WET POSITION BOOSTER FANS FOR REDUCED POWER CONSUMPTION AND OPTIMIZED ENVIRONMENTAL PERFORMANCE OF POWER STATIONS WITH FGD AND WET STACK

Similar documents
Figure 1: Overview of Rovinari Power Station FGD project planned situation.

Lignite fired power station in Romania fits FGD with Wet Booster Fans and Pennguard lined Concrete Chimneys for maximum Efficiency

Sludge Dryer Wet Scrubber Used to Produce Renewable Energy

Mist eliminators for Flue Gas Desulphurization

Mixing Technologies Solutions for Flue Gas Desulfurization

TEPZZ 87_ 6A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION

M I S T E L I M I N AT I O N. Mist elimination in Flue Gas Desulphurization. The buck stops here.

AUTOMATION OF BOILERS USING LABVIEW

Study and Design Considerations of HRSG Evaporators in Fast Start Combined Cycle Plants. Govind Rengarajan, P.E.CEM, Dan Taylor

A STUDY ON THE BEHAVIOR OF STEAM CONDENSATION IN U-SHAPED HEAT TUBE

Heat pump supplemental heating system for motor vehicles

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants

New standard in compressed air treatment, providing Energy Savings up to 99%

Boiler Draft Equipment

NOx REDUCTION EXPERIENCE ON NATURAL GAS FIRED TURBO FURNACES

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Forced Draft Boiler Flue Gas Venting: Problems & Solutions. Presented by Steve Connor and Patrice Gouin January 27, 2016

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

HumidiPack,HumidiPackPlus and HumidiPackPlus CF Steam Humidifier Systems

Passive cooling of telecommunication outdoor cabinets for mobile base station

OPTIMIZING PERFORMANCE IN SPRAY OPERATIONS

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Desiccant Cooling with Solar Energy

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

MEGA 2010 Advances in Hot Side SO3 Mitigation Technology

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

Homework Chapter2. Homework Chapter3

HUMIDITY MEASUREMENT BENEFITS IN POWER PLANT APPLICATIONS. Jeff Bossong, H 2 O

PERFORMANCE OF A MODEL IN-LINE VORTEX SEPARATOR. Keng-Choon Lee Geothermal Institute, The University of Auckland, Private Bag 92019, Auckland, New

Moisture can be very disruptive to a dust. Preventing moisture problems in your dust collector

TESTS OF ADSIL COATING

Owner s Manual for. PennStoker

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

Dynamic performance of a novel dew point air conditioning for the UK buildings

1.1. SCOPE OF THE WORK:

Figure 1: Overview of CO 2 evaporator types

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger

EVALUATION OF A LIQUID DESICCANT AIR CONDITIONING SYSTEM WITH SOLAR THERMAL REGENERATION

LOW-NOX BURNER RETROFIT CHALLENGE

Liquid Desiccant Technology Delivers Energy Cost Reductions and Indoor Air Quality Improvements. White Paper

Development of Boiler Design

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

Challenges and Methods of Estimating a Conceptual HVAC Design

FAN SEPARATOR. Fan / Separator H2SO4 (Sulfuric Acid) is Designed to Remove Fume and Other Contaminants from the Air Stream.

Condensation. Some causes, some advice. GGF Condensation Brochure_web.indd 1

Installation of a Brunner fireplace. General Indications

Boiler Basics. Design and operation

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Insty-Pac Steam Humidifiers

Efficiency of Application the Condensing Heat Utilizers in the Existing Boiler's Unit in Heat Power Station

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM

Australian Solar Cooling Interest Group (ausscig) Conference

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

Eliminating Condensation and Resulting Corrosion. Sulphur Tail Gas and De-Gas Lines

Effects of Ultra-High Turndown in Hydronic Boilers By Sean Lobdell and Brian Huibregtse January 2014

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

White Paper Dehumidification in Humid Climates - A Theoretical Case Study

Jet ejectors for the oil industries. Vacuum solutions for refineries and the petrochemical industries

Temperature Distribution of Rotary Heat Recovery Units

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Enviro International Corporation. WET SCRUBBER

Impacts of Optimized Cold & Hot Deck Reset Schedules on Dual Duct VAV Systems - Theory and Model Simulation

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Optimization of Hybrid Noncondensable Gas Removal System for a Flash Steam Geothermal Power Plant

Reducing energy use, airstream heat gain, and condensate production

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

Numerical study of heat pipe application in heat recovery systems

OIL AND GAS INDUSTRY

SIR C.R.REDDY COLLEGE OF ENGINEERING, ELURU DEPARTMENT OF MECHANICAL ENGINEERING ETD-II. Model Short Answer Questions And Answers

Performance Optimization of the Evaporative Condenser Design

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

How to improve air cooler vacuum steam condensers performance in the field

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

An experimental study of the impact of tunnel suppression on tunnel ventilation

A CEILING CONDENSING UNIT WITH PELTIER ELEMENTS FOR DRYING AND COOLING

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

The Role of Air Handling Units in Combating the Spread of Infectious Disease

ecodry Figure 1 - Process Diagram ecodry B General Process Description

Shortcut Model for Predicting Refrigeration Cycle Performance

IntrCooll. Cool large buildings at 80% lower running costs

Ultra Efficient Desiccant Based Evaporative Cooling for Air- Conditioning

SECTION AIR COILS

Proceedings Design, Fabrication and Optimization of a Silicon MEMS Natural Gas Sensor

Appendix 13. Categories of Cooling and Heating systems

Technical Information

HEAT REGENERATED ADSORPTION DRYERS

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Natatorium Economizer Vs. Conventional Dehumidifier

FIELD OF OPERATION. Multi cyclones Bag filter Flue gas fan Rotary locks Conveying systems Accessories for dust collection plants

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV

Impact of indirect evaporative air cooler type on the performance of desiccant systems

Management of In-Bin Natural Air Grain Drying Systems to Minimize Energy Cost

CTI Sponsored Educational Program

DROP-IN EVALUATION OF REFRIGERANT 1234YF IN A RESIDENTIAL INTEGRAL HEAT PUMP WATER HEATER

Single-Felt Dryer Sections

Transcription:

WET POSITION BOOSTER FANS FOR REDUCED POWER CONSUMPTION AND OPTIMIZED ENVIRONMENTAL PERFORMANCE OF POWER STATIONS WITH FGD AND WET STACK Authors: Lewis Maroti and David Anderson Alden Research Laboratory, Inc. Albert de Kreij Hadek Protective Systems bv.

Abstract This paper is related to the wet limestone FGD retrofit to four 340 MW lignite fired units at the Rovinari Power Station in Romania. The paper focuses on the technical, economical and environmental aspects of the wet booster fans, FGD outlet ductwork and the FGD wet stacks. The paper will present results of the technical and economical evaluation that resulted in the decision by the owner and its EPC contactor Alstom Power to place booster fans in the wet position downstream of the FGD absorbers. The paper will also discuss the evaluation for the design of the flue gas path using both physical flow testing and computational analysis, to reach the most desirable and economical design of ducts downstream of the absorber and the booster fan location. The investigation concluded that this new setup of wet fans in conjunction with the use of a chimney design using an insulating borosilicate glass block lining, directly installed to the windshield results in an optimized design for wet flue gas evacuation. The design reduces condensate formation resulting in an environmentally optimized operation, while also increasing overall efficiency of the power station.

1. Introduction ALSTOM Power Italia has been contracted to design and build wet FGD for the Rovinari 4 x 330 MW lignite fired power station in Romania. In order to minimize the running cost of the FGD system, the booster fans will be placed in the "wet position" (i.e. between the wet FGD scrubber and the wet stack), where they will consume significantly less power. Alden Research Laboratory has investigated the combined environmental effect of the wet booster fans and the thermally insulated, Pennguard lined wet stacks, taking into account that the wet booster fans will impart a small temperature increase on the treated flue gas stream. 2. Executive summary The FGD booster fans for the 330 MW lignite fired units at Rovinari Power Station will be placed in the wet position (i.e. between the wet FGD scrubber and the wet stack), where they will consume significantly less power than in the more common "dry position" (i.e. in the hot, dry flue gas upstream of the FGD scrubber). In order to function well in the environment of desulfurized, water saturated flue gas, the booster fans are fabricated from corrosion resistant materials and cleaned during operation through a regular wash cycle. Alden Research Laboratory has performed a study into the environmental benefits of using wet booster fans, considering that these heat up the treated flue gas by 3 to 5 degrees C. The study included both thermodynamic calculations and physical tests using a laboratory scale model. The study showed that, at nominal unit load, (a) the booster fans will have the capacity to evaporate small diameter droplets contained in the wet gas including all of the water from the fan wash cycle and (b) raise the flue gas temperature sufficiently to enable the thermally insulated, Pennguard lined chimneys to maintain the flue gas temperature just above the water dewpoint, effectively eliminating condensate formation in the wet stacks. A properly designed liquid collection system in the outlet ducts and the chimney breeching will still be needed, to collect bigger droplets that may not have enough time to evaporate.

3. Overview of Rovinari Power Station FGD project The Rovinari Power Station has four, 330 MW lignite fired boilers, constructed in the period between 1976 and 1979. The units fire a local lignite coal with a sulfur content that ranges between 0.5 and 1.35 %. Following the accession of Romania into the European Union, Rovinari Power Station will have to meet the EU emission limit for SOx of 400 mg/nm3 dry 6%O2. To achieve this limit ALSTOM will retrofit separate wet limestone FGD systems to Unit 3 (2009) and Unit 6 (2010), possibly followed by Unit 4 (2011) and Unit 5 (2013) (Figure 1). Figure 1: Overview of Rovinari Power Station FGD project planned situation. For each of the four units, the gas flow volume (at nominal load, in Nm3/h, wet) will be over 2,000,000 cubic meters per hour. Following treatment in the FGD absorber, the flue gas stream enters the FGD outlet duct at a temperature of 61 C and saturated with water. In order to minimize the droplet content of the flue gas entering the FGD outlet duct, the absorbers are equipped with two stages of mist eliminators, placed in series.

4. Economic considerations related to location of the booster fans For most FGD plants constructed worldwide in recent decades, the location of choice for the booster fans has been upstream of the FGD scrubbers, in a high temperature non-saturated gas stream. The obvious advantage is, that the booster fans can be constructed of mild steel or a Corten type steel, keeping the cost of the booster fan itself low. However, the disadvantage is that at temperatures of 120-150 C, the gas stream has a high volume and lower density, significantly increasing the energy consumption of the booster fans. In recent years, the cost of energy has increased strongly and consequently, power plant owners are motivated to look for ways to minimize the energy consumption of the generating plant itself, maximizing the electricity output available for delivery to the grid. At the same time, the technology of corrosion resistant materials and of booster fan design has been developed to a level, where booster fans can reliably be used in the wet corrosive gas stream (Figure 2). To avoid ash or gypsum buildup on the fan blades, special spray systems and wash cycles have been developed that keep the fan blades clean during operation. Considering the need for maximum net power production and the availability of modern booster fan technology, the designers of the Rovinari FGD system found that the use of wet booster fans was highly desirable, significantly reducing the estimated power consumption per booster fan. Figure 2: Location of the wet booster fan.

5. Effect of axial flow type wet booster fan on flue gas conditions The main objective of any booster fan is to increase flue gas pressure to promote its flow through the ducts and to the top of the chimney. Due to the compression effect and to fan inefficiency, a booster fan will slightly warm the flue gas as it passes through the fan. In the case of the Rovinari booster fans, the fan supplier has specified a temperature rise of 5.5 C at nominal load and 3.0 C at minimum load. In a water saturated gas flow, as seen in an FGD system without reheat, this slight warm-up of the flue gas stream could be very significant as it would lift the flue gas temperature above its water dewpoint, potentially eliminating the constant formation of flue gas condensate in the flue gas ductwork and the wet stack. As such, the use of wet booster fans could be an important tool in reducing the risk of liquid carryover from wet stacks. The flue gas from the Rovinari FGD scrubbers is 61 C and water saturated. It will also contain up to 50 mg/nm3 of fine droplets, even after passing through the mist eliminators. To evaluate the effects of the flue gas temperature rise by the booster fan, the evaporation of the 50mg/Nm3 liquid load must be considered. In addition, the wet booster fans have a 2-minute wash cycle running 12 times per hour, during which water is injected at a rate of 400 liters per hour. The evaporation and flow of this washing water downstream of the fan also has to be considered. Based on a set of thermodynamic calculations, Alden Research Laboratory concluded that at nominal load, the temperature rise in the wet booster fans should be sufficient to (a) evaporate the 50 mg/nm3 of droplets in the gas flow, (b) evaporate the washing water from the wash cycle while at the same time (c) raising the gas flow temperature 1.95 C above its water dewpoint. During the minimum load case, assuming the same volume of water in the fan wash cycle, the heat added to the gas flow by the wet booster fans would not be sufficient to both evaporate all droplets in the flue gas and raise the temperature of the gas stream above its water dewpoint. In addition to the above findings, which are based on the energy balance of the total gas stream, Alden concluded that for a portion of the droplets from the fan wash cycle, the residence time in the outlet duct would be too short for these droplets to evaporate before the chimney breeching. On the one hand, this is a positive because this leaves more heat in the flue gas to warm up above its dewpoint. On the other hand, the presence of un-evaporated droplets in the chimney breeching creates the need for liquid collectors and sumps in the lower zone of the breeching and lower zone of the stack. Moreover local, unpredictable cold points (i.e. expansion joints) may result in localized condensate formation, further confirming the need for a liquid collection system.

6. Design of the Rovinari wet stacks Each of the new FGD systems at the Rovinari Power Station will be equipped with its own free standing, 120 m high, 7 m diameter chimney. These chimneys have been designed in accordance with the New Chimney Design (Figure 3), as developed by Hadek Protective Systems bv. They consist of a 120 m high concrete shell, protected internally by a 41 mm thick Pennguard Block Lining System applied directly to the concrete shell. The New Chimney Design does not use any internal flue, which allows it to be relatively slender and which also keeps construction cost and construction time to a minimum. The Pennguard Block, a closed cell borosilicate glass block, is the main component of the Pennguard Block Lining System and it has a thermal conductivity of 0.087 W/m. K at a mean temperature of 38 C. As a result, Pennguard lined chimneys are well insulated and the temperature losses of a flue gas stream flowing from the bottom to the top of these chimneys will be low. Figure 3: The Rovinari wet stacks have been designed in accordance with the New Chimney Design. The Pennguard lining will be applied directly to the concrete shell, eliminating the need for an internal flue. 7. Combined effect of wet booster fans and Pennguard lined chimneys The study performed by Alden Research Laboratory shows, that at an ambient temperature of minus 10 C, the temperature of the flue gas is reduced by 1.6 C as it flows from the booster fan outlet duct to the top of the chimney. This means, that at nominal load the temperature increase of 1.95 C created by the wet booster fans is greater than the temperature decrease experienced by the flue gas as it flows to the top of the chimney. As a result, both the thermal condensation rate ("cold wall condensation") and the adiabatic condensation rate (resulting from pressure loss) are kept at zero, effectively eliminating condensation in the wet stack.

It is important to consider that this finding is conservative because a portion of the fan wash water will not evaporate, effectively allowing a slightly stronger warming of the gas flow. It is also important to consider that in addition to their calculations, Alden Research Laboratory have developed and designed a system of liquid collectors and drains, both in the FGD outlet duct between the FGD scrubber and the wet booster fan (for liquid carryover from the FGD scrubber) and in the outlet duct and chimney breeching downstream of the wet booster fans (for non-evaporated droplets from the fan wash cycle). As usual for wet stack projects, Alden built a detailed scale model of the FGD plant, outlet duct and chimney breeching to develop, test and validate their proposed liquid collector and drain system (Figure 4). Figure 4: Detailed scale model of the FGD plant, outlet duct and chimney breeching to develop, test and validate the proposed liquid collector and drain system. 8. Conclusion The study has shown, that in addition to the fan efficiency increase achieved by placing FGD booster fans downstream of the FGD scrubber, this design choice can have environmental advantages as well. The combination of the temperature rise of the flue gas in the booster fans and the excellent thermal insulation offered by Pennguard lined chimneys can reduce or effectively eliminate condensate formation in the wet stacks. Nevertheless, the use of a well

designed system of liquid collectors and drains both in the FGD outlet ducts and in the chimney breeching is still required. References Brick lining versus Pennguard lining, Detailed Chimney Designs, Comparison of Masses, Labor, Construction Costs, Failure Analysis Associates, June 1998 Evaluation of Pennguard Stack Liner Material for Application in Wet Stacks, Alden Research Laboratory, Inc., August 2001 Designing wet duct/stack systems for coal-fired plants, Alden Research Laboratory, Inc., Article for Power Magazine, March 2006