Control valve S11T. Pilot burner ZT. Control valve S11T

Similar documents
Burner control unit BCU 370

Burner control units BCU 480

Burner control unit PFU 780

Burner control units BCU 460, BCU 465

Burner control unit BCU 370

Safety. Operating instructions Ionization pilot burners ZAI, ZMI, ZKIH DANGER. Contents WARNING CAUTION Edition 12.11

Boiler module and operator-control unit KM 921 with CUI 9xx for heating boilers

Burner control units BCU 480

Industrial & Commercial Thermal BCU 580

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

Self-recuperative burner for gas

Heating controller Lago

Burner control units BCU 560, 565

Burner control units BCU 560, 565

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

Safety. Operating instructions UV sensor UVS 5 DANGER. Contents WARNING CAUTION Elster GmbH Edition Please read and keep in a safe place

Safety. Operating instructions Pilot burners ZAI, ZKIH DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 09.

Energy management with a system. Edition GB. Control engineering and combustion technology for comfortable heating

Safety. Operating instructions Burners for gas ZIO 165, ZIO 200 DANGER. Contents WARNING CAUTION. Changes to edition 11.11

Safety. Operating instructions Burners for gas ZIC DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 05.

Old documentation - Only for your information! Product is not available anymore!

Increased efficiency for drying, firing and glazing. Edition GB. Heat treatment in the ceramics industry

Safety. Operating instructions Heater GP 40 DANGER. Contents WARNING CAUTION. Edition Please read and keep in a safe place

INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PARAGON GAS SALAMANDER

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

PACKAGED METALLIC BURNERS

Safety. Operating instructions Heater GP 95 DANGER. Contents WARNING CAUTION. Changes to edition Please read and keep in a safe place

FLAT FLAME AND EXCESS AIR BURNERS

INDITHERM. Low temperature gas burners

Old documentation - Only for your information! Product is not available anymore!

Propane Heater REMKO PGM 30 REMKO PGM 60

UV Flame Supervision System

EXCESS AIR BURNERS XNM SERIES FEATURES APPLICATIONS DESCRIPTION. Bulletin E3502 rev05 31/01/00

System controller for cascade control, heating boilers with solar, buffer and pel et control

VIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw

VIESMANN. VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW.

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

Increased efficiency for melting, heating and heat treatment. Edition GB. Gas-fired processes in the metalworking industry

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Logamax plus GB172/GB172T. Heat is our element. Technical Guide Issue 2011/06. Fügen Sie auf der Vorgabeseite das zur Produktgruppe passende Bild ein.

Stable High Vacuum. Oil diffusion pumps Oil vapor jet pumps

terrasschwank+ 4A Technical Manual NL (English) Patio gas-infrared-heater 0085BR0505 terrasschwank+ 7/2A with housing

PARAGON GAS FRYER INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS MODEL : PDGF/PDGFP

PRODUCT CATALOGUE. PACTROL SOLUTIONS New and Replacement electronics for the Gas Industry

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

"HC" AIRFLO. In-duct firing line burner

FLAME GRILL GAS-FIRED (NAT & LPG) The Clay Oven Company Ltd. Leading manufacturers of clay ovens since 1974

Storage tank size Rated volume [l] Actual volume [l]

VIESMANN. VITOMAX 200-WS Rated heating output 1.75 to MW. Datasheet. VITOMAX 200-WS Type M250

INSTALLATION AND MANINTENANCE INSTRUCTIONS

VIESMANN. Datasheet VITOMAX 200-WS. Hot water boiler for permissible flow temperatures up to 110 C 1.75 to MW

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

EN Instruction manual. gasprofi 1 SCS micro. The smallest laboratory gas burner with more safety. DIN 30665, part 1

VIESMANN VITOCROSSAL 300 Gas condensing boiler 787 to 1400 kw

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

SECTION 1 - INSTALLATION UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER 1.1 MODE

INSTRUCTION AND MAINTENANCE MANUAL

LAE10 LFE10. Use. Series 02

NEW. Quality and efficiency made of experience! Oil- and gas heated boilers for the professionals manifold proven.

SECTION AUXILIARY HEATER

Technical Bulletin. Gazco Riva2 800 & 1050 Gas Fires- Installation and servicing issues resulting in Glass Panel Failure.

COMPACT FLAME CONTROLLER CFC 100

chaffoteaux ltd. CORVECELT TS CONFORMS WITH EUROPEAN (BS5386Ptl) EN26 installation servicing requirements

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

Flame detector. The QRA4.U is for use with the following types of burner control:

SCR and SCR-ECO PREMIX CERAMIC HEATERS WITH MODULATION AND ON/OFF HEATING COOLING GREEN ENERGY RADIANT HEATING TECHNOLOGY AND INNOVATION

LUNA 850 V GOLD GAS INSTRUCTION FOR INSTALLATION AND USE. Passion for fire

SHAHI TANDOOR GAS- FIRED (NAT & LPG) From The Clay Oven Company Ltd. Leading manufacturers of clay ovens since 1974

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA

26 Mesh Belt Brazing Annealing Furnace. Continuous Mesh Belt Brazing Furnace

INSTALLATION - AND USER INSTRUCTIONS

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

USHO COOKER INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS MODEL: USHO. INSTRUCTION REF: IN152 ISSUE No. 4 DATE

Flame detector. The QRA4.U is for use with the following types of burner control:

1 - High-velocity gas burners

Economy Standard Comfort. Heat loss (W/K) Heat loss (kwh/24h) (3)

INDUSTRIAL BURNERS AND ACCESSORIES CATALOGUE

VIESMANN. Installation instructions VITOMAX 200-HW. for contractors

5 COMPONENTS AND FUNCTIONS SAFETY INSTRUCTIONS GENERAL GAS-TIGHTNESS TEST TESTING AND AUXILIARY TOOLS:...

INDITHERM. Low temperature gas burners

Flame detector. Building Technologies Division Infrastructure & Cities Sector

We offer ceramic radiant heaters and infra-red radiant tubes.

Gas Flare & Rail Burners Gas Flare & Rail Burners Installation Instructions

Torch framed Installation Guide

PYRO-LINE BURNERS 126LX 6LE 12LS DESCRIPTION MODEL: 3201

Chemical Processes in the Combustion

The Gaggenau Models and Dimensions. Edition 2013 / 2014.

Light oil - kerosene burner

RIELLO 40 GS/M SERIES

Installation & Operating Instructions For LPG Q5 Stoves IGNITE 5 GAS STOVE (CD1) HEREFORD 5 GAS STOVE (CD2) DESIRE 5 GAS STOVE (SD1) Manual Control

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

SECTION 1 - INSTALLATION UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER 1.1 MODE

WARNING FOR YOUR SAFETY FOR YOUR SAFETY. Outback Patio Heaters. Patio Heaters

Knight. Installation, Commissioning, User & Maintenance Instructions. Traditionally Gas Fired Single Flue Water Heater with Pilot Ignition

(Text with EEA relevance) Reference and title of the harmonised standard (and reference document) EN 26:1997/A1:2000 Note 3 Date expired (18.7.

Relaxed Premium M Relaxed Premium M ENG

Transcription:

Control valve S11T Pilot burner Product brochure GB 9.1 Edition 05.09 Control valve S11T Independent of mains power supply due to thermo-electric safeguarding Installation facilitated by pilot gas connection on both sides Available with contact switch for ignition with electrode Control valve S11T..R15 suitable for gas inlet pressures up to 1.5 bar Pilot burner Flame monitoring by thermocouple Thermo pilot burner, optionally available with forced draught connection Available for manual ignition or ignition with electrode Saves space due to its compact dimensions Different lengths make it suitable for individual installation situations Maintenance-friendly due to use of stainless steel www.kromschroeder.com

2 S11T, Edition 05.09 Control valve S11T..S with switch to control an ignition transformer Application Control valve S11T For thermo-electric safeguarding of gas-fired installations of any kind in conjunction with thermo pilot burners. The control valve S11T operates independently of mains power supply. The control valve S11T..S is fitted with a switch to control an ignition transformer. Pilot burner For safe ignition and thermo-electric safeguarding in conjunction with control valve S11T of atmospheric gas burners on furnaces in the metal, ceramics and non-ferrous metal industries, on heat treatment installations or in applications without voltage supply. Suitable for operation with natural gas, town gas or LPG. Pilot burner 1MI is ignited manually. Pilot burners 13MI, 32 and 42 are ignited using an ignition electrode. Pilot burner 13MI with soldered grounding cable and thermocable, pilot burner 42G with protective tube Wheel rim hardening installation Annealing furnace Intermittent shuttle kiln in the ceramics industry

S11T, Edition 05.09 3 Examples of application VG 6 Thermo-electric safeguarding with manual ignition The pilot burner is ignited manually. An additional gas solenoid valve VG 6 can be used as a safety valve, e.g. for overtemperature shut-down or power shortage cut-out. S11T GEH VG 6 Thermo-electric safeguarding with electrical ignition A contact is closed via the switch on the control valve S11T..S so that voltage is supplied to the ignition transformer. The pilot burner is ignited using an ignition spark. An additional gas solenoid valve VG 6 can be used as a safety valve, e.g. for overtemperature shut-down or power shortage cut-out. S11TS TZI L1 GEH

S11T, Edition 05.09 4 Selection Pilot burner capacity Capacity is dependent on the burner, the fitted burner nozzle and the gas type. For pilot burners 1MI und 13MI, a burner nozzle is installed at the factory with a 0.5 mm flow opening. When using town gas, a burner nozzle with a 0.8 mm flow opening has to be ordered separately. Burner Burner nozzle Burner capacity [kw] with gas type Natural gas LPG (propane) Town gas (ρ = 0.80 kg/ (ρ = 2.01 kg/ (ρ = 0.58 kg/ m 3 ) at 20 mbar m 3 ) at 50 mbar m 3 ) at 8 mbar 32..N. 42..N 0.8 1.3 32..F, 42..F 0.5 1 32..S, 42..S 1.8 2 1MI, 13MI 0.5 0.5 1 1MI, 13MI 0.8 0.5 Selection tables Control valve S11T 15 20 25 R 01 15 S* S11T 1) * If none, this specifi cation is omitted. 1) S11T 20R15 and S11T 25R15 are not available with switch. = standard, = available Order example S11T 25R15 Type code S11T Code S11T 15 20 25 R 01 15 S Description Control valve Nominal diameter [DN]: 15 20 25 Rp internal thread Inlet pressure p e : max. 100 mbar max. 1500 mbar With switch Selection tables Thermo pilot burner 1MI, 13MI 1MI 13MI = standard, = available Order example 13MI Type code Thermo pilot burner 1MI, 13MI Code 1MI 13MI Description Thermo pilot burner for control valve S11T For manual ignition With ignition electrode for electrical ignition Selection Table Pilot burner with protective tube G N F S -100 bis -500** /100 32 * 42 * If none, this specifi cation is omitted. ** Other protective tube lengths on request. = standard, = available Order example 42GN-200/100 Type code Pilot burner with protective tube Code Description Thermo pilot burner for control valve S11T 32 With ignition electrode and protective tube 42 With ignition electrode, protective tube and fl ame tube G For forced draught N Natural gas F LPG S Town gas Protective tube length* [mm]: -100 100-150 150-200 200-300 300-400 400-500 500 Flame tube length [mm]: /100 100 * Other protective tube lengths on request.

5 S11T, Edition 05.09 Technical data Control valve S11T Types of gas: natural gas, town gas or LPG. Pilot gas connection for 8 1 tube. Opening time: 10 15 s. Closing time (decrease of thermo-electric voltage + valve closing time): < 30 s. Ambient temperature: -20 to +60 C. Thermo-electric voltage: under load: 10 mv, extinction voltage: 8 mv. Max. inlet pressure p e : S11T..01 = 100 mbar, S11T..15 = 1.5 bar. Pilot burner Types of gas: natural gas, LPG or town gas. Capacity: approx. 1 2 kw. Thermo-electric voltage: under load: 10 15 mv, in idle state: 30 40 mv, extinction voltage: < 8 mv. 1MI, 13 Operation with Gas pressure* Burner nozzle Natural gas 15 30 0.5 LPG 30 50 0.5 Town gas 8 20 0.8** * I n the case of higher gas pressures, fi t additional gas restrictor orifi ce. ** Not included in the delivery; to be ordered separately. Certification S11T, EC type-tested and certified pursuant to Gas Appliances Directive (90/396/EEC) in conjunction with EN 125 Maintenance The system requires little servicing. Check the safety time of S11T/S11T..S once a year. 32 Operation with Gas pressure* Burner nozzle Natural gas 15 30 0.8 LPG 30 50 0.5 Town gas 8 20 1.8 * In the case of higher gas pressures, fi t additional gas restrictor orifi ce. 32G, 42G Operation with Gas pressure* Air pressure* Burner nozzle Natural gas 15 30 3 0.8 LPG 30 50 6 0.5 Town gas 8 20 10 1.8 * I n the case of higher gas/air pressures, fi t additional gas/air restrictor orifi ce.

6 S11T, Edition 05.09 Detailed information on this product www.docuthek.com Direct access Search term: S11T, Kind of document: Technical information Contact www.kromschroeder.com Sales Elster GmbH Postfach 2809 49018 Osnabrück Strotheweg 1 49504 Lotte (Büren) Germany T +49 541 1214-0 F +49 541 1214-370 info@kromschroeder.com www.kromschroeder.com www.elster.com Kromschröder, a product brand of the Elster Group We reserve the right to make technical modifications in the interests of progress. Copyright 2007 Elster Group All rights reserved. 03250833 Druck MM.JJ 0.000