Energy Trasmission & Distribution Services - Italy. Retrofit solutions for plant modernization. Answers for energy.

Similar documents
SION Vacuum Circuit-Breakers

FALCON SERIES 12 METAL CLAD

FALCON SERIES 12 METAL CLAD

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

ABB Medium Voltage Days MEA 2016 Proactive safety ABB medium-voltage switchgear

Advantage Services Capabilities

Fifty years of Vacuum Interrupter Development in the UK. 3.1 Introduction

Vacuum Interrupters. Outstanding vacuum-related manufacturing techniques of MEIDEN has

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities.

Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series. Energy Division

AQ 100 Series. Arc Flash Protection System

Transportation. Distribution

ENERGY PRODUCTS DIVISION. Polymeric Surge Arresters Reliable protection for power equipment upto 800kV

Withdrawable module with vacuum circuit-breaker 3AE and installation accessories kv, ka kv, 40 ka 24 kv, ka

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

RAYCHEM MEDIUM VOLTAGE

NPS/003/030 Technical Specification for Transformer and Switchgear Cable Boxes and their associated Bushing Assemblies

Schneider Electric solutions for the PV market. Denis Koch Strategy Director / Renewables January 2011

SPECIFICATION NPS - 210/6 FOR SF6 INSULATED SWITCHGEAR FOR SYSTEM RATED VOLTAGE UP TO 24 kv

Time Extension: Tender submission deadline is extended up to 12:00 Hrs. of

Product Guide Low Voltage Switchboard & Switchgear

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

MADE IN ITALY. thermowatt.com. the heart of electric appliances

FIRE PROTECTION TECHNOLOGY Solutions never thought of before

POWER CONTROL! WE SPEAK THE SAME LANGUAGE

SIVACON Partner Program and MVC Juergen Loeschberger, Siemens EM LP Partners. 21, 2017 I Berlin

Insulation and Protection Enhancing the Reliability of Overhead Power Systems

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

HRS Hand Rail System 1

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

3AH3 OPERATING INSTRUCTIONS. Vacuum circuit-breaker 3AH AH33. Order no.: E Ordering location: IC LMV LP PO P C41 AG 08.

Siemens Parts 3AH47 OPERATING INSTRUCTIONS. Vacuum circuit-breaker 17.5 kv Hz and 27.5 kv - 50/60 Hz

RAWABI ELECTRIC

Integrated Process Solutions. Series 46 Heaters HEATER JACKETS FOR STAINLESS STEEL PIPING SIZES 1 1/2 TO 4 (NW 40 TO NW 100)

NPS/003/025 Technical Specification for Fault Throwers

VAMP 120 & 121. Arc flash detection units. Product picture

Siemens Switchgear Manual READ ONLINE

A three-pole dead-tank SF 6 circuit-breaker incorporating one interrupter per pole in single-pole enclosures with a common operating mechanism

I N D I V I D U A L SWITCH G E A R

THE COMPLETE SOLUTIONS PACKAGE

SION Lateral OPERATING INSTRUCTIONS. Vacuum circuit-breaker 12 kv 24 kv 12.5 ka 25 ka

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

OPERATING INSTRUCTIONS

Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018

Gambling with your fire security?

CENTRAL STERILE SUPPLY DEPARTMENT

The organization has been a loyal partner on the Bulgarian and European market for 25 years already.

PD alarm system brings peace of mind in Malta

ELECTRONIC EQUIPMENT PRODUCTION SPECIALS

Oil burners fuel unit with solenoid valve

MODULAR TRACTION SUBSTATIONS CITY ELECTRIC TRANSPORT

How to reduce exposure to arc flash hazards

PolyGarde Metal-Oxide Surge Arresters

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

Lloyd s Register Type Approval System Test Specification Number 3

Substations and high voltage installations exceeding 1 kv a.c.

Refrigerated Compressed Air Dryers

EXPRESSION OF INTEREST (EOI) FOR. Fire Fighting System (FFS)

One giant leap for safety: AZM400.

PGR-8800 TECHNICAL FAQ

High-efficiency oil-free Compressor

50 barg refrigeration dryers PoleStar Smart HP

Temperature sensors for semi conductor & solar industry

Substation Monitoring System

INTERNATIONAL STANDARD

Giving WEEE new life.

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

Cooker Hood LA-72-CAN.

Arc Fault Detection Devices (AFDDs) Protecting People and Property

Green Electricals Pvt. Ltd.

DC POWER DISTRIBUTION BOARD

Datasheet - AZM 161SK-12/12RK-024

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Substation Signage. Document Number: 1-11-FR-12

P-LINE LM 7 P ES 7 P

ADVANCE ELECTRICAL MEP CONTRACTING TRADING SERVICES

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE

Danfoss the world s biggest producer of radiator thermostats

MAINTENANCE OF LV SWITCHGEAR SECTOR / ENGINEERING TECHNICAL & CERTIFIED TRAINING COURSE

Development of standards for MV Switchgear for Arc Flash protection. ABB Group May 20, 2013 Slide 1

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUXILIARY HEATER

PLUMBING HEATING GAS INDUSTRIAL ACTUATION HYDRONICS COMMITMENT TO QUALITY SPECIFICATIONS

Major Fault Caused by Stator Winding Circuit Ring Failure

3AK7 OPERATING INSTRUCTIONS. 3AK7 vacuum circuit-breaker. Order no.: A Ordering location: IC LMV LP PO P C41 AG 09.

GMA Panels with double busbar

51AKB / 51 AKC OWNER S MANUAL

High-Efficiency Heat Exchangers


LS Series Solvent Recovery Systems

Quality Marine Automation solution for efficient and safe navigation

Cutting edge washing systems

Outdoor RMU enclosure. Bosecker BOS series for Siemens 8DJH 11/22 kv RMU s

CONTENTS AUTOMATIC TRANSFER SWITCHES

Flame Safeguards LFE10. Building Technologies HVAC Products

Energy Saving Refrigerated Compressed Air Dryers DES Series 90 to 675 scfm (153 to 1148 nm 3 /h)

Transcription:

Energy Trasmission & Distribution Services - Italy Retrofit solutions for plant modernization. Answers for energy.

solutions for plant modernization Retrofit It is a intervention approach that provides the technical upgrade as well as the update of the installed equipment to the current standards. We have several years' experience in the development of new retrofit solutions for withdrawable circuit breakers for MV switchgears, that can be Siemens' or other manufacturer s. Thanks to our know-how we are able to realize technical solutions customized on our customers' requirements. All our equipments are tested with Type Tests in laboratories certified by SINAL to guarantee you the best solution for the market. Our solution includes To view the accredited tests go to the site www.accredia.it and click on "Banche dati" Circuit breakers Trucks Functional wiring of operating mechanism Safety interlocks The new Siemens vacuum circuit breakers used for retrofits mantain or improve the performance of the existing circuit breakers. They are maintenance free and enviromental friendly The new trucks for withdrawability have the same dimensional and functional features, the same main sectioning contacts and the same earthing system as the existing circuit breakers. The wiring of the auxiliary circuit connectors and its features are identical to those of the existing circuit breakers. The new circuit breakers for the retrofit solutions are integrated with interlock devices identical to the ones installed in the existing circuit breakers.

Siemens vacuum circuit breakers Thanks to our experience of several years in the design and manufacturing of medium voltage vacuum circuit breakers, we realize circuit breakers suitable for any kind of application. Market share for MV Circuit Breakers 100 90 80 70 50 40 30 10 0 19 7 36 1980 37 13 33 1982 45 15 28 1985 51 26 1988 56 24 1990 18 1993 62 16 1996 65 13 02 68 10 07 Quote di mercato interruttori in vuoto in Germania: >99% Nel mondo Vacuum SF6 Magnetic Min. Oil BulkOil In the world the market share of the vacuum circuit breakers is constantly increasing >68% The vacuum technology is the most globally widespread and it is constantly growing. 2.000.000 Many-fold pumping technology 1.500.000 1.000.000 Pieces 500.000 One-shot brazing technology 1972 1977 1982 1987 1992 1997 02 07 500.000 400.000 300.000 0.000 N 0.000 vacuum circuit breakers installed by Siemens until 09 a continuous innovation to get more and more success Pieces 100.000 0 1972 1977 1982 1987 1992 1997 02 07

Some examples of retrofit solutions Replacing the old Magrini Galileo magnetic circuit breakers type F and DHF within EPOCLAD switchgears with the New Siemens circuit breakers type 3AE. 7,2 kv 12 kv 17,5 kv Functional data with the new retrofit circuit breakers Rated Voltage KV Rated thermal current A Short circuit rated current KA KV bil KV 50Hz Old Magrini Galileo circuit breaker 7,2 800-3150 up to 40 12 75 28 17,5 24 800-00 95 125 38 50 Tip F-DHF Why is it necessary to replace the circuit breakers? Siemens is certified ISO 9001:08. This proves the Group capability to deliver products that answer customers' needs, ensuring a continuous improvement. Improve reliability and performance Reduce operational and maintenance costs Reduce shut-down periods Protect investments in existing substations Improve environmental and workers' safety. with minimum lead time for updates Product range for Siemens vacuum circuit breakers for air insulated switchgear Up to 17,5 KV Up to 63 KA Up to 4.000 A Up to 40,5 KV Up to 40 KA Up to 2.500 A

Circuit breakers Vacuum interrupter Our VACUUM interrupter, the heart of the interrupting circuit of the vacuum circuit breaker Terminal disc Insulator (ceramics) Arcing chamber made of copper Fixed contact Manovable Contact Metal bellows Operating and connecting bolt Circuit breaker 3AH5 Circuit breaker 3AE (SION) CuCr Production process of the main contact materials Constant quality High purity of the material Homogeneous compound Minimum erosion High interruption capacity High electrical conductivity Low welding possibility Vacuum circuit breaker Maintenance free Constant quality of the extinguishing medium High reliability, small dimensions Suitable for all applications in medium voltage The success of Siemens vacuum circuit breakers is due to continuous research and technological development through Product specialists Routine and type tests Quality Management of the whole production supply chain Technology Monitoring Why Siemens? We offer the best vacuum circuit breakers on the market Top performance, longer life cycle Circuit breakers with 10.000 operations at full load Over 0.000 circuit breakers in operation all over the world More than 2.000.000 vacuum interrupters manufactured 40 years of experience Extensive experience in replacing existing circuit breakers We have been reliable, professional and financial partners for over 1 years We provide reliable, effective, efficient and competitive solutions We are committed to satisfy any requests of yours We guarantee site interventions in order to check anomalies and/or carry out repairs of potential faults in the shortest time possible.

Siemens S.p.A. Energy T&D Services Via Vipiteno, 4 128 Milano - Italy Phone (MI): +39 02 24365021 Fax (MI): +39 02 24365065 serviceptd.it@siemens.com www.siemens.it/serviceexp