"NP" & "RG" AIRFLO. In-duct firing line burner

Similar documents
Series LV AIRFLO. In-duct firing line burner

APX. Nozzle-mix line burner

"HC" AIRFLO. In-duct firing line burner

V-Line. Nozzle-mix line burner

DELTA-TE III. Nozzle-mix line burner

INDITHERM. Low temperature gas burners

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

INDITHERM. Low temperature gas burners

Specifications of V-Line burners

ECLIPSE AH-MA BURNERS. Air Make-Up Burners. Designed for trouble-free make-up or process air heating. Ready for the world

Lanemark Midco HMA2A Series Air Heating Burner and DB Duct Burner System Application Manual

PYRO-LINE BURNERS 126LX 6LE 12LS DESCRIPTION MODEL: 3201

Specifications of MULTIFIRE burners

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

DOM-5. Domestic Hot Water Heaters & Boilers

Boiler Basics. Design and operation

Eclipse AirHeat Burners

Eclipse AirHeat Burner

INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS

INDUSTRIAL MICRODIFFUSION OIL BURNERS

DIVISION FINNED WATER-TUBE WATER HEATERS

PBG PACKAGED GAS BURNER

Combustion Safety. RESNET Conference San Antonio, TX February 27, Presented by Rich Moore Lightly Treading Energy & Design Denver, CO

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

TOWER DRYERS TOTA TOT L VA AL V LUE. TOTA ALUE. TOT L SYSTEMS. AL SYSTEMS.

Ecomax. Direct-Fired Self-Recuperative Metallic Gas Burner. Features

Gas Safety. Syllabus. For 120kW. Class B gas fitter. Certificate of qualification examination

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

GLOBAL FINISHING SOLUTIONS

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

TUBE-O-THERM Low Temperature Gas Burners

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

HHA Bellerive Apartments 7225 Bellerive Houston, Texas J. Allen Management Managing Agent

SUH-8 UNIT HEATERS. High Efficiency Heating Equipment

FGR. Installation, Operation and Startup Instruction Manual FOR FLUE GAS RECIRCULATION SYSTEM. FGR-8 through FGR-22 (25 HP to 1000 HP)

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Eclipse AirHeat Burners AH Series version 2.00 (Patent Pending)

Energy saving and better heat control.

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

Module 5: Combustion Technology. Lecture 38: Combustion Burners

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

Revitalize Building Mechanical Systems (4619)

Tankless Condensing High Efficiency Water Heaters

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

LAARS MIGHTY THERM 2. High Efficiency Boilers and Volume Water Heaters

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

LAARS PENNANT. Economical efficiency for greater savings

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

RG7D 1-Stage Heat Series

HHA Lyerly Apartments 75 Lyerly Houston, Texas J. Allen Management Managing Agent

Products & Services. DISTRIBUTOR & FOREHEARTH SYSTEMS

HCLEARFIRE. High-efficiency, modular steam boiler HP

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*

UV Flame Supervision System

The ultimate in air handling units: directly and indirectly fired

Process Heat Equipment & Combustion Field Services Guide

DIVISION FINNED WATER-TUBE WATER HEATERS

Triton Series High Efficiency Boiler

INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH

Residential Gas Tankless Water Heater

Madhu Honap HONEYWELL THERMAL SOLUTIONS INTRODUCTION

INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207

High Efficiency Commercial Gas Water Heaters

Residential/Commercial Gas Condensing Tankless Models

1 - High-velocity gas burners

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

Gas Safety. Syllabus. For. Gas Appliance Service. Certificate of Qualification Examination. (Formerly Class C)

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

Trends for Radiant Tube Heated Strip Lines

FTIIIC-10. Domestic Hot Water Heaters and Boilers

Domestic Hot Water Heaters and Boilers FTIIIC-6

LOW NOx MODULATING GAS BURNERS

Seasonal Efficiency Longevity Part-Load Efficiency Condensing Operation Fast ROI MODULEX BOILERS MLX-1060 MLX-909 MLX-757

RESNET National Conference New Orleans, LA. February 16, 2009 Presented by Rich Moore Invisible Energy Denver, CO

25 Years IBS GmbH. Innovative and taylormade burner systems

Design Guide 111 9/25/2008. Eclipse Winnox Burners WX Series Version 1

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

PREVIEW COPY. Heating System Equipment. Table of Contents. Gas Heating Equipment...3. Oil Heating Equipment Electric Heating Systems...

Commercial Tankless Rack System

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

SUBMITTAL SCHEDULE & DATA

DIVISION FINNED WATER-TUBE BOILERS

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

Discover ebm-papst in commercial kitchen equipment. Durable and reliable products for constant use.

Direct Fired Heater Model AD Specification

6. Within an internal combustion engine, the can-shaped component that moves up and down the cylinder

Commercial Tankless Rack System

CONDENSING HIGH EFFICIENCY BOILERS

OIL AND GAS INDUSTRY

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

Transcription:

"NP" & "RG" AIRFLO In-duct firing line burner Duct burners - NP & RG AIRFLO 4-21.5-1 For direct fired fresh air heating applications Operates economically (100 % thermal efficiency) and installs easily Burns clean and odor-free with most gaseous fuels, meeting or exceeding most known standards for direct-fired make-up air and space-heating applications High turndown, up to 25 : 1 Modular design configured within your duct for optimal temperature distribution No need for a combustion air blower Extremely low maintenance cost thanks to robust design (no moving parts) and high quality materials

4-21.5-2 Product description "NP" AIRFLO principle 3 1) Fresh air 2) Fuel / gas 3) Hot air 1 2 MAXON Series "NP" & "RG" AIRFLO burners consist of a robust cast-iron or aluminum burner-body (which serve as the gas manifold) drilled to discharge the gaseous fuel between diverging stainless steel mixing plates. The burners are mounted directly into the air stream being heated. Gaseous fuel is injected into the process air stream. The unique designed V-shaped burner mixing plates are intimately mixing both gas and process air together. All available heat from the gaseous fuel is released directly into the air stream. The required oxygen for the combustion is progressively drawn from the process air stream. Carefully controlled aeration patterns provide progressive mixing, superior cross-ignition, flame retention and odor-free combustion. Air velocities across the burner (the key to successful operation) are established by the use of profile plates. Optimum performance demands that air velocities be uniform across the entire burner. System components normally used in conjunction with a MAXON "NP" AIRFLO or "RG" AIRFLO burner application 1) AIRFLO burner 2) Profile plate 3) Combustion chamber 4) Intake louvers 5) Main volume fan 6) Sequencing control panel 7) Differential air pressure switch 8) High temperature protection 9) Safety shut-off valves 10) Vent valve 11) Gas filter 12) Control valve 13) Pilot gas train 12 9 9 10 6 7 13 4 8 1 2 3 5 11

4-21.5-3 Available product sizes Several variations are offered, each optimized for a specific type of application. All are raw-gas burners, intended for use in fresh air streams. For make-up air heating NP-I and NP-II AIRFLO burner types provide a nominal capacity of 150 kw per foot. Turndown of 25 : 1. With staged burner configuration turndown may exceed 50 : 1. Optimum air stream velocity is 15 m (st) /s. NP-II AIRFLO burners are selected when gas supply pressure is too low for NP-I AIRFLO burners. NP-II AIRFLO burners will cover the same applications with a turndown of 20 : 1. For process air heating NP-I and NP-II AIRFLO burners may be used if temperature rise does not exceed 450 C. NP-III AIRFLO burners provide a nominal capacity of 300 kw per foot at an optimum air stream velocity of 20 m (st) /s for temperatures up to 650 C with a turndown of 20 : 1. NP-I AIRFLO burners can be supplied with special aluminum alloy bodies having stainless steel fasteners and aluminum back-up bars for corrosive applications. For 2-speed air handling systems Usually make-up air applications. RG -IV AIRFLO burners (for natural gas only) may be used for a nominal capacity of 150 kw per foot at an optimum velocity of 15 m (st) /s or 75 kw per foot at a velocity of 7.5 m (st) /s. Materials of construction Refer to page 4-21.5-10 of Specifications of "NP" & "RG" AIRFLO burners for more information on choices of material. Note that NP-I & RG-IV AIRFLO burners can be supplied with special aluminum alloy bodies having stainless steel fasteners and aluminum back-up bars for corrosive applications. Typical burner data Fuel : natural gas with 10.9 kwh/nm³ HHV - sg = 0.6 [1] Combustion air : 15 C - 21 % O 2-50 % Humidity - sg = 1.0 [1] Stated pressures are indicative. Actual pressures are a function of air humidity, altitude, type of fuel and gas quality. Burner size NP-I NP-II NP-III RG-IV Maximum capacity per foot [2] [5] kw HHV 150 150 300 75-150 Minimum capacity per foot [3] [5] kw HHV 6 7 50 7 Natural gas pressure required [2] mbar 12-14 6-7 12-14 12-14 Flame length [2] mm 250-300 250-300 700-800 300-350 Air velocity required [4] m/s 15 15 20 8-16 Pressure drop process air [4] mbar 1.5 1.5 2.5 0.4-1.5 Turndown 25:1 20:1 6:1 20:1 Fuel gas natural gas, propane,propane air mixture natural gas [1] sg (specific gravity) = relative density to air (density air = 1.293 kg/m³(st) [2] Higher gas pressure will result in higher heat release per unit and longer flame length. Contact MAXON for more information and performance limits in your particular application. Also see note (3). [3] Absolute min. capacity at optimal air flow (velocity and distribution). Min. capacity influenced by air velocity and burner application. Contact MAXON for your specific installation. [4] Air velocity for optimal burner performance. The burner will be able to operate within a given range of air velocity. The higher the velocity at a given gas pressure, the shorter the flame length, and the higher the pressure differential of the process air across the burner. [5] 1 foot = 305 mm

4-21.5-4 Applications Series "NP" AIRFLO and "RG" AIRFLO line burners are designed for direct heating of fresh, clean air for low and medium temperature air heating applications. Typical low temperature applications include humidity-controlled dual stage paint spray booths, general make-up air applications, packaged units, door heaters, grain drying, malt drying, etc. Typical high temperature process air applications include spray dryers, chemical dryers, fresh air oven heating, drying, baking and curing operations, metal parts finishing and all fresh air heating applications up to 650 C. These burners can also be mounted downstream of a steam or hot water coil thus bringing the air to a higher temperature.this can boost the capacity of an existing installation. Direct air heating with NP- III AIRFLO burners in continuous flow dryers for grain. 1) NP-I AIRFLO burner of 1 foot (150 kw) with end plates, bottom gas inlet, spark ignitor, pilot and flame rod 2) NP-I AIRFLO burner of 1500 kw complete with spark ignitor, pilot and flame rod 1 2

4-21.5-5 Dimensions and weights A B C D 1) NP-I / II / III AIRFLO 2) NP-*-12 straight section 3) Typical end view 4) RG-IV AIRFLO 5) RG-IV-12 straight section 6) Typical end view 1 2 3 A E F B C D E F 4 5 6 Dimensions in mm unless stated otherwise Burner size A B C D E F Weight [2] NP-*-12 straight section [1] 305 178 168 198 27 86 4.1 kg RG-IV-12 straight section [1] 305 222 216 257 27 86 4.4 kg [1] 12 (inch) = 1 unit = 305 mm Refer to Specifications of "NP" & "RG" AIRFLO burners for other burner sections (T-sections, L-sections, back inlet sections etc). [2] Weight of "NP" & "RG" AIRFLO burner section with cast iron body.

4-21.5-6 Typical emissions (burners only) MAXON Series "NP" AIRFLO & "RG" AIRFLO burners are especially designed to meet the high demands of most of the local standards on air quality of direct fired make-up air and space heating applications worldwide. If correctly used within the performance limits as described on page 4-21.5-3, both CO and NO x will remain far below the limits as determined in most standards. Example: NP-I firing on natural gas in make-up air heating at 150 kw/ftwith T of 60 K and uniform air velocity of 15 m/s: CO <<7 ppm/no << 4 ppm NO 2 << 1 ppm (as measured dry) Note that incorrect use or use outside the performance limits may seriously affect emissions. Exact emissions performance may vary in your application. Contact MAXON for information on installation specific estimates or guarantees. No guarantee of emissions is intended or implied without specific written guarantee from MAXON. Read Specifications of "NP" & "RG" AIRFLO burners for complete information on these burner types.