LOW EXPANSION FOAM FIRE EXTINGUISHING SYSTEM

Similar documents
MARINE CAPABILITIES BROCHURE PROTECTING OVER 1 MILLION LIVES EVERYDAY

Foam Products ENGLISH

RESOLUTION MSC.217(82) (adopted on 8 December 2006) AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

MSC Guidelines for Foam Fire Suppression Systems

RESOLUTION MSC.339(91) (adopted on 30 November 2012) AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE)

SECURITY BLANKET Foam Fire Protection Products

Notice on the implementation of the amendments to the FSS Code in resolution MSC.339(91)

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;

Notice No. 7. Rules and Regulations for the Classification of Ships, July Issue date: March Working together for a safer world

What is HI-FOG? The natural enemy of fire

DRY BULK HANDLING SYSTEM

Foam Systems U.S. Quick Reference Guide

Fire protection for buildings

WILLIAM HICKS. MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI. Associate Professor Eastern Kentucky University

FIRE SUPPRESSION SOLUTIONS

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

RESOLUTION MSC.291(87) (adopted on 21 May 2010) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CONVENTION FOR THE SAFETY OF LIFE AT SEA, 1974, AS

TWO TIMES THE FIGHT Twin-Agent Fire Suppression Systems

FIRE EXTINGUISHERS. Chapter 2. - Co2 Fire Extinguisher - Dry Foam Fire Extinguisher - Foam Fire Extinguisher - Portable Foam Applicator

Fire protection solutions for ships and offshore facilities

RESOLUTION MSC.292(87) (adopted on 21 May 2010) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

GUIDELINES FOR THE APPROVAL OF HELICOPTER FACILITY FOAM FIRE-FIGHTING APPLIANCES

Firefighting Monitors Tunnels Fire Protection Systems. Integrated Fire Safety and Security Solutions

A.U.P.C.I ASOCIACIÓN URUGUAYA DE PROTECCION CONTRA INCENDIO AUPCI

Safety is more than just being careful: it

High flying fire protection HI-FOG for aircraft hangars

NEBOSH International Technical Certificate in Oil and Gas Operational Safety

MORE THAN JUST FIRE PROTECTION

HI-FOG for Ro-Ro and Special Category spaces

Fire fighting excellence. HI-FOG water mist fire protection

Fire fighting excellence. HI-FOG water mist fire protection

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

RESOLUTION MSC.98(73) (adopted on 5 December 2000) ADOPTION OF THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

AMENDMENTS NO. 3/2012 to

The metering orifice is sized according to the type and percentage of concentrate used and is also secured with a stainless steel retaining ring)

Emergency shutdown systems. Procedures for bypassing ESD s

Fire fighting excellence. HI-FOG water mist fire protection

Fire. IMO fire control signs - according to IMO Resolution A.654 (16) (mm) 150x x200

MORE THAN JUST FIRE PROTECTION

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Fire protection solutions for ships and offshore facilities BRANCH SOLUTION

Spandau Pumps. Sealless Immersion Pumps for Industrial Applications. Overwiev of Products

DELIVER AS PROMISED A COMMITMENT TO CALIBRATION SERVICES ALL BRANDS & MAKERS PRESSURE / TEMPERATURE GAUGES & CALIBRATORS ULLAGE TAPES

Requirements for ships carrying hydrogen and compressed natural gas vehicles

Tel Web: dyayan.com

Fire fighting excellence. HI-FOG water mist fire protection

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

Nessie High Pressure Water Mist Components for Fire Fighting

DynaQube Portable Sample Cooling Device

Additional Fire Protection (F-AMC)

POLY extinguishing systems. The high-performance, unique, and versatile extinguishing system for initial, effective fire fighting.

Cable Ties JULY The electronic pdf version of this document found through is the officially binding version

Hazardous Goods Warehouse. VOSSCHEMIE GmbH. Preventive Fire Protection. Case study

ADDITIONAL FIRE PROTECTION (F-AMC)

Fire Fighting Foam and Foam Hardware

BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT

ISO INTERNATIONAL STANDARD. Ships and marine technology Lowlocation lighting on passenger ships Arrangement

Technical Information

Farms and Similar Agricultural Facilities

Only the Danish version is authentic Notice D II-2 N(2) 1 October 2002 CHAPTER II-2 N(2)

CombiPrime Self-priming centrifugal pumps

MB05. RESPOND TO EMERGENCIES BASIC KNOWLEDGE OF EMERGENCY PROCEDURES, INCLUDING EMERGENCY SHUTDOWN

II Brazilian Sprinkler Conference October 27-28, 2016

Fire fighting Questions

TECHNICAL DATA 3% AR-AFFF

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

COMMISSION REGULATION (EU)

Principles of Cold Insulation

RESOLUTION MSC.44(65) (adopted on 11 May 1995) STANDARDS FOR FIXED SPRINKLER SYSTEMS FOR HIGH SPEED CRAFT

Creating A Global Industrial Leader

DESIGNER AND SUPPLIER OF MARINE FIRE FIGHTING SYSTEMS

PHIREX AUSTRALIA. FOGEX & MISTEX WATER MIST FIRE PROTECTION

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

Ensuring safe passage HI-FOG for underground stations

Dual Agent Unit w / Atmospheric Tank 200 Litres DAHR 01

Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines,

Fireward Fixed Fire Fighting System. For Open Areas & Enclosed Risks fireward.co.uk

Adsorption Dryers for Compressed Air

CERTIFICATE OF FIRE APPROVAL

GENERAL SPECIFICATION SAFETY

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

DRY CHEMICAL POWDER SYSTEM REQUIREMENTS TO COMPLY WITH THE LATEST IMO IGC CODE AND EUROPEAN COUNCIL CLARIFICATIONS

ENHANCED FIRE PROTECTION ARRANGEMENTS

ClassNK Technical Information No. TEC-0453 Attachment (1) to ClassNK Technical Information No. TEC-0453 Guidance on SOLAS Chapter II-2 as amended in 2

MONITORS FOR FIRE-FIGHTING.

Guidance on the construction of CO 2 systems

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

DESIGN AND CONSTRUCTION

IMO. Resolution A.952(23) Adopted on 5 December 2003 (Agenda item 17) GRAPHICAL SYMBOLS FOR SHIPBOARD FIRE CONTROL PLANS

High pressure water mist sprinkler system for fighting fires

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

RULES FOR STATUTORY SURVEY OF SEA-GOING SHIPS. FIRE-FIGHTING EQUIPMENT AND ESCAPE EQUIPMENT 2017 January

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

MARINE. High efficiency pumps you can rely on

Foam Products. Quick Reference Guide EMEA. Trusted above all.

Transcription:

LOW EXPANSION FOAM FIRE EXTINGUISHING SYSTEM

EFFECTIVE PROTECTION OF OPEN SPACE AREAS Extinguishing fi res in open space areas on vessels can be challenging, as the effects of wind and a constant supply of oxygen allow fi res to develop very quickly. The result can be extensive damage to the vessel or structure, the environment and potential loss of life. UNITOR LOW EXPANSION FOAM FIRE EXTINGUISHING SYSTEM uses a non-toxic foam concentrate, water and air to effectively extinguish fires in open spaces. The system gives safe and effective protection and is harmless to people and the environment. The system complies with the design requirements in IMO FSS chapter 14 for fixed deck foam. The foams for these systems are tested and comply with MSC circ1312. Keeps equipment and personnel safe The Unitor Low Expansion Foam System is a combination of monitors, portable applicators and foam spray nozzles, installed either individually or in conjunction with each other. Monitors are used and located according to the regulation while portable applicators and nozzles cover shadow areas not reachable by the monitors. The system has a fast and effective release of foam, with monitors that can be used in jet or fog mode. The foam seals against oxygen and reduce radiant heat. This minimises the damage caused by fi re and heat, and protects the equipment and the personnel. Solution benefits The Unitor Low Expansion Foam System is a high quality fire extinguishing system which is easy to operate. Modular skid units provide easy installation and reduced footprint. Components are protected against corrosion providing a robust, low maintenance system. To prevent foam contamination, a glassfiber reinforced polyester designed tank is used. The system can use fresh or sea water. For service purposes, foam concentrate is available worldwide as well as foam testing, service and system upgrades. The solution is designed for optimal system performance, keeping both installation and operational costs low. 2

System description The Unitor Low Expansion Foam System consists of a glass fi bre reinforced polyester foam tank, foam pump, proportioner, sturdy and compact foam monitors and portable foam applicators and foam spray nozzles. All components are constructed in corrosion resistant materials or properly coated. The monitors are located along the deck, with two monitors mounted on the poop deck. The number and spacing of the monitors, foam tank capacity and system pressure/capacity is dependent upon vessel type and the area to be protected. Foam applicators are provided for fl exibility during fire fighting on deck areas and to cover areas screened from monitors. Manual monitor In machinery spaces where a fi xed low expansion foam system is fi tted together with a total fl ooding system, the system will discharge through fixed foam spray nozzles. In addition, inductor type portable foam applicators are required. Starting the fire water pump(s) and foam pump primes the system. The distribution valves are then opened to the monitors on deck. Remotely operated valves, controlled from a central panel, can also be installed. The most fl exible remote operating system is achieved when the monitors are hydraulically operated from the same panel. Remote hydraulic monitor The system can be applied to:» Cargo tank areas» Tanker stern» Bow loading areas» Helidecks» Bilge areas» Purifi er rooms» Floating storage facilities and offshore structures Extinguishing fire using foam The Unitor Low Expansion Foam System uses either protein or synthetic foam concentrate. The foam consists of foam concentrate, water and air. As an extinguishing medium, foam is lighter than combustion materials such as oil or petrol, and consequently forms a stable foam blanket which seals against oxygen and reduces heat radiation. This effectively extinguishes fi res of hydrocarbon, polar solvents or mixtures. The system suppresses fi re by covering the surface of the burning liquid, separating the air supply and quickly extinguishing the fi re. It also cools down the area which prevents further outbreak of the fi re. 3

Standard configuration Technical data MONITOR Capacity [l/min] 1,000-12,500 Max working pressure Operation 16 bar APPLICATOR Capacity [l/min] 400 Manual or remote hydraulic Pressure [bar] 3 or 6 PUMP Type centrifugal multi-stage (& positive displacement) Voltage / frequency [V/Hz] Insulation and enclosure 3 x 400/50 3 x 440/60 or on request Class F, IP55 MIXING EQUIPMENT Type balanced pressure proportioner or inductor Capacity 75 to 20,000 [l/min] and bronze FOAM CONCENTRATE Types TANK Type Opening» fl uoro-protein foam» aqueous fi lm-forming foam (synthetic)» fl uoro-protein alcohol resistant foam» aqueous fi lm-forming alcohol resistant foam (synthetic) cylindrical glass fi bre reinforced polyester (GRP) on request full size man hole for inspection

Copyright Notice The copyright, trademarks, domain names and other intellectual property rights in all material and information in this presentation belongs to Survitec Group Limited. All rights are reserved. Disclaimer This document provides general information about Survitec Group and its companies, its products and services, and summarises general capabilities and offerings which we deem to be of relevance to our customers. Whilst Survitec has taken appropriate steps to ensure the accuracy of the information contained in this document, Survitec gives no warranty regarding the accuracy or completeness of such information. This presentation was prepared to provide information and does not constitute a contract. Survitec reserves the right, without prior notice, to change, delete, supplement, or otherwise amend at any time the information, images, and offerings contained in this presentation, or other documents. Survitec shall not be liable for any loss or damage of whatever nature (whether direct, indirect, consequential or other) that may arise as a result of any third party relying on the information contained in this document (but nothing in this disclaimer excludes liability for death or personal injury arising from negligence or any fraudulent misrepresentation). For further detailed information, prices, terms and conditions, customers should contact Survitec at info@survitecgroup.com www.survitecgroup.com