RTD TEMPERATURE SENSING SYSTEM

Similar documents
ACCURATE ELECTRONICS INC

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

ESP TECHNOLOGIES LIMITED

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

DGC-500 DIGITAL GENSET CONTROLLER

Analog Input Module IC670ALG630

DGC-1000 DIGITAL GENSET CONTROLLER

Public Safety DAS Annunciator Panel

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

AO Annunciator Module

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

User Manual. Dryer Controller M720

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Dryer Controller M720

Variable Frequency Drive SERIES MP800 VFD

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Intelligent Security & Fire Ltd

Model 1062 Environment Monitor

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

OPERATION / INSTALLATION

Entero Voice Alarm system.

OVEN INDUSTRIES, INC.

Instruction Manual Model Backup Switch, 1 for 8

Across-the-Line SERIES MP300 Combined Manual and Automatic

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

INSTRUCTION MANUAL. Software Revision Card 3.2 DOCUMENT SES-KS E REV. 3

Carbon Monoxide Transmitter

Mark 25 Ultrapure Water Conductivity Analyzer

Pioneer-R16 Gas Monitor Operator s Manual

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

ANNUNCIATOR FIXED MODULE

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Danfoss gas detection unit Type GD Heavy Duty

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Entero Voice Alarm system. User guide

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100

Pump-Down Controller MODEL 4052

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION

ESSEX ENGINEERING CORPORATION

Soft Start Series MP700 Solid State, Reduced Voltage

Generator Gas Analyzer (GGA)

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Frequently asked questions: Intelligent Transmitter Series

TECHNICAL DATA OBSOLETE

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Advanced Test Equipment Rentals ATEC (2832)

SCAN200E USER S MANUAL

108A OTP1800. Grid Support. General Description

DT968C C.T. BATH CONTROLLER

Refer to Bulletin E-1101 for detailed information on the FLAME-MONITOR System.

Flair 500 Series Annunciators

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

APPLICATION DATA SHEET

Pump-Up Controller MODEL 4062

Ronan Model X96S Series Weighing System

Flostop TS D7E and A8E. Operation Manual

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

Flopurge TS. Operation Manual

Maintenance Manual ALARM SHELF 19D902821P1 & P2. ericssonz LBI-38496C. TABLE OF CONTENTS (Vendor Documentation)

MODEL P531, P532 AND P532UI FLAME MONITOR OPERATING MANUAL

USER MANUAL FOR OPERATING SYSTEM

TraceNet ECM Series Control System

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

HGM300/RDM800 PREVENTATIVE MAINTENANCE AND TECHNICAL SUPPORT. SECTION 1 HGM300 CPU reset, RDM800 CPU reset, WARM UP notes and HGM300 Self Test

APPLICATION DATA SHEET

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Oxygen (O2) Single-Point Gas Detection System

20 Light Remote Annunciator

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

Table of Contents SECTION PAGE

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Installation, Operating and Maintenance Manual

Product Manual SZ1145

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

Technical Manual. Level Alarm Unit CARLA & WIDS

Model 9010 and 9020 Monitoring Systems

Line Isolation Monitor (LIM) LIM2000plus

HALOGUARD TM IR MONITOR (OPTIONAL) FOUR or EIGHT POINT SCANNER INSTRUCTION MANUAL

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

Transcription:

General Overview RTD TEMPERATURE SENSING SYSTEM The Prime Technology RTD Temperature System 9219-00-0002 is a three-channel temperature measuring system that utilizes two RTD Temperature Sensor inputs per channel. The system is being offered for application to the temperature measuring of ordnance stowage areas on the SSGN upgrade. The Prime Technology RTD Temperature System 9219-00-0003 is a one-channel temperature measuring system that utilizes two RTD Temperature Sensor inputs. The system is also offered for application to temperature measuring of ordnance stowage areas on the SSGN upgrade. The 9219-00-0003 RTD Temperature System (Reference Figure 1) consists of the following modules; One One channel chassis (part number 9211-04-2000), One RTD Smart Indicator (part number 921222BA12A0027), One RTD Interface (part number 9219-96-0001), One Power Supply Assembly (part number 9211-96-0001) Two RTD Sensors (part number 9220-04-0003). The 9219-00-0002 RTD Temperature System (Reference Figure 2) consists of the following modules; One three channel chassis (part number 9211-04-4000), Three RTD Smart Indicator s (part number 921222BA12A0027), One RTD Interface (part number 9219-96-0001), One Power Supply Assembly (part number 9211-96-0001), and Six RTD Sensors (part number 9220-04-0003). The architecture of this design is based on Prime Technology s Model 9219 Temperature Indicator System that is used on the Virginia Class Submarine as the Lockout Trunk Indicator System. The Model 9219 System has been designed and [is to be] qualified to Electric Boat s (EB) Specification 4195. The design modifications required to meet this new application include updating the chassis Assembly of the 9219 to provide for two RTD input sensors per channel and to accommodate the addition of the RTD Interface s. 1

The new design efforts required for this project are the following. The RTD Interface The 4 bay (3 channel) 9211 chassis assembly The New RTD Sensor The Power Supply and RTD Smart Indicator s (Prime Technology Model 9212) will be used without change except the additional software features added for the Smart Indicator. The RTD Temperature Sensor is the normal pressure RTD Temperature Sensor that is a modification of the High Pressure design, used by the Lockout Trunk application, to reduce costs through redesigning the housing for the reduced specification requirements. The new design sensor will also have a much faster thermal response time that will fit the RTD Temperature System requirement. We will provide similarity claim documentation for the system, less the sensor, based on former qualification data. The similarity data is assumed to be acceptable in forming the basis of this proposal. We have included pricing for qualification, including the plan and report, for the new RTD Sensor. The qualification will consist of vibration, shock and a thermal response tests. Figures 1 and 2 show a block diagram of the single channel and 3 channel systems respectively. The Power Supply and RTD Interface will be the same for both configurations. The RTD Interface will be electrically the same in both configurations but will have different front panel assemblies. Chassis The chassis is used to house all of the sub-assemblies. It also contains the motherboards that interface to the sub assemblies as well as a channel selector switch (this switch is used on the threechannel chassis only), an Ext Alarm Switch and the common alarm circuitry. The chassis also includes all of the electrical interface connectors required. The Channel Selector switch is used to select a channel. The numbers on the Selector switch indicate the channel selection. The Ext Alarm switch is used to disable the external alarm. The Alarm Acknowledge, Test, up/down switches, the cloning connector and the test potentiometer are located on the Power Supply Assembly front panel. These controls are used to calibrate, test and clone (patent by Prime Technology) the Model 9212 Smart Indicator. The power comes in on connector J1. The RTDs used in each ordnance space share a connector. The connector for channel one is J4, channel 2 is J5 and for channel 3 is J6. The common alarm interface connector is on J2 and the External Alarm interface is on J3. Note: The one-channel system uses only J1 thru J4. 2

Power Supply The power supply module consists of an AC to DC power supply, illuminated fuse holder, AC power on indicator, Power on/off switch, set switch, alarm acknowledge switch, test potentiometer, test switch, up/down switch and cloning (Prime Technology patented Technology) port connector The AC to DC power supply converts 115vac 60hz, switched, fused power into unregulated +24vdc that is used by the modules in the panel. The test potentiometer, test switch, and channel select switch are used in conjunction to apply an internally generated test signal to a particular RTD Smart Indicator when the channel selector switch is in that channel s position and the test switch is in test mode. The Alarm Acknowledge switch is used to reset the local alarm lamp when an alarm is on. When the switch is moved into the alarm acknowledge position, and an alarm exists, the alarm indicator on the power supply module turns off. The Set and UP/DN switches are used for setup of the alarm levels on the Smart Indicator modules as well as other selectable features. The cloning port is used to clone the curve characteristics from the Smart Indicator located in the channel one position to the Smart Indicator to be updated. RTD Smart Indicator s The RTD Smart Indicator, the Prime Technology Model 9212, is used to process RTD information, display the temperature of the selected RTD, check for alarm conditions, and generate the output controls for the common alarm. The RTD signal used by the RTD Smart Indicator comes from the RTD Interface. The RTD signal to the RTD Interface is a lead length compensated signal. The signal that the RTD Interface selects to send to the RTD Smart Indicator is the highest temperature of the two RTDs connected to the RTD module. The Interface module makes the selection and applies that signal to the RTD Smart Indicator. The change required to the Model 9212 Smart Indicator design include software updates to allow for serial data to and from the RTD Interface. The Smart Indicator from this application can be used in other applications of the Smart Indicator however the changes as defined by this paragraph preclude the use of the standard Smart Indicator in this application. RTD Interface Reference figure 3 for the functional block diagram of the RTD Interface. The RTD Interface receives all of the RTD signals. The signals are then lead-length compensated. After the signals are compensated, which removes the errors due to the voltage drop across the RTD cabling lead-length, the two RTDs for each ordnance space are tested to validate that they are within the required range. If they are within a valid range they are compared to each other and the RTD signal that has the highest temperature is digitally communicated to the respective RTD Smart Indicator via the RS422 serial port. This results in a very accurate system not affected by 3

analog signal errors. The RTD Smart Indicator s will record a fault if a new serial message with its respective address is not received within one second. If an RTD is found to be out of the acceptable range, its bicolor Status LED on the front of the RTD Interface, is illuminated red. If the RTD is within the acceptable range, its status LED is illuminated green. The RTD Interface module records and stores the temperature data as follows. The highest and lowest Temperature registration from each ordnance stowage space is time stamp stored in memory. This data is saved for the last seven days of operation.. The RTD Interface displays the current highest and lowest temperatures on a small LCD display. There is one display for each channel located on the front of the RTD Interface. If the temperature history needs to be viewed, the RTD Interface module is selected by using the Chassis channel selector switch. The up and down switches on the power supply are then used to scroll thru the recorded history. Approximately Ten seconds after the last activation of the up or down buttons, the display will revert back to the current temperature automatically. The same RTD Interface will be used in the one channel panel and the three-channel panel. A display mask in the front display area will need to be changed depending on whether it is a single or three channel panel. To signify that the RTD Interface s processor is functioning normally, a blinking character will be displayed in the lower right corner of the LCD display. A one-milliamp current source, which is derived from the RTD Interface, is applied to each RTD. The RTD Interface is housed in a casing that is similar to the Model 9212 Smart Indicator module. It interfaces to the chassis utilizing the same method as the Model 9212 Smart Indicator. It slides into a bay designated for this module and interfaces through a rear connector into a mating motherboard connector. Accommodation of the added electronic module is the reason a 3-channel system utilizes a 4 bay chassis and a single channel system uses a 2 bay chassis. Reference figure 6 for mechanical properties of the RTD Interface. Input Power The input voltage used for powering the RTD systems will be 115vac 60hz. The single channel system will have a maximum current requirement of 250 ma AC while the three-channel system will have a maximum current of 600 ma AC. Common Alarm Both the single-channel and three-channel systems will have a set of common alarm contacts that will be capable of switching 24 Volts DC at 150 ma. The common alarm includes a supervisor, 6.8K-ohm ¼ watt +/- 5%, resistor across its contacts. If any of the channels exceed its temperature set point, a common and local alarm will be initialized. The local alarm will cause a relay to close, 4

which can be used to drive a remote bell to annunciate, and illuminates a light on the front panel of the temperature panel. The audible alarm, if used, can be silenced with a switch on the front of the temperature panel s power supply assembly. When the alarm is silenced, the alarm indicator on the power supply module starts flashing. The alarm set point range is settable over the entire temperature range. An illuminated LED on the bargraph of the RTD Smart Indicator indicates the alarm set point. When the bargraph is illuminated at the set point, the LED is turned off. This allows the set point to continue to be identifiable because all the LEDs above and below the set point are illuminated. System Accuracy The system, excluding the RTD sensor, has an accuracy of +/- 1 degrees Fahrenheit in the range of 20 to 180 degrees Fahrenheit full scale. Inclusive of the RTD sensor, the accuracy is +/- 3 degrees Fahrenheit full scale. Response Time The response time to a change in temperature includes Panel and RTD sensor. 9220-04-003 New Design, low-pressure sensor response time is less than 1 minute when measured per procedure detailed in MIL-STD-24388. Physical Dimensions The single-channel panel configuration is as shown in figure 4. The three-channel panel configuration is as shown in figure 5. Weight The single-channel Panel s weight will not exceed TBD pounds and the three-channel panel will not exceed TBD pounds. Degree of Enclosure Both panel s degree of enclosure are Drip proof to 45 degrees. Insulation Resistance Power inputs and chassis ground are isolated by greater than 10 Meg-ohms @ 500vdc. The input power, signal inputs, and alarm outputs shall be isolated by greater than 10 Meg-ohms @ 500vdc. 5

EMI The Panels are designed to meet MIL-STD-461D and Mil-STD-461C as defined in EB Specification 4195. Shock The Temperature Panels are designed to meet MIL-S-901 as defined in EB Specification 4195. Vibration The Temperature Panels are designed to meet MIL-STD-167-1 as defined in EB Specification 4195 Temperature The Temperature Panels are designed to operate in an ambient temperature range between 32 and 122 degrees Fahrenheit. The Temperature panel s storage temperature range is minus 40 to 154 degrees Fahrenheit. Humidity The Temperature Panels shall meet the humidity conditions as described in EB-3991 paragraph 3.6.4.3. This is the requirement set in EB specification 4195. 6

Figure 1 One-Channel Temperature System Power Supply RTD Indicator RTD Interface Power Power Common Alarm J1 J2 Common Alarm Mother Board #1 Mother Board #2 EXT Alarm Ext Alarm J3 RTDs ch1 J4 7

Figure 2 Three-Channel Temperature System Power Supply RTD Indicator RTD Indicator RTD Interface J1 Ch Sel Sw Mother Board #1 Mother Board #2 Mother Board #3 Mother Board #4 J2 Common Alarm J3 Ext Alarm J4 RTDs Ch 1 J5 RTDs Ch2 J6 RTDs Ch 3 8

RTD Interface Figure 5 Power Monitor reset spare inputs Isolated I/O up switch down switch set switch alarm ack switch Spare outputs Spare outputs RTD 1A RTD 1B RTD 1A input RTD 1B input Sensor Fail Acknowledge RTD 2A input 2.5Vdc Processor I/O Sensor Fail RTD 2A RTD 2B RTD 3A RTD Input/ Lead Length comp. Circuit BIT Voltage 1 RTD 2B power supply Sense RTD 3A Mux Amplifier input signal Transducer Input Amplifier A/D Microprocessor FPGA o/e spare inputs Spare outputs RTD 3B RTD 3B BIT Test input SelectTank level Input Programable Gain control BIT Test input SelectPressure input Display Interface Ch 1 Display Programable zero circuit Display Interface Display Interface Ch 2 Display Ch 3 Display Mux Select 0 Mux Select 1 Mux Select 2 + 28 Vdc unregulated Isolated DC/DC Converter +15 Vdc +5Vdc -15 Vdc +5Vdc 2.5vdc reference Voltage & Test Voltage 2.5 Vdc BIT Voltage 1 BIT Voltage 2 RS422 serial link to RTD Indicators Isolated RS422/485 Transducer 1A 1 ma Supply RTD 1current +15 Vdc +15 Vdc Sensor Fail Acknowledge (from microprocessor) Sensor Fail(from microprocessor) RS422 Receive(unused) Transducer 1B 1 ma Supply RTD 2 current +15 Vdc Transducer 1A Fail Ind red=fail green=good Transducer 1B Fail Ind red=fail green=good Memory RS232 Interface Transducer 2A 1 ma Supply RTD 3 Current +15 Vdc Transducer sensors Health Transducer 2A Fail Ind red=fail green=good Transducer 2B 1 ma Supply RTD 2 current Transducer 2B Fail Ind red=fail green=good Transducer 3A 1 ma Supply RTD 2 current Transducer 3A Fail Ind red=fail green=good Transducer 3B 1 ma Supply RTD 2 current Transducer 3B Fail Ind red=fail green=good 9

Figure 4: One channel Mechanical Outline. 10

Figure 5: Three channel Mechanical Outline 11

Figure 6: RTD Interface front view. 12