Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D. Radar sensor

Similar documents
Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D-NA. Radar sensor

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

HR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor

Retroreflective sensor with polarization filter

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

Retroreflective sensor with polarization filter

1. LCD 2. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain width adjustment 5. AIR-lenses

FACTORY AUTOMATION HANDBUCH / MANUAL / MANUAL / MANUALE

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

Sensing light curtain as per DIN 18650/EN 16005

Sensing light curtain as per DIN 18650/EN 16005

SPACEMOTION SERIES SMM 01

D-TECT Dual Tech. GJD360 Triple Technology External Detector

SWARCO TRAFFIC SYSTEMS GMBH. TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

active infrared 875 nm < 250 mw/m² motion & presence 157 in x 157 in (emitting spots**) 2 in/s to activate detection 250 ms 15-45

FlowJam Bulk Flow Detection

D-TECT 3 IP. GJD260 IP Motion Detector

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector

MPAD-C 12-24V. Ceiling microwave presence/absence detector 12-24V AC/DC. Product Guide. Overview. Features

DT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage

HANDBUCH / MANUAL / MANUEL / MANUALE TopScan-S

Operating Instructions. Digital Radar Motion Detector With Infrared Remote Control MWD BF. Hörmann KG Verkaufsgesellschaft

MWS3 Ceiling Mount Microwave Occupancy Detector

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

LZR -WIDESCAN. Motion, Presence, and Safety Sensor for Industrial Doors (US version) DESCRIPTION ENGLISH

Download the BEA DECODER app for a quick overview of settings

LZR -WIDESCAN OPENING, PRESENCE & SAFETY SENSOR FOR INDUSTRIAL DOORS

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Danfoss gas detection units

IP65 High Bay Dual Sense Sensor

R-GAGE QT50R-AFS Sensor

Radar technology in surveillance

Ceiling Microwave presence/absence detector 12-24V AC/DC

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

Topscan G3 Presence detector for automatic doors

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

Extended Range DUAL TEC Motion Sensor

KingShield. - Occupancy Detectors NEW. For complete Lighting Control... ORION RANGE. P High performance for optimum switching of all types

Movement-based energy control

IP65 High Bay Dual Sense Sensor

RS Pro Infrared Temperature Sensor

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

/ / 2018

Assembly. Connection overflow sensor. Connection fat level sensor OFF ON

K-Band Doppler Sensor Module

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Data sheet. Function description. Benefits

Danfoss gas detection units

ARCHITECTURAL DOOR HARDWARE SENSORS CATALOG

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

Orthos PIL-M02 SENSOR CONTROLLED ONE-WAY CORRIDORS

>WIRELESS> ALARM SYSTEM CR200

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

Tri-level Control Sensor

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Viewguard Motion detctors PIR and DUAL detectors

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Danfoss gas detection Controller unit

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

UV Flame Supervision System

Download the BEA DECODER app for a quick overview of settings

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

Installation Instructions

STANDARD FEATURES SPECIFICATIONS

Oxygen (O2) Single-Point Gas Detection System

Danfoss gas detection unit Type GD Heavy Duty

Hardwired Alarm Accessories

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

English. Italiano. Português. Françias. Español

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

DDS-A / DDS-B HYBRID SENSOR

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

Fire control panel detect 3004 plus and accessories

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

ANEMOMETER 4403-RF-BAT

MADE TO PROTECT OUTDOOR DUAL-TECH CURTAIN DETECTORS AGATE / AOCD-250

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

DESIGN EASY ADJUSTMENT

PHOTOELECTRIC AMPLIFIER SERIES

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Vehicle Detection: How To Choose the Right Technology... 3

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

North America Version / Dimming Function. Introduction

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

D-Tect 2 GJD300 Quad PIR Movement Detector

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

EnvironmentalMonitoring

Transcription:

Dimensions 139.6 103 99.6 46 130.7 Electrical connection Model Number Radar sensor Features Degree of protection IP67 Differentiated detection of people and vehicles, each with one output relay Cross-traffic suppression and rotation direction monitoring Simplified adjustment options via remote control or integrated push buttons Wall and ceiling mountable 4-pin terminal 1 3 4 ~/0 V ~/+UB C NO Vehicle-presence relay Indicators/operating means -pin terminal 1 C 1 3 4 NO Human-presence relay 1 "MENU" control button Green status indicator LED 3 Red status indicator LED 4 "VALUE" control button Product information The is a radar sensor for harsh industrial environments. The robust housing with IP67 degree of protection makes it the ideal door opener up to a height of 7 m. The housing concept enables time-saving mounting due to the convenient wall bracket and locking plate for adjusting the detection field. Differentiated detection of people and vehicles provides targeted door opening. This enables optimized transport routes and energy savings. 1

Technical data General specifications Sensing range Function principle Detection speed Marking Setting angle Operating frequency Operating mode Transmitter radiated power (EIRP) Functional safety related parameters MTTF d 60 a Mission Time (T M ) 0 a Diagnostic Coverage (DC) 0 % 9000 x 6500 mm (d x w) at installation height of 5000 mm and 45 angle 10000 x 5500 mm (d x w) at installation height of 7000 mm and 45 angle Microwave module min. 0.1 m/s CE -90... 90 in 15 increments 4... 4.5 GHz K-Band Radar motion sensor < 0 dbm Indicators/operating means Function indicator LED red/green Control elements Programming push-button for selection of operating modes : Direction detection, Cross traffic suppression, Vehicle detection, Switching type Control elements Adjustment for off delay Control elements Programming via keys, alternative via remote control (Accessories ordered separately) Electrical specifications Operating voltage U B 1... 36 V DC, 1... 8 V AC No-load supply current I 0 50 ma at 4 V DC Power consumption P 0 1 W Output Switching type NO/NC Signal output relay outputs Switching voltage max. 48 V AC / 48 V DC Switching current max. 0.5 A AC / 1 A DC Switching power max. 4 W / 60 VA De-energized delay t off 0.5... 300 s adjustable Directive conformity Radio and telecommunication terminal equipment Directive 014/53/EU Ambient conditions Operating temperature Storage temperature Relative humidity Mechanical specifications Mounting height Degree of protection Connection Material Housing Mass Dimensions Mounting Suitable series Series Functional principle yes This device can be used in all countries within the European Union with the exception of the United Kingdom. In other countries, the applicable national regulations must be observed. Use in North America is not permitted. -30... 60 C (-... 140 F) -30... 70 C (-... 158 F) max. 90 % non-condensing max. 7000 mm IP67 plug-in screw terminals 4-pin and pin, 8 m connecting cable included with delivery ABS, anthracite 650 g with Mounting bracket : 131 mm x 73 mm x 136 mm RAVE Microwave sensors are microwave scanners that use the principle of the Doppler radar. The most important requirement for microwave detection is that the object to be detected is moving. The microwave sensors emit microwaves of a defined frequency in order to detect people and large objects moving at speeds between 100 mm/sec. and 5 m/sec. The microwaves emitted by the emitter are reflected back from the ground or other surfaces to the receiver. If there is no motion in the monitored zone, the emitted and reflected frequencies are identical. Nothing is detected. If people, animals or objects are moving in the monitored zone, the reflected frequency changes and therefore triggers a detection. Based on the latest 4 GHz technology with integrated microprocessor control, these sensors provide a high degree of reliability even in difficult operating conditions. The 4 GHz frequency, known as the K-band, is reserved by CETECOM for this application area worldwide. The RAVE series of sensors are equipped with intelligent functions to enable them to be used in a wide variety of applications. The cross-traffic suppression system can be configured so that the door only opens when vehicles or people approach it, while passing pedestrians are Typical applications Opening impulse sensor for industrial doors Motion sensor for people and objects Detection area Accessories RMS Remote Control Infrared remote control for RMS series and RAVE RADAR RC Infrared remote control for radar sensors Other suitable accessories can be found at www.pepperl-fuchs.com

ignored. With direction detection, the opening impulse can be triggered based on the direction of motion. Depending on the setting, only movements towards or away from the sensor are detected. Settings The RAVE sensor is adjusted in programming mode directly on the device using two buttons: --> 8 = button/menu; 7 = button/value. The flashing sequence of the LEDs indicates the settings. With the RMS remote control, available as an accessory, the sensor can be easily and quickly programmed from the ground. The bidirectional infrared remote control with an LCD display and self-explanatory menu interface has a range of 10 m. Even sensors with considerable installation heights can be precisely and easily adjusted. Model number for remote control: RMS remote control 1 3 4 1 "MENU" control button Green status indicator LED 3 Red status indicator LED 4 "VALUE" control button 1) The following properties are adjustable: 1. Dimensions of the detection area Mounting height 5 m Mounting height 7 m At maximum sensitivity and angle of incidence approx. 9 m approx. 10 m approx. 6.5 m approx. 5.5 m. Dimensions of the detection area The size of the sensing area can be changed by adjusting the sensitivity using the buttons or remote control. High sensitivity = Large area Low sensitivity = small area 3. Position of the sensing area: Snap-in positions are provided every 15 degrees to allow the sensor to be tilted depending on requirements. To adjust the tilt angle, loosen the long screw, move the sensor into the required position (the sensor will snap into place) and tighten the long screw again. 15 30 45 15 45 4. Inclined detection area Installing the mounting bracket on an incline has the following effects on the detection field: 3

5. Detection without rotation direction monitoring Forward/backward 6. Detection with rotation direction monitoring Forward (toward the sensor) Backward (away from the sensor) 7. Cross-traffic suppression Without suppression: door opens even in the event of cross-traffic With suppression: door remains closed in the event of cross-traffic 8. Detection of people/vehicles The sensor evaluates movements of people and vehicles in different ways and switches the vehicle relay or the person relay according to the setting. The ability to distinguish between people/vehicles makes it possible to open the door only for vehicles. Approaching people must use the side entry. Function indicator LED Red/green flashing Green Flashing green 3x Flashing red in quick succession Flashing green in quick succession Red/green flashing in quick succession. Status Sensor initialization in progress Sensor ready for operation, no detection Command received from remote control Vehicle-presence relay active Human-presence relay active Vehicle-presence relay and human-presence relay both active Application examples: Distinguishes between people and vehicles Example 1: Vehicle recognition at a door Door controller with one switch input. Output function for vehicle-presence relay "Vehicle forward". Vehicle-presence relay is activated. The door opens. Vehicle-presence relay is not activated. Door remains closed Example : Door with vehicle recognition and separate entrance for people Door control with two switching inputs (vehicle-presence relay and human-presence relay). Output function for vehicle-presence relay "Vehicle forward". Output function for human-presence relay "Person forward". Relay configuration as per factory settings.* 4

Vehicle-presence relay is not activated. Door remains closed. Human-presence relay is activated. Entrance for people opens. Vehicle-presence relay is activated. The door opens. Humanpresence relay is not activated. Entrance for people remains closed. Example 3: Door with vehicle recognition without separate entrance for people Door control with two switching inputs (vehicle-presence relay and human-presence relay). Output function for vehicle-presence relay "Vehicle forward". Output function for human-presence relay "Person forward". Relay configuration as per factory settings.* Vehicle-presence relay is not activated. No action. Humanpresence relay is activated. The door opens half-way. Vehicle-presence relay is activated. The door opens fully. Humanpresence relay is not activated. No action. *) Vehicles crossing the detection range of the sensor may cause the human-presence relay to be activated unexpectedly. 5