[WHAT WORKS & WHAT S NEW THAT WORKS]

Similar documents
UPGRADES. [Energy Efficiency] Base Points

High Performance Building Guide 1

Update Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South

sm All Product Catalog

HVAC System Consideration$ 05/14/2012 SAVING MONEY IN HVAC SYSTEMS

Advanced Heating & Hot Water Systems. High Efficiency Residential & Commercial Space Heating

Natural Gas Energy Efficiency Program. The Hotel/Lodging Industry

REQUIRED CONTRACT DETAIL. $2, , Direct DC Fuel Cell Power System, Stationary PACE Power output < 40 kw

Daikin Blueprint: Delivering Hot Water with a Chiller

Hydronic & HVAC Control Systems

Missouri HERO Program Residential Eligible Product List

It pays to save energy. Guide to Xcel Energy rebates, incentives and programs for residential customers in Minnesota

Industrial Heat Pumped Hot Water

Exploratory Lab Testing of a Residential-Scale Combined Space and Water Heating CO 2 Heat Pump

NET ENERGY WATER LOOPS A clear path to net zero energy buildings

Strategies for Building Energy Efficiency

Building Division WSEC & IRC Ventilation (Effective July 1, 2016) Residential Buildings Prescriptive Compliance Form

Direct Install Program Eligible Measures Listing:

SUMMARY OF SERVICES & INCENTIVES

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

Intermediate framed denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation.

2011 Manitoba Energy Code for Buildings (MECB) PART 5, Heating, Ventilating and Air-conditioning Systems

YMGI HVAC Line Card VRF Outdoor Units

HVAC Trajectories toward Zero

Combined Space and Water Heating: Making it Work

Product Line Introduction. Karl Zhang Technical support engineer

REGULATIONS GOVERNING WATER SERVICE TO CUSTOMERS OF THE EAST BAY MUNICIPAL UTILITY DISTRICT SECTION 31 WATER EFFICIENCY REQUIREMENTS

ROTEX AUSTRALIA. Smart Hot Water

Better Design, Better Control, Better Systems.

Increase your flexibility.

General HVAC Recommendations

LACLEDE ENERGY EFFICIENCY PROGRAMS

EXISTING MULTIFAMILY OREGON CASH INCENTIVES. Standard Incentives SAVE MONEY AND ENERGY NOW AND FOR YEARS TO COME.

If pre-approval is required - work with your Energy Advisor to obtain pre-approval prior to purchasing equipment.

Innovative Boiler & Heat Exchanger Concepts

Indoor Water Use SECTION 31 REGULATIONS AND CALGREEN CODE COMPLIANCE. Fixture & Appliance Requirements. Water Efficiency Review

SUPPORTING DOCUMENT RESIDENTIAL ENERGY CODE WORKSHEET (2015) EFFECTIVE JANUARY 1, 2017

b.) Technical Information:

Steven Winter Associates, Inc. J827

Path to your Energy Savings. Existing Residential and Small Commercial

Proposed Mechanical, Plumbing, and Electrical Systems For the LEDYARD POLICE DEPARTMENT LEDYARD, CT

ENGINEERING REPORT - MECHANICAL / ELECTRICAL / PLUMBING

Raptor 320HB & 399HB Submittal Sheet

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

The Ed Roberts Campus Berkeley, CA

Product Rebates INDIANA

Multifamily Buildings: Real World Monitored Data on Hot Water Energy and Water Use

Path to Energy Savings & Solar

EVERGREEN HIGH EFFICIENCY CONDENSING BOILER

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

PERFECT SOLUTIONS WATERFURNACE COMMERCIAL PRODUCTS. Water Source/Geothermal Heat Pumps

National Grid s Direct Install Program for Commercial Customers

CONTROLLED CHILLED BEAM PUMP MODULE

Total Credits 0.00 *Please refer to Table R406.2 for complete option descriptions

ERGON EQUIPMENT SA PRESENTATION

SEE WHAT SAVING ENERGY AND MONEY CAN DO FOR YOUR BUSINESS.

EVERGREEN HIGH EFFICIENCY CONDENSING BOILER EASY HEAT, EFFORTLESS COMORT

COMMERCIAL Washington Incentives

* Peak kw is determined by the average kw load reduction occurring between 1PM and 4PM on weekdays during June, July and August.

Drain Water Heat Recovery

SOLAR THERMAL HEATING: ALIVE AND WELL

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

GARCIA GALUSKA DESOUSA Consulting Engineers

2015 RESIDENTIAL ENERGY CODE WORKSHEET BPA LOG# for Prescriptive Energy Code Compliance

Smart vs. Proprietary Thermostat Webinar Which is best for your customers? Session #1 5/3/ am CST Session #2 5/11/ pm CST

2006 Washington State Nonresidential Energy Code Compliance Form Washington State Nonresidential Energy Code Compliance Forms Revised July 2007

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

COMMERCIAL PRODUCT LINE

HEAT PUMPS EN - flyer 10/p/2017 Made in Poland

Non-residential Northwest Energy Efficiency Council Lisa Rosenow

NAHB Green Home Building Guidelines. 3.1 Prerequisites. ResCheck. Energy Efficiency

Innovative Technologies [and Design Concepts] in Commercial Foodservice

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

August 15, 2013 Page 1 of 19

SHConDEMAND. True Redundancy. Heating. Cooling. Simultaneous. Efficient. Reliable

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Technology Applied. IGSHPA Conference

CONTROLLED CHILLED BEAM PUMP MODULE

Focus on Energy Business Programs Summary of Services and Incentives July 2009

Versa- Hydro. up to 96% Efficient

COMcheck Software Version Mechanical Compliance Certificate

Inspection Phase Three. Mechanical, Electrical & Plumbing Section 503

b) Medium dwelling units that are not included in (a) above {small dwelling}, OR (c) below {large dwelling} Requires 3.5 credits

INDEX. ADDITIONS AND ALTERATIONS Defined Requirements ADMINISTRATION AND ENFORCEMENT... Chapter 1 AIR ECONOMIZERS

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating

Energy Options for Residential Heating. Juergen Korn, P.Eng.

New and Emerging HVAC Technologies. Rod Rhoads, GDS Associates Dave McCullaugh, Mitsubishi Electric Trane HVAC US Dave Binz, Cambridge Engineering

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor

Smardt Oil-Free Chillers

Hot Water. The Efficiency Challenge!

AHRI Certification Program Scopes - COOLING

Equipment Efficiency Guide

UGI Utilities, Inc. EE&C Programs Housing Alliance of PA Webinar 12/15/2017

Solar Thermal Planning Worksheet Date: / /

HVAC Energy Efficiency Strategies

CASE STUDY: HIGH EFFICIENCY HOT WATER SYSTEMS IN A COMMERCIAL KITCHEN. For the 2019 ACEEE Hot Water Forum, Nashville, TN

2015 NATURAL GAS EFFICIENCY REBATE APPLICATION

... Air Conditioners & Heat Pumps Light Commercial ...

Transcription:

NORIAN SIANI ENGINEERING, INC. Sergio F. Siani 43 Bradford Street, 3rd Floor Concord, MA 01742-2972 ph. 781 398 2250 x-117 fx. 781 398 2280 SergioS@NS-Engineering.com 43 Bradford Street, 3 rd Floor, MA 0742-2972 Tel: 781-398-2250 [WHAT WORKS & WHAT S NEW THAT WORKS] 10/23/2012 1

2

65 Points required for Gold Certification in the USGBC, LEED-H New Construction Program ~70% of these points are from MEP 3

Before Retrofit Energy Cost = $437,000/yr Energy Cost = $ 2,428/Apt-yr Improved Thermal Envelope Convert from Electric to Gas Heat Energy Recovery Ventilator 2 Co-Gen Engines Photovoltaic s (PV) Added Air Conditioning After Retrofit Energy Cost = $263,000 Energy Cost = $ 1,461/Apt-yr 40% Savings!!! Lyndon B. Johnson Apartments 4

BLEEDING EDGE? or CUTTING EDGE! 5

6

Know the Economics of your Local Utility/Fuel Costs and Different Seasonal System Efficiencies 7

Know the Economics of your Local Utility/Fuel Costs and Different Seasonal System Efficiencies 8

9

10

Less than 1 Year Payback Easily Installed by Staff 0.5 GPM Lavatory Aerators 1.5 GPM Kitchen Aerator 1.5 GPM Showerheads Niagara Plumbing Products http://www.niagaraconservation.com 11

Dual Flush 1.28/0.8 GPF MaP 800 g Flush 0.8 GPF MaP 600 g Caroma - http://www.caromausa.com Profile Smart 305 Niagara - http://www.niagaraconservation.com Stealth 12

Indirect Fired DHW Generator for Central Systems Minimize Storage Volume Maximize Heat Exchange (1) 120 Gal Tank up to 40 Apts (2) 120 Gal Tanks up to 80 Apts Triangle Tube - Smart Series http://www.triangletube.com Individual Tankless DHW Tanks Quality Matters Efficiency 96% Rinnai - http://www.rinnai.us 13

Demand Control DHW Recirculation Systems http://www.enovativegroup.com Thermostatic Recirculation Valve http://www.circuitsolver.com 14

Variable Speed Pumping to match varying requirements, saves up to 50% of Power Consumption Multiple Pump Control Grundfos Hydro MPC - http://www.grundfos.com 15

Laundry Waste Heat Recovery Preheat Coldwater Paybacks as Rapid as 4 yrs Watercycle - http://www.watercycles.ca/ 16

Pipe Insulation Extended Valve-Stem for Insulating and Heat Loss Reduction Insulated Pipe Hangers Anvil International - http://www.anvilintl.com/ 17

18

Condensing Boilers: Up to 5000 MBH Input 96% Efficiency Variable Output 100% -20% Stainless Steel Option for pool water heating Lochinvar - http://www.lochinvar.com 19

20

Up to 98% AFUE Variable Speed Fan Multiple Zone Compatible ECM Motors Lennox - http://www.lennox.com 21

Varying Speed, Flow, or Temperature to Achieve Increased Efficiencies Johnson Controls http://www.johnsoncontrols.com Taco http://www.taco-hvac.com Modulating 2- Way Valves VFD s Outdoor Reset Control 22

Performance Depends on Climate COP s for Heating up to 4.7 Great for Retrofit Higher Material Cost & Lower Installation Cost Indoor Units Outdoor Units Mini-Splits Up to 30 Tons Up to 5 Tons Mitsubishi - http://www.mehvac.com/ Connects Up to 50 Indoor Units Connects up to 4 Indoor Units 23

24

Cooling EER s up to 12.9 Great for Retrofit Higher Material Cost & Lower Installation Cost Outdoor Units Indoor Units Mini-Splits Up to 30 Tons Up to 5 Tons Mitsubishi - http://www.mehvac.com/ Connects Up to 50 Indoor Units Connects up to 4 Indoor Units 25

VFD s for Cooling Tower Fans http://spxcooling.com 26

Smardt Chiller http://www.smardt.com Magnetic Bearings 60 Tons 1,200 Tons Oil Free Compressor 27

28

Adaptive Recovery (Not Static Schedule for Occupied/Unoccupied) Uses History of Past Performance and/or Future Outdoor Temperature to Optimize Advanced products provide WiFi Link & Advanced Weather Updating Nest http://www.nest.com Honeywell http://www.honeywell.com 29

Fixed Temperature Limits, Max & Min, Heat & Cool Customizable Temperature Difference Photo Detector Auto-Setback Photo Sensor Lightstat - http://www.lightstat.com 30

For More Complex Systems Reduced approach suitable for monitoring only what is desired (eg: Boilers) Expandable Web-Connected Used for Measurement & Verification (M&V) http://www.tridium.com 31

32

Generate Thermal Energy & Power Simultaneously Cost Effective if: 100-120 Dwelling Units Large Enough Electric Load on Common Meter Central DHW System Heated Swimming Pools Help Improve Economics Efficiency up to 93.6% Tecogen - http://www.tecogen.com 33

Aspirating Air Collectors Preheat Outside Air for Ventilation Most Cost Effective Renewable Energy Option Independent of Rebates, SREC s, and Other Funding Matrix Air - http://www.matrixenergy.ca 34

Solar Aspirating Air Collector for Ventilation Outside Air Pre-Heat PV 2,500 ft 2 Collector Area 10,000 CFM 9 yr Payback Before Rebate & other Funding Assistance Solar Photovoltaic (PV) 35

Thank You for Understanding That Sustainable Design Can & Does Work for You Economically When Well Considered & Executed 36