply could result in serious injury, death or damage to the equipment. Trouble Problem Cause Remedy Chiller does not operate, Power Light OFF No Circulation of Chilled Water Inadequate Cooling A. No Power to unit B. Loose or poor wire connection C. Defective Control Power Switch D. Overload device open. E. Inoperable relay. F. Low input voltage A. Line to or from chiller is restricted. B. Low water level. C. Inoperable pump. A. Condenser is restricted. B. Fan motor not operating freely. C. Water not circulating D. Unit low on refrigerant. E. Inoperative temperature control. A. Check main disconnect fuses, wiring and power lead to unit. B. Check wiring. Correct loose or poor wire connection C. Replace Switch D. Allow compressor to cool, then install new overload device; replace compressor if necessary. E. Replace relay. F. Nominal voltage +/- 10% is required. A. Inspect lines and remove any obstructions. B. Ensure that tank is full. C. Check for obstruction or binding impeller., replace pump and/or motor, if necessary. A. Clean condenser. B. Replace fan blade and/or motor if necessary. C. See No Circulation of Chilled Water D. Charge system with refrigerant. E. Replace thermostat. 2002-2014, Cornelius Inc. - 9 - Publication Number: 91256

CH1001-A Chiller Operator s & Installation Manual PARTS LIST Figure 2. CH750, CH751 and CH951 Exploded View Item No. Part No. Table 1. Description 1 31934 Switch, Illuminated (115V) 31935 Switch, Illuminated (230V) 2 32386 Thermostat, Eliwell No. EWPC902 3 620603707 Blade, Fan (CH750, CH751) 62063706 Blade, Fan (CH951) 620603711 Motor, Fan (CH750) 4 620603712 Motor, Fan (CH751) 620603713 Motor, Fan (CH951) 5 * Condenser 6 Not Used 620603703 Compressor (CH750) 7 620603704 Compressor (CH751) 620603705 Compressor (CH951) 8 * Relay 9 * Capacitor Table 1. Item No. Part No. Description 10 61001 TXV CH750, CH751 61003 TXV CH951 11 60514 Sight Glass 12 60502 Control, Low Pressure 13 60204 Filter Drier 14 * Receiver 15 Not Used 16 * Pump, Circulating 17 32378 Transformer, Thermostat 18 32606 Relay (115V) 32607 Relay (230V) * Contact the Service Dept. for the Appropriate Part Numbers. Publication Number: M620919596OPR - 10-2004-2014, Cornelius Inc.

Cornelius Inc. www.cornelius.com