Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinklers General Description

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Sprinkler Identification Numbers

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

Sprinkler Identification Numbers

Model TY-FRFS, TY-FS Special, and TY-FS Flat Spray Sprinklers, Upright and Pendent 57, 80, and 115 K-factor General Description

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Sprinkler Identification Number (SIN)

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response)

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

* Temperature rating is FIGURE K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS

Submittal Packages Detailed with Items and Reviewers

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

G3/8" DIN ISO 228 THREAD SHOULDER AND DUST CAP MATING SURFACE. STYLE H ESCUTCHEON (SEPARATELY ORDERED) 85 mm DIA. (3-3/8")

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Quick Response, Standard Coverage General Description

Worldwide Contacts. Technical Data

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Technical Data. Sizes 2 12 Inch (DN50 DN300)

FIGURE 1 MODEL RFIII ECLH CONCEALED HSW SPRINKLER ASSEMBLY AND FEATURES. 5/16" (7,9 mm) MIN. 9/16" (14,3 mm) MAX.

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

Model/Sprinkler Identification Numbers

RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

Technical Data. Sizes: ANSI Inches (DN) 2-1/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250)

Series ELO K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

MODEL: FA003U FA004U FA005P FA006P STANDARD SPRAY, STANDARD QUICK RESPONSE, 5 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD

Worldwide Contacts.

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Automatic Sprinklers

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description

Automatic Sprinklers

UL LISTED. SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed. RESPONSE Quick response Standard response

Care and Maintenance

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

Model WS TM 5.6 K-factor Specific Application Window Sprinklers, Horizontal and Pendent Vertical Sidewall General Description

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-Factor General Description

Sprinkler Identification Number (SIN) TY4234. Page 1 of 8 APRIL 2012 TFP Technical Services

Series LFII Residential Pendent Sprinklers 4.9 K-factor General Description

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

The Series LFII (TY3596) Residential

Sprinkler Identification Number TY ECLH HSW, 8.0K, 3/4"NPT

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

AQUAMIST Mist Control Center (MCC) Pump Skid Unit. General Description. Technical Data. Page 1 of 8 JANUARY 2016 TFP2270. Worldwide Contacts

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Norminal Sprinkler Temperature Rating

Sprinkler Identification Numbers

Transcription:

Worldwide Contacts www.tyco-fire.com Series Multiple Jet Controls DN20, DN25, DN40, and DN50, 2 bar BSPT Inlet & Outlets Threads General Description The TYCO Series Multiple Jet Controls are control valves with selfcontained heat actuating units. Available in DN20 through DN50 pipe sizes, they are designed for use as the system control valve for fire protection systems of limited size, where the s are located within the protected area. Upon operation, the s permit a flow of extinguishing medium (usually water) through open spray devices, such as nozzles or non-automatic (open) sprinklers. The s are typically used as an auxiliary deluge valve to control the flow of water to specific areas within a larger wet pipe, dry pipe, or deluge system. As such they can be used with supply piping from either a wet pipe system (Figure ) or a dry pipe or deluge system (Figure 2). In all cases, waterflow alarms are provided by the main automatic control valve for the system that supplies the supply line to the Series Multiple Jet Controls (e.g., alarm valves, dry pipe valves, or deluge valves). For smaller design areas, the s serve as an individual heat activation point and control valve (Figures A and 2A). For larger design areas, the s can be set up to provide multiple heat activation points, while still providing water flow through all discharge points with the activation of only one (Figures B and 2B). In this example, water flows through the non-operated from outlet to outlet (Figure 9). Features Available in four pipe sizes Fully automatic using proven frangible glass bulb as the heat detection medium Installed upright (heat sensitive bulb at top) for water supplies from either a dry pipe or deluge system or pendent (heat sensitive bulb at bottom) for a water supply from a wet system Defined areas of protection to provide total coverage of specific zones DN25, DN40, and DN50 provided with protective guard DN25, DN40, and DN50 has option for thermoelectric actuation that can be used in combination with highly sensitive detection systems and/or manual electric actuation NOTICE The TYCO Series Multiple Jet Controls described herein must be installed and maintained in compliance with this document, as well as with the applicable standards recognized by the Approval agency, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. Contact the installing contractor or product manufacturer with any questions. Technical Data Approvals LPCB Approved (Refer to Tables A, B, C, and D.) Working Pressure Range,4 to 2,0 bar Temperature Ratings Refer to Tables A, B, C, and D. Pressure Loss Refer to Graphs A and B. Construction The TYCO Series Multiple Jet Controls are manufactured from cast iron, leaded gun metal, copper, brass, nickle silver, and glass (Figures 3, 4, 5, and 6). IMPORTANT Always refer to Technical Data Sheet TFP700 for the INSTALLER WARNING that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page of 0 OCTOBER 204 TFP346

Page 2 of 0 TO OPEN FROM NORMALLY WET LINE TO OPEN PIPING PIPING 's IN PENDENT POSITION FRANGIBLE GLASS AT BOTTOM 's FROM NORMALLY WET LINE OPEN OPEN FROM NORMALLY WET LINE NOTE: Supply piping and 's are to be located in areas at 4 C or greater. FIGURE A FIGURE B FIGURE TYPICAL PIPING ARRANGEMENT NORMALLY WET LINE (Series Multiple Jet Controls in Pendent Position with Heat Sensitive Bulb at Bottom) FRANGIBLE GLASS AT TOP TO OPEN TO OPEN PIPING 's IN UPRIGHT POSITION FROM NORMALLY DRY LINE 's FROM NORMALLY DRY LINE FIGURE 2A OPEN FROM NORMALLY DRY LINE PIPING FIGURE 2B OPEN FIGURE 2 TYPICAL PIPING ARRANGEMENT NORMALLY DRY LINE (Series Multiple Jet Controls in Upright Position with Heat Sensitive Bulb at Top)

Design Criteria Ambient Temperature For normally wet pipe systems, do not install Series Multiple Jet Controls in areas that are subject to freezing. Water Supply Water should be free of particles and/ or site debris. Do not use sea or brackish water. Piping Arrangements A wet supply line is typically being supplied from an alarm valve (Figure ) and the dry supply line is typically being supplied from either a dry pipe valve or deluge valve (Figure 2). Waterflow alarms, system pressure gauges, and flow test capability are therefore provided by the alarm, dry pipe, or deluge valve. Sequence of Operation For a wet pipe system supply, water is readily available for flow through the TYCO Series Multiple Jet Controls; however, water is only allowed past the s when the glass bulb in the s is actuated by heat (or the thermoelectric actuator). For a dry pipe system supply, operation of the glass bulb in the s when actuated by heat (or the thermoelectric actuator) releases air pressure to permit operation of a dry pipe valve, and then upon operation of the dry pipe valve, water becomes available to flow through the operated s. For a deluge system supply and upon operation of the deluge system in response to a dedicated supplemental detection system, water becomes available to the s; however, water is only permitted past the glass bulb in the s if the glass bulb has been actuated by heat (or the thermoelectric actuator). Installation Position The s is installed in the upright position (heat sensitive bulb at top as illustrated in Figures 3, 4, 5, and 6) when supplied from a dry pipe or deluge system, or can be installed in the pendent position for a wet pipe system supply (heat sensitive bulb at bottom). For example, in a wet pipe system supply, the s can be installed above a ceiling where its heat sensitive bulb is exposed below the ceiling line. In all cases, the heat sensitive bulb must be in the protected area. Since the s utilize a thermal sensing element similar to that used for a standard response, standard coverage, frangible glass bulb type sprinkler, the positioning rules for s are the same as standard sprinklers. The heat sensitive bulb to ceiling distance and the area of thermal coverage is based on standard coverage sprinklers as a function of the protected hazard and ceiling construction provided in the applicable standards recognized by the Approval agency for standard coverage sprinklers. Pressure Loss Graph A provides the pressure loss versus flow for the configured as a single outlet, and Graph B provides the pressure loss versus flow for the configured for double outlets. Thermoelectric Actuation When the Thermoelectric Actuation is applied, the s can be operated automatically as part of a heat/smoke detection system or manually. In either case, suitable control equipment must be selected based on the actuator electrical ratings (Figure 7), the requirements of the customer, and the codes governing installation of electric detection systems. The actuator leads are encased in a flexible conduit (Figure 7) for attachment to an electrical junction box. When considering the power supply for operating the Thermoelectric Actuators, be aware that the Thermoelectric Actuator, after operation, may be an open circuit, short circuit, or connected to earth. Therefore, it is essential that the power supply be suitably protected. The recommended storage life (at ambient temperature) for the Thermoelectric Actuator according to the supplier is 0 years (for METRON * Actuators, refer to DR2005/C). The working temperature for the Thermoelectric Actuator is -40 C to 00 C (for up to 20 hours provided any temperature greater than 70 C occurs immediately prior to firing). Storage temperature is -30 C to 70 C. After 0 years, the TYCO Series Multiple Jet Controls supplier should be contacted regarding the suitability of the unit for continued use. Operation The DN20 TYCO Series Multiple Jet Controls has an inlet connected to either a single or double outlet (Figure 3). For the DN25, DN40, and DN50 s, the central inlet is connected to the double outlets (Figures 4, 5, and 6). Using a cap instead of one of the two unions on the DN25 and DN40 TFP346 Page 3 of 0 sizes or plugging one of the two unions on the DN50 size will convert a double outlet into a single outlet (Figures 4, 5, and 6). In all cases, the inlet is sealed from the outlet(s), and there is a normally open flow path from the outlet-to-outlet of double outlet s (Figure 9). In the standby mode, the system supply is sealed by the Diaphragm, that is restrained by the Plunger. In the DN20 assembly, the Plunger is held in position directly by the frangible glass Bulb. In the DN25, DN40, and DN50 assemblies, the Plunger is indirectly held in position by the frangible Bulb and the Lever Arm (Figures 3, 4, 5, and 6). The frangible glass Bulb contains a liquid that has a freeze-point below -50 C and a high coefficient of expansion. A predetermined amount of vapor is hermetically sealed within the frangible glass Bulb. The liquid naturally expands under the influence of increasing temperature as occurs in the event of a fire, thus increasing the internal pressure within the frangible glass Bulb until the vapor is absorbed and subsequently shatters the frangible glass Bulb allowing the s to open. The temperature at which this happens is determined by the amount of vapor held within the frangible glass Bulb thus the operating temperature of the s can be accurately controlled (Figures 3, 4, 5, and 6). In the event of a fire the frangible glass Bulb shatters and directly releases the Plunger Valve of the DN20 s or indirectly releases the Plunger by releasing the Lever Arm of the DN25, DN40, or DN50 s. This action in turn allows water pressure to lift the Diaphragm and allow water pressure to pass through to the distribution piping and water distribution devices onto the fire (Figures 3, 4, 5, and 6). When a Thermoelectric Actuator is utilized (Figure 7), the Thermoelectric Actuator responds to a Control Panel by passing a small electrical current through it causing a pin to be extended, shattering the glass Bulb and actuating the. The Control Panel may be automatically operated by a heat or smoke detection system or manually operated by a manual pull station.

Page 4 of 0 09 mm 82,5 mm 82,5 mm Components: - Body 2 - Inlet * 3 - Diaphragm 4 - Plunger 5 - Bulb 6 - Gasket 7 - Compression Screw 8 - Upper Cone Assembly 9 - Union 0 - Thrust Plate - Lower Cone 9 65 mm 2 - O-Ring** shown 3 - O-Ring upright; may be Housing** oriented as 4 - Spring Plate** pendent. * Temperature rating and year of manufacture indicated on 3 Inlet wrench flat. ** Single Outlet only. 82,5 mm 56 mm 8 3/4" BSPT 3 mm SEE DETAIL ABOVE 4 5 SEAT DETAIL 4 0 2 7 5 4 WRENCHING SQUARE 30 mm ACROSS FLATS 3/4" BSPT 48 mm 9,0 mm DIA. SINGLE ORIFICE FIGURE 3 DN20 SERIES MULTIPLE JET CONTROLS FIGURE FE88 SINGLE AND FIGURE FE86 6 3 2 Components: - Body 9 - Compression 2 - Inlet * Screw 3 - Diaphragm 0 - Plunger 4 - Plunger Cap 5 - Bulb - Lower Cone 6 - Union 2 - Lower Tip 7 - Lever 3 - Guard 8 - Upper Cone 4 - Guard Screw Assembly 5 - Warning Label 6 - Pipe Cap (Single Outlet only) * Temperature rating and year of manufacture indicated on Inlet wrench flat. shown upright; may be oriented as pendent. 96 mm 98 mm 76 mm 98 mm 98 mm mm 0 9 7 5 6 6 " BSPT 45 mm 8 3 5 4 62 mm WRENCHING 2 4 SQUARE 38 mm " BSPT 3 2 ACROSS FLATS 25,4 mm DIA. SINGLE ORIFICE FIGURE 4 DN25 SERIES MULTIPLE JET CONTROLS FIGURE FE90 SINGLE AND

Page 5 of 0 Components: - Body 9 - Compression 2 - Inlet * Screw 3 - Diaphragm 0 - Plunger 4 - Plunger Cap 5 - Bulb - Lower Cone 6 - Union 2 - Lower Tip 7 - Lever 3 - Guard 8 - Upper Cone 4 - Guard Screw Assembly 5 - Warning Label 6 - Pipe Cap (Single Outlet only) * Temperature rating and year of manufacture indicated on Inlet wrench flat. shown upright; may be oriented as pendent. 230 mm 0 mm 5 mm 90 mm 5 mm 5 mm 9 0 7 5 6 6 " BSPT 60 mm 8 5 3 4 SINGLE WRENCHING SQUARE 5,5 mm ACROSS FLATS -/2" BSPT FIGURE 5 DN40 SERIES MULTIPLE JET CONTROLS FIGURE FE8 SINGLE AND 72 mm 2 3 38, mm DIA. ORIFICE 2 4 Components: - Body 8 - Top Plate * 4 - Upper Cone 2 - Pipe Plug 2 - Inlet 9 - Top Plate Assembly (Single Outlet only) 3 - Diaphragm Screw 5 - O-Ring 22 - Transit Plug 4 - Plunger 0 - Union Half 6 - Lower Cone (Remove at 5 - Bulb 6 - Compression Screw - Union Nut 2 - Union Joint Ring 7 - Lower Tip 8 - Guard 9 - Guard Screw installation) 7 - Lever 3 - Stop Screw 20 - Warning Label 225 mm * Temperature rating and year of manufacture indicated on Top Plate. shown upright; may be oriented as pendent. 36 mm 2,5 mm 35 mm 2,5 mm 2,5 mm 6 84 mm 52 mm 3 7 20 8 4 8 SINGLE 2 WRENCHING HEX 76,2 mm ACROSS FLATS 9 2 5 4 -/2" BSPT 6 9 82 mm 7 5 64 mm 2 0 3 50,0 mm DIA. 22 ORIFICE 2" BSPT FIGURE 6 DN50 SERIES MULTIPLE JET CONTROLS FIGURE FE92 SINGLE AND

Page 6 of 0,00 0,80 0,60 0,50 0,40 NOMINAL PRESSURE DROP IN BAR 0,30 0,20 0,0 0,08 0,06 0,05 0,04 0,03 0,02 DN20 (K=80) DN25 (K=250) DN40 (K=280) DN50 (K=640) INLET OPERATED SINGLE 0,0 0 20 30 40 60 00 200 400 600 000 FLOW RATE IN LITERS PER MINUTE (LPM) GRAPH A NOMINAL PRESSURE LOSS VERSUS FLOW SINGLE,00 0,80 0,60 0,50 0,40 NOMINAL PRESSURE DROP IN BAR 0,30 0,20 0,0 0,08 0,06 0,05 0,04 0,03 0,02 DN20 (K=25) DN25 (K=370) DN40 (K=550) DN50 (K=920) INLET OPERATED 0,0 0 20 30 40 60 00 200 400 600 000 FLOW RATE IN LITERS PER MINUTE (LPM) GRAPH B NOMINAL PRESSURE LOSS VERSUS FLOW

Page 7 of 0 Installation The TYCO Series Multiple Jet Controls must be installed per the system designer s specifications, which have been based on the information provided in the Design Criteria section. Exercise care to avoid damage to the s before, during, and after installation. Replace s damaged by dropping, striking, wrench twist/slippage, or the like. Also, replace any s that have a cracked bulb or that has lost liquid from its bulb. The DN25, DN40, and DN50 s are provided with a Notification Tag (Figure 8). Do not install a TYCO Series Multiple Jet Control if the bulb is cracked or there is a loss of liquid from the bulb. With the held so that the bulb is horizontal, a small air bubble should be present. The diameter of the air bubble is approximately 4,5 mm to 6,4 mm for the 68 C to 4 C temperature ratings. The s utilize a frangible glass bulb heat sensitive element. Handle with care. The DN25, DN40, and DN50 s are provided with a guard. Removal of the guard voids the manufacturer s warranty. Care and Maintenance Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this decision. After a fire, replace all TYCO Series Multiple Jet Controls that have operated with new Series Multiple Jet Controls of the same type and temperature rating. Complete the replacement as soon as possible and after the system is drained. Spare Series Multiple Jet Controls should be kept on site at all times to ensure replacements are installed with minimum of delay. Never paint, plate, or coat, or otherwise alter s after they leave the factory. Modified s must be replaced. s that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the s with a cloth or by brushing it with a soft bristle brush. Exercise care to avoid damage to the s before, during, and after installation. s damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Inspection, testing, and maintenance must be performed in accordance with the requirements of the authority having jurisdiction, and any impairment must be immediately corrected. s that are found leaking or exhibiting visible signs of corrosion must be replaced. Also, replace any s that have a cracked bulb or that has lost liquid from its bulb. (Refer to Installation Section.) Inspections will be limited to a visual inspection as would be performed for automatic sprinklers and at a frequency as required for automatic sprinklers. The TYCO Series Multiple Jet Controls, by the nature of their design, cannot be trip tested. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of any authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Multiple Jet Control Specify: (specify size and temperature rating) TYCO Series Multiple Jet Control, Figure (specify) Multiple Jet Control (with electrical actuator, if applicable), P/N (specify from Tables A, B, C, or D).

Page 8 of 0 GUARD BROKEN AWAY TO SHOW DETAIL ELECTRICAL CHARACTERISTICS Nominal Energy.................. 6 millijoules Resitance Range................. 0.9 -.6 Ω Maximum No Fire Current 30 sec. Pulse................... 0.5 A 0.05 sec. Pulse................. 0.3 A Minimum Single Firing Current D.C........................... 0.6 A 0 ms. Pulse................... 0.9 A Recommended Single Firing Current...0 A Recommended Series Firing Current.. 3.0 A Maximum Monitoring Current........ 0.0 A GUARD BROKEN AWAY TO SHOW DETAIL TOP PLATE SUPPORT ADAPTER ADAPTER FLEX CONDUIT CONDUIT CONNECTOR TOP PLATE SUPPORT FLEX CONDUIT LEADS LEADS FIGURE 7 OPTIONAL THERMO-ELECTRIC FOR DN25, DN40, AND DN50 SERIES MULTIPLE JET CONTROLS GUARD NO ADHESIVE THIS PORTION OF LABEL (WATER FLOW THROUGH IN EITHER DIRECTION) LEVER PLUNGER (WATER FLOW THROUGH IN EITHER DIRECTION) NON-OPERATED DIAPHRAGM INLET (PRESSURE FROM, NO WATER FLOW) GUARD WARNING SIDE WARNING SIDE FIGURE 8 NOTIFICATION TAG FOR DN25, DN40, AND DN50 SERIES MULTIPLE JET CONTROLS (WATER FLOW FROM ) PLUNGER (WATER FLOW FROM ) OPERATED DIAPHRAGM INLET (WATER FLOW FROM ) FIGURE 9 MULTIPLE JET CONTROLS OPERATION

Page 9 of 0 DN 20 20 FIGURE and STYLE FIGURE FE88 SINGLE FIGURE FE86 APPROVALS 2 RATING MAXIMUM WHERE IS LOCATED Notes:. Approved by the Loss Prevention Certification Board (LPCB Refer to No. 007f/0). 2. Approved by the Loss Prevention Certification Board (LPCB Refer to No. 007f/02). LIQUID COLOR 57 C 27 C Orange SO0027A 68 C 38 C Red SO0027B 79 C 49 C Yellow SO0027D 93 C 63 C Green SO0027E 4 C C Blue SO0027G 57 C 27 C Orange DO0027A 68 C 38 C Red DO0027B 79 C 49 C Yellow DO0027D 93 C 63 C Green DO0027E 4 C C Blue DO0027G TABLE A LABORATORY LISTINGS AND APPROVALS FOR DN20 SERIES MULTIPLE JET CONTROLS DN 25 25 FIGURE and STYLE FIGURE FE90 FIGURE FE2656 AND ELECTRICAL ** APPROVALS RATING MAXIMUM WHERE IS LOCATED LIQUID COLOR DOUBLE SINGLE 57 C 27 C Orange DO0034A SO0034A 68 C 38 C Red DO0034B SO0034B Notes:. Approved by the Loss Prevention Certification Board (LPCB Refer to No. 007f/03). : Not Approved * Not Available ** On request, avaiable with Walkbery flex cable. 79 C 49 C Yellow DO0034D SO0034D 93 C 63 C Green DO0034E SO0034E 4 C C Blue DO0034G SO0034G 57 C 27 C Orange 2503 *- - - 68 C 38 C Red 2505 *- - - 79 C 49 C Yellow 2507 *- - - 93 C 63 C Green 2509 *- - - TABLE B LABORATORY APPROVALS AND S FOR DN25 SERIES MULTIPLE JET CONTROLS

Page 0 of 0 DN 40 40 FIGURE and STYLE FIGURE FE8 FIGURE FE2378 AND ELECTRICAL ** APPROVALS RATING MAXIMUM WHERE IS LOCATED LIQUID COLOR DOUBLE SINGLE 57 C 27 C Orange DO0048A SO0048A 68 C 38 C Red DO0048B SO0048B Notes:. Approved by the Loss Prevention Certification Board (LPCB Refer to No. 007f/03). : Not Approved * Not Available ** On request, avaiable with Walkbery flex cable. 79 C 49 C Yellow DO0048D SO0048D 93 C 63 C Green DO0048E SO0048E 4 C C Blue DO0048G SO0048G 57 C 27 C Orange 25025 *- - - 68 C 38 C Red 25027 *- - - 79 C 49 C Yellow 25029 *- - - 93 C 63 C Green 2503 *- - - TABLE C LABORATORY APPROVALS AND S FOR DN40 SERIES MULTIPLE JET CONTROLS DN 50 50 FIGURE and STYLE FIGURE FE92 FIGURE FE2073 AND ELECTRICAL ** APPROVALS RATING MAXIMUM WHERE IS LOCATED LIQUID COLOR DOUBLE SINGLE 57 C 27 C Orange DO0060A SO0060A 68 C 38 C Red DO0060B SO0060B Notes:. Approved by the Loss Prevention Certification Board (LPCB Refer to No. 007f/03). : Not Approved * Not Available ** On request, avaiable with Walkbery flex cable. 79 C 49 C Yellow DO0060D SO0060D 93 C 63 C Green DO0060E SO0060E 4 C C Blue DO0060G SO0060G 57 C 27 C Orange 25037 *- - - 68 C 38 C Red 25039 *- - - 79 C 49 C Yellow 2504 *- - - 93 C 63 C Green 25043 *- - - TABLE D LABORATORY APPROVALS AND S FOR DN50 SERIES MULTIPLE JET CONTROLS GLOBAL HEADQUARTERS 400 Pennbrook Parkway, Lansdale, PA 9446 Telephone +-25-362-0700 Copyright 204 Tyco Fire Products, LP. All rights reserved. *METRON TM is a registered trademark of Nobel s Explosive Co., Limited.